Agilent MOI for DisplayPort Cable & Connector Compliance Tests

6.5.4.

Near End Noise (NEN)

Near End Noise Upper Limit for High Bit Rate Cable Assembly

Near End Noise Upper Limit for Reduced Bit Rate Cable Assembly

6.5.5.

Far End Noise (FEN)

The Power Sum Equal Level Far End Noise specification applies to all cable assembly types. The Power Sum Equal Level Far End Noise represents the difference between cable insertion loss and the total power sum far end noise from aggressor cable lanes.

44

Agilent MOI for DisplayPort Cable & Connector Compliance Tests

Far End Noise Upper Limit for High Bit Rate Cable Assembly

Far End Noise Upper Limit for Reduced Bit Rate Cable Assembly

PSELFEN max