SNMP-1000 User`s Manual


Add to my manuals
90 Pages

advertisement

SNMP-1000 User`s Manual | Manualzz

4.5.4 CPU Card

r514 r505 r515 r506 r516 r507 r517 r512 r503 r513 r504 r414 r501 r511 r502 r412 r403 r413 r404

Command r401 r411 r402

CPU 2

CPU 1

CPU 2

CPU 1

CPU 2

CPU 1

CPU 2

CPU 1

Device

CPU 1

CPU 2

CPU 1

CPU 2

CPU 1

CPU 2

CPU 1

CPU 2

CPU 1

CPU 2

CPU 1

CPU 2

CPU 1

CPU 2

51

50

51

51

50

51

50

51

50

51

50

41

50

51

50

41

40

41

40

Device Code Device Sub-Item Device Sub-Code

40 Low Limit 1

41

40 Alarm Level 2

Event Output

Current Speed

3

4

High Limit

High Alarm

Level

High Event Output

Low Limit

1

2

3

4

Low Alarm Level

Low Event Output

Current Temp.

5

6

7

55 Chapter 4

Device

CPU 1 Vcore

CPU 2 Vcore

CPU VI/O

CPU card +5V

CPU card -5V

CPU card +12V

CPU card -12V

CPU 1 Vcore

CPU 2 Vcore

CPU VI/O

CPU card +5V

CPU card -5V

CPU card +12V

CPU card -12V

CPU 1 Vcore

CPU 2 Vcore

CPU VI/O

CPU card +5V

CPU card -5V

CPU card +12V

CPU card -12V r613 r623 r633 r643 r653 r663 r642 r652 r662 r603 r602 r612 r622 r632 r631 r641 r651 r661

Command r601 r611 r621

61

62

63

64

65

66

64

65

66

60

60

61

62

63

63

64

65

66

Device Code

60

61

62

Device Sub-Item

High Limit

Low Limit

Alarm Level

Device Sub-Code

1

2

3

SNMP-1000 User’s Manual 56

r625 r635 r645 r655 r665 r654 r664 r605 r615

Command r604 r614 r624 r634 r644

Device

CPU 1 Vcore

CPU 2 Vcore

CPU VI/O

CPU card +5V

CPU card -5V

CPU card +12V

CPU card -12V

CPU 1 Vcore

CPU 2 Vcore

CPU VI/O

CPU card +5V

CPU card -5V

CPU card +12V

CPU card -12V

62

63

64

65

66

65

66

60

61

Device Code

60

61

62

63

64

Device Sub-Item

Event Output

Current Voltage

Device Sub-Code

4

5

Command Device w401xxxx w411xxxx w402x

CPU 1

CPU 2

CPU 1 w412x CPU 2

Device

Code

40

41

40

Device

Sub-Item

Low Limit

Alarm

Level

Device

Sub-Code

1

Value(xxxx)

1000~9999

2

41 3

4

1

2

5

Remark

RPM in

ASCII

Not used

No Alarm

Critical

Major

Minor

57 Chapter 4

Command w403x w413x

Device

CPU 1

CPU 2

Device

Code

40

Device

Sub-Item

Event

Output

41

Device

Sub-Code

3

Value(xxxx)

4

5

6

1

2

3

Remark

None

Power Off

DO 0

DO 1

DO 2

DO 3

Command Device w501xxxxx w511xxxxx

CPU 1

CPU 2 w502x w512x w503x w513x w504xxxxx w514xxxxx

CPU 1

CPU 2

CPU 1

CPU 2

CPU 1

CPU 2

Device

Code

50

51

Device

Sub-Item

High

Limit

Device

Sub-Code

1

50 High

Alarm

Level

2

Value(xxxx) Remark

-55~125 (°C) or

-67~257 (°F)

1

Temperature value in ASCII, degree C or F depends on system setting, max. 5 characters, incl. "-", "."

Not used

51

50

51

50

51

High

Event

Output

Low Limit

3

4

4

5

2

3

3 Critical

4 Major

5 Minor

1 None

6

-55~125 (°C) or

-67~257 (°F)

Power Off

DO 0

DO 1

DO 2

DO 3

Temperature value in ASCII, degree C or F depends on system setting max.

5 characters, incl. "-", "."

SNMP-1000 User’s Manual 58

Command Device w505x CPU 1 w515x w506x w516x

CPU 2

CPU 1

CPU 2

Device

Code

50

Device

Sub-Item

Low

Alarm

Level

51

Device

Sub-Code

5

50

51

High

Event

Output

6

Value(xxxx) Remark

1 Not used

3

4

1

2

5

6

3 Critical

4 Major

5 Minor

None

Power Off

DO 0

DO 1

DO 2

DO 3

59 Chapter 4

Command Device w601xxxxxx w611xxxxxx w621xxxxxx w631xxxxxx w641xxxxxx w651xxxxxx w661xxxxxx w602xxxxxx w612xxxxxx w622xxxxxx w632xxxxxx w642xxxxxx w652xxxxxx w662xxxxxx

CPU 1

Vcore

CPU 2

Vcore

CPU VI/O

CPU card

+5V

CPU card

-5V

CPU card

+12V

-12V

CPU 1

Vcore

CPU 2

Vcore

CPU VI/O

CPU card

+5V

CPU card

-5V

CPU card

+12V

CPU card

-12V

61

62

63

64

65

66

60

61

62

63

64

65

66

Device

Code

60

Device

Sub-Item

High Limit

Low Limit 2

Device

Sub-Code

1

Value(xxxx)

-15 ~ 15

Remark

Voltage value in

ASCII code, max. 6 characters, incl.

"-", "."

SNMP-1000 User’s Manual 60

w653x w663x w604x w614x w624x w634x w644x w654x w664x

Command w603x w613x w623x w633x w643x

Device

CPU 1

Vcore

CPU 2

Vcore

CPU VI/O

CPU card

+5V

CPU card

-5V

CPU card

+12V

CPU card

-12V

CPU 1

Vcore

CPU 2

Vcore

CPU VI/O

CPU card

+5V

CPU card

-5V

CPU card

+12V

CPU card

-12V

65

66

60

61

62

63

64

65

66

Device

Code

60

Device

Sub-Item

Alarm

Level

61

Event

Output

4

Device

Sub-Code

3

Value(xxxx)

1

Remark

Not used

3

4 Major

5 Minor

1

2

3

4

5

6

Critical

None

Power Off

DO 0

DO 1

DO 2

DO 3

Command r701 r711 r721 r731

Device

Power 1

Power 2

Power 3

Power 4

Device Code

70

71

72

73

Device Sub-Item

Normal Level

Device Sub-Code

1

61 Chapter 4

r713 r723 r733 r704 r714 r724 r734

Command r702 r712 r722 r732 r703

Power 2

Power 3

Power 4

Power 1

Power 2

Power 3

Power 4

Device

Power 1

Power 2

Power 3

Power 4

Power 1

71

72

73

71

72

73

70

Device Code

70

71

72

73

70

Device Sub-Item

Alarm Level

Event Output

Current Status

Device Sub-Code

2

3

4

Command Device w701x w711x w721x w731x w702x w712x w722x w732x

Power 1

Power 2

Power 3

Power 4

Power 1

Power 2

Power 3

Power 4

72

73

70

71

Device

Code

70

71

72

73

Device

Sub-Item

Normal

Level

Device

Sub-Code

1

Value (x)

1

Remark

High

2 Low

Alarm

Level

2 1

2

3

4

Not used

No Alarm

Critical

Major

5 Minor

SNMP-1000 User’s Manual 62

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents