Heating circuit 1, heating circuit 2, heating circuit 3/Group. Viessmann Vitodens 200-W System
Add to my manuals
148 Pages
Viessmann Vitodens 200-W System is a wall-mounted gas condensing boiler designed for residential and commercial applications. It is highly efficient, with a Seasonal Efficiency of up to 98%. The system is also very quiet, with a sound level of only 35 dB(A). The Vitodens 200-W System is easy to install and maintain, and it comes with a comprehensive warranty.
advertisement
Code 1
Solar/Group "4"
(cont.)
Coding in the delivered condition
Extended control functions
20:0 No extended control functions enabled
Possible change
20:1
20:2
20:3
20:4
20:5
20:6
20:7
20:8
20:9
Auxiliary function for DHW heating
Differential temperature control 2
Differential temperature control 2 and auxiliary function
Differential temperature control 2 for central heating backup
Thermostat function
Thermostat function and auxiliary function
Solar heating via external heat exchanger without additional temperature sensor
Solar heating via external heat exchanger with additional temperature sensor
Solar heating of two DHW cylinders
Heating circuit 1, heating circuit 2, heating circuit 3/Group "5"
Select "Heating circuit ..." for weather-compensated control units (see page 41).
Select "5" for constant temperature control units (see page 41).
47
Code 1
Heating circuit 1, heating circuit 2, heating…
(cont.)
Coding
Coding in the delivered condition
DHW priority
A2:2 Cylinder priority applicable to heating circuit pump and mixer
Possible change
A2:0
A2:1
A2:3 to
A2:15
Without cylinder priority applicable to heating circuit pump and mixer
Cylinder priority only applicable to mixer
Reduced priority applied to mixer (the heating circuit receives a reduced amount of energy)
Summer eco function outside temperature
A5:5 With heating circuit pump A5:0 logic function (economy circuit): Heating circuit pump "OFF" when the outside temperature (AT)
A5:1 to
A5:15 is 1 K higher than the set room temperature (RT set
)
AT > RT set
+ 1 K (only for weather-compensated control units)
Without heating circuit pump logic function
With heating circuit pump logic function: Heating circuit pump "OFF" (see the following table)
5
6
7 to
15
2
3
4
Parameter address
A5:...
1
With heating circuit pump logic function: Heating circuit pump "OFF"
AT > RT set
+ 5 K
AT > RT set
+ 4 K
AT > RT set
+ 3 K
AT > RT set
+ 2 K
AT > RT set
+ 1 K
AT > RT set
AT > RT set
AT > RT set
- 1 K
- 9 K
48
Code 1
Heating circuit 1, heating circuit 2, heating…
(cont.)
Coding in the delivered condition
Summer eco function absolute
A6:36 Extended economy function disabled (only for weather-compensated control units)
Possible change
A6:5 to
A6:35
Extended economy control enabled, i.e. the burner and heating circuit pump will be switched OFF and the mixer closed at a variable adjustable value between 5 and 35 °C plus 1 °C. Base value is the adjusted outside temperature. This value is based on the actual outside temperature and a time constant that takes the cooling down of an average building into consideration.
Mixer eco function
A7:0 Without mixer economy function (only for a weather-compensated control unit and heating circuit with mixer)
A7:1 With mixer economy function (extended heating circuit pump logic):
Heating circuit pump also
"OFF":
■ If a mixer has been closed for longer than
20 min.
Heating pump "ON":
■ If the mixer changes to control function
■ If there is a risk of frost
Pump idle time, transition red. mode
A9:7 With pump idle time:
Heating circuit pump
"OFF" if the set value changes through a change in operating mode or through a change in the set room temperature (only for weather-compensated control units)
A9:0
A9:1 to
A9:15
Without pump idle time
With pump idle time; adjustable from 1 to 15
49
Code 1
Heating circuit 1, heating circuit 2, heating…
(cont.)
Coding in the delivered condition
Flow temperature minimum limit
C5:20 Electronic minimum flow temperature limit 20 °C
(only for weather-compensated control units)
Possible change
C5:1 to
C5:127
Minimum limit adjustable from 1 to 127 °C (limited by boiler-specific parameters)
50
Code 1
Heating circuit 1, heating circuit 2, heating…
(cont.)
Coding in the delivered condition
Flow temperature maximum limit
C6:74 Electronic maximum flow temperature limited to
74 °C (only for weathercompensated control units)
Heating program - changeover
d5:0 The external heating program changeover changes the heating program to "Constant operation with reduced room temperature" or "Standby mode" (only for weathercompensated control units)
Possible change
C6:10 to
C6:127 d5:1
Ext. heating program changeover to heating circuit
d8:0 No heating program d8:1 changeover via extension
EA1 d8:2 d8:3
Maximum limit adjustable from 10 to 127 °C (limited by boiler-specific parameters)
The external heating program changeover changes to "Constant operation with standard room temperature" (independent of coding address 3A, 3b and
3C)
Heating program changeover via input DE1 at extension EA1
Heating program changeover via input DE2 at extension EA1
Heating program changeover via input DE3 at extension EA1
Max. pump speed in standard mode
E6:...
Maximum speed of the variable speed heating circuit pump in % of the max. speed in standard mode. Value is defaulted by boiler-specific parameters (only for weathercompensated control units).
E6:0 to
E6:100
Maximum speed adjustable from 0 to 100 %
51
Code 1
Heating circuit 1, heating circuit 2, heating…
(cont.)
Coding in the delivered condition
Min. pump speed
E7:30 Minimum speed of the variable speed heating circuit pump: 30 % of the maximum speed (only for weather-compensated control units)
Screed function
F1:0 Screed drying function disabled (only for weather-compensated control units)
Possible change
E7:0 to
E7:100
F1:1 to
F1:6
F1:15
Minimum speed adjustable from 0 to 100 % of the maximum speed
Screed drying function adjustable in accordance with 6 optional temperature/time profiles (see
Constant flow temperature
20 °C
Party mode time limit
F2:8 Time limit for party mode or external heating program changeover via key:
8 h (only for weathercompensated control units)
*1
Pump control in "Only DHW"
F6:25 In the "DHW only" operating mode, the circulation pump in the heating circuit connection set is permanently ON (only for constant temperature control units)
F2:0
F2:1 to
F2:12
F6:0
F6:1 to
F6:24
No time limit for party mode to 12h
*1
Time limit adjustable from 1
*1
In the "DHW only" operating mode, the circulation pump in the heating circuit connection set is permanently OFF
In the "DHW only" operating mode, the circulation pump in the heating circuit connection set will be started 1 to 24 times per day for
10 min respectively
*1 Party mode ends automatically in the "Heating and DHW" program, when the system changes over to operation with standard room temperature.
52
Code 1
Heating circuit 1, heating circuit 2, heating…
(cont.)
Coding in the delivered condition
Pump control in "Standby mode"
F7:25 In the "Standby" operating mode, the circulation pump in the heating circuit connection set is permanently ON (only for constant temperature control units)
Possible change
F7:0
F7:1 to
F7:24
In the "Standby" operating mode, the circulation pump in the heating circuit connection set is permanently
OFF
In the "Standby" operating mode, the circulation pump in the heating circuit connection set will be started 1 to 24 times per day for
10 min respectively
Start temperature raising
F8:-5 Temperature limit for terminating the reduced mode -5 ºC, see example
Observe the setting of coding address "A3" (only for weather-compensated control units)
End temperature raising
F9:-14 Temperature limit for raising the reduced set room temp. -14 ºC, see exam-
weather-compensated control units)
Increase set flow temperature
FA:20 Raising the set boiler water temperature or the set flow temperature when changing from operation with reduced room temperature to operation with standard room temperature, by
20 %. See example on
weather-compensated control units)
F8:+10 to
F8:-60
F8:-61
F9:+10 to
F9:-60
FA:0 to
FA:50
Temperature limit adjustable from
+10 to -60 °C
Function disabled
Temperature limit for raising the set room temperature to the value selected for standard mode adjustable from
+10 to -60 °C
Temperature rise adjustable from 0 to 50 %
53
Code 1
Heating circuit 1, heating circuit 2, heating…
(cont.)
Coding in the delivered condition
Duration set flow temperature increase
Possible change
Fb:30 Duration for raising the set boiler water temperature or the set flow temperature (see coding address "FA") 60 min.
See example on
weather-compensated control units)
Fb:0 to
Fb:150
Duration adjustable from 0 to 300 min; one step
≙ 2 min
54
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Seasonal Efficiency of up to 98%
- Sound level of only 35 dB(A)
- Easy to install and maintain
- Comprehensive warranty
Related manuals
Frequently Answers and Questions
What is the efficiency of the Vitodens 200-W System?
How quiet is the Vitodens 200-W System?
Is the Vitodens 200-W System easy to install and maintain?
advertisement
Table of contents
- 41 Calling up coding level
- 42 General/Group
- 44 Boiler/Group
- 45 DHW/Group
- 46 Solar/Group
- 47 Heating circuit 1, heating circuit 2, heating circuit 3/Group
- 55 Calling up coding level
- 56 General/Group
- 65 Boiler/Group
- 66 DHW/Group
- 69 Solar/Group
- 76 Heating circuit 1, heating circuit 2, heating circuit 3/Group
- 86 Calling up the service menu
- 86 Diagnosis
- 92 Checking outputs (relay test)
- 95 Fault display
- 97 Fault codes
- 109 Repairs
- 117 Constant temperature control unit
- 118 Weather-compensated control unit
- 119 Internal extensions (accessories)
- 121 External extensions (accessories)
- 125 Control functions
- 132 Assigning the heating circuits to the remote control
- 132 Electronic combustion controller
- 134 Connection and wiring diagram – internal connections
- 135 Connection and wiring diagram – external connections
- 137 Parts lists
- 143 Specification
- 144 Declaration of conformity
- 144 Manufacturer's certificate according to the 1st BImSchV [Germany]
- 145 Keyword index