Appendx C: Dsplay characters GasMaster
Appendix C: Display characters
Message display area characters
When editing strings of text for passwords, detector location or system identity, the following characters are available:
Group1: <space> !
Group2: # $ % &
Group3: * + , - . /
Group4: 0 1 2 3 4 5 6 7 8 9
Group5: : ;
Group6: ? @
Group7: A B C D E F G H I J K L M N
O P Q R S T U V W X Y Z
Group8: _
Group9: a b c d e f g h i j k l m n o p q r s t u v w z y z
Use the Up and Down buttons as described in section 3.7 to select the required characters.
For some string types the available characters may be restricted, only the applicable characters will be shown. For example the detector name (e.g. gas type) is restricted to groups 4 and 7 (numerals and upper case) only: single clicking or holding the Up button will advance forward through the available groups of characters:
A B C D ... X Y Z 0 1 2 ... 7 8 9 A B C
... etc single clicking or holding the Down button will advance backwards through the available groups of characters:
Z Y X W ... C B A 9 8 7 ... 2 1 0 Z Y X ... etc double clicking the Up button will jump forwards to the end of the current group then on to the start of the following one etc: Z 0 9 A Z ...
double clicking the Down button will jump backwards to the start of the current group then on to the end of the following one etc: A 9 0 Z A ...
6
7
8
9
4
5
2
3
0
1
Channel display characters
NB:
The following characters represent those which can be shown on the channel display area to represent detector types.
The following characters cannot be closely represented: K, M, V, W, X
Q
R
S = 5
T
M
N
K
L
O
P
I
J
E
F
G = 9
H
C
D
A
B
W
X
U
V
Y
Z = 2 dash underscore
?
blank
b5 b6 b0
.dp
b7 b1 b3 b2 b4
Thank you for reading this data sheet.
For pricing or for further information, please contact us at our UK Office, using the details below.
UK Office
Keison Products,
P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England.
Tel: +44 (0)
330 088 0560
Fax: +44 (0)1245
808399
Email: [email protected]
Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.
advertisement
Related manuals
advertisement
Table of contents
- 5 I. Introduction
- 5 1.1 About Gasmaster
- 5 1.2 About this manual
- 6 applications
- 7 II. Installation
- 7 Please read this first
- 8 2.1 Before installation
- 8 2.2 General
- 9 2.3 Mounting
- 9 2.4 Cabling requirements
- 10 2.5 Installing gas and fire detectors
- 10 2.6 Installing output devices
- 10 2.7 Connecting mains power
- 11 2.8 Connecting input devices
- 15 2.9 Connecting output devices
- 17 2.10 Applying power
- 17 2.11 Battery back-up times
- 18 2.12 Commissioning
- 20 III. Operation
- 20 3.1 Gasmaster Operator Panel
- 22 3.2 Gasmaster start up sequence
- 22 3.3 How to adjust display contrast
- 22 number and system identity
- 23 3.5 Using the menu system
- 23 3.6 Inhibiting channels
- 24 Supervisor Mode
- 25 3.8 In the event of an alarm
- 25 3.9 In the event of a fault
- 25 3.10 System Configuration
- 27 Menu system overview
- 38 IV. Maintenance
- 38 4.1 Functional Testing
- 38 4.2 System Inhibit
- 39 4.3 Detector Calibration
- 39 4.4 Changing Batteries
- 39 4.5 Module Replacement
- 39 4.6 Event logging
- 39 4.7 Service card
- 39 4.8 Cleaning
- 40 Appendix A: Specifications
- 42 Appendix C: Display characters
- 43 Warranty Statement
- 44 Regional addresses