8.1

Technical Description

The Invacare Oxygen Conserving Cylinder is an oxygen storage product that can deliver up to 5 L/min of pulse flow oxygen to the patient via a nasal cannula. The cylinder assembly is designed to store compressed oxygen up to 2,100 psig (14479 kPa). The conserver reduces the pressure at the cannula connection to 50 psig (345 kPa) and contains a rotary flow dial that is used to adjust the oxygen flow rate to the prescribed setting. The cylinder assembly is filled with USP 93±3% oxygen using its proprietary fill port that allows filling only through the use of an Invacare HomeFill

System. The duration of oxygen flow between fills is dependent on the size of the cylinder and the flow setting.

8.2

Specifications

Settings

Conserver S/N Range:

Pulse Settings:

Flow Settings:

Savings Ratio:

1–69,999

1, 2, 3, 4, & 5

2 L/min Continuous

Up to 4.3:1

75,000+

1, 2, 3, 4, & 5

2 L/min Continuous

Up to 5.7:1

Pressures

Conserver S/N Range:

Inlet Pressure Range:

Internal Regulated Pressure:

Max Fill Pressure:

Burst Pressure:

1–69,999

300–2100 psig

50 psig

2100 psig (14479 kPa)

3025–3360 psig at 72°F (20857–23166 kPa at 22.2°C)

75,000+

300–2100 psig

50 psig

2100 psig (14479 kPa)

3025–3360 psig at 72°F (20857–23166 kPa at 22.2°C)

24 1112648-H-00

Technical Data

Environmental Operating Temperature Range

Conserver S/N Range:

Operating Conditions Temperature:

1–69,999

32°F to 105°F (0°C to 40.6°C)

Altitude:

Storage Conditions Temperature:

Maximum Humidity:

0 to 5,280 ft (0 to 1600 m)

-40°F to 140°F (–40°C to 60°C)

95% RH

Assembly Dimensions

Conserver S/N

Range:

Model: HF2PCL4

Weight:

Overall Length:

Diameter:

N/A

N/A

N/A

1–69,999

HF2PCL6

4.3 lb (1.95 kg)

11.1 in (28 cm)

4.4 in (11.1 cm)

HF2PC9

5.3 lb (2.4 kg)

14.2 in (36 cm)

4.4 in (11.1 cm)

75,000+

35°F to 105°F (1.7°C to 40.6°C)

0 to 10,000 ft (0 to 3071 m)

-40°F to 140°F (–40°C to 60°C)

95% RH

75,000+

HF2PCL4

3.6 lbs (1.63 kg)

8.9 in (22.2 cm)

4.4 in (11.1 cm)

HF2PCL6

4.1 lb (1.86 kg)

10.9 in (27.7 cm)

4.4 in (11.1 cm)

HF2PC9

5.1 lb (2.31 kg)

14 in (35.5 cm)

4.4 in (11.1 cm)

Cylinders

Cylinder Size:

Volume (H

2

O):

Oxygen Capacity:

Fill Times

ML4

0.67 L (0.024 ft 3 )

113 L (4 ft

3

)

ML6

1.0 L (0.035 ft 3 )

170 L (6 ft

3

)

M9

1.7 L (0.061 ft 3 )

255 L (9 ft

3

)

HF2PCL4

Normal

60 min*

Maximum

1 hr 25 min*

1112648-H-00 25

Invacare® ML4, ML6 and M9 Cylinder with Conserver

HF2PCL6

HF2PC9

*With Concentrator flow rates to patient:

Concentrator Model

Platinum 5 and Perfecto

Platinum 10

2

1 hr 25 min*

2 hr 20 min*

Concentrator Flow Rate

Up to 3 L/min

Up to 5 L/min

All filling times are approximate and may vary on environmental conditions.

1 hr 50 min*

2 hr 45 min*

Accessories

Model

Single Lumen Cannula

Carry Bag

HF2PCL4 HF2PCL6

4’ (1.21 m) recommended. 7’ (2.1 m) tubing length maximum

HF2PC9

HF2PCL4 Carry Bag HF2PCL6 Carry Bag HF2PC9 Carry Bag

Regulatory Compliance

CGA G-4.1 (Cleaning Equipment For Oxygen Service)

DOT & TC (3AL & 3ALM)

26 1112648-H-00

Notes

Invacare Corporation

USA

One Invacare Way

Elyria, Ohio USA

44036–2125

440–329–6000

800–333–6900

Technical Services

440–329–6593

800–832–4707 www.invacare.com

Canada

570 Matheson Blvd E Unit 8

Mississauga, Ontario

L4Z 4G4 Canada

800–668–5324 www.invacare.ca

Manufacturer

Invacare Corp.

2101 E. Lake Mary Blvd.

Sanford, FL 32773

Tel: 407–321–5630

1112648-H-00 2016-02-10

*1112648H-00*

Making Life’s Experiences Possible™

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals