![<b>Disassembly </b>. Zenith ZW5000Y8, GWHD5000, ZW5000, HW500CM | Manualzz <b>Disassembly </b>. Zenith ZW5000Y8, GWHD5000, ZW5000, HW500CM | Manualzz](http://s3.manualzz.com/store/data/063875590_1-b0207e39ed9124cdc337f9bfbcaeee8e-360x466.png)
Disassembly
Disassembly
Mechanical Parts
1. FRONT GRILLE
1. Disconnect the unit from source of power.
2. Using a screwdriver, remove the screw from the front grille. (See Figure 13)
3. Push the front grille up from the bottom.
Pull the top of the front grille away from the cabinet as the top tabs lift out of their slots. (See Figure 14)
4. Replace the grille by placing the tabs in the slots and push the grille until it snaps into place.
2. CABINET
1. Disconnect the unit from the power source.
2. Remove the front grille. (Refer to section 1)
3. Remove 10 screws that secure the cabinet to the base pan and condenser. (See Figure 15)
4. Lift the cabinet from the unit.
5. Re-install by referring to the procedures above.
3. CONTROL PANEL
1. Disconnect the unit from the power source.
2. Remove the front grille. (Refer to Section 1)
3. Remove the cabinet. (Refer to Section 2)
4. Remove 2 screws that secure the control panel to control box and base pan. (See Figure 16)
5. Pull the control board toward yourself.
NOTICE Controls, wires, and capacitor are now accessible for servicing. Discharge the capacitor before servicing.
Figure 13
Figure 14
Figure 15
6. Disconnect one housing terminal and 3 wires for the fan motor and compressor. (See Figure 17)
7. Re-install components by referring to procedures above.
(Refer to wiring diagram on page 19 in this manual or on control box.)
Figure 16
Figure 17
Service Manual
13
advertisement
Related manuals
advertisement
Table of contents
- 3 Safety Precautions
- 7 Dimensions
- 7 Outside Dimensions
- 8 Product Specifications
- 9 Installation
- 9 Select the Best Location
- 9 How to Install
- 10 Installation Kits Content(Some Models)
- 11 How to Secure the Drain Pipe
- 12 Operation
- 12 Features
- 12 Insulation Resistance Test
- 12 About the Controls on the Air conditioner
- 13 Disassembly
- 13 Mechanical Parts
- 14 Air Handling Parts
- 15 Electrical Parts
- 16 Refrigerating Cycle
- 19 Schematic Diagram
- 19 Wiring Diagram
- 20 Troubleshooting Guide
- 20 Piping System
- 21 Troubleshooting Guide
- 23 Room Air Conditioner Voltage Limits
- 26 Exploded View
- 27 Replacement Parts List