REED R6200 is a versatile device that measures various environmental parameters and calculates the WBGT (Wet Bulb Globe Temperature) to assess heat stress levels. With its ability to measure ambient temperature, humidity, dew point, wet bulb temperature, black globe temperature, and barometric pressure, it's ideal for evaluating heat-related stress in both indoor and outdoor environments, making it suitable for applications in meteorology, agriculture, construction, and health and safety.
advertisement
Memory Recall
1.
Press and hold the MODE button to recall the recorded Temperature/
RH measurement values and sequential number.
2.
Press the HOLD button to scroll up the stored readings.
3.
To scroll down the stored readings, press the BKLT button.
4.
To exit memory recall function, press and hold the MODE button at which point you will be redirected into the WBGT alarm threshold setting.
5.
Press and hold the MODE button again to exit the memory recall function and resume normal operation.
Clear Stored Readings
When required, you can clear the stored readings by pressing and holding the SET button. The LCD display will indicate "---" confirming that the stored values have been cleared.
WBGT WBGT
WBGT Audible Alarm Threshold Setting
(The default WBGT temperature alarm value is set at 31°)
1.
Press and hold the MODE button for 2 seconds and the meter will enter memory recall function.
2.
Press and hold MODE button again to enter
WBGT alarm function.
3.
Press the HOLD button to increase the value.
4.
Press the BKLT button to decrease the value.
5.
Press the UNIT button to confirm your selection and jump to the next digit.
6.
Repeat steps 3 to 5 for each digit.
7.
Once the alarm is selected, press and hold the
MODE button to save the value and resume normal operation.
WBGT
% continued...
REED Instruments 9
1-877-849-2127 | [email protected] | www.reedinstruments.com
GT
%
MAX
MIN
AVG hpa
%
REC
GT
3
4
5
% hpa hpa
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Introduction
- 3 Product Quality
- 3 Safety
- 4 Features
- 4 Specifications
- 5 Included
- 6 Instrument Description
- 6 Display Description
- 6 Operating Instructions
- 6 Power ON/OFF
- 7 MAX/MIN/AVG
- 7 Indoor/Outdoor Temperature Mode Selection
- 7 Switching the Temperature Unit of Measure
- 7 Switching the Pressure Unit of Measure
- 7 Temperature Display Modes
- 8 Data Hold
- 8 Auto-Power Off
- 8 Backlight Function
- 8 Internal Memory
- 9 Memory Recall
- 9 Clear Stored Readings
- 9 WBGT Audible Alarm Threshold Setting
- 10 Turn Alarm Function ON/OFF
- 10 Offset Function
- 10 Globe Temperature Offset
- 11 Ambient Temperature Offset
- 11 Humidity Offset
- 11 Pressure Offset Function
- 11 Error Codes
- 12 Battery Replacement
- 12 Applications
- 12 Accessories and Replacement Parts
- 13 Product Care
- 13 Product Warranty
- 14 Product Disposal and Recycling
- 14 Product Support