2.6.4 Connecting Asynchronous Modems

You can connect up to eight asynchronous modem lines to the CXY08 module. To connect a modem to a CXY08 module, see Figure 2–22 and perform the following:

1.

Find the BC19N–12 cable (see Figure 2–21).

Figure 2–21: BC19N-12 Cable

MLO-007134

2.

Feed the socket end of the cable under the cable management bracket from the back of the cabinet and insert it into the CXY08 module connector (see Figure 2–22).

Installation 2–37

Figure 2–22: CXY08 Module Connector

• If you are going to use both BC19N–12 cables, connect the first cable to the connector labeled 4–7 on the CXY08 module cover.

• If you are going to use only one cable, connect the cable to the connector labeled 0–3.

2–38 Installation

3.

Lock the connector into place with the bail latches.

4.

Attach one to four modems to the connectors at the opposite end of the cable.

If you want to place the modem farther away from the system, attach a BC22F extension cable between the cable assembly and the modem

(see Figure 2–23).

Refer to the modem documentation for the location of the connector, and for instructions on using the modem.

Figure 2–23: BC22F Extension Cable

Extension Cable

MLO-007189

Repeat the same procedure for connecting a second BC19N cable, except insert the cable into the connector labeled 0–3.

Installation 2–39