Chapter 4. Host Communications Interface (HCI) Error Messages. Compuware MVS, Messages and Codes
广告
广告
4-1
Chapter 4.
Host Communications Interface (HCI) Error Messages
Chap 4 4
This chapter explains the return codes and messages issued by the Host Communication
Interface (HCI).
HCI User Abend Codes
For U0100 abends regarding HCISERVR see “HCISERVR Abend Codes” on page 4-5.
For user abends regarding HCIAPING see “HCIAPING Abend Codes” on page 4-5.
Table 4-1.
User ABEND Codes: Meaning of HCI user abends
USER
ABEND MODULE
REASON
CODE DESCRIPTION
U0044 HCIRESUM N/A Entry to HCIRESUM was made holding an MVS Local Lock but not for the region requesting service.
Note: Initialization Routines:
U0100 HCIMMAIN 001
002
004
005
Unable to load HCIMINIT the initialization module.
Insufficient storage for Journal Communication Area in SP=0,
LOC=ANY.
Insufficient storage for save areas in SP=250, LOC=ANY.
100
Insufficient storage for Global Communication Area in SP=241,
LOC=ANY.
Non-zero return code from SHOWCB. High order halfword contains R15 value.
101
102
103
Insufficient storage for VTAM control blocks in SP=0,
LOC=BELOW or LOC=ANY. High order halfword contains R15 value.
Non-zero return code from VTAM GENCB macro. High order halfword contains R15 value.
Non-zero return code from MVS ATTACH attempting to attach a processing sub task. High order halfword contains R15 value.
104
105
106
107
108
109
110
Non-zero return code from MVS CPOOL BUILD attempting to build the DCB pool.
Non-zero return code from MVS CPOOL BUILD attempting to build the RPL pool.
Non-zero return code from MVS CPOOL BUILD attempting to build the CCB pool.
Non-zero return code from MVS CPOOL BUILD attempting to build the LUB pool.
Non-zero return code from MVS CPOOL BUILD attempting to build the RCB pool.
Non-zero return code from MVS CPOOL BUILD attempting to build the UIB pool.
Insufficient storage for WRE queue, in SP=241, LOC=ANY. High order halfword contains R15 value from GETMAIN.
4-2
Enterprise Common Components Messages and Codes
Table 4-1.
User ABEND Codes: Meaning of HCI user abends
USER
ABEND MODULE
REASON
CODE DESCRIPTION
U0100
(continued)
HCIMMAIN 111
113
Insufficient storage for ORE queue, in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN.
Insufficient storage for CCB hash table in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN.
114
115
Insufficient storage for SIT hash table in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN.
Non-zero return code from MVS LOAD macro attempting to load a module destined for SP=245. High order halfword contains R15 value from GETMAIN.
116
118
119
120
121
122
123
124
125
Non-zero return code from MVS LOAD macro attempting to load a module destined for SP=0. High order halfword contains
R15 value from LOAD.
An HCI specifying the same four character SUBSYSTEM_ID is currently active on this system.
Non-zero return code from MVS ESTAE macro. High order halfword contains R15 value from ESTAE.
Non-zero return code from MVS STIMERM macro. High order halfword contains R15 value from ESTAE.
In response to the message indicating that a subsystem of the same name was still active, the operator replied “A” to ABEND the new HCI.
Insufficient storage for CSA modules in SP=245, LOC=BELOW.
High order halfword contains R15 value from GETMAIN.
Insufficient storage for CSA modules in SP=245, LOC=ANY. High order halfword contains R15 value from GETMAIN.
Insufficient storage for CSA modules in SP=241, LOC=BELOW.
High order halfword contains R15 value from GETMAIN.
A subsystem ID was chosen for the HCI which matches an SSCT entry that was not for an HCI. You must specify a unique subsystem.
125
127
128
200
201
202
203
204
205
206
Insufficient storage for ACE queue, in SP=0, LOC=ANY. High order halfword contains R15 value from GETMAIN.
Non-zero return code from MVS CPOOL BUILD attempting to build the TEA pool.
Non-zero return code from MVS CPOOL BUILD attempting to build the TSB pool.
Non-zero return code from MVS CPOOL BUILD attempting to build the AMB pool.
Insufficient storage for JCB areas in SP=0, LOC=BELOW.
Insufficient storage for SIT areas in SP=0, LOC=BELOW. Too many SIT entries specified.
Insufficient storage for TPT areas in SP=0, LOC=BELOW. Too many TPT areas specified.
Non-zero return code from PD FDB$SRVM macro when trying to load the configuration table.
Non-zero return code from MVS CPOOL BUILD attempting to build the PCB pool.
In the attempt to process PCB entries, no matching TPT was found for a PCB entry.
Host Communications Interface (HCI) Error Messages
4-3
Table 4-1.
User ABEND Codes: Meaning of HCI user abends
USER
ABEND MODULE
REASON
CODE DESCRIPTION
U0100
(continued)
HCIMMAIN 207
208
In the attempt to process PCB entries, no matching AMB was found for a PCB entry.
In the attempt to process SIT entries, no matching AMB was found for a SIT entry.
209
210
211
212
213
214
2102
In the attempt to process SIT entries, no matching PCB was found for a SIT entry.
Bad open for FDBDRPL data set.
The HCICNFIG module could not be found.
Insufficient storage for the HCICNFIG module.
The Module HCICNFIG could not be loaded.
2108
An ALIAS TPT entry could not be found.
Unable to load the operator communications initialization module.
Unable to load the modules required by operator communications.
Storage for work area not available. Increase REGION parameter on EXEC statement.
U0100
(continued)
DYNACTLG
DYNAIDCM
DYNAMAIN
DYNASV99
N/A
Note: Termination Routines
U0101 HCIMMAIN 2108
U0200 N/A
Unable to load the modules required by operator communications.
Unsuccessful initialization
U0201
HCIOMAIN
HCIRMAIN
HCIJMAIN N/A
U0202
U0203
U0204
U0205
U0210
HCIPSCHG
HCIPSCHG
HCIPSCHG
HCIPSCHG
N/A
N/A
N/A
N/A
HCIMCLEAN N/A
Non-zero return code from FREEMAIN attempting to free a journal buffer.
Send completed with non-zero return code.
Deallocate completed with non-zero return code.
Set deallocate type completed with non-zero return code.
Deallocate completed with non-zero return code.
The ACE queue has been exhausted while attempting to delay the delete of an ACEE. Increase the number of CCBs in the configuration assembly.
U0300
U0301
U0302
U0303
HCIAMAIN 002
HCIIMAIN N/A
HCIRMAIN 005
HCITMAIN N/A any module N/A any module
HCITTERM
HCIUTERM
N/A
N/A
Unsuccessful initialization
Unsuccessful initialization
Unsuccessful initialization
Unsuccessful initialization
A subroutine call did not have sufficient storage to save registers in the module working storage area. Refer this problem to
Compuware.
A subroutine exit could not retrieve its entry registers in the module working storage area. Refer this problem to
Compuware.
A termination request has been made and no AMB, TSB or PCB is available. Refer this problem to Compuware.
4-4
Enterprise Common Components Messages and Codes
Table 4-1.
User ABEND Codes: Meaning of HCI user abends
USER
ABEND MODULE
REASON
CODE DESCRIPTION
U0800 All Work Request Elements have been exhausted. Increase the number of WREs in the configuration assembly.
HCIACNOC
HCICACCP
HCICNEND
HCICOPEN
HCIENFSX
HCIICNOI
HCIMSAF
HCIMUNRU
HCIOESTI
HCIPCRTN
HCIPOSTX
HCIRCTLI
HCIRRCVC
HCISESTI
HCITMAIN
HCIUCTLI
HCIURTOS
HCIVATNX
HCIVTPNX
N/A
U0801 Insufficient storage for a register save area. Increase the
REGION= parm on the HCI EXEC statement.
U0802
HCIAACSC
HCIAALCC
HCIACNFC
HCIACNOC
HCIADELC
HCIAPTRC
HCIARCVC
HCIASNDC
HCIMGDSA
HCIMSTIM
HCIRCLDC
HCIROPDC
HCIRRCVC
HCIVATNX
HCIVLGNX
HCIVLSTX
HCIVNSXX
HCIVSCIX
HCICTPNX
N/A any module N/A
U0905
U3000
U3001
U3002
HCIPCRTN
HCIOPCOM
HCIOPCOM
HCIOPCOM
N/A
N/A
N/A
N/A
Insufficient private storage to obtain module working storage area. Increase the REGION= parm on the HCI EXEC statement.
A corruption of the WRE chain has been detected. Refer this problem to Compuware.
Non-zero return code from MVS ATTACH of operator task.
Insufficient number of OREs.
Operator subtask initialize not successful.
U3003
U4094
U4095
HCIPCRTN
HCIABEND
HCIABEND
N/A
N/A
N/A
Operator subtask has abended three times in a row. The entire
HCI is terminated.
An invalid UIB address was found in word 1 of the TCB save area.
The operator issued a STOP command for a processing subtask, requesting ABEND with no dump.
The operator issued a STOP command for a processing subtask, requesting ABEND, DUMP.
Host Communications Interface (HCI) Error Messages
4-5
HCIAPING Abend Codes
The following abend codes apply to the HCIAPING program only.
Table 4-2.
HCIAPING ABEND Codes: Meaning of HCIAPING abends
USER
ABEND
U0004
REASON
CODE
N/A Storage was not available for the input/output buffer. End the HCI and increase the value specified for REGION=.
DESCRIPTION
U0008 N/A Invalid PARM data passed to HCIAPING. Refer this problem to Compuware.
U0012
U0016
U0020
U0024
CPI-C
CPI-C
CPI-C
CPI-C
Non-zero return code from CWRNU. The reason code is the CPI-C return code.
Non-zero return code from CWSPM. The reason code is the CPI-C return code.
Non-zero return code from CWACCP The reason code is the CPI-C return code.
Non-zero return code from CWEPLN The reason code is the CPI-C return code.
U0028
U0032
U0036
U0100
U0104
U0108
CPI-C
CPI-C
CPI-C
CPI-C
CPI-C
CPI-C
Non-zero return code from CMSPTR The reason code is the CPI-C return code.
Non-zero return code from CMSST The reason code is the CPI-C return code.
Non-zero return code from CMSRT. The reason code is the CPI-C return code.
Non-zero return code from CMRCV. The reason code is the CPI-C return code.
Non-zero return code from CMCFMD The reason code is the CPI-C return code.
Non-zero return code from CMSEND The reason code is the CPI-C return code.
HCISERVR Abend Codes
The following reason codes for U0100 abends can be issued by HCISERVR:
Table 4-3.
HCISERVR Reason Codes for U0100 abends: Abend reason codes from the started task control program
REASON CODE DESCRIPTION
00000008 Invalid PARM on the HCISERVR EXEC statement
0000000C
00000010
00000014
00000018
0000001C
SUBSYSTEM_ID named in PARM is not active
The HCI user represented by the started task identifier is not pending attach within the
HCI.
Insufficient storage to execute HCISERVR
Invalid PARM on the HCISERVR EXEC statement
00xxyyzz
SUBSYSTEM_ID named in PARM is active but not the same version as the HCISERVR.
Example: trying to use a 1.6.0 HCISERVR against an 2.0.0 HCI. The versions 1 and 2 do not match.
RACROUTE error codes: xx = SAF return code yy = Security system return code zz = Security system reason code
4-6
Enterprise Common Components Messages and Codes
HCIYPREP Abend Codes
The following abend and reason codes can be issued by HCIYPREP:
Table 4-4.
HCIYPREP ABEND and Reason Codes: Abend and reason codes from the remote Sysplex initialization
USER
ABEND
REASON
CODE DESCRIPTION
U0800
U0810
U0820
8
20
28
Parameter list incorrect length or NOTIFY incorrectly specified.
Insufficient storage for Sysplex Communication Area in SP=241, LOC=ANY.
32
Non-zero return code from MVS LOAD macro attempting to load a module into private storage.
Non-zero return code from MVS LOAD macro attempting to load a module into private storage.
36
U0830 40
Insufficient storage to hold module destined for SP=241, LOC=BELOW
(common storage).
The subsystem id specified in the execution parameters was found to be already active on this system.
Module HCIYSSYS (subsystem exit) was not found to be valid.
U0831
44
48
52
*
Module HCIRACRP was not found to be valid.
The XCA control block was found not to be valid.
U0832
U0840
U0860
U0870
U0880
*
60
*
*
*
Insufficient storage to initialize the SSCT and SSVT in SP=241 LOC=BELOW for subsystem creation. The abend reason code is the STORAGE return code.
Insufficient storage for CSA modules in SP=245, LOC=ANY. The abend reason code is the STORAGE return code.
Insufficient storage for SRB and PCA creation in SP=245, LOC=ANY.
The group name could not be located in the sysplex. The group name is HCI sysplex id prefixed with “XCIO”. The abend reason code contains a halfword
IXCQUREY return code (high order) and reason code (low order).
Insufficient private storage to acquire the sysplex group information. The abend reason code is the STORAGE return code.
Error during query of sysplex group information. The abend reason code contains a halfword IXCQUREY return code (high order) and reason code (low order).
U0890 * Insufficient storage for temporary SRB and GXP, SP=245 LOC=ANY. The abend reason code is the STORAGE return code.
U0900 n/a Temporary SRB and GXP no longer valid during notify process.
NOTE: * - see description; n/a - not applicable.
HCIPSCHG Abend Codes
The following abend and reason codes can be issued by HCIPSCHG:
Table 4-5.
HCIPSCHG Reason Codes: Abend reason codes from the password change internal TP
USER
ABEND
REASON
CODE DESCRIPTION
U0100 N/A Unable to obtain storage for a RACROUTE parameter area.
U0101
U0102
N/A
N/A
Invalid PARM passed to HCIPSCHG on EXEC statement.
Register New User completed with non-zero return code.
Host Communications Interface (HCI) Error Messages
4-7
U0109
U0110
U0111
U0200
U0201
U0202
U0203
U0204
U0205
Table 4-5.
HCIPSCHG Reason Codes: Abend reason codes from the password change internal TP
USER
ABEND
REASON
CODE DESCRIPTION
U0103
U0104
N/A
N/A
SUBSYSTEM_ID passed in PARM is not defined.
SUBSYSTEM_ID passed in PARM is not active.
U0105
U0106
U0107
U0108
N/A
N/A
N/A
N/A
SUBSYSTEM_ID passed in PARM defines a subsystem that is not an HCI,
Set Processing Mode completed with non-zero return code.
Accept Conversation completed with non-zero return code.
Extract Partner LU_NAME completed with non-zero return code.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Set Deallocate Type completed with non-zero return code.
Set Send Type completed with non-zero return code.
Set Receive Type completed with non-zero return code.
Receive completed with non-zero return code.
Confirmed completed with non-zero return code.
Send completed with non-zero return code.
Deallocate completed with non-zero return code.
Set Deallocate Type completed with non-zero return code.
Deallocate completed with non-zero return code.
R15 Return Codes
R15 return code values are reserved, primarily, for severe problems detected by the CPI-C interface (link-edited) module. Essentially, a non-zero value in R15 upon return from
ANY CPI-C (standard or extension) indicates that the operation did not function as desired, and, what's more, indicates that the problem is severe enough that the normal
CM_RETURN_CODE field could not be used to pass back the error indication.
Additionally, no Secondary_Codes are available following the receipt of a non-zero R15 value.
The following lists the values R15 can contain upon return from a CPI-C call:
Table 4-6.
R15 Return Codes: Explanation of values returned in R15
R15 Value
(In Decimal) Meaning
00 Normal Completion. Inspect the field CM_RETURN_CODE for further error indications.
16
20
The PC routine within the HCI address space was unable to obtain a register save area. The queue of available save areas is exhausted. You must refresh the HCI after specifying a larger number in the configuration data set for the number of available save areas.
While executing on your behalf, the PC routine within the HCI address space has experienced an abend. The abend has been trapped, and a dump has been taken to a
SYS1.DUMPxx data set. The most likely cause of an abend is that you specified a parameter value that was an address which was outside the limits of your available storage, or that lay in storage containing a protect key other than the one under which you are executing.
24
28
You have entered the sub-module at its program name entry point, rather than one of the
CMxxx or CWxxx entry points. Your program is in error and must be changed. You may not call this module at its program name entry point.
The HCI address space is no longer active. It has been active, but has ended. You must not attempt any more calls to the HCI. When the HCI is restarted, you must re-register using the CWRNU call.
4-8
Enterprise Common Components Messages and Codes
Table 4-6.
R15 Return Codes: Explanation of values returned in R15
R15 Value
(In Decimal) Meaning
32
36
40
Main storage, below the 16m line, was not available to hold a copy of your ECB wait list for the execution of a CWWMUE call. You must end your job, and re-execute specifying a larger value for the REGION= parameter on the EXEC statement. This is storage within your region, not within the HCI region.
Main storage, below the 16m line, was not available for a register save area for the execution of a CWRNU or CWWMUE call. You must end your job, and re-execute specifying a larger value for the REGION= parameter on the EXEC statement. This is storage within your region, not within the HCI region.
More than nineteen (19) parameters have been passed to a CMxxx or CWxxx call, or you forgot to set the high order bit of the last parameter in the list. A variable list with a maximum of nineteen values is required for any CPI-C call.
44
48
52
56
60
A parameter has been passed to a CMxxx or a CWxxx call which is zero. Since each parameter in the list pointed to by R1 must be the address of the corresponding storage area, a value of zero is never allowed.
Each CPI-C call has a fixed number of parameters. You have made a CMxxx or a CWxxx call with the wrong number of parameters in the list. Even though the parameter list must be of variable length (the high-order bit of the last address set to B'1'), each CPI-C call required a specific number of entries in the list.
Your installation's security personnel have activated the HCI's TP_NAME security processing. You have issued a CWRNU specifying a TP_NAME to which the USERID under which you are running does not have (at least) READ access. See your security administrator for details.
The Sub-System which you named in your CWRNU or CWCDE call is not active. It may be that it just needs to be started or it may be that you have specified an incorrect name. Also, check that the version of the currently active HCI is the same as the what the TP utilizes.
Main storage, below the 16m line is not available to build the RACROUTE list. you must end your job, and re-execute specifying a larger value for the REGION= parameter on the
EXEC statement. This is storage within your region, not within the HCI region.
64
68
72
76
80
84
The attempt to identify alternate entry points for subsequent CPI-C calls has failed. You must refer this problem to your software support staff.
You have called the HCI from a task other than the one which was originally used to register (CWRNU call). You must restrict HCI calls to the same task under which the
CWRNU call was made.
You have issued a CWRNU call, passing a TP_NAME_length field that contains a value of
0 or a value greater than 64.
One of the parameters you have passed is invalid. Either the address itself isn't a valid address, or it points to an area of storage which is in a protect key which disallows either reference (for parameters passed to the HCI) or modification (for parameters passed from the HCI to the TP).
The HCI address space is no longer active. It has been active, but has ended. You must not attempt any more calls to the HCI except for CWWMUE which will continue to function by waiting on only the ECBs in the users wait list. This return code will be returned each time CWWMUE is called.
The HCI address space has been found active but it is not the same version level as the
CWRNU or CWELLS request. Verify that the TP release utilizes the same version of the currently active HCI. This can be encountered when a new release of a product has been installed.
Host Communications Interface (HCI) Error Messages
4-9
LU 2 Return Codes
The following codes are sent to the LU 2 HLLAPI processor in the Attach Reply message and in the Detach Request message to indicate success or failure of the attach, or to indicate reason for the detach.
08
08
08
08
08
08
08
08
08
08
08
08
08
08
Table 4-7.
LU 2 Return Codes: Explanation of the returned codes
PRIMARY CODE SECONDARY CODE MEANING
00
08
00 Successful Attach
Attach Failed. Reasons follow:
08
08
08
08
08
08
01
02
03
04
05
06
Insufficient main storage available
No Work Request Elements available
TP_NAME length in Attach Request invalid
USERID length in Attach Request invalid
PASSWORD length in Attach Request invalid
Insufficient main storage available
08
08
08
08
08
08
08
08
07
08
09
10
11
12
13
14
No Region Control Blocks available
TP issued Deallocate (ABEND)
Deallocated Abend (TIMER)
Deallocated Abend (SERVICE)
Deallocated Abend (USER)
TP_NAME length in Attach Request invalid
USERID length in Attach Request invalid
PASSWORD length in Attach Request invalid
15
16
17
18
19
20
21
22
23
24
25
26
27
28
No Work Request Elements available
Generic User Interface Block not found
No Conversation Control Blocks available
No Destination Control Blocks available
TP Profile entry not found; TP not registered
No User Interface Blocks available
Unspecific return code from RACROUTE processor
USERID not defined to Security System
Incorrect PASSWORD for USERID
PASSWORD has expired
New PASSWORD invalid
USERID not defined in GROUP
USERID has been revoked
Access to GROUP has been revoked
4-10
Enterprise Common Components Messages and Codes
Error Messages
HCIHC0000S HCI SUBSYSTEM @@ ALREADY ACTIVE ON SYSTEM @@
Explanation: During initialization, the HCI has detected that a subsystem with the same
Subsystem ID, which the current HCI is attempting to use, is still active on the MVS system identified in the message.
Severity: HCI is terminated.
User Response: Specify a different HCI subsystem ID or wait for the same one to finish.
HCIHC0001S @@ SUBSYSTEM @@ IS STILL ACTIVE ON SYSTEM @@
Explanation: During initialization, the HCI has detected that a subsystem with the same
Subsystem ID which the current HCI is attempting to use, is still active on the MVS system identified in the message. HCI Subsystems do not automatically terminate until all application programs which were ever active have ended. Ended means that the MVS TCB under which the application was running has been detached, or that the entire address space in which the application was running has terminated.
Severity: Processing continues with message HC0006.
User Response: Wait for message HC0006, and reply to it appropriately.
HCIHC0002I @@ JOBNAME=@@, STEPNAME=@@
Explanation: This message is displayed by the HCI when the operator replies “D” to message
HC0006, requesting further information regarding the application programs that are keeping the subsystem from ending. The Job name and the Step name of each application still active are displayed in this message.
Severity: Processing continues.
User Response: Wait for message HC0006, and reply to it appropriately.
HCIHC0003I @@ TPNAME=@@
Explanation: This message is displayed by the HCI when the operator replies “D” to message
HC0006, requesting further information regarding the application programs that are keeping the subsystem from ending. The TP names for each application within the previously displayed job step are displayed in this message.
Severity: Processing continues.
User Response: Wait for message HC0006, and reply to it appropriately.
HCIHC0004I @@ SUBSYSTEM @@ NO LONGER ACTIVE. HCI STARTUP WILL CONTINUE
Explanation: This message is displayed by the HCI when the operator replies “D” to message
HC0006, and the HCI determines that the problem (of an old copy of the Subsystem) no longer exists. That is, either the application, itself, ended, or the action that the operator took to cancel the application was successful. In either case, initialization of the new HCI continues.
Severity: Processing continues.
User Response: None.
HCIHC0005I @@ OLD SUBSYSTEM @@ ABORTED. HCI STARTUP WILL CONTINUE
Explanation: This message is displayed by the HCI when the operator replies “O” to message
HC0006, and the HCI has successfully terminated the old copy of the Subsystem, and when all storage allocated to that Subsystem has been freed. Initialization of the new HCI continues.
Severity: Processing continues.
User Response: None.
HCIHC0006C @@ REPLY “U” TO CONTINUE, “A” TO ABORT, OR “D” TO SHOW STATUS
Explanation: This message is displayed by the HCI following message HC0001, or HC0003.
This message request that the operator decide whether to let the old copy of the Subsystem
Host Communications Interface (HCI) Error Messages
4-11
continue running (“A”), or let the new copy of the Subsystem continue running (“U”), or simply to display the status of the old HCI (“D”).
Severity: HCI initialization is suspended until the operator replies. If the operator replies
“U”, the old copy of the Subsystem will be terminated, and all storage associated with it will be freed. The new HCI will continue initialization. If the operator replies “A”, the old copy of the
Subsystem will be allowed to continue, and initialization of the new HCI will terminate. If the operator replies “D”, the status of the old HCI will be displayed via messages HC0002 and
HC0003.
User Response: Reply “U”, “A” or “D”.
HCIHC0007E @@ UNABLE TO ATTACH JOURNAL TASK. R15=@@
Explanation: The MVS ATTACH macro was issued to activate the Journal function sub-task.
At the completion of the macro, Register 15 was not zero. The contents of R15 are displayed in the message. If R15=08, there is not sufficient storage to process the ATTACH request. Any other return code in R15 indicates an unexpected logic error.
Severity: Processing continues.
User Response: None.
HCIHC0008E @@ JOURNAL TASK INITIALIZATION ERROR @@
Explanation: Initialization has failed for the Journal function subtask. This may have resulted from insufficient storage, error when loading a module, or failure of another macro or function used in VSAM file initialization. The return code displayed is explained in the HCI
Logic description.
Severity: Processing continues.
User Response: None.
HCIHC0009I @@ JOURNAL @@ BEING OPENED
Explanation: The Journal file identified by the DDNAME listed in this message is being opened by the HCI Subsystem.
Severity: Processing continues.
User Response: None.
HCIHC0010I @@ JOURNAL @@ OPENED
Explanation: The Journal file identified by DDNAME in the message has been successfully opened.
Severity: Processing continues.
User Response: None.
HCIHC0011I @@ JOURNAL @@ BEING CLOSED
Explanation: The Journal file identified by the DDNAME listed in this message is being closed by the HCI Subsystem.
Severity: Processing continues.
User Response: None.
HCIHC0012I @@ JOURNAL @@ CLOSED
Explanation: The Journal file identified by DDNAME in the message has been successfully closed.
Severity: Processing continues.
User Response: None.
HCIHC0013I @@ JOURNAL @@ BEING ALLOCATED
Explanation: The Journal file identified by the DDNAME listed in this message is being allocated by the HCI Subsystem.
Severity: Processing continues.
4-12
Enterprise Common Components Messages and Codes
User Response: None.
HCIHC0014I @@ JOURNAL @@ ALLOCATED ON VOLSER @@
Explanation: The Journal file identified by DDNAME in the message has been successfully allocated on the volume identified in the message.
Severity: Processing continues.
User Response: None.
HCIHC0015I @@ JOURNAL @@ BEING DEALLOCATED
Explanation: The Journal file identified by the DDNAME listed in this message is being deallocated by the HCI Subsystem.
Severity: Processing continues.
User Response: None.
HCIHC0016I @@ JOURNAL @@ DEALLOCATED
Explanation: The Journal file identified by DDNAME in the message has been successfully deallocated.
Severity: Processing continues.
User Response: None.
HCIHC0017E @@ JOURNAL @@ ALLOCATION ERROR
Explanation: This message indicates that an error has occurred in the attempt to allocate a
Journal file. DDNAME in the message identifies the file in error. See also message HC0024 for further error information.
Severity: Processing continues.
User Response: None.
HCIHC0018I @@ JOB = @@, TP_NAME = @@ HAS ENDED
Explanation: This user has been force terminated from the HCI, via subsystem notify. The TP named in the message has been terminated. The TP was running as part of the job named in the message, and it was forced by the subsystem named in the message.
Severity: Processing continues.
User Response: None.
HCIHC0019E @@ JOURNAL @@ VSAM OPEN ACB ERROR
Explanation: This message indicates that an error has occurred in the attempt to open the
ACB for a Journal file. DDNAME in the message identifies the file in error. See also message
HC0025 for further error return code information.
Severity: Processing continues.
User Response: None.
HCIHC0020E @@ JOURNAL @@ DEALLOCATION ERROR
Explanation: This message indicates that an error has occurred in the attempt to release the allocation for a Journal file. DDNAME in the message identifies the file in error. See also message HC0024 for further error return code information.
Severity: Processing continues.
User Response: None.
HCIHC0021I @@ JOURNAL @@ HAS BEEN FILLED
Explanation: A VSAM PUT failed because there is no space left in the current Journal file. An attempt will be made to cycle to the next Journal file in use.
Severity: Processing continues.
User Response: None.
Host Communications Interface (HCI) Error Messages
4-13
HCIHC0022I @@ NO JOURNALS ARE AVAILABLE FOR USE
Explanation: As part of processing to make a Journal file ready for use, all Journal files were checked. None were found available. This could be the result of having no journals originally configured. If this is the case, then this message does not constitute an error. The HCI is simply notifying you that you have not configured any journals, and, therefore, there are none available for use. Or, the condition which caused this message could be the result of a failure to open a Journal, or because the available space in the Journal files was used up. The Journal facility will be unavailable until the state of the Journal files is altered.
Severity: Processing continues.
User Response: None.
HCIHC0023E @@ JOURNAL @@ VSAM CLOSE ACB ERROR
Explanation: This message indicates that an error has occurred in the attempt to close the
ACB for a Journal file. DDNAME in the message identifies the file in error. See also message
HC0025 for further error return code information.
Severity: Processing continues.
User Response: None.
Explanation: This message shows the error return code from the failing attempt to allocate a
Journal file. DDNAME in the message identifies the file in error. See also message HC0017 for further information.
Severity: Processing continues.
User Response: None.
HCIHC0025I @@ R15=@@. ACBERROR=@@
Explanation: This message shows the error return code from the failing attempt to open an
ACB for a Journal file. DDNAME in the message identifies the file in error. See also message
HC0018 for further information.
Severity: Processing continues.
User Response: None.
HCIHC0026E @@ JOURNAL @@ VSAM WRITE ERROR
Explanation: This message indicates that an error has occurred in the attempt to write a
Journal file record. DDNAME in the message identifies the file in error. See also message
HC0027 for further error return code information.
Severity: Processing continues.
User Response: None.
Explanation: This message shows the error return code from the failing attempt to write a
Journal file record. DDNAME in the message identifies the file in error. See also message
HC0026 for further information.
Severity: Processing continues.
User Response: None.
HCIHC0029E @@ APPLID @@ VTAM ACB OPEN ERROR
Explanation: This message indicates that an error has occurred in the attempt to open the
ACB for a VTAM application name. APPLNAME in the message identifies the name of the application. See also message HC0030 for further error return code information.
Severity: Processing continues.
User Response: None.
4-14
Enterprise Common Components Messages and Codes
HCIHC0030I @@ R15=@@. ACBERFLG=@@
Explanation: This message shows the error return code from the failing attempt to open an
ACB for a VTAM application name. APPLNAME in the message identifies the application name in error. See also message HC0029 for further information.
Severity: Processing continues.
User Response: None.
HCIHC0031I @@ APPLID @@ VTAM ACB OPEN
Explanation: The VTAM application name identified by APPLNAME in the message has been successfully opened.
Severity: Processing continues.
User Response: None.
HCIHC0032E @@ APPLID @@ VTAM ACB CLOSE ERROR
Explanation: This message indicates that an error has occurred in the attempt to close the
ACB for a VTAM application name. APPLNAME in the message identifies the name of the application. See also message HC0030 for further error return code information.
Severity: Processing continues.
User Response: None.
HCIHC0033I @@ APPLID @@ VTAM ACB CLOSED
Explanation: The VTAM application name identified by APPLNAME in the message has been successfully closed.
Severity: Processing continues.
User Response: None.
HCIHC0034E @@ SETLOGON (START) COMPLETION ERROR. @@,@@
Explanation: This message indicates that an error has occurred in the attempt to issue the
VTAM request SETLOGON START. The message includes the error return codes from the RPL and the sense code.
Severity: Processing continues.
User Response: None.
HCIHC0035E @@ SUBTASK @@ UNABLE TO ESTABLISH ESTAE. R15=@@
Explanation: This message indicates that an error has occurred in the attempt to issue the
MVS ESTAE macro for a VTAM application processing subtask. APPLNAME in the message identifies the name of the application. The return code in Register 15 from the ESTAE macro is also listed. The return code can be one of the following: X'0C', X'10',X '14', X'18', X'1C', X'20',
X'24' or X'28'. Refer to the MVS Application Development Macro Reference for further information on these return codes.
Severity: Processing continues.
User Response: None.
HCIHC0036I @@ SUBTASK @@ IS INITIALIZED
Explanation: This message indicates that the MVS ESTAE macro was successfully issued.
Establishing the ESTAE exit is the last step in initialization for a VTAM application processing subtask. APPLNAME in the message identifies the name of the application.
Severity: Processing continues.
User Response: None.
HCIHC0037E @@ INVALID COMMAND. RETRY
Explanation: Either the command entered was invalid, or a valid command with invalid parameters was entered. The failing command is listed in the message. Re-enter a valid command with correct parameters.
Host Communications Interface (HCI) Error Messages
4-15
Severity: Processing continues.
User Response: None.
HCIHC0038I @@ @@ COMMAND ACCEPTED
Explanation: The operator has entered a SWITCH, OPEN, or CLOSE command for the Journal facility. The command listed in the message is being processed.
Severity: Processing continues.
User Response: None.
HCIHC0039I @@ @@ TASK HAS BEEN DEACTIVATED
Explanation: The Journal task or a VTAM ACB processing subtask is being purged as a result of operator request. The name of the purged task is listed in the message.
Severity: Processing continues.
User Response: None.
HCIHC0040I @@ @@ TASK IS NOT ACTIVE
Explanation: For a Deactivate Task command, the task requested to be altered is already inactive. The Operator, Journal, or VTAM processing subtask name is listed in the message.
Severity: Processing continues.
User Response: None.
HCIHC0041I @@ @@ TASK IS ALREADY ACTIVE
Explanation: For a Reactivate Task command, the task requested to be altered is already started. The Operator, Journal, or VTAM processing subtask name is listed in the message.
Severity: Processing continues.
User Response: None.
HCIHC0042I @@ JOURNAL IS NOT OPEN
Explanation: The operator entered a SWITCH or CLOSE command to alter the Journal facility status. At the time the command was issued, the Journal files were not open.
Severity: Processing continues.
User Response: None.
HCIHC0043I @@ JOURNAL IS ALREADY OPEN
Explanation: The operator entered a OPEN command to alter the Journal facility status. At the time the command was issued, the Journal files were open.
Severity: Processing continues.
User Response: None.
HCIHC0044I @@ @@ JOURNAL RECORDS LOST
Explanation: Because of the processing load on the CPU, not all journal records were written to the journal file(s). Some trace data has been lost. The message includes the Subsystem ID and the number of lost trace records.
Severity: Processing continues.
User Response: None.
HCIHC0045I @@ JOURNAL SWAP REQUESTED BY TP=@@
Explanation: This is an informational message only, indicating that the TP named in the message has issued a CWSWAP call to cause the current journal data set to be closed and deallocated, and the next journal to be allocated and opened.
Severity: Processing continues.
User Response: None.
4-16
Enterprise Common Components Messages and Codes
HCIHC0046E @@ SETLOGON (GNAMEADD) COMPLETION ERROR. @@,@@
Explanation: This message indicates that an error has occurred in the attempt to issue the
VTAM request SETLOGON GNAMEADD. The message includes the error return codes from the
RPL and the sense code.
Severity: Processing continues.
User Response: None.
HCIHC0047E @@ SETLOGON (GNAMEDEL) COMPLETION ERROR. @@,@@
Explanation: This message indicates that an error has occurred in the attempt to issue the
VTAM request SETLOGON GNAMEDEL. The message includes the error return codes from the
RPL and the sense code.
Severity: Processing continues.
User Response: None.
HCIHC0048I @@ COUPLING FACILITY FOR THIS HOST UNAVAILABLE
Explanation: This message indicates that an error has occurred in the attempt to issue the
VTAM request SETLOGON GNAMEADD, and that the error was that the coupling facility is not available.
Severity: Processing continues.
User Response: None.
HCIHC0049I @@ GENERIC NAME @@ ADDED FOR APPLID @@
Explanation: This message indicates that the specified generic name has been added as an alias for the specified actual name.
Severity: Processing continues.
User Response: None.
HCIHC0050I @@ GENERIC NAME @@ DELETED FOR APPLID @@
Explanation: This message indicates that the specified generic name has been deleted as an alias for the specified actual name.
Severity: Processing continues.
User Response: None.
HCIHC0051E @@ UNABLE TO ESTABLISH ENF EXIT. RC= @@
Explanation: This message indicates that a non-zero return code resulted from an ENFREQ
ACTION=LISTEN macro. The return code is displayed.
Severity: Processing continues.
User Response: None.
HCIHC0052E @@ PARMLIB MEMBER @@ FOR TP @@ CANNOT BE READ
Explanation: This message indicates that the HCI PARMLIB member named cannot be read, when attempting to activate the named TP. Most probably, the member does not exist in the data set.
Severity: The pending conversation is deallocated and control blocks are released.
User Response: Insure that the JCL exists in the PARMLIB and retry the conversation request.
HCIHC0053E @@ SDUMP FAILED WITH RC=@@
Explanation: This message indicates that an attempt to take a dump to a SYS1.DUMPxx data set has failed. The return code from SDUMP is given.
Severity: Processing continues.
User Response: Processing continues.
Host Communications Interface (HCI) Error Messages
4-17
HCIHC0054E @@ SDUMP SUPPRESSED BY DAE
Explanation: This message indicates that the SDUMP named in message HC0053 has been suppressed by DAE, because the dump duplicates an identical one already taken.
Severity: Process continues.
User Response: If a dump is required, then enter IPCS under ISPF, and under UTILITIES and
DAE, enter a “T” in the command area next to the dump in question. This will force DAE to allow the next dump to be taken.
HCIHC0055E @@ HCI ABEND @@ IN @@ AT @@
Explanation: This message indicates that there has been an abend within the indicated HCI module, at the indicated location.
Severity: Process continues.
User Response: Refer this problem to the HCI support staff.
HCIHC0056I @@ NORMAL SHUTDOWN ALREADY IN PROGRESS. COMMAND IGNORED
Explanation: This message indicates that the operator had already entered a “SHUTDOWN
NORMAL” command, and before the HCI actually ended, entered another one.
Severity: The command is ignored.
User Response: Allow normal shutdown to complete, or enter a “SHUTDOWN IMMED” command.
HCIHC0057I @@ NORMAL SHUTDOWN PROCESSING HAS BEEN INITIATED
Explanation: This message indicates that the operator entered a “SHUTDOWN NORMAL” command, and that normal end of job processing has been initiated.
Severity: End of job processing continues.
User Response: None.
HCIHC0058I @@ NORMAL SHUTDOWN PROCESSING IS CONTINUING
Explanation: This message indicates that the operator entered a “SHUTDOWN NORMAL” command, and that normal end of job processing is still in progress.
Severity: End of job processing continues.
User Response: None.
HCIHC0059I @@ TASK @@ IS CONNECTED TO @@ REMOTE PARTNER(S)
Explanation: This message indicates that the task named in the message is still connected to the indicated number of remote partners, and that HCI termination will not continue until all of these connections have ended.
Severity: End of job processing continues.
User Response: None.
HCIHC0060I @@ @@ OF @@ @@ CONTROL BLOCKS IN USE
Explanation: This message indicates that, for the indicated control block type, usage is at or above 80 percent of maximum.
Severity: Processing continues.
User Response: Consider increasing the maximum number of control blocks of the indicated type, by modifying your HCI configuration module.
HCIHC0091I **** INITIALIZATION STARTED, ENDS WITH MESSAGE HCIHC0092I
Explanation: The initialization phase of the HCI has started. The HCIHC0092I message signals the end of this initialization. If the HCIHC0092I message does not appear in a reasonable amount of time, say 2 minutes, check for possible causes listed under the
HCIHC0092I message.
Severity: None.
User Response: None.
4-18
Enterprise Common Components Messages and Codes
HCIHC0092I @@ INITIALIZATION COMPLETE, HCI ACTIVE
Explanation: The initialization phase of the HCI has completed. It is now active.
Severity: None.
User Response: None, if message appears. This message appears after the synchronous initialization is complete. There can be other asynchronous initialization messages following this one - HCIHC0031I and HCIHC0036I for example. If the message does not appear, then check the following:
1. If TCP/IP is defined in one of the HCICNAMB configuration entries, make sure that the TCP/IP maintenance is current - UP-TO-DATE.
2. Check for resource enqueue conflicts for those data sets referenced by the HCI JCL.
3. Make sure all access methods defined in the HCICNAMB configuration, e.g., TCP/IP, are active.
4. Check the dispatching priority for the HCI. It should be treated as a server and have a priority higher than the applications it services but lower than the access methods that service it.
HCIHC0100E @@ UNABLE TO CONNECT TO TCPACCESS NAMED @@
Explanation: For the indicated Subsystem ID, the HCI is unable to establish a connection with the TCPACCESS named in this message.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0101E @@ TCPACCESS TACCEPT COMPLETION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TACCEPT macro. The contents of R15 and R0 and of the TPL return code fields are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0102E @@ TCPACCESS TACCEPT INITIATION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TACCEPT macro. The contents of R15 and R0 and of the TPL return code fields are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0103E @@ TCPACCESS TCLOSE PCB EXECUTION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TCLOSE macro. The contents of R15 and R0 and of the TPL return code fields are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0104E @@ TCPACCESS TCLOSE TSB EXECUTION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TCLOSE macro. The contents of R15 and R0 and of the TPL return code fields are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0105E @@ TCPACCESS AOPEN EXECUTION ERROR. R15=@@ R0=@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS AOPEN macro. The contents of R15 and R0 are given.
Severity: Processing continues.
Host Communications Interface (HCI) Error Messages
4-19
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0106E @@ TCPACCESS TOPEN PCB EXECUTION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TOPEN macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0107E @@ TCPACCESS TINFO EXECUTION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TINFO macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0108E @@ TCPACCESS TBIND EXECUTION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TBIND macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0109E @@ TCPACCESS TLISTEN COMPLETION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TLISTEN macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0110E @@ TCPACCESS TOPEN TSB EXECUTION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TOPEN macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0111E @@ TCPACCESS TLISTEN INITIATION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TLISTEN macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0112E @@ TCPACCESS TRECV INITIATION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TRECV macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0113E @@ TCPACCESS TCONNECT INITIATION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TCONNECT macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0114E @@ TCPACCESS TCONFIRM INITIATION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from A
TCPACCESS TCONFIRM MACRO. THE CONTENTS OF R15 AND R0 ARE GIVEN.
4-20
Enterprise Common Components Messages and Codes
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0115E @@ TCPACCESS TCONFIRM COMPLETION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from A
TCPACCESS TCONFIRM MACRO. THE CONTENTS OF R15 AND R0 ARE GIVEN.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0116E @@ TCPACCESS TCONNECT COMPLETION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from A
TCPACCESS TCONNECT MACRO. THE CONTENTS OF R15 AND R0 ARE GIVEN.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0117E @@ TCPACCESS TSEND COMPLETION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from A
TCPACCESS TSEND MACRO. THE CONTENTS OF R15 AND R0 ARE GIVEN.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0118E @@ TCPACCESS TRECV COMPLETION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TRECV macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0119E @@ TCPACCESS TSEND INITIATION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TSEND macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0120E @@ TCPACCESS TRELEASE TSB EXECUTION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TRELEASE macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0121E @@ TCPACCESS TRELEASE PCB EXECUTION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TRELEASE macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0122E @@ TCPACCESS TOPTION EXECUTION ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS TOPTION macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
Host Communications Interface (HCI) Error Messages
4-21
HCIHC0123E @@ TCPACCESS DIRECTORY SERVICES ERROR: @@,@@,@@
Explanation: For the indicated Subsystem ID, a non-zero return code resulted from a
TCPACCESS DIRSRV macro. The contents of R15 and R0 are given.
Severity: Processing continues.
User Response: Insure that the named TCPACCESS is active on the system.
HCIHC0200I @@ HCI @@ HAS JOINED SYSPLEX GROUP @@ SUCCESSFULLY
Explanation: For the indicated Subsystem ID, this message indicates that the HCI has successfully joined the sysplex group named in this message.
Severity: Processing continues.
User Response: Processing continues.
HCIHC0201E @@ HCI @@ HAS FAILED TO JOIN SYSPLEX GROUP @@
Explanation: For the indicated Subsystem ID, this message indicates that the HCI has not been able to join the sysplex group named in this message.
Severity: Processing continues.
User Response: Processing continues.
HCIHC0202E @@ XCF FUNCTION @@ FAILED. RETCODE=@@. REASON=@@
Explanation: For the indicated Subsystem ID, this message indicates that the named XCF function has failed with the return and reason codes given.
Severity: Processing continues.
User Response: Processing continues.
HCIHC0203I @@ GROUP @@ CONTAINS ACTIVE MEMBER @@
Explanation: For the indicated Subsystem ID and sysplex subsystem id, the HCI has found the named member to be active in the sysplex group.
Severity: Processing continues.
User Response: Processing continues.
HCIHC0600C @@ TCP/IP @@ ERROR. RETCODE=@@ ERRNO=@@
Explanation: For the indicated Subsystem ID, TCP/IP has returned a negative value, indicating an event failure. The name of the event, the return code and the error number are given in this message.
Severity: Processing continues.
User Response: Refer to the TCP/IP Messages and Codes manual for an explanation of the error message number.
– Install Note for TCP/IP release 3.1.0: Insure PTF UN97857 is on.
– Install Note for TCP/IP release 3.1.1: Insure PTF UN97858 or higher is on.
– Install Note for TCP/IP release 3.2.0: Insure PTF UQ19522 is on.
HCIHC0601C @@ UNABLE TO ESTABLISH CONNECTION WITH TCP/IP NAMED @@
Explanation: For the indicated Subsystem ID, the HCI has attempted to establish a connection with the named TCP/IP address space, and has been unsuccessful.
Severity: Processing continues.
User Response: If TCP/IP is required for processing, stop the HCI and correct the problem.
Otherwise, processing will continue without the named TCP/IP address space.
HCIHC0602C @@ UNABLE TO BIND PORT NUMBER @@ WITH SOCKET NUMBER @@
Explanation: For the indicated Subsystem ID, the HCI has attempted to bind the named port with the named socket, and has been unsuccessful.
Severity: Processing continues.
4-22
Enterprise Common Components Messages and Codes
User Response: If the port named in this message is required, stop the HCI and correct the problem. Otherwise, processing will continue without this port number.
HCIHC0603I @@ @@ UNCORRELATED CONVERSATION DATA IGNORED
Explanation: Conversation data has been ignored because it cannot be determined where it is to be passed. If possible, the userid is provided. This is usually caused when a TP abnormally terminates and active conversations are still being processed. But, it is possible that the dispatching priorities are not correct between the protocol server (TCP), HCI and TP.
Severity: Processing continues.
User Response: Investigate the TP abend and make any necessary corrections. If there was no abending TP, then check the dispatching priorities. The relative priorities from highest to lowest should be as follows: protocol server (TCP) then HCI then the TP. The HCI should have a dispatching priority like CICS since it services multiple clients (TPs).
HCIHC0701C @@-UNABLE TO LOAD INITIALIZATION MODULE HCIMINIT
Explanation: For the indicated Subsystem ID, HCI initialization attempted to load the named module. The LOAD did not succeed. Since this module is needed for setup of the HCI data areas, ABEND was issued to terminate the HCI job. The LOAD could have failed due to a storage shortage, or the load module not found in the allocated files.
Severity: Processing continues.
User Response: None.
HCIHC0702C @@-UNABLE TO GET STORAGE FOR JCA (SP=0,LOC=ANY)
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0703C @@-UNABLE TO GET STORAGE FOR SAVE AREAS (SP=0,LOC=BELOW)
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0704C @@-UNABLE TO GET STORAGE FOR SAVE AREAS (SP=241,LOC=ANY)
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0705C @@-UNABLE TO GET STORAGE FOR GCA (SP=241,LOC=ANY)
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0800C @@-NON-ZERO RETURN CODE FROM SHOWCB. R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, length of VTAM control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Host Communications Interface (HCI) Error Messages
4-23
Severity: Processing continues.
User Response: None.
HCIHC0801C @@-UNABLE TO GET STORAGE FOR VTAM CTL BLOCKS (SP=0), GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0802C @@-NONZERO RETURN CODE FROM GENCB. R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, lack of storage, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
HCIHC0803C @@-NONZERO RETURN CODE FROM ATTACH. R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, storage for MVS control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
HCIHC0804C @@-NONZERO RETURN CODE FROM CPOOL BUILD FOR DCB POOL. R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, storage for control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
HCIHC0805C @@-NONZERO RETURN CODE FROM CPOOL BUILD FOR RPL POOL. R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, storage for control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
HCIHC0806C @@-NONZERO RETURN CODE FROM CPOOL BUILD FOR CCB POOL. R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, storage for control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
4-24
Enterprise Common Components Messages and Codes
HCIHC0807C @@-NONZERO RETURN CODE FROM CPOOL BUILD FOR LUB POOL. R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, storage for control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
HCIHC0808C @@-NONZERO RETURN CODE FROM CPOOL BUILD FOR RCB POOL. R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, storage for control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
HCIHC0811C @@-UNABLE TO GET STORAGE FOR ORE QUEUE, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0813C @@-UNABLE TO GET STORAGE FOR CCB HASH TABLE, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0814C @@-UNABLE TO GET STORAGE FOR SIT HASH TABLE, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0815C @@-UNABLE TO LOAD MODULE TO SUBPOOL 245, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, HCI initialization attempted to load the named module. The LOAD did not succeed. Since this module is needed for setup of the HCI data areas, ABEND was issued to terminate the HCI job. The LOAD could have failed due to a storage shortage, or the load module not found in the allocated files.
Severity: Processing continues.
User Response: None.
HCIHC0816C @@-UNABLE TO LOAD REQUIRED MODULE. LOAD R/C=@@
Explanation: For the indicated Subsystem ID, HCI initialization attempted to load a required module. The LOAD did not succeed. Since this module is needed for setup of the HCI data areas, ABEND was issued to terminate the HCI job. The LOAD could have failed due to a storage shortage, or the load module not found in the allocated files.
Severity: Processing continues.
User Response: None.
Host Communications Interface (HCI) Error Messages
4-25
HCIHC0818C SUBSYSTEM @@ IS ALREADY ACTIVE ON THIS SYSTEM
Explanation: The subsystem identified by this message was found to be already active in the
MVS system. This information was found at a point in initialization where it is impossible to prompt for a new Subsystem ID and continue initialization. ABEND is issued to terminate the
HCI job. Ensure that the Subsystem ID is unique, or that a recent HCI job has completely ended.
Severity: Processing continues.
User Response: None.
HCIHC0819C @@-NONZERO RETURN CODE FROM ESTAE MACRO, R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, storage for control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
HCIHC0820C @@-NONZERO RETURN CODE FROM STIMERM MACRO, R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, storage for control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
HCIHC0821C @@-SERVER REGION ABORTED AT OPERATOR REQUEST
Explanation: For the indicated Subsystem ID, the operator issued a request to terminate a specific HCI server. The supporting region and job have been ended. This message is a confirmation of the completion of the operator's previous request.
Severity: Processing continues.
User Response: None.
HCIHC0822C @@-UNABLE TO GET STORAGE FOR CSA MODULES, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0823C @@-UNABLE TO GET STORAGE FOR CSA MODULES, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0824C @@-UNABLE TO GET STORAGE FOR CSA MODULES, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
4-26
Enterprise Common Components Messages and Codes
HCIHC0825C @@ ALREADY ACTIVE ON THIS SYSTEM IS NOT AN HCI SUBSYSTEM
Explanation: HCI initialization has discovered another subsystem active with the same
Subsystem ID. After checking data in the Subsystem MVS control blocks, it was determined that the active system is not an HCI. Have the active subsystem shutdown, and then the HCI will initialize normally.
Severity: Processing continues.
User Response: None.
HCIHC0900C @@-NONZERO RETURN CODE FROM CPOOL BUILD FOR AMB POOL. R/C=@@
Explanation: For the indicated Subsystem ID, the named macro was issued to obtain information needed to initialize the HCI control blocks. The macro gave a return code which is listed in the message. The HCI will be terminated via ABEND since data needed for initialization, storage for control blocks, for example, is unavailable. Check the documentation of the named macro for explanation of the listed return code.
Severity: Processing continues.
User Response: None.
HCIHC0901C @@-UNABLE TO GET STORAGE FOR JCB AREAS, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0902C @@-UNABLE TO GET STORAGE FOR SIT AREAS, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0903C @@-UNABLE TO GET STORAGE FOR TPT AREAS, GETMAIN R/C=@@
Explanation: For the indicated Subsystem ID, GETMAIN was issued to allocate storage for the named area. The macro call failed. This storage is required for proper HCI operation. Therefore,
ABEND is issued to terminate the HCI job.
Severity: Processing continues.
User Response: None.
HCIHC0904C @@-UNABLE TO DETERMINE LOCATION OF CONFIGURATION TABLE
Explanation: For the indicated Subsystem ID, HCI tried to locate the initialization parameters in a member in the configuration library. Either the library or the configuration member could not be located and processed. Check and correct the JCL definition of the configuration data library and members and rerun the HCI job.
Severity: System Action: Processing continues.
User Response: None.
HCIHC0970C @@-UNABLE TO LOAD OPERATOR COMM. INITIALIZATION MODULE
Explanation: For the indicated Subsystem ID, HCI initialization attempted to load the named module. The LOAD did not succeed. Since this module is needed for setup of the HCI data areas, ABEND was issued to terminate the HCI job. The LOAD could have failed due to a storage shortage, or the load module not found in the allocated files.
Severity: Processing continues.
User Response: None.
Host Communications Interface (HCI) Error Messages
4-27
HCIHC0975C @@-UNABLE TO LOAD MODULES REQUIRED BY OPERATOR COMMUNICATIONS
Explanation: For the indicated Subsystem ID, HCI initialization attempted to load the named modules. The LOAD did not succeed. Since this module is needed for setup of the HCI data areas, ABEND was issued to terminate the HCI job. The LOAD could have failed due to a storage shortage, or the load module not found in the allocated files.
Severity: Processing continues.
User Response: None.
HCIHC1000I @@ DISPLAY FOR SUBSYSTEM @@ ON @@
Explanation: This is the first message in a message group which is displayed as the result of a
DISPLAY ALL operator command. The message identifies the SYSID of the active HCI and the
SMF identifier of the subsystem. See also messages HC1001, HC1002, HC1003, HC1004 and
HC1005.
Severity: Processing continues.
User Response: None.
HCIHC1001I @@ JOBNAME = @@, STEPNAME = @@
Explanation: This message is part of a message group which begins with message HC1000.
This message identifies name and Step name of the subsystem SYSID named in the message.
Severity: Processing continues.
User Response: None.
HCIHC1002I @@ HCI STATUS BYTES = @@
Explanation: This message is part of a message group which begins with message HC1000.
For the subsystem SYSID named in the message, the status bits are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1003I @@ ESTAE DUMP UNIT NAME = @@, VOLSER = @@
Explanation: This message is part of a message group which begins with message HC1000.
For the subsystem SYSID named in the message, the name of the dump file unit name and the volume serial of the disk where the dump will be stored. The unit name is the standard MVS unit name; for example, SYSDA, TAPE, VIO.
Severity: Processing continues.
User Response: None.
HCIHC1004I @@ ESTAE DUMP DSNAME PREFIX = @@
Explanation: This message is part of a message group which begins with message HC1000.
For the subsystem SYSID named in the message, the DSNAME PREFIX is the high-level qualifier which will be used for the name of the dataset containing a HCI dump.
Severity: Processing continues.
User Response: None.
HCIHC1005I @@ JOURNAL ACTIVITY FLAGS = @@
Explanation: This message is part of a message group which begins with message HC1000.
The status bytes relating to the Journal facility of the subsystem SYSID named in the message, are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1006I @@ DDNAME VOLSER STATUS DSNAME
Explanation: This is the first message of a group which is displayed in response to a DISPLAY
J or JOURNAL command. See also message HC1007. For the subsystem SYSID named, this message is a heading for a tabular display of Journal file information.
4-28
Enterprise Common Components Messages and Codes
Severity: Processing continues.
User Response: None.
HCIHC1007I @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1006.
Each line will be a repetition of HC1007. For the subsystem SYSID named in the message, data about 1 Journal file will be displayed. The file data will be the DDNAME which did the allocation, the serial of the volume on which the Journal file resides, the MVS dataset name of the Journal file, and an indication whether or not the Journal file is opened and in use.
Severity: Processing continues.
User Response: None.
HCIHC1011I @@ HCIAPING APINGD STARTED
Explanation: This message is the first message displayed by the internal TP, HCIAPING. This message indicates that communication with a remote partner APING program has started.
Severity: Processing continues.
User Response: None.
HCIHC1012I @@ HCIAPING APINGD ENDED
Explanation: This message is the last message displayed by the internal TP, HCIAPING. This message indicates that communication with a remote partner APING program has ended.
Severity: Processing continues.
User Response: None.
HCIHC1013I @@ HCIAPING SESSION WITH @@ STARTED
Explanation: This message is part of the messages displayed by the internal TP, HCIAPING.
This message indicates that a session with the partner LU named has started.
Severity: Processing continues.
User Response: None.
HCIHC1014I @@ HCIAPING SESSION WITH @@ ENDED @@
Explanation: This message is part of the messages displayed by the internal TP, HCIAPING.
This message indicates that the session with the partner LU named has ended.
Severity: Processing continues.
User Response: None.
HCIHC1015I @@ HCIAPING MESSAGES READ @@
Explanation: This message is part of the messages displayed by the internal TP, HCIAPING.
This message indicates the number of messages read from the partner LU.
Severity: Processing continues.
User Response: None.
HCIHC1016I @@ HCIAPING MESSAGES WRITTEN @@
Explanation: This message is part of the messages displayed by the internal TP, HCIAPING.
This message indicates the number of messages written to the partner LU.
Severity: Processing continues.
User Response: None.
HCIHC1017I @@ HCIAPING ATELL MESSAGE FROM @@ FOLLOWS:
Explanation: This message is displayed when the partner LU is running the ATELL client program, and has sent a message to the host. The text of this message is shown in the next message, HC1018.
Severity: Processing continues.
Host Communications Interface (HCI) Error Messages
4-29
User Response: None.
HCIHC1100I @@ ACB NAME = @@, APPLID = @@, VERSION = @@
Explanation: This is the first message in a message group which is displayed as the result of a
DISPLAY ALL operator command. This message group displays the status of a job running a
VTAM application which is managed by the subsystem SYSID named in this message.
APPLNAME in the message identifies the VTAM name of the application. The version of the running VTAM is extracted from the vector returned on OPEN ACB and is listed in this message. See also messages HC1101, HC1102 and HC1103.
Severity: Processing continues.
User Response: None.
HCIHC1101I @@ SUBTASK STATUS = @@
Explanation: This message is part of a message group which begins with message HC1100.
For the subsystem SYSID named in the message, the status bytes of the VTAM application ACB subtask are displayed. This subtask is related to the Application named in message HC1100.
Severity: Processing continues.
User Response: None.
HCIHC1102I @@ MAIN PROGRAM EXECUTED = @@
Explanation: This message is part of a message group which begins with message HC1100.
The HCI subsystem SYSID is named in the message. The name of the program executed as part of this application job step is shown in PGMNAME in the message.
Severity: Processing continues.
User Response: None.
HCIHC1103I X @@ TIMES ATTACHED = @@, LAST ABEND = @@
Explanation: This message is part of a message group which begins with message HC1100.
The active subsystem is displayed as SYSID. For the subsystem SYSID shown, this message shows how many times that the VTAM processing subtask asked for the application named in
HC1100 to be attached. Also, if there was a prior ABEND, that ABEND code is shown in
ABNCODE.
Severity: Processing continues.
User Response: None.
HCIHC1200I @@ REGION JOBNAME @@ STEPNAME @@ PROCSTEP @@
Explanation: This is the first message in a message group which is displayed as the result of a
DISPLAY ALL operator command. The active subsystem is displayed as SYSID. This message group displays the status of a job running a server application. JOBNAME, STEPNAME and
PROCSTEP keyword values are taken from the MVS JCL statements which make up the job that started the server. See also message HC1201.
Severity: Processing continues.
User Response: None.
HCIHC1201I @@ REGION STATUS @@ ASID @@
Explanation: This message is part of a message group which begins with message HC1200.
For the subsystem named SYSID and the server job named in message HC1200, the Region
Control status bytes are displayed. Also, the MVS Address Space ID of the server job is shown.
Severity: Processing continues.
User Response: None.
HCIHC1300I @@ USER LOCAL TP_NAME @@ USERID @@
Explanation: This is the first message in a message group which is displayed as the result of a
DISPLAY ALL operator command. The active subsystem is displayed as SYSID. This message group displays the Userid and TP_Name of a server job running under the subsystem named
SYSID in the message.
4-30
Enterprise Common Components Messages and Codes
Severity: Processing continues.
User Response: None.
HCIHC1301I @@ USER STATUS @@
Explanation: This message is part of a message group which begins with message HC1300.
The active subsystem is displayed as SYSID. The status bytes of a userid which is active with the subsystem SYSID, is displayed.
Severity: Processing continues.
User Response: None.
HCIHC1302I @@ SYSTEM @@ HAS BECOME ACTIVE AND ELIGIBLE FOR TPS
Explanation: This message indicates that the named MVS system has just become eligible to receive “START” commands from the HCI in order to start TP programs.
Severity: Processing continues.
User Response: None.
HCIHC1303E @@ SYSTEM @@ HAS BECOME INACTIVE AND INELIGIBLE FOR TPS
Explanation: This message indicates that the named MVS system has just become inactive, and is no longer eligible to receive MVS “START” commands.
Severity: Processing continues.
User Response: None.
HCIHC1304E @@ SYSTEM @@ STILL PENDING HCIYPREP EXECUTION
Explanation: This message indicates that the named MVS system is active to the SYSPLEX, but is still waiting for HCIYPREP to execute to complete activation.
Severity: Processing continues.
User Response: None.
HCIHC1400I @@ SYM_DEST_NAME @@
Explanation: This is the first message in a group which is displayed as a result of the
DISPLAY ALL command. The active subsystem is displayed as SYSID. The name of the connection is given. This name was specified by the application on a CONNECT, or, if this conversation was started by receiving a FMH-5, then the name will be an 8-byte hexadecimal value. See also HC1401.
Severity: Processing continues.
User Response: None.
HCIHC1401I @@ SYM_DEST STATUS @@
Explanation: This message is part of a message group which begins with message HC1400.
The active subsystem is displayed as SYSID. The status bytes for the network connection are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1500I @@ CONVERSATION PARTNER_LU_NAME @@
Explanation: This is the first message in a group which is displayed as a result of the
DISPLAY ALL command. The active subsystem is displayed as SYSID. The name of the network resource, which has one or more conversations with the previously listed application, is included in this message. See also HC1501 and HC1502 for more information about conversations with this LU.
Severity: Processing continues.
User Response: None.
Host Communications Interface (HCI) Error Messages
4-31
HCIHC1501I @@ CONV STATUS @@ CONV STATE @@
Explanation: This message is part of a message group which begins with message HC1500.
The active subsystem is displayed as SYSID. The current state of the conversation being displayed is shown. For an interpretation of the hexadecimal number shown as CONV STATE, consult the CPI-C references.
Severity: Processing continues.
User Response: None.
HCIHC1502I @@ NUMBER RECEIVES @@ NUMBER SENDS @@
Explanation: This message is part of a message group which begins with message HC1500.
The active subsystem is displayed as SYSID. For the conversation listed in message HC1500, the number of messages sent and received are listed.
Severity: Processing continues.
User Response: None.
HCIHC1600I @@ BELOW 16M BELOW 16M ABOVE 16M ABOVE 16M
Explanation: This is the first message in a group which is displayed as a result of the
DISPLAY STORAGE command. The active subsystem is displayed as SYSID. This message is a heading line for storage statistics. See also HC1601, HC1602, HC1603, HC1604, HC1605,
HCI1606, and HCI1607.
Severity: Processing continues.
User Response: None.
HCIHC1601I @@ CURRENT HIGHEST CURRENT HIGHEST
Explanation: This message is part of a message group which begins with message HC1600.
The active subsystem is displayed as SYSID. This message is a heading line for storage statistics.
Severity: Processing continues.
User Response: None.
HCIHC1602I PRIVATE @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1600.
The current size of allocated storage and the highest size of storage ever allocated are listed for above and below the 16M line.
Severity: Processing continues.
User Response: None.
HCIHC1603I COMMON @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1600.
The current size of allocated storage and the highest size of storage ever allocated are listed for above and below the 16M line.
Severity: Processing continues.
User Response: None.
HCIHC1604I MODULE @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1600.
The current size of allocated storage and the highest size of storage ever allocated are listed for above and below the 16M line.
Severity: Processing continues.
User Response: None.
HCIHC1605I BUFFER @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1600.
The current size of allocated storage and the highest size of storage ever allocated are listed for above and below the 16M line.
4-32
Enterprise Common Components Messages and Codes
Severity: Processing continues.
User Response: None.
HCIHC1606I TOTAL @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1600.
The current size of allocated storage and the highest size of storage ever allocated are listed for above and below the 16M line.
Severity: Processing continues.
User Response: None.
Explanation: This message is part of a message group which begins with message HC1600.
This message shows the total storage allocated by the active HCI subsystem across all storage types, usage, and pools.
Severity: Processing continues.
User Response: None.
HCIHC1610I @@ CURRENT HIGHEST MAXIMUM %USED
Explanation: This is a heading line for information displayed as a result of the DISPLAY
CONTROL BLOCKS command. This is the first message in a group of messages including
HC1611, HC1612, HC1613, HC1614, HC1615, HC1616, HC1618, HC1619, HC1620, HC1621,
HC1622 and HC1623.
Severity: Processing continues.
User Response: None.
HCIHC1611I SAA @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation size, highest allocation size, maximum allowed, and percent used of the storage pool above the 16M line for SAA (saveareas) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1612I SAB @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool below the 16m line for SAB (saveareas) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1613I AMB @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for AMB (VTAM application related) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1614I CCB @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for CCB (conversation related) control blocks.
Severity: Processing continues.
User Response: None.
Host Communications Interface (HCI) Error Messages
4-33
HCIHC1615I DCB @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for DCB (symbolic destination related) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1616I JRE @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for JRE (Journal facility related) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1618I ORE @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for ORE (operator communications related) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1619I RCB @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for RCB (related to MVS server and client regions) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1620I RPL @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for RPL (VTAM Request Parameter List) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1621I TPT @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for TPT (transaction program profile related) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1622I UIB @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for UIB (User/Userid information related) control blocks.
Severity: Processing continues.
User Response: None.
HCIHC1623I WRE @@ @@ @@ @@
Explanation: This message is part of a message group which begins with message HC1610.
This display shows the current allocation, highest allocation, maximum allowed, and percent used of the storage pool for WRE (Work Request Elements, related to HCI internal scheduling of requests) control blocks.
4-34
Enterprise Common Components Messages and Codes
Severity: Processing continues.
User Response: None.
HCIHC1699E @@ REFRESH IS NOT SUPPORTED UNDER BASE SERVICES CONTROL
Explanation: This message indicates that the REFRESH command was entered, but since this
HCI is running under the Base Services component of PD, that REFRESH is not supported.
Severity: Processing continues.
User Response: None.
HCIHC1700I @@ CONFIGURATION VALUES FROM MODULE @@ ARE NOW IN EFFECT
Explanation: This message indicates that the configuration values which were specified in the module named in this message are now in effect.
Severity: Processing continues.
User Response: None.
HCIHC1701E @@ CONFIGURATION SUBSYSTEM MISMATCH. NEW SUBSYSTEM = @@
Explanation: This message indicates that the configuration table just loaded specifies a subsystem id that is different from the subsystem id of the current HCI.
Severity: The REFRESH is ignored.
User Response: Insure that the correct HCI has been chosen for the REFRESH command. If so, reassemble the configuration module, specifying the correct subsystem ID.
HCIHC1702I @@ OPEN ACB INTERVAL CHANGED FROM @@ TO @@
Explanation: This message indicates that the open acb interval has been changed. The old and the new values are displayed in decimal.
Severity: Processing continues.
User Response: None.
HCIHC1703I @@ MASTER INTERVAL CHANGED FROM @@ TO @@
Explanation: This message indicates that the master interval has been changed. The old and the new values are displayed in decimal.
Severity: Processing continues.
User Response: None.
HCIHC1704I @@ DUMP UNIT NAME CHANGED FROM @@ TO @@
Explanation: This message indicates that the dump unit name has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1705I @@ DUMP VOLSER CHANGED FROM @@ TO @@
Explanation: This message indicates that the dump volser has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1706I @@ DUMP SYSOUT CLASS CHANGED FROM @@ TO @@
Explanation: This message indicates that the dump sysout class has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
Host Communications Interface (HCI) Error Messages
4-35
HCIHC1707I @@ JES IDENTIFICATION CHANGED FROM @@ TO @@
Explanation: This message indicates that the JES type specification has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1708I @@ JES COMMAND CHARACTER CHANGED FROM @@ TO @@
Explanation: This message indicates that the JES command character has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1709I @@ DUMP DATA SET NAME CHANGED FROM @@ TO @@
Explanation: This message indicates that the dump data set name has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1710I @@ JOURNAL MASK CHANGED FROM @@ TO @@
Explanation: This message indicates that the journal mask has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1711I @@ JOBNAME PREFIX CHANGED FROM @@ TO @@
Explanation: This message indicates that the jobname prefix has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1712I @@ DEFAULT USERID CHANGED FROM @@ TO @@
Explanation: This message indicates that the default userid has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1713I @@ JES/3 MAIN NAME CHANGED FROM @@ TO @@
Explanation: This message indicates that the JES/3 main name has been changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1714I @@ JOURNAL ADDED. DDNAME=@@ DSNAME=@@
Explanation: This message indicates that the a new journal data set has been added. The new
DDNAME and the new DSNAME are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1715I @@ NO CONFIGURATION CHANGES MADE TO RUNNING HCI
Explanation: This message indicates that the new configuration module was loaded and was processed, but that there were either no differences found in it from the running configuration or the differences found were not eligible for dynamic refresh.
Severity: Processing continues.
4-36
Enterprise Common Components Messages and Codes
User Response: None.
HCIHC1716E @@ MODULE @@ CONTAINING MESSAGE @@ NOT FOUND
Explanation: This message indicates that the a call was made to display the message named, but the module that was supposed to contain this message did not exist in the HCI STEPLIB.
Severity: Processing continues.
User Response: Verify that the message ID is valid and insure that the module containing this message has been link edited into the STEPLIB data set.
HCIHC1717E @@ MESSAGE @@ NOT FOUND IN MODULE @@
Explanation: This message indicates that the a call was made to display the message named, but that message was not found in the proper load module, also named.
Severity: Processing continues.
User Response: Verify that the message ID is valid and insure that the module containing this message has been link edited into the STEPLIB data set.
HCIHC1718I VARIABLE DATA = @@ @@ @@ @@
Explanation: This message displays the variable data that was to be displayed in the message that could not be found, and which was described in message HC1716 or HC1717.
Severity: Processing continues.
User Response: None.
HCIHC1719I JOB NAME = @@ TP NAME = @@
Explanation: This message indicates the tp name of the module who requested an invalid message, which was described in message HC1716 or HC1717.
Severity: Processing continues.
User Response: None.
HCIHC1720I @@ PARTNER LU NAME FOR SYMDEST @@ CHANGED FROM @@ TO @@
Explanation: This message indicates the old and the new PARTNER_LU_NAMEs, which have been changed in the sit entry named by the specified SYMDEST.
Severity: Processing continues.
User Response: None.
HCIHC1721I @@ MODE NAME FOR SYMDEST @@ CHANGED FROM @@ TO @@
Explanation: This message indicates the old and the new MODE NAMES, which have been changed in the sit entry named by the specified SYMDEST.
Severity: Processing continues.
User Response: None.
HCIHC1722I @@ TP NAME FOR SYMDEST @@ CHANGED FROM @@ TO @@
Explanation: This message indicates the old and the new TP NAMES, which have been changed in the sit entry named by the specified SYMDEST.
Severity: Processing continues.
User Response: None.
HCIHC1723I @@ MIN CONT WINNER FOR SYMDEST @@ CHANGED FROM @@ TO @@
Explanation: This message indicates the old and the new minimum contention winner session value in the sit entry named by the specified SYMDEST.
Severity: Processing continues.
User Response: None.
Host Communications Interface (HCI) Error Messages
4-37
HCIHC1724I @@ MIN CONT LOSER FOR SYMDEST @@ CHANGED FROM @@ TO @@
Explanation: This message indicates the old and the new minimum contention loser session value in the sit entry named by the specified SYMDEST.
Severity: Processing continues.
User Response: None.
HCIHC1725I @@ LOCAL LU NAME FOR SYMDEST @@ CHANGED FROM @@ TO @@
Explanation: This message indicates the old and the new local lu names in the sit entry named by the specified SYMDEST.
Severity: Processing continues.
User Response: None.
HCIHC1726I @@ DEFAULT USERID FOR SYMDEST @@ CHANGED FROM @@ TO @@
Explanation: This message indicates the old and new USERIDs in the sit entry named by the specified SYMDEST.
Severity: Processing continues.
User Response: None.
HCIHC1727I @@ DEFAULT USERID FOR SYMDEST @@ HAS BEEN CHANGED
Explanation: This message indicates that the default PASSWORD for the SYMDEST named in the message has been changed. The old and new passwords are not displayed.
Severity: Processing continues.
User Response: None.
HCIHC1728I @@ IP ADDRESS FOR SYMDEST @@ HAS CHANGED FROM @@ TO @@
Explanation: This message indicates that the IP address for the SYMDEST named in the message has been changed. The old and new addresses are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1729I @@ PORT NUMBER FOR SYMDEST @@ HAS CHANGED FROM @@ TO @@
Explanation: This message indicates that the IP port number for the SYMDEST named in the message has been changed. The old and new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1730I @@ TCP/IP NAME FOR SYMDEST @@ HAS CHANGED FROM @@ TO @@
Explanation: This message indicates that the TCP/IP name for the SYMDEST named in the message has been changed. The old and new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1731I @@ MAX LU 6.2 SESS FOR SYMDEST @@ HAS CHANGED FROM @@ TO @@
Explanation: This message indicates that the maximum number of lu 6.2 sessions for the
SYMDEST named in this message has been changed. The old and new names are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1732E @@ CANNOT UPDATE/ADD SIT FOR SYMDEST @@. NO PCB FOR PORT @@
Explanation: This message indicates that the a new sit entry was found in the configuration module, but that it contained a port number which did not have a corresponding PCB.
Severity: Processing continues.
4-38
Enterprise Common Components Messages and Codes
User Response: None.
HCIHC1733E @@ CANNOT UPDATE/ADD SIT FOR SYMDEST @@. NO AMB FOR TCPNAME @@
Explanation: This message indicates that the a new sit entry was found in the configuration module, but that it contained a TCP/IP name which did not have a corresponding AMB.
Severity: Processing continues.
User Response: None.
HCIHC1734I @@ NEW SIT ENTRY FOR SYMDEST @@ ADDED
Explanation: This message indicates that the a new sit with the specified name has been added to the sit table.
Severity: Processing continues.
User Response: None.
HCIHC1735I @@ NEW AMB ENTRY FOR @@ NAMED @@ HAS BEEN ADDED
Explanation: This message indicates that a new AMB with the indicated name fir the indicated protocol has been added to the running HCI.
Severity: Processing continues.
User Response: None.
HCIHC1736I @@ MEMBER NAME FOR TP @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that member name for the indicated TP profile entry has been changed. The old and new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1737I @@ MAX CONVERSATIONS FOR TP @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that value representing the maximum number of conversations that a single instance of a TP can handle has changed. The old and new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1738I @@ RECEIVE BUFFER FOR TP @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that value representing the maximum receive buffer length for the specified TP has changed. the old and new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1739I @@ MAX TP COUNT FOR TP @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that the value representing the maximum number of TP regions for the specified TP has changed. the old and new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1740I @@ MAX SUBMIT TIME FOR TP @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that the value representing the maximum number of seconds a TP may remain pending submit has changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
Host Communications Interface (HCI) Error Messages
4-39
HCIHC1741I @@ MAX START TIME FOR TP @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that the value representing the maximum number of seconds a TP may remain pending start has changed. The old and the new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1742I @@ JOBNAME PREFIX FOR TP @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that the JOBNAME prefix for the indicated TP has changed. The old and new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1743I @@ NEW TPT ENTRY FOR TP NAME @@ ADDED
Explanation: This message indicates that the TPT entry for the specified TPNAME has been added to the running HCI.
Severity: Processing continues.
User Response: None.
HCIHC1744I @@ TP NAME FOR PCB PORT @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that the TPNAME specification in the indicated PCB has been changed. The old and new values are given.
Severity: Processing continues.
User Response: None.
HCIHC1745I @@ NEW PCB ENTRY FOR PORT @@ ADDED
Explanation: This message indicates that the new PCB with the specified PORT number has been added to the running HCI.
Severity: Processing continues.
User Response: None.
HCIHC1746E @@ CANNOT ADD PCB FOR PORT @@. NO AMB FOR TCPNAME @@
Explanation: This message indicates that a new PCB was specified in the configuration module, but that there is no AMB with a matching TCPNAME. The PCB is not added.
Severity: Processing continues.
User Response: None.
HCIHC1747E @@ CANNOT ADD PCB FOR PORT @@. NO TPT FOR TPNAME @@
Explanation: This message indicates that a new PCB was specified in the configuration module, but that there is no TPT entry with a matching TPNAME. The PCB is not added.
Severity: Processing continues.
User Response: None.
HCIHC1748E @@ UNABLE TO LOAD MODULE @@ FROM FDBDRPL DD CONCATENATION
Explanation: This message indicates that in response to an operator entered “REFRESH xxxxxxxx” command, the module named in the command was not found in the FDBDRPL DD data set concatenation.
Severity: Processing continues.
User Response: None.
HCIHC1749I @@ PASSWORD FOR TCPACCESS AMB @@ HAS BEEN CHANGED
Explanation: This message indicates that in response to an operator entered “REFRESH xxxxxxxx” command, the password in the TCPACCESS AMB was changed. The passwords are not displayed.
4-40
Enterprise Common Components Messages and Codes
Severity: Processing continues.
User Response: None.
HCIHC1750E @@ CHANGING TCP/IP ACCESS METHODS FOR @@ IS NOT SUPPORTED
Explanation: This message indicates that in response to an operator entered “REFRESH xxxxxxxx” command, the AMB entry in the running system was not changed because to do so would change the access method. This change is not allowed in a dynamic refresh.
Severity: Processing continues.
User Response: None.
HCIHC1751I @@ ALIAS NAME FOR TP @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that alias name for the indicated TP profile entry has been changed. The old and new values are displayed.
Severity: Processing continues.
User Response: None.
HCIHC1752I @@ TP @@ HAS BEEN MADE AN ALIAS FOR TP @@
Explanation: This message indicates that the tp named has become an alias tp. Previously, it was a real tp entry.
Severity: Processing continues.
User Response: None.
HCIHC1753I @@ REAL TP @@ DOES NOT EXIST TO BE ALIAS FOR @@
Explanation: This message indicates that an alias name for a tp was entered, but the named tp does not exist.
Severity: Processing continues.
User Response: None.
HCIHC1754I @@ ALIAS @@ REMOVED FROM TP @@
Explanation: This message indicates that the tp named has become a real tp. Previously, it was an alias tp entry.
Severity: Processing continues.
User Response: None.
HCIHC1755I @@ IP NAME FOR SYMDEST @@ CHANGED FROM @@ TO @@
Explanation: This message indicates the old and the new IP NAMES, which have been changed in the SIT entry named by the specified SYMDEST.
Severity: Processing continues.
User Response: None.
HCIHC1756I @@ SECURITY FACILITY NAME CHANGED FROM @@ TO @@
Explanation: This message indicates that the security facility name has been changed. The old and new values are displayed, truncated to 32 characters if necessary.
Severity: Processing continues.
User Response: None.
HCIHC1757I @@ CATEGORY FOR TP @@ CHANGED FROM @@ TO @@
Explanation: This message indicates that the category for the indicated TP profile entry has been changed. The old and new values are displayed.
Severity: Processing continues.
User Response: None.
Host Communications Interface (HCI) Error Messages
4-41
HCIHC1811I @@ HCIPSCHG PASSWORD MAINTENANCE STARTED
Explanation: This message is the first message displayed by the internal TP, HCIPSCHG. This message indicates that communication with a remote partner APING program has started.
Severity: Processing continues.
User Response: None.
HCIHC1812I @@ HCIPSCHG PASSWORD MAINTENANCE ENDED
Explanation: This message is the last message displayed by the internal TP, HCIPSCHG. This message indicates that communication with a remote partner APING program has ended.
Severity: Processing continues.
User Response: None.
HCIHC1813I @@ HCIPSCHG SESSION WITH @@ STARTED
Explanation: This message is part of the messages displayed by the internal TP, HCIPSCHG.
This message indicates that a session with the partner LU named has started.
Severity: Processing continues.
User Response: None.
HCIHC1814I @@ HCIPSCHG SESSION WITH @@ ENDED @@
Explanation: This message is part of the messages displayed by the internal TP, HCIPSCHG.
This message indicates that the session with the partner LU named has ended.
Severity: Processing continues.
User Response: None.
HCIHC1815I @@ HCIPSCHG MESSAGES READ @@
Explanation: This message is part of the messages displayed by the internal TP, HCIPSCHG.
This message indicates the number of messages read from the partner LU.
Severity: Processing continues.
User Response: None.
HCIHC1816I @@ HCIPSCHG MESSAGES WRITTEN @@
Explanation: This message is part of the messages displayed by the internal TP, HCIPSCHG.
This message indicates the number of messages written to the partner LU.
Severity: Processing continues.
User Response: None.
HCIHC1999I @@ END OF DISPLAY
Explanation: This message is written at the end of Operator DISPLAY command processing.
It serves to close the message group which displayed the information requested in the operator command.
Severity: Processing continues.
User Response: None.
HCIHC9000I @@ SUBSYSTEM @@ HAS ENDED
Explanation: This message is displayed by the Subsystem named, when it has determined that all the application programs, and the HCI itself, have ended, and services of this
Subsystem are no longer required. The Subsystem releases all storage allocated to it and terminates. Note that this message can be displayed even though the HCI is no longer active.
The Subsystem remains active even after the HCI has ended.
Severity: Processing continues.
User Response: None.