Understanding Total Connect Services. Honeywell Direct
Anúncio
Anúncio
AlarmNet Direct Online Help Guide
Understanding Total Connect Services
The “Total Connect” suite of services provides additional flexibility to a powerful Honeywell security system. Because these services utilize various communication technologies outside of our control, the user should be aware how these impact the use of Total Connect. These services are intended as a convenience for the user, and do not replace Central
Station reporting of critical events (alarms, troubles, etc.).
In addition, Honeywell provides many different control panel families, each having different feature sets. The current release of “Total Connect” services provides the most consistent operation when used with our Vista-10P/15P/20P series of panels. These services also function with our residential LYNX panels, and commercial Vista panels; namely the Vista-
128BP class. However, there are some inconsistencies to be aware of. This topic provides helpful hints relative to the use of these new services.
General
Total Connect account creation
When programming a new GSM, IGSM or creating a Total Connect only (i.e., video services only) account the wizard will prompt you for the following information:
Account Name – Must be at least 8 characters.
TC2 Master user name – This is the "Username" for the customer to use when logging into
Total Connect. Can be 6-80 character length (not case sensitive), valid entries are: 0-9, A-Z and ? ! @ # $ % ^ * - _ = + .
TC2 Email address – This is the email address provided by your customer. Your customer will receive a welcome email which contains the Total Connect 2.0 URL and username. They will also receive a second email containing their auto-generated password to login to Total
Connect. auto stay arm service providers web browser
*** PLEASE NOTE ***
The “Master User” profile is not intended for your use”.
The “Master User” profile is intended to be managed by your customer. After initial setup in
AlarmNet Direct, the user profile will be maintained by the customer through their Total
Connect website account. They can update and change their profile and assign subordinate user profiles via the Users module.
*** TECHNICAL TIP ***
In certain instances your customer may need hands on help to configure their Total Connect website account. If you are asked to make changes on your customers behalf another level of
“Security Professional Access” is available. Have your customer (Master User Only):
1. Login to the Total Connect 2.0 web site.
2. Grant you access to their account by clicking; My Profile > then checking “Security
Professional Access” (confirm the pop-up security message) > then click “Save”.
3. You will now have access up to 60 minutes to edit fields by accessing the account.
Refer to the “
Checking the customer’s TC2 account configuration
” topic in this guide.
If the security system (or a partition) is configured with Auto Stay Arm enabled, using
Remote Access or SMS to arm the system will result in the system (or partition) reverting to an
Armed Stay state. This is because there is no detection that the premises has been vacated
(complies with SIA requirements).
Our remote services features are dependent upon the reliability and capability of the user's service provider for the internet as well as the wireless carrier that may be involved. All networks are subject to outages and maintenance beyond our control, and as such, can prevent availability of connections or cause disruptions to the services.
Configure your web browser to always allow "pop-ups" from the
services.alarmnet.com
site.
– 38 –
AlarmNet Direct Online Help Guide
control panel partition support
At this time, Total Connect 2.0 does not support control panel partitions two through eight.
Partition support is limited to Partition One, even on panels that have more than one partition enabled.
When using Total Connect 2.0 on multi-partitioned panels:
1. Only zones assigned to partition one can be uploaded into Total Connect 2.0.
2. Notifications can be sent for events occurring on partition one only. This would apply to ALL events including; Alarm, Arming/Disarming, and zone notifications such as bypass or trouble.
3. The Quick Arm/Disarm buttons will arm/disarm partition one only.
4. The Total Connect 2.0 remote keypad MUST be assigned to partition one only, however, the remote keypad DOES support the Global Arming and GOTO functions (if enabled properly in the panel programming). Those functions will give the end user the ability to control other partitions on the system just like any keypad physically connected to the system.
5. System Status is provided for partition one only.
When using Total Connect 2.0 User code synchronization on multi-partitioned panels:
E-Mail event notifications
1. User Sync via Total Connect 2.0 is designed for use with user codes assigned to partition one only. User codes created via control panel keypad or Compass must have access to partition one for the code to be uploaded into Total Connect 2.0.
2. Users created via Total Connect 2.0 and assigned a user code for the control panel will be given “General authority” access to ALL enabled partitions when User Sync is performed. Caution must be exercised here so as to not give a user access to a partition they should not have access too. It is highly recommended to observe notes
3 and 4 below on multi-partitioned panels.
3. User codes originally created via control panel keypad or Compass will continue to function only in the partitions they were given access to when they were programmed, even after Total Connect 2.0 User sync is performed. These codes do not get assigned to all partitions when Sync is performed and will continue to work in the assigned partitions only.
4. On multi-partitioned panels, the best practice would be to program the user codes into the panel first, then use the User Sync function to pull the codes into Total
Connect 2.0.
After the “Panel Only Users” are uploaded, modify them to create Total Connect 2.0
Users as desired (assign a login name and password, first/last name, email address, etc). It is recommended to follow this procedure in order to prevent giving undesired partition access to a Total Connect User.
For event notifications, if no text has been added to describe the event on the Total Connect website (refer to the Configure Email topic in the Total Connect User Guide), a generic message (such as “Zone 1 Activated”) will be sent for the activated state.
LYNXR-I, LYNX Plus, and LYNX Touch fire zones Do not use email notification for zones configured as "Fire with verification." panic keys time and date
The emulated keypad does not support single-button or two-button panic keys.
You cannot set the time and date or go into programming mode remotely.
Remote Access common partition deleting users
Common Partition logic will work from the emulated keypad but not from the System Status screen.
If you delete a user at the security system's control panel, when using Remote Access to
Manage User Codes, the deleted user can still be retrieved since it is stored in the remote services database. If desired, delete that user from the remote services database (Remote
Access > Users > Manage User Codes).
– 39 –
AlarmNet Direct Online Help Guide
fire zones, bypassing When using Remote Access, if you attempt to bypass a fire zone, the fire zone WILL NOT be bypassed. keypad – full control When using Remote Access, if the keypad type is set to “Full Control,” you may view status and control all partitions using the “System Status” tab (not the “Keypad” tab). panic keys When using Remote Access, two-button panic keys such as 1+, +#, and 3+# will not work. However single button panics (if programmed) will work. stay mode The System Status screen does not support multiple stay modes. If you need to use a specific stay mode, use the Keypad screen. system status screen The System Status screen does not support multiple stay modes. If you need to use a specific stay mode, use the Keypad screen. system status screen The System Status screen may not show all conditions (e.g., when the security system's dialer has been shut down). However, the Keypad screen will show all conditions. Please check the
Keypad screen if you feel the System Status screen is not accurate. zone descriptors The security system's zone descriptor information will only be copied to the Remote Services database if there is no zone descriptor in its database for a particular zone. The descriptor in the database takes precedence over what might be in the security system control panel.
If you want to copy the zone descriptor that is in the control panel, simply delete the zone descriptor from the database (Remote Access >Setup > Name Zones), then click Save Zone
Names. When you start another session, the zone type, along with its descriptive name, is retrieved from the control panel.
Text Message or SMS Commands (TC1 only)
"Command issued, status unknown" reply message
When the network does not have sufficient information from the control panel to formulate a message in response to a command, instead of sending a "blank" reply message, it will send
"Command issued, status unknown" to alert the user to retry getting status. Likewise, if the control panel information is not available at the time that the remote services application collects the status, the text message reply may be truncated. commands
GOTO command multiple text message series out of order replies output relay
When a Remote Access session is active (using a PC), text message commands cannot be used to control the security system. If you desire to do text messaging, please shutdown the remote PC session and wait 15 seconds prior to sending a text command.
SMS Text Message commands do not support the GOTO command (applies to partitioned systems only).
When the need or desire arises to send a series of text message commands, allow a 2-minute period after the reply of the first text message before sending the next text message.
Under certain network conditions, emails received by the user may be out of order. partition number
You will not receive text message verification for turning an output relay on or off. You will, however, receive a system status message.
If you do not see the partition number in a reply message, contact your security system services provider to enable the control panel's “Display Partition Number” field. remote keypad – Full
Control remote keypad –
Keypad Only short codes
If the remote keypad is set to “Full Control,” sending a text message command for arming or disarming a partitioned system without specifying a partition constitutes a global command for all partitions. If the user does not have global authorization, no action will be performed.
Please make sure this is understood by the user when offering this service.
If the remote keypad is set to "Keypad Only," sending a text message command for arming or disarming a partitioned system without specifying a partition will affect only the partition the keypad is assigned to. Likewise, only the status of the partition assigned to the remote keypad will be retrieved.
Some wireless carrier service plans do not fully support SMS Text Message commands with short codes. While this is rare, the Total Connect service may not work with certain plans from your current carrier. Please consult with your carrier if this happens as you may need to upgrade your wireless plan to one that supports short codes.
– 40 –
AlarmNet Direct Online Help Guide
text message commands text message verification text messaging service
When a Remote Access session is active (using a PC), text message commands cannot be used to control the security system. If you desire to do text messaging, please shutdown the remote PC session and wait 15 seconds prior to sending a text command.
You will not receive text message verification for turning an output relay on or off. You will, however, receive a system status message.
Currently, the SMS Text Message command service operates in conjunction with a wireless service hosting company to support the short code used by Honeywell, which is “ALARM” or
25276. This hosting service covers the vast majority of carriers supporting SMS service today.
Whereas we realize the supported list is very broad, if for some reason the short code does not work with your wireless carrier, please contact them for assistance.
Trouble Messages
"Console ECP:2" message
If the following screen appears, contact your security system services provider to program the control panel with the Remote Access keypad address that exists in the radio.
"Panel Failed to
Respond" message
Status Unavailable
1000 message
If, while using the SMS text message command feature, you receive a "Panel Failed to
Respond, Please Retry" message, it may be a result of heavy network traffic, or the panel is busy responding to another Remote Access user. Please wait a minute and then try again.
Error 1000 is caused the lack of PSD (Panel Security Data) being sent from the Control Panel to
Total Connect 2.0. There are a few causes, such as; no initial PSD received, incorrect Control
Panel programming, or incorrect AlarmNet Direct programming.
To resolve this issue, try the following:
1. Arm and disarm the security system. This will force the PSD message to be sent if everything is programmed properly.
2. Ensure the following Control Panel settings are programmed:
• For all control panels, verify “RIS” or “Delayed Reports” is enabled.
• For Vista 15/20 control panels, verify field 91 is programmed to 8, 2. (In AlarmNet
Direct, the Device must be set to 25.)
• For Vista Turbo control panels, one ECP address (recommended address 25) needs to be set to Type 12 RIS. Also in AlarmNet, the Device multimode address must match the multimode Device programmed in the control panel.
• For LYNX series controls, verify the “Remote Access” is Enabled and “Email
Notifications” are set to Total Connect 2.0 (Enhanced Rpts) in AlarmNet Direct.
3. Ensure the following AlarmNet Direct settings are programmed.
• For GSMV/IGSMV/GSMX and 7847i communicators, ensure “Remote Access” Enabled and “Email Notifications” are set to Total Connect 2.0 (Enhanced Rpts) and MultiMode
Address is either 25 for Vista 10/15/20 or matches the panel for Vista Turbo.
– 41 –
AlarmNet Direct Online Help Guide
• For LYNX series controls, verify the “Remote Access” is Enabled and “Email
Notifications” are set to Total Connect 2.0 (Enhanced Rpts) in AlarmNet Direct.
VISTA commercial
4. After verifying the AlarmNet Direct device programming, ensure that the data is in the device by performing a “Send Data” command from the “Show Programmed Devices” page of AlarmNet Direct.
5. Verify the “Transferred Date(ET)” shows a recent date and time and the arrow indicates down.
6.
If you still have the Error 1000 ensure the control panel and AlarmNet device revision levels are support Total Connect 2.0. (Refer to the “
Total Connect 2.0 Compatible
Devices
” topic in this help guide.)
7.
If this issue has not been cleared, Contact AlarmNet Technical Support.
arming command fire zone
When sending an arm text message command to a commercial panel with zero exit delay and a bypassed zone, the text message reply may not display that a zone is bypassed.
If a fire zone is in a trouble condition (with all partitions disarmed), and you attempt to send a text message command to globally Arm Away, the reply message will indicate that all partitions are Armed Away, but may not indicate a fire trouble. output relay sluggish response
Even if a programmed output relay is restricted from being accessed in the control panel, its operation will function when commanded by an SMS text message.
For security systems that are heavily populated with a large number of zones and wireless devices, etc., the Remote Access response may be sluggish.
VISTA residential restart exit delay If the Restart Exit Delay field (91) is enabled, sending text message commands to a residential control panel (e.g., Vist-10P, Vista-15P), may put the panel in an exit delay countdown condition before a successful completion of the command is sent.
– 42 –
Download