IECEx/ATEX Certificate and Dust Rating. Beijer Electronics MAEN256B

Add to My manuals
33 Pages

advertisement

IECEx/ATEX Certificate and Dust Rating. Beijer Electronics MAEN256B | Manualzz

Safety Precautions

Use minimum 85°C copper conductors only.

To make wiring connections to the power supply connector, follow the table with cable and torque specifications below:

These devices are Class 2 supplies programmable controllers (industrial PCs) or the use in industrial control equipment and are intended to be (front) panel mounted.

For use on a flat surface of an enclosure.

Terminal Block Connector

Phoenix Contact

Wire Size

0.5 – 3.3 mm 2

Torque (Nm)

0.6 – 0.8

Caution:

The equipment shall be installed in an enclosure that provides a degree of protection not less than IP 66 in accordance with EN/IEC 60079-0 when used in Zone2/22 applications.

The inside of the enclosure the device is mounted in shall not be more than pollution degree 2, as defined in EN/IEC 60664-1.

CET ÉQUIPEMENT EST TESTÉ EN TANT QUE COMPOSANT ET DOIT ÊTRE

INSTALLÉ DANS UN BOÎTIER AVEC INDICE DE PROTECTION IP 66 MINIMUM.

Caution:

Temperature code T4 IEC/EN60079-0, IEC/EN60079-7, IEC/EN60079-15 and IEC/

EN60079-31.

Protection string Ex ec nC IIC T4 Gc and Ex tc IIIC T82 °C Dc.

CODES DE TEMPÉRATURE T4 IEC/EN60079-0, IEC/EN60079-7, IEC/EN60079-15 et

IEC/EN60079-31.

CHAîNE DE PROTECTION Ex ec nC IIC T4 Gc et Ex tc IIIC T82 °C Dc.

II 3 G Ex ec nC IIC T4 Gc

II 3 D Ex tc IIIC T82 °C Dc

In a Zone 2 environment, this equipment shall be installed in an enclosure that provides a degree of protection not less than IP54 in accordance with

IEC/EN 60079-0. The IP rating of the equipment is limited to the IP rating of the enclosure it is to be installed into.

In a Zone 22 environment, this equipment shall be installed in an enclosure that provides a degree of protection not less than IP64 in accordance with

IEC/EN 60079-0. The IP rating of the equipment is limited to the IP rating of the enclosure it is to be installed into.

Beijer Electronics, MAEN256B 6

advertisement

Key Features

  • Built-in functions for displaying and controlling text, dynamic indication, time channels, alarm and recipe handling.
  • Connects to various automation equipment such as PLCs, servos or drives.
  • UL and cUL certified for use in hazardous locations.
  • IECEx/ATEX certified for use in Zone 2/22 hazardous areas.
  • IP66 rated for protection against dust and water.
  • Wide operating temperature range (-20°C to +60°C).
  • High screen resolution (1280 x 800 pixels).
  • Capacitive touch screen for precise control.

Related manuals

Frequently Answers and Questions

What is the purpose of the Beijer Electronics MAEN256B operator panel?
The Beijer Electronics MAEN256B operator panel is designed for monitoring and controlling industrial automation applications.
Does the MAEN256B require special software for configuration?
Yes, the MAEN256B requires iX Developer software for configuration.
Is the MAEN256B suitable for use in hazardous locations?
Yes, the MAEN256B is both UL and cUL certified for use in hazardous locations.
What is the IP rating of the MAEN256B?
The IP rating of the MAEN256B is IP66, indicating protection against dust and water.
What is the maximum operating temperature of the MAEN256B?
The maximum operating temperature of the MAEN256B is +60°C.