Auto Mode

In order to select Color change and Color fade, set DIP switch 9 and 10 to OFF. Set DIP switches 1 – 6 to

OFF as well.

Speed can be adjusted via DIP switches 7 and 8.

In order to select Static colors and flash, set DIP switch 9 and 10 to OFF. Set DIP switches 7 and 8 to OFF as well.

DIP switch 1 to 3 control the color settings.

DIP switch 4 to 6 control the flash settings.

Sound Control

In order to select Sound controlled color change, set DIP switch 9 to ON and DIP switch 10 to OFF.

DMX-CONTROLLED OPERATION

You can control the spots individually via your DMX-controller. Every DMX-channel has a different occupation with different features.

For DMX-controlled operation set DIP Switch 10 to ON.

Addressing the device

Each device occupies 5 channels. To ensure that the control signals are properly directed to each device, the device requires addressing. This is to be adjusted for every single device by changing the DIP switches as set out in the table below.

The starting address is defined as the first channel from which the device will respond to the controller.

Please make sure that you do not have any overlapping channels in order to control each device correctly and independently from any other fixture on the DMX data link. If two, three or more devices are addressed similarly, they will work similarly.

Occupation of the DIP-switches:

Controlling:

After having addressed all LED T-36 RGB Spots, you may now start operating these via your lighting controller.