DIN CONNECTION. Aqua Lung CORE

Add to My manuals
23 Pages

advertisement

DIN CONNECTION. Aqua Lung CORE | Manualzz

20. Check that the yoke shutter crown (129205) shoulder is about 1.5mm (0.4 inches) above the yoke retainer

(129242). Push down with your finger against the crown shutter to confirm the ACD system works.

21. Using a 1/4’’ socket wrench

(116239), fit a new O-ring not lubricated (124703) in the body counterbore (129254) DIN connection side.

22. Insert a new filter (129209) in the socket wrench

(116239) and then turn over the body (129254) and put the filter inside the O-ring (124703) thanks to the socket wrench.

23. Place the sub-assembly shutter/retainer in the yoke

(124611). Screw it manually into the body (129254) until it blocks.

Securely clamp holding tool (116230) into vice with yoke connection facing up.

Using a torque wrench (122154) with the socket

(A11001), tighten the yoke retainer to 2.5 m.kg

(18.08 ft.lb) . Remove the regulator from the vice.

24. Thread the dust cap (124555) into the yoke screw

(128631), with the Aqua Lung logo outside. Screw the yoke screw into the yoke (124611).

Service Manual Core 1 st stage

Rev. 05/2015

Service Manual Core 1 st stage

DIN CONNECTION

Start after point 9

25.

Using a 1/4’’ socket wrench

(116239), fit a new O-ring not lubricated (124703) in the body counterbore (129254) DIN connection side.

26. Insert a new filter (129209) in the socket wrench

(116239) and then turn over the body (129254) and put the filter inside the O-ring (124703) thanks to the socket wrench.

27. Fit in a new and lubricated Oring (444243) on the DIN screw

(129213 ).

28. Take the DIN union (129241), install the

DIN hand wheel (129929) on it, and place on top the DIN screw (129213).

Screw by hand the DIN screw into the

DIN union.

29. Using a 7/16'' socket, screw the sub-assembly into the body (129254).

Securely clamp holding tool (116230) into vice with

DIN connection facing up.

Using a socket and a torque wrench (122154), tighten the DIN screw to 2.5 m.kg (18.08 ft.lb).

12

advertisement

Key Features

  • Compact and lightweight, the CORE is easy to pack and carry.
  • Over-balanced diaphragm design provides consistent airflow even at low tank pressures.
  • Sealed first stage keeps contaminants out, ensuring reliable performance.
  • Adjustable second stage allows you to fine-tune your breathing effort.
  • Venturi system helps to prevent free-flow, even in strong currents.
  • Large purge button makes it easy to clear the second stage of water.
  • Swiveling hose attachment allows for easy hose routing.
  • Optional DIN or yoke adapter makes the CORE compatible with any tank.
  • Lifetime warranty provides peace of mind.

Related manuals

Frequently Answers and Questions

What should be done if the regulator has been used in a chlorinated or aggressive environment?
The service period should be reduced to six months.
When should Aqua Lung regulators receive complete service?
Aqua Lung regulators should receive complete service once a year. If the regulator is used in a chlorinated or aggressive environment, the service period should be reduced to six months.
What is the minimum service requirement for Aqua Lung regulators?
Aqua Lung regulators should undergo servicing at least once every two years and visual inspection at least once per year.
What should be done before starting to disassemble the regulator?
Read the manual through completely and keep it open for reference.
What precautions should be taken when holding the regulator body?
The regulator body should never be directly held in the jaws of a vice. Use the tool (116230) and vice to hold the body.
What should be done when reassembling the regulator?
Check that the torque used conforms with the values shown in Table 4. Some parts can be irreparably damaged if the acceptable torque is exceeded.
What type of spare parts should be used for Aqua Lung regulators?
Only spare parts from Aqua Lung service kits should be used.