SETTING & ADJUSTING DATA. Toshiba 32HFX72


Add to my manuals
111 Pages

advertisement

SETTING & ADJUSTING DATA. Toshiba 32HFX72 | Manualzz

CHAPTER 2 SPECIFIC INFORMATIONS

SETTING & ADJUSTING DATA

SAFETY INSTRUCTIONS

(A)

(B)

36"

32.7 kV

34.1 kV

HIGH VOLTAGE AT ZERO BEAM:

MAX HIGH VOLTAGE:

Table-1

SERVICE MODE

ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:

Item

SCNT

HIT

LIN

VSC

VPS2

VCP

WID

RCUT

GCUT

BCUT

GDRV

BDRV

BRTC

TNTC

SCOL

Name of adjustment

R CUTOFF

G CUTOFF

B CUTOFF

G DRIVE

B DRIVE

BRIGHT CENT

TINT CENT

SUB-COLOR

SUB-CONTRAST

HEIGHT

V-LINEARITY

V-S CORRECTION

V-SHIFT

V-COMPENSATION

PICTURE WIDTH

Preset

12H

40H

14H

36H

02H

02H

1EH

40H

40H

40H

40H

40H

80H

46H

06H

Data

Table-2

Item

PARA

CNR

TRAP

HCP

VFC

HPS

GMPS

CPAR

PHUE

PCNT

PCOL

PYOF

PIOF

PQOF

Name of adjustment

E-W PARABOLA

E-W CORNER

TRAPEZIUM

H-CONMPENSATION

V-F CORRECTION

H-POSITION

GMPS

CENTER PARA

PIP TINT

PIP CONTRAST

PIP COLOR

PIP Y OFF SET

PIP I OFF SET

PIP Q OFF SET

OPTION: (PROGRESSIVE 4:3 DV)

MODELS

36"

OPT1 (2CAH)

HEX

4AH

Table-3

OPT2(2CBH)

HEX

25H

CIRCUIT CHECKS

FAIL SAFE DET. VOLTAGE

Table-4

(C)

20.44 V

Preset

40H

0FH

19H

17H

24H

1EH

16H

13H

33H

02H

0CH

3FH

2FH

04H

Data

– 14 –