advertisement
DIMENSIONS AND CAPACITIES DATA
HOT
CONNECTION
8"
C
A
B
FIGURE 1
Tank Capacity
US Gals.
66
80
119
Litres
250
303
450
Inches
60.13
60.50
61.38
A
TABLE 1 - ROUGH-IN DIMENSIONS
B cm
153
154
156
Inches
52.75
52.25
54.38
cm
134
133
138
Inches
22
24
28
C cm
56
61
71
Approx.
Shipping Weight
Lbs.
146
Kg.
66.22
174
268
78.93
121.56
TABLE 2 - RECOVERY CAPACITIES
Element
Wattage
(Upper/Lower)
NON-SIMULATANEOUS
3000/3000
INPUT
KW
3.0
4000/4000
4.0
4500/4500
4.5
5000/5000
5.0
SIMULATANEOUS OPERATION
3000/3000
6
4000/4000
8
4500/4500
9
5000/5000
10
F°
C°
GPH
LPH
GPH
LPH
GPH
LPH
GPH
LPH
GPH
LPH
GPH
LPH
GPH
LPH
GPH
LPH
36F°
U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED
40F° 54F° 60F° 72F°
20C° 22.2C° 30C° 33.3C° 40C°
80F°
44.4C°
90F°
50C°
100F°
55.5C°
108F°
60C°
34
128
45
170
51
192
56
213
68
256
90
341
101
384
113
426
30
115
41
153
46
173
51
192
61
230
81
307
91
345
101
384
34
128
38
142
23
85
30
114
45
170
60
227
68
256
75
284
20
77
27
102
30
115
34
128
41
153
54
205
61
230
68
256
25
96
28
107
17
64
23
85
34
128
45
170
51
192
56
213
23
86
25
96
15
58
20
77
30
115
41
153
46
173
51
192
20
77
23
85
14
51
18
68
27
102
36
136
41
153
45
170
18
69
20
77
12
46
16
61
24
92
32
123
36
138
41
153
17
64
19
71
11
43
15
57
34
128
38
142
23
85
30
114
120F° 126F°
66.6C° 70C°
15
58
17
64
10
38
14
51
20
77
27
102
30
115
34
128
14
55
16
61
10
37
13
49
29
110
32
122
19
73
26
97
Recovery capacities at 100° F rise equal: for non-simultaneous element operation = 4.1 gal. x KW of one element; for simultaneous element operation = 4.1 gal. x 2/3 KW of both elements. For other rises multiply element KW as previously explained by 410 and divide by temperature rise. Full load current for single phase = total watts : voltage.
5
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 2 SAFE INSTALLATION, USE, AND SERVICE
- 3 GENERAL SAFETY INFORMATION
- 3 Precautions
- 3 Hydrogen Gas (Flammable)
- 4 Introduction
- 4 Preparing for the Installation
- 5 dimensions and capacities data
- 6 APPROVALS
- 6 model and rating
- 7 FEATURES AND COMPONENTS
- 8 LOCATING THE NEW WATER HEATER
- 8 Facts to Consider About the Location
- 8 Clearances
- 9 iNSTALLATION
- 9 Required Ability
- 9 General
- 9 Contaminated Water
- 9 Circulating Pump
- 9 Insulation Blankets
- 9 Temperature-Pressure Relief Valve
- 10 Closed Water Systems
- 10 Thermal Expansion
- 11 electrical
- 11 General
- 11 Branch Circuit
- 11 Calculating Amperage/Overcurrent Protection
- 12 WIRING DIAGRAMS
- 13 OPERATION
- 13 General
- 13 Filling the Water Heater
- 13 Initial Start Up
- 13 Draining the Water Heater
- 14 TEMPERATURE REGULATION
- 14 Temperature Adjustment
- 15 MAINTENANCE
- 15 General
- 15 Anode Rod Inspection
- 16 TROUBLESHOOTING CHECKLIST
- 16 Checklist
- 17 Leakage Checkpoints
- 18 WARRANTY