Electrical Requirements – Gas Dryer
IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
■
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this dryer be provided.
Recommended Ground Method
The dryer, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.
GROUNDING INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING:
Improper connection of the equipmentgrounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
6
Electrical Requirements – Electric Dryer
(U.S. Only)
IMPORTANT: The dryer must be electrically grounded in accordance with local codes and ordinances or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, latest edition.
The National Electrical Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
■
A four-wire or three-wire, single-phase, 120/240 volt, 60 Hz,
AC only electrical supply (or four-wire or three-wire,
120/208 volt, if specified on the model/serial rating plate) is required on a separate, 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
Recommended Ground Method
It is your responsibility to contact a qualified electrical installer to ensure that the electrical installation is adequate and in conformity with the National Electrical Code, ANSI/NFPA 70, latest edition, and all local codes and ordinances.
GROUNDING INSTRUCTIONS
■
For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
■
For a permanently connected dryer:
This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.
WARNING:
Improper connection of the equipmentgrounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 DRYER SAFETY
- 4 INSTALLATION REQUIREMENTS
- 4 Tools and Parts
- 4 Location Requirements
- 6 Electrical Requirements - Gas Dryer
- 6 Electrical Requirements - Electric Dryer (U.S. only)
- 7 Gas Supply Requirements
- 8 Venting Requirements
- 10 INSTALLATION INSTRUCTIONS – GAS DRYER
- 10 Make Gas Connection
- 10 Connect Vent
- 10 Complete Installation
- 11 INSTALLATION INSTRUCTIONS – ELECTRIC DRYER
- 11 Make Electrical Connection
- 15 Connect Vent
- 15 Complete Installation
- 15 ELECTRONIC CONTROL SETUP
- 15 MAINTENANCE INSTRUCTIONS
- 17 SÉCURITÉ DE LA SÉCHEUSE
- 19 EXIGENCES D’INSTALLATION
- 19 Outillage et pièces
- 19 Exigences d'emplacement
- 21 Spécifications électriques - sécheuse à gaz
- 21 (É.-U. seulement)
- 22 Spécifications de l’alimentation en gaz
- 23 Exigences concernant l'évacuation
- 25 INSTRUCTIONS D’INSTALLATION – SÉCHEUSE À GAZ
- 25 Raccordement à la canalisation de gaz
- 25 Raccordement du conduit d'évacuation
- 26 Achever l’installation
- 26 ÉLECTRIQUE
- 26 Raccordement électrique
- 31 Raccordement du conduit d'évacuation
- 31 Achever l’installation
- 31 RÉGLAGE DE LA COMMANDE ÉLECTRONIQUE
- 31 INSTRUCTIONS D’ENTRETIEN