SYSTEM SETTINGS
From the main screen press B buttons to have access to the menu.
Use buttons A B -CD as described in the picture to navigate the menu.
The selected entry is indicated in red colour.
(According to your RATIO iX3M model some entries might not be visualized)
SYSTEM SET MENU
DISPLAY
GENERAL SET
PC MODE
DEFAULT
COMPASS
INFO
SWITCH OFF
Do you know what?:
You can change the RATIO iX3M menu, headlines and data colours from the menu DISPLAY.
A b
C D
ExIT
ENTEr UP
DOWN
40
To reach this menu from the main screen press in sequence: b b
DISPlAY SET
lEVEl: 15
DIVE:
MODE: AUTO
DATA: lAbEl: lOW: MED:
AlArM: hIgh:
TITlE: ITEM:
MENU:
SEl:
A b
ExIT NExT
C D
+
_
Display Set
To navigate the menu follow the instructions in the picture on the left.
LEVEL: Ratio iX3M luminous intensity. From 1 to 15
MODE: It activates/deactivates the automatic (AUTO) or manual (MAN)
back light mode. (if AUTO the LEVEL parametre is ignored).
ATTENTION: the light sensor is located in the screen’sleft lower corner. Do not cover it.
ATTENTION: the screen’s brightness affects considerably the device’s autonomy. We recommend to set AUTO.
COLOR CODE: The RATIO iX3M allows you to change the colour of the screen data .
DATA:
LABEL:
LOW:
HIGH:
TITLE: the Menu headlines colour
.
ITEM:
Do you know what?:
f you have any doubts on your device’s setting, you can set the company’s parametres from the menu DEFAULT
41
To reach this menu from the main screen press in sequence: b
D b
UTC:
UTC2:
TIME:
FORMAT:
DATE:
UNITS:
gENErAl SET
1:00
1:00
16:22:00
24
02.07.15
m/°C
A b
ExIT NExT
C D
+
_
To reach this menu from the main screen press in sequence: b
D D b
PC MODE
S/N : 000000
CABLE: READY
BT: READY
A
ExIT
General Set (ora e data)
To navigate the menu follow the instructions in the picture on the left.
UTC:
UTC2:
Attention: in the Logbook only the UTC is registered, not the UTC2)
TIME:
DATE:
UNITS:
PC Mode (how to connect the iX3M to PC)
To connect the iX3M to the PC install the DiveLogger (available free of charge in the web site www.ratio-computers.com/support)
1. Open the Divelogger on a PC or MAC and select the iX3M model
2.Activate the PC mode on the iX3M
3. Connect the USB cable to the iX3M and to the PC or Mac
4. Press “Settings” in the Divelogger and select the COM port
(usually the PC gives COM the higher value)
5. Press “Connect”i
In case of connectivity problems, see the video tutorial available in the “Support” section of the web site www.ratio-computers.com
42
To reach this menu from the main screen press in sequence: b
D D D b
DEFAUlT
ATTENTION
SETTINGS: NO
TISSUES: NO
EXECUTE
A
ExIT b C D
+
_
Reset to Default (reset the factory data)
To navigate the menu follow the instructions in the picture on the left.
The command SETTING resets all menu and
settings (MIX, Alarms, Colours etc.) It doesn’t reset the diver’s
tissues saturation.
Attention: NEVER EVER reset the tissue saturation if the device is always used by the
same person! This doesn’t allow the computer to carry out a correct decompressive
calculation. !
WARNING - DANGER
DO NOT reset the tissue saturation (TISSUES=YES) if the device will be always used by the same person!!!
This may cause the risk of injuries, even lethal.
It is possible to reset the tissue sauturation only if the iX3Ml device will be used by a person who does not have carried out dives during the previous 48 hours .
ATTENTION!
A possible tissue saturation reset is recorded permanently in the RATIO iX3M Logbook.
The user will be fully responsible of the tissue saturation reset.
.
43
To reach this menu from the main screen press in sequence: b
C CC C b
COMPASS SET
DECLINATION:
DIRECTION:
0.0
EAST
CALIBRATE START
A
ExIT b C D
+
_
Compass settings (Compass)
To navigate the menu follow the instructions in the picture on the left
between the geographic and the magnetic north; this factor
.can be found visiting dedicated web sites.
the magnetic field’s declination.
Do you know what?:
You can deepen your knowledge about the compass’ Direction and Declination on: https://en.wikipedia.org/wiki/Magnetic_declination
CALIBRATE:
Calibrate the compass. (see pictures below)
rOTATE TIlT
COMPASS SET
DECLINATION: 0.0
DIRECTION:
CALIBRATE
EAST
ROTATE
COMPASS SET
DECLINATION: 0.0
DIRECTION:
CALIBRATE
EAST
TILT
Turn slowly and constantly on a flat surface .
Turn the iX3M slowly and constantly on its vertical axis.
For a correct survey, carry out the calibration far from magnetic field sources i (PC, TV, light poles etc.)
44
To reach this menu from the main screen press in sequence: b
D D b
INFO
RATIO
IX3M XXXX
S/N:00000
FW: APOS 3.0.0/005
A
ExIT
To reach this menu from the main screen press in sequence: b
D b
Model, serial number and operative system.
To navigate the menu follow the instructions in the picture on the left.
In this page you can visualize: Model name, serial number (S/N) and the installed operative system version (FW).
In case you need assistance for your RATIO iX3M these data are important..
SWITCH OFF (Manual switching off).
The RATIO iX3M switches off automatically after a certain inactivity period..
However, you can also switch the device off manually.
If the device is in charge, the command will be executed only once the charge is finished.
If the device is still carrying out the tissue desaturation after a dive, the command
“switch off “ deactivates all systems which are not essential.
Nevertheless, the device goes on to carry out the desaturation calculation.
45
To reach this menu from the main screen press in sequence:
C
DIr
0°
W
NW.
0°
N
. .
E rEC
180°
A
ExIT
C D rOUTE
ATTENTION:
The Compass works correctly only if its calibration has been done correctly.
See paragraph: COMPASS
Compass
To navigate the menu follow the instructions in the picture on the left
Compass resolution: 1°
Compass accuracy: +/-1°
Do you know what?:
The RATIO iX3M is provided with the most innovative compass. Check always a compass’ resolution and accuracy before entrusting it your route .
D Button to memorise the current Route
When in “Compass” mode the iX3M shows::
DIRECTION (on the top centre): the current direction expressed in
degrees (°)
GRAPHIC COMPASS (on the centre): graphic compass with route
indications.
Direction in route (+/- 5° in comparison with the one set with D )
It indicates the direction to follow to find the route you have set
Reciprocal direction (+/- 5° in comparison with the set reciprocal route )
DIR:
Current set route
REC:
Reciprocal of the set route
Do you know what?:
The RATIO iX3M’s 3D compass is compensated by 2 accelerometres. The iX3M can compensate your arm’s grade automatically up to an angle of 85° from the horizontal position.
46
The RATIO iX3M when diving
To navigate the menu follow the instructions in the picture on the left.
When the iX3M is in the main screen or if it is switched off, it activates the dive mode automatically, once a certain depth is passed.
To dive in GAUGE or FREE mode, select the desired mode with button D before starting your dive.
Do you know what?:
With the iX3M you can set the default mode that the device must activate automatically before starting to dive, by selecting either Dive with tank (default), or Diving with Rebreather (for iX3M TECH+ and iX3M REB only), or GAUGE or FREE from the menu DIVE SET.
ADDITIONAl DATA
SETTINgS
MODE:
MIX:
GFL/GFH:
OC SET
OC
21/0 ACT
93/93
b C D
COMPASS
47
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 7 General Warnings
- 9 Danger Warning
- 11 Diving with Mix
- 12 Limits of diving computers
- 12 Care and Maintenance
- 14 Computer’s technical characteristics
- 14 Hardware
- 14 Certification
- 15 Software
- 16 Summary of technical characteristics
- 17 How to recharge the Battery
- 19 Diving in cold or freezing waters
- 20 DAN DL7
- 20 Privacy
- 21 The main screen
- 25 The RATIO iX3M Menu
- 26 MAIN MENU
- 27 DIVE SET for RATIO iX3M Deep
- 28 DIVE SET for RATIO iX3M Tech+ & iX3M Reb
- 29 DIVE SET for RATIO iX3M Tech+ & iX3M Reb
- 32 Deco Stop for RATIO iX3M Tech+ & iX3M Reb
- 33 CCR Settings for RATIO iX3M Tech+ & iX3M Reb
- 34 MIX Table
- 35 Diluent Table for RATIO iX3M Tech+ & iX3M Reb
- 36 Dive Alarms
- 37 NDL (Non Decompression Limit) Planner
- 38 Decompression Planner
- 39 Logbook
- 40 SYSTEM SETTINGS
- 41 Display Set
- 42 General Set (ora e data)
- 42 PC Mode (how to connect the iX3M to PC)
- 43 Reset to Default (reset the factory data)
- 44 Compass settings (Compass)
- 45 Model, serial number and operative system.
- 45 SWITCH OFF (Manual switching off).
- 46 Compass
- 48 Dive Screen
- 48 Main Data
- 51 Current dive’s profile:
- 51 Tissues saturation when diving: The diagram represents the 16 tissues which are taken into consideration by the two decompressive algorithms (BUL or VPM).
- 51 The yellow lines represent the nitrogen levels . The green lines represent the helium levels (if present)
- 52 Decompression Chart:
- 53 Compass when diving
- 54 Applications when diving
- 55 Mix change during the dive
- 56 Setting change during the dive