2

Type overview

VEGAFLEX 81

Cable version

Type overview

VEGAFLEX 81

Rod version

VEGAFLEX 81

Coax version

Applications

Max. measuring range

Probe

Process fitting

Process temperature

Process pressure

Measuring accuracy

Signal output

Indication/Adjustment

Approvals

Storage tanks, liquids with agitated surface

75 m (246 ft)

Cable probe

ø

2 mm

ø

4 mm

Thread from G¾, ¾" NPT or flanges from DN 25, 1"

-40 … +200 °C (-40 … +392 °F)

-1 … +40 bar/-100 … +4000 kPa (-

-14.5 … +580 psig) l l l l l

±

2 mm

4 … 20 mA/HART two-wire

4 … 20 mA/HART - four-wire

Profibus PA

Foundation Fieldbus

Modbus, Levelmaster protocol l l l l

PLICSCOM

PACTware

VEGADIS

81

VEGADIS

62 l l l l l l l

ATEX

IEC

Shipbuilding

Overfill protection

FM

CSA

Gost

Storage tanks, liquids with smooth surface

6 m (19.69 ft)

Rod probe

ø

8 mm

ø

12 mm

Thread from G¾, ¾" NPT or flanges from DN 25, 1"

-40 … +200 °C (-40 … +392 °F)

-1 … +40 bar/-100 … +4000 kPa (-

-14.5 … +580 psig)

±

2 mm

Storage tanks, liquids with low dielectric constant, vessel with installations

6 m (19.69 ft)

Coax probe

ø

21.1 mm

ø

42.2 mm

Thread from G¾, ¾" NPT or flanges from DN 25, 1"

-40 … +200 °C (-40 … +392 °F)

-1 … +40 bar/-100 … +4000 kPa (-

-14.5 … +580 psig)

±

2 mm

Guided Wave Radar – Level and interface measurement in liquids

5

6

VEGAFLEX 83

Cable version

Type overview

VEGAFLEX 83

Rod version

VEGAFLEX 83

Rod version - Foodstuffs

Applications

Aggressive and corrosive liquids

Max. measuring range

Probe

32 m (105 ft)

Cable probe

ø

4 mm

PFA coated

Process fitting/Material

Flanges from DN 25, 1" or hygienic connections

PTFE-TFM 1600

Process temperature

-40 … +150 °C (-40 … +392 °F)

Process pressure

Deviation

Signal output

Indication/Adjustment

Approvals

-0.5 … +16 bar/-50 … +1600 kPa (-

-7 … +232 psig) l l l l l

±

2 mm

4 … 20 mA/HART two-wire

4 … 20 mA/HART - four-wire

Profibus PA

Foundation Fieldbus

Modbus, Levelmaster protocol l l l l

PLICSCOM

PACTware

VEGADIS

81

VEGADIS

62 l l l l l l l

ATEX

IEC

Shipbuilding

Overfill protection

FM

CSA

Gost

Aggressive and corrosive liquids

4 m (13.12 ft)

Rod probe

ø

10 mm

PFA coated

Flanges from DN 25, 1" or hygienic connections

PTFE-TFM 1600

-40 … +150 °C (-40 … +302 °F)

-0.5 … +16 bar/-50 … +1600 kPa (-

-7 … +232 psig)

±

2 mm

Hygienic applications in the food processing and pharmaceutical industry

4 m (13.12 ft)

Rod probe

ø

8 mm

Polished version (Basle Standard)

Hygienic fittings

-20 … +150 °C (-4 … +302 °F)

-1 … +40 bar/-100 … +4000 kPa (-

-14.5 … +580 psig)

±

2 mm

Guided Wave Radar – Level and interface measurement in liquids

VEGAFLEX 86

Cable version

Type overview

VEGAFLEX 86

Rod version

VEGAFLEX 86

Coax version

Applications

Max. measuring range

Probe

Process fitting

Process temperature

Process pressure

Deviation

Signal output

Indication/Adjustment

Approvals

High temperature applications

75 m (246 ft)

Cable probe

ø

2 mm

ø

4 mm

Thread G1½ or flanges from DN 40,

2"

High temperature applications

6 m (19.69 ft)

Rod probe

ø

16 mm

Thread G1½ or flanges from DN 40,

2"

High temperature applications

6 m (19.69 ft)

Coax probe

ø

42.2 mm

Thread G1½ or flanges from DN 40,

2"

-196 … +450 °C (-321 … +842 °F) -196 … +450 °C (-321 … +842 °F) -196 … +450 °C (-321 … +842 °F)

-1 … +400 bar/-100 … +40000 kPa

(-14.5 … +5800 psig)

±

2 mm l l l l l

4 … 20 mA/HART two-wire

4 … 20 mA/HART - four-wire

Profibus PA

Foundation Fieldbus

Modbus, Levelmaster protocol l l l l

PLICSCOM

PACTware

VEGADIS

81

VEGADIS

62 l l l l l l l

ATEX

IEC

Shipbuilding

Overfill protection

FM

CSA

Gost

-1 … +400 bar/-100 … +40000 kPa

(-14.5 … +5800 psig)

±

2 mm

-1 … +400 bar/-100 … +40000 kPa

(-14.5 … +5800 psig)

±

2 mm

Guided Wave Radar – Level and interface measurement in liquids

7