ISUNIK2Ev2_GB_02_09.doc
UNIK2E
V2
ENGLISH
1. INTRODUCTION
The universal self-learning UNIK2E control unit has been designed for the automation of an access with 1 or 2
12VDC (24VDC)* motors with or without limit switches. Its innovative self-learning procedure makes for
quick and easy installation and its three trimmers permit fine adjustment of all main parameters: force
(or speed), pause time, obstacle detection sensitivity and closing delay between the two leaves of the
gate when two motors are used.
The following are available:
- simplified programming, thanks to which the unit automatically performs a learning operation to acquire running time and determine slow-down setting at ninety percent of opening and closing runs;
- A professional programming in which the installer can determine the instant in which the gate starts to
slow-down, the enabling of the pedestrian opening via radio, the safety device trigger mode.
2. MAIN FEATURES
•
Management and control of 12 VDC (or 24 VDC)* powered, 1 or 2 motor-driven automated accesses
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Motors closing offset adjustable from 0 to 15 seconds using trimmers
Double limit switch input open close
Motor force (speed) adjustable from 50-100%.using a trimmer.
Customisable partial opening (for pedestrian transit)
Softstart (slow motor start)
1 to 60” stand-by time adjustment via trimmer.
0.1 to 3.0” obstacle detection triggering time adjustment via trimmer.
Initial settings using dip-switches
Signalling LEDs (8)
Expansion for electric lock 12V 15W max (optional board ELU)
Expansion for courtesy light 230VAC 500W max (optional board LCU)
Built in battery charger with solar panel management
Box predisposed for optional 12V 1.2Ah battery for emergency manoeuvres (max connectable battery 7Ah)
Built-in 433MHz rolling-code receiver with 180 memorisable codes
Flash microprocessor re-programmable on-board via serial interface.
Programming and control of the control unit using a portable terminal GTSYSTEM (optional)
Built to European reference Directive Standards (R&TTE 99/05/CE)
DECLARATION OF CONFORMITY
Prastel S.p.A. declares that UNIK2E IS IN ACCORDANCE with the 99/05/EC (R&TTE) direcitve
The complete declaration of conformity is available in Prastel or to the internet address www.prastel.it
3. TECHNICAL SPECIFICATIONS
Transformer 230VAC
Control unit power:
Motor output:
Max current peak of motor:
12VAC (20VAC)*
12 VDC max 2 x 50Watt (24VDC max 2 x 60W)*
10 Amperes
Accessories power:
Environmental operating temperature :
Programming parameters:
BOX IP rating:
12 VDC - 250 mA protected by fuse (see info page 13)
-20°C / + 55°C memorised in EEPROM
IP54
(*)When using 24VDC motors, replace the supplied transformer with a 230/20VAC transformer with at least
20VA more power than the motor. The maximum power of the 24VDC motor driven by the control unit is 120W.
Only 12V batteries can be connected to the control unit, so when there is no mains power 24VDC motors will be powered at 12VDC.
3