advertisement
MT. VERNON AE
and Welcome to the Quadra-Fire Family !
A. Congratulations
Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance.
tion of our stoves, inserts and fireplaces. And yet we are old-fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and gold and nickel surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection.
This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum opera-
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire.
NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction
B. Sample of Serial Number / Safety Label
LOCATION: Back of Stove
Model
Name Serial No.
CAUTION
:
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND
ATTENTION:
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:
A
C
F D
G
B
C
E
G
A 2 in (51mm)
B 6 in. (152mm)
C 2 in. (51mm)
D 3 in. (76mm)
INSTALLATION DE L’ALCÔVE
E 6 in. (152mm)
F 8 in. (203mm)
G 3 in. (76mm)
Une hauteur minimum de l'alcôve:
Une hauteur minimum mur de côté de l'alcôve:
La profondeur maximum de l'alcôve:
PROTECTION
DU SOL
I* = 2 in. (51mm)
J = 2 in. (51mm)
K = 6 in. (152mm)
J
K
I*
43 in.(1092mm)
6 in. (152mm)
Une épaisseur minimum mur de côté de l'alcôve: 40 in. (1016mm)
36 in. (914mm)
Note 1: Dans les installations résidentielles, lorsque les pièces
TPVNT-MV, (dessus de l'adapteur de ventilation 3 in. - 3 in.) et
812-3570 (le ressaut de l'adapteur 3 in. - 6 in.), un tuyau connecteur de 6 in. pour mur simple de calibre 24 peut être utilisé.
Note 2: Pour l'installation dans les maisons préfabriquées, lorsque les pièces TPVNT-MV, (dessus de l'adapteur de ventilation 3 in. - 3 in.) et 812-3570 (le ressaut de l'adapteur 3 in. - 6 in.), utilisez un tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce 811-0872), doit
être utilisé pour l'installation dans les maisons préfabriquées.
J
Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans l'installation dans les maisons mobiles. Cet appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR 814-23-9000 jusqu'à 814-23-909.
Testé à: ASTM E1509-04, ULC S627-00, ULC/ORD-C1482-M1990
AVEC LES BOULETTES DE BOIS. VOIR LE MANUEL DU
PROPRIÉTAIRE POUR D’AUTRES OPTIONS DE CARBURANT.
OMNI-Test Laboratories, Inc. a déterminé que cet appareil se conforme avec la norme de l’Association Canadienne de normalisation (CSA) B415.1 ainsi que le
Titre 40 du Code Fédéral de Régulations des États-Unis, partie 60, sous-partie
AAA. Accréditations OMNI-Test Laboratories : Le Conseil Canadien des Normes
(CCN/SCC), l’Institue des Standards Nationaux Américain (ANSI) et l’Agence de
Protection Environnemental (EPA).
Puissance de Rendement: 60,000 Btu's/hr
Puissance Électrique: 115 VAC, 60 Hz, Début 5 Amps, Courir 1.25 Amps
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. Ne pas bloquer l’espace au dessous de
DANGER : Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service.
température du thermostat en dessous de la température de la pièce. Pour des porte d'ouverture et la porte des cendres fermées hermétiquement durant l'opération.
Installez et le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les schémas l’indiquent. Mesurez la distance du devant (K) de la surface de la porte vitrée.
*Un protecteur incombustible de plancher doit s'étendre sous le conduit de cheminée pour une installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une installation verticale. CANADA - REQUIRENT.
PREVENT HOUSE FIRES and operating instructions. Contact local building or fire officials about restrictions and inspection in our area.
WARNING - FOR MOBILE HOMES
Refer to manufacturer's instructions and local codes for precautions required for passing chimney through a combustible wall or ceiling. Inspect and clean vent system frequently in accordance with manufacturer's instructions.
DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING
ANOTHER APPLIANCE.
: Do not install appliance in a sleeping room. An outside combustion air inlet must be provided. The structural integrity of the mobile home floor, ceiling and walls must be maintained.
M P
PRÉVENTION DES FEUX DE MAISON
Installez et utilisez en accord avec les instructions d'installation et d'opération du fabricant. Contactez le bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil.
AVIS - Pour Les Maisons Mobiles: une chambre à coucher. Un tuyau extérieur de combustion d'air doit être installé et ne doit pas être obstrué lorsque l'appareil est en usage. La structure intégrale du plancher, du plafond et des murs de la maison mobile doit être maintenue intacte.
Référez vous aux instructions du fabricant et des codes locaux travers un mur ou un plafond combustibles, et les compensations maximums.
Inspectez et nettoyez la cheminée fréquemment. Ne pas connecter cet appareil à une cheminée servant un autre appareil.
Utilisez systèm de ventilation "L" ou "P" diamètre 76mm ou
102mm.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
Home Installation. This appliance has been tested and listed for use in
OAR 814-23-9000 through 814-23-909.
Tested to: ASTM E1509-04, ULC S627-00,
ULC/ORD-C1482-M1990 Room Heating
Pellet Burning Type, (UM) 84-HUD FOR USE
ONLY WITH PELLETIZED WOOD. See Owner’s
Manual for other fuel options.
OMNI-Test Laboratories, Inc. has determined that this appliance complies with Canadian
Standards Association (CSA) B415.1 and Title
40 of the U.S. Code of Federal Regulations, Part
60, SubPart AAA.OMNI-Test Laboratories
Accrediations: The Standards Council of
Canada, the American National Standards
Institute, and the U.S. Environmental Protection
Agency.
Route power cord away from unit. Do not route cord under or in front of appliance. Do not obstruct the space beneath the heater.
DANGER: Risk of electrical shock.
Disconnect power supply before servicing.
Replace glass only with 5mm ceramic
ALCOVE INSTALLATION:
Min. Alcove Height:
43 in. (1092mm)
Min. Alcove Side Wall:
6 in. (152mm)
Min. Alcove Width:
40 in. (1016mm)
Max. Alcove Depth:
36 in. (914mm)
A
C
A 2 in (51mm)
B 6 in. (152mm)
C 2 in. (51mm)
D 3 In (76mm)
E 6 in (152mm)
F 8 in.(203mm)
G 3 in. (76mm)
F
Note 1: In residential installations, when using
Parts TPVNT-MV, (3 in. - 3 in. Top Vent Adapter) and
812-3570 (3 in. - 6 in. Offset
Adapter), 24 gauge 6 in. single wall flue connector may be used.
D
G thermostat above room temperature, the stove will light automatically. To shutdown, manual.Keep viewing and ash removal doors tightly closed during operation.
Manufactured by / Fabriqu é par:
1445 Highway North,
Colville, WA 99114 www.quadrafire.com
Made in U.S.A. of US and imported parts.
Fabriqué aux États-Unis-d’Amérique par des pièces d’origine américaine et pièces importées.
DO NOT REMOVE THIS LABEL
NE PAS ENLEVER L’ÉQUETTE
Note 2: In manufactured home installation, when using Part
TPVNT-MV, (3 in. - 3 in. Top Vent
Adapter) and 812-3570 (3 in. - 6 in.
Offset Adapter), use listed double wall flue connector. An Outside Air
Kit (Part 811-0872), must be used with manufactured home installation.
FLOOR PROTECTION I*
I* = 2 in. (51mm)
J = 2 in. (51mm)
J J
K = 6 in. (152mm)
K
Use a non-combustible floor protector, extending beneath heater and to the front/sides/rear as indicated.
Measure front distance (K) from the surface of the glass door.
*Non-combustible floor protection must extend beneath the flue pipe when installed with horizontal venting or under the
Top Vent Adapter with vertical installation. RECOMMENDED
IN USA
B
C
E
G
Mt. Vernon Pellet
Stove AE
SERIAL NO.
007001
/ NUMÉRO DU
Tested and
Listed by
O-T L Portland
Oregon USA
C US
OMNI-Test Laboratories, Inc.
Report / Rapport
061-S-68-6
7034-107E
Mfg. Date
Test Lab &
Report No.
2 7034-276 January 29, 2014
MT. VERNON AE
Safety Alert Key:
• DANGER!
Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING!
Indicates a hazardous situation which, if not avoided may result in death or serious injury.
• CAUTION!
Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.
• NOTICE: Indicates practices which may cause damage to the appliance or to property.
A. Congratulations..................................................................2
B. Sample of Serial Number / Safety Label ............................2
C. Warranty Policy .................................................................4
1 Listing and Code Approvals ..............6
A. Appliance Certification ......................................................6
B. BTU & Efficiency Specifications ........................................6
C. Glass Specifications .........................................................6
D. Electrical Rating................................................................6
E. Mobile Home Approved .................................................... 6
2 Operating Instructions .......................7
A. Fire Safety .........................................................................7
B. Non-Combustible Materials ...............................................7
C. Combustible Materials ......................................................7
D. Fuel Material and Fuel Storage ........................................7
E. General Operating Information .........................................8
F. Before Your First Fire ........................................................9
G. Filling the Hopper with Fuel ...............................................9
H. Starting Your First Fire .....................................................9
I. Fire Characteristics and Flame Height Adjustment ............9
J. Clear Space.......................................................................10
K. Ignition Cycles ...................................................................10
L. Frequently Asked Questions .............................................12
3 Wall Control Operating Instructions 13
A. Introduction .......................................................................13
B. Language Selection ..........................................................13
C. The Main Screen ..............................................................13
D. General Information About Using the Wall Control ...........14
E. The Main Menu .................................................................14
F. Quick Start Guide ...............................................................18
G. Service Information ..........................................................20
H. Error Codes .......................................................................20
I. Battery Back-up System (Optional) ....................................20
TABLE OF CONTENTS
4 Maintenance and Service.................21
A. Proper Shutdown Procedure ............................................21
B. Quick Reference Maintenance Chart ................................21
C. General Maintenance and Cleaning .................................22
D. Soot or Creosote Fire .......................................................26
E. High Ash Fuel Content Maintenance .................................26
5 Troubleshooting Guide ....................27
6 Service Parts Replacement .............28
A. Glass Replacement - Door Assembly ...............................28
B. Baffle Removal ................................................................28
C. Convection Blower Replacement .....................................29
E. Combustion (Exhaust) Blower Replacement ....................29
7 Reference Materials..........................30
A. Component Functions .......................................................30
B. Component Locations ........................................................32
C. Exploded Drawings............................................................33
D. Service Parts List...............................................................34
January 29, 2014 7034-276 3
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 A. Congratulations
- 4 C. Warranty Policy
- 6 1 Listing and Code Approvals
- 6 D. Electrical Rating
- 7 2 Operating Instructions
- 7 A. Fire Safety
- 9 G. Filling the Hopper with Fuel
- 9 H. Starting Your First Fire
- 10 J. Clear Space
- 10 K. Ignition Cycles
- 13 A. Introduction
- 20 G. Service Information
- 20 H. Error Codes
- 21 4 Maintenance and Service
- 21 A. Proper Shutdown Procedure
- 26 D. Soot or Creosote Fire
- 27 5 Troubleshooting Guide
- 28 6 Service Parts Replacement
- 30 7 Reference Materials
- 30 A. Component Functions
- 33 C. Exploded Drawings
- 34 D. Service Parts List