Fail Safe Control
Hardware Manual
Section 9:
Field Termination Assembly Modules
Copyright, Notices and Trademarks
© 1997 – Honeywell Safety Management Systems B.V.
Printed in the Netherlands
Revision 02 (10/97)
While this information is presented in good faith and believed to be accurate,
Honeywell Safety Management Systems B.V. disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages. The information and specifications in this document are subject to change without notice.
TotalPlant, TDC 3000 and Universal Control Network are U.S. registered trademarks of
Honeywell Inc.
FSC is a trademark of Honeywell Safety Management Systems B.V.
Other brands or product names are trademarks of their respective holders.
No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of
Honeywell Safety Management Systems B.V.
TABLE OF CONTENTS
Section 9: Field Termination Assembly Modules
Fail-safe active digital input FTA with line-monitoring (16 channels) ........................ 9-97
Digital output (relay) FTA for AK5/6 applications (4 channels) ............................... 9-103
Hardware Manual
Section 9: Field Termination Assembly Modules i
ii
Hardware Manual
Section 9: Field Termination Assembly Modules
FTA-E-01
Description
Fail-safe digital input FTA
(24/48/60 Vdc, 24 channels)
The field termination assembly module FTA-E-01 is the interface between the system interconnection cables (SIC) and the external field wiring (on E-56 ELCO).
Twenty-four channels (separated into three groups of eight channels with a 250 mA fuse in the common +) can be connected to the
FTA-E-01 module via system interconnection cables (SIC). These cables are plugged into the SIC connectors on the FTA module. The three SIC connectors are marked '1A', '1B' and '2A' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails.
FTA-E-01 data sheet
Figure 1 Mechanical layout
Version 2.0
page 9-1
Applications
The polarizing notches of the ELCO socket can be set to any of six positions per side (factory-set at position 4). Changing the polarization requires removal of the FTA from the DIN EN rail and the use of a polarizing tool, make ELCO (part no. 06 1989 02).
The ELCO socket has guide pins and socket gills to ensure correct alignment when mating.
For details on applications and connection options for the FTA-E-01 module refer to the 'SIC to FTA applications' data sheet.
page 9-2 Version 2.0
FTA-E-01 data sheet
Connections
The connections diagram of the FTA-E-01 module is as follows:
CONNECTIONS DIAGRAM FTA-E-01
SIC connector Field terminals
FTA-E-01 data sheet
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A3
B3
A2
B2
A5
B5
A4
B4
CH1
CH2
CH3
CH4
CH5
CH6
CH7 nc
A1 CH8
B1 +24 Vdc
0.25 AT
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
A3
B3
A2
B2
A5
B5
A4
B4
CH9
CH10
CH11
CH12
CH13
CH14
CH15 nc
A1 CH16
B1 +24 Vdc
0.25 AT
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
A5
B5
A4
B4
A3
B3
CH17
CH18
CH19
CH20
CH21
CH22
A2
B2
CH23 nc
A1 CH24
B1 +24 Vdc
0.25 AT nc = not connected j k l f h p r m n
W
X
Y
Z a b c d e
L
M
N
P
R
S
T
U
V
A
B
C
D
E
J
K
F
H
HH
JJ
KK
LL
MM
NN
BB
CC
DD
EE
FF u v w s t x y z
AA
IN 1+ (via fuse F1)
IN 1-
IN 2+ (via fuse F1)
IN 2-
IN 3+ (via fuse F1)
IN 3-
IN 4+ (via fuse F1)
IN 4-
IN 5+ (via fuse F1)
IN 5-
IN 6+ (via fuse F1)
IN 6-
IN 7+ (via fuse F1)
IN 7-
IN 8+ (via fuse F1)
IN 8-
IN 9+ (via fuse F2)
IN 9-
IN 10+ (via fuse F2)
IN 10-
Shield nc
IN 11+ (via fuse F2)
IN 11-
IN 12+ (via fuse F2)
IN 12-
IN 13+ (via fuse F2)
IN 13-
IN 14+ (via fuse F2)
IN 14-
IN 15+ (via fuse F2)
IN 15-
IN 16+ (via fuse F2)
IN 16-
IN 17+ (via fuse F3)
IN 17-
IN 18+ (via fuse F3)
IN 18-
IN 19+ (via fuse F3)
IN 19-
IN 20+ (via fuse F3)
IN 20-
IN 21+ (via fuse F3)
IN 21-
IN 22+ (via fuse F3) nc nc nc nc nc nc
IN 22-
IN 23+ (via fuse F3)
IN 23-
IN 24+ (via fuse F3)
IN 24-
Figure 2 Connections diagram
Version 2.0
page 9-3
Technical data
General
Power
Physical
Fuses
Termination
The FTA-E-01 module has the following specifications:
Type number:
Approvals:
FTA-E-01
CE, UL
Number of channels:
Maximum voltage:
24 (3 groups of 8)
36 Vac / 50 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
Module dimensions:
DIN EN rails:
Used rail length:
Rating:
Dimensions:
ELCO socket:
125 x 70 x 65 mm (L x W x H)
4.92 x 2.76 x 2.56 in (L x W x H)
TS32 / TS35 x 7.5
126 mm (4.96 in)
250 mAT (slow-acting)
5 x 20 mm (0.2 x 0.79 in) or
5 x 25 mm(0.2 x 0.98 in)
8016 series, 56 pins
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
page 9-4 Version 2.0
FTA-E-01 data sheet
FTA-E-02
Description
Fail-safe digital output FTA
(24/48/60 Vdc, 24 channels)
The field termination assembly module FTA-E-02 is the interface between the system interconnection cables (SIC) and the external field wiring (on E-56 ELCO).
Twenty-four channels (separated into six groups of four channels) can be connected to the FTA-E-02 module via system interconnection cables (SIC). These cables are plugged into the SIC connectors on the
FTA module. The six SIC connectors are marked '1A', '1B', '2A', '2B',
'3A' and '3B' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails.
Figure 1 Mechanical layout
FTA-E-02 data sheet Version 2.0
page 9-5
Applications
Connections diagrams
The polarizing notches of the ELCO socket can be set to any of six positions per side (factory-set at position 4). Changing the polarization requires removal of the FTA from the DIN EN rail and the use of a polarizing tool, make ELCO (part no. 06 1989 02).
The ELCO socket has guide pins and socket gills to ensure correct alignment when mating.
For details on applications and connection options for the FTA-E-02 module refer to the 'SIC to FTA applications' data sheet.
Figure 2 and Figure 3 on the next two pages show the connections diagrams of the FTA-E-02 module.
Figure 2 applies to configurations with one wire pair per channel (e.g.
10102/2/1, 10201/2/1, 10216/2/1 and 10205/2/1). Figure 3 applies to configurations with two wire pairs per channel (e.g. 10215/2/1).
page 9-6 Version 2.0
FTA-E-02 data sheet
Connections diagram
FTA-E-02 data sheet
SIC connector
CONNECTIONS DIAGRAM FTA-E-02
Field terminals
One wire pair per channel
2B
2B
2B
2B
2B
2B
2B
2B
2B
2B
3A
3A
3A
3A
3A
3A
3A
3A
3A
3A
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
A2
B2
A1
B1
A5
B5
A4
B4
A3
B3
CH17+
CH17-
CH18+
CH18-
CH19+
CH19-
CH20+
CH20nc nc
3B
3B
3B
3B
3B
3B
3B
3B
3B
3B nc = not connected
A3
B3
A2
B2
A1
B1
A5
B5
A4
B4
CH21+
CH21-
CH22+
CH22-
CH23+
CH23-
CH24+
CH24nc nc
CH13+
CH13-
CH14+
CH14-
CH15+
CH15-
CH16+
CH16nc nc
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
A3
B3
A2
B2
A5
B5
A4
B4
A1
B1
CH9+
CH9-
CH10+
CH10-
CH11+
CH11-
CH12+
CH12nc nc
CH1+
CH1-
CH2+
CH2-
CH3+
CH3-
CH4+
CH4nc nc
CH5+
CH5-
CH6+
CH6-
CH7+
CH7-
CH8+
CH8nc nc
Figure 2 Connections diagram (one wire pair per channel)
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 9a
OUT 9b
OUT 10a
OUT 10b
Shield nc
OUT 11a
OUT 11b
OUT 12a
OUT 12b
OUT 13a
OUT 13b
OUT 14a
OUT 14b
OUT 15a
OUT 15b
OUT 16a
OUT 16b
OUT 17a
OUT 17b
OUT 18a
OUT 18b
OUT 19a
OUT 19b
OUT 20a
OUT 20b
OUT 21a
OUT 21b
OUT 22a
OUT 22b
OUT 23a
OUT 23b nc nc nc
OUT 24a
OUT 24b nc nc nc
S
T
U
V
W
J
K
P
R
L
M
N
D
E
F
H
A
B
C m n p r h j k l e f a b c d
X
Y
Z
EE
FF
HH
JJ
KK
LL
MM
NN z
AA
BB
CC
DD u v w s t x y
Version 2.0
page 9-7
Connections diagram
page 9-8
SIC connector
CONNECTIONS DIAGRAM FTA-E-02
Field terminals
Two wire pairs per channel
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
A3
B3
A2
B2
A1
B1
A5
B5
A4
B4
CH3+
CH3-
CH3+
CH3-
CH4+
CH4-
CH4+
CH4nc nc
CH1+
CH1-
CH1+
CH1-
CH2+
CH2-
CH2+
CH2nc nc
2B
2B
2B
2B
2B
2B
2B
2B
2B
2B
3A
3A
3A
3A
3A
3A
3A
3A
3A
3A
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
B3
A2
B2
A1
B1
A5
B5
A4
B4
A3
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
CH9+
CH9-
CH9+
CH9-
CH10+
CH10-
CH10+
CH10nc nc
CH7+
CH7-
CH7+
CH7-
CH8+
CH8-
CH8+
CH8nc nc
CH5+
CH5-
CH5+
CH5-
CH6+
CH6-
CH6+
CH6nc nc
3B
3B
3B
3B
3B
3B
3B
3B
3B
3B nc = not connected
A3
B3
A2
B2
A5
B5
A4
B4
A1
B1
CH11+
CH11-
CH11+
CH11-
CH12+
CH12-
CH12+
CH12nc nc
Figure 3 Connections diagram (two wire pairs per channel)
OUT 1a
OUT 1b
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 5a
OUT 5b
Shield nc
OUT 6a
OUT 6b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 8a
OUT 8b
OUT 9a
OUT 9b
OUT 9a
OUT 9b
OUT 10a
OUT 10b nc nc nc nc
OUT 10a
OUT 10b
OUT 11a
OUT 11b
OUT 11a
OUT 11b
OUT 12a
OUT 12b
OUT 12a
OUT 12b nc nc
R
S
T
N
P
U
V
J
K
L
M
C
D
A
B
E
F
H e f h j b c d
W
X
Y
Z a
DD
EE
FF
HH
JJ w x y z
AA
BB
CC
KK
LL
MM
NN s t u v m n p r k l
Version 2.0
FTA-E-02 data sheet
Technical data
General
Power
Physical
Termination
The FTA-E-02 module has the following specifications:
Type number:
Approvals:
FTA-E-02
CE, UL
Number of channels:
Maximum voltage:
Maximum continuous current per channel:
24 (6 groups of 4)
36 Vac / 50 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
2 A
Module dimensions:
DIN EN rails:
Used rail length:
ELCO socket:
125 x 70 x 55 mm (L x W x H)
4.92 x 2.76 x 2.17 in (L x W x H)
TS32 / TS35 x 7.5
126 mm (4.96 in)
8016 series, 56 pins
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-E-02 data sheet Version 2.0
page 9-9
Left blank intentionally.
page 9-10 Version 2.0
FTA-E-02 data sheet
FTA-E-03
Description
Digital output FTA
(24 Vdc, 24 channels)
The field termination assembly module FTA-E-03 is the interface between the system interconnection cables (SIC) and the external field wiring (on E-56 ELCO).
Twenty-four channels (separated into three groups of eight channels with a common –) can be connected to the FTA-E-03 module via system interconnection cables (SIC). These cables are plugged into the
SIC connectors on the FTA module. The three SIC connectors are marked '1A', '1B' and '2A' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails.
FTA-E-03 data sheet
Figure 1 Mechanical layout
Version 2.0
page 9-11
Applications
Connections diagrams
The polarizing notches of the ELCO socket can be set to any of six positions per side (factory-set at position 4). Changing the polarization requires removal of the FTA from the DIN EN rail and the use of a polarizing tool, make ELCO (part no. 06 1989 02).
The ELCO socket has guide pins and socket gills to ensure correct alignment when mating.
For details on applications and connection options for the FTA-E-03 module refer to the 'SIC to FTA applications' data sheet.
Figure 2 and Figure 3 on the next two pages show the connections diagrams of the FTA-E-03 module.
Figure 2 shows the connections diagram for 16-channel digital output modules. Figure 3 is a connection example for the 12-channel digital output module 10206/2/1.
page 9-12 Version 2.0
FTA-E-03 data sheet
Connections diagram
SIC connector
CONNECTIONS DIAGRAM FTA-E-03
Field terminals
Digital output module (16 channels)
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
CH1
CH2
CH3
CH4
CH5
CH6
CH7 nc
CH8
0 Vdc
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
A2
B2
A1
B1
A5
B5
A4
B4
A3
B3
CH9
CH10
CH11
CH12
CH13
CH14
CH15 nc
CH16
0 Vdc
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
CH17
CH18
CH19
CH20
CH21
CH22
CH23 nc
CH24
0 Vdc nc = not connected nc nc nc
OUT 22a
OUT 22b
OUT 23a
OUT 23b
OUT 24a
OUT 24b nc nc nc
OUT 13a
OUT 13b
OUT 14a
OUT 14b
OUT 15a
OUT 15b
OUT 16a
OUT 16b
OUT 17a
OUT 17b
OUT 18a
OUT 18b
OUT 19a
OUT 19b
OUT 20a
OUT 20b
OUT 21a
OUT 21b
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 9a
OUT 9b
OUT 10a
OUT 10b
Shield nc
OUT 11a
OUT 11b
OUT 12a
OUT 12b
Figure 2 Connections diagram
(for 16-channel digital output modules)
EE
FF
HH
JJ
KK
AA
BB
CC
DD
LL
MM
NN u v w x y z s t p r m n k l h j e f a b
Y
Z
U
V
W
X c d
M
N
P
R
S
T
K
L
H
J
E
F
A
B
C
D
FTA-E-03 data sheet Version 2.0
page 9-13
Connections diagram
CONNECTIONS DIAGRAM FTA-E-03
SIC connector Field terminals
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A5
B3
A2
B2
A1
B1
B5
A4
B4
A3
CH1
CH2
CH3
CH4
CH5
CH6
CH7 nc
CH8
0 Vdc
Example for 12-channel digital output module
10206/2/1
A5
B3
A2
B2
A1
B1
B5
A4
B4
A3
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
CH9
CH10
CH11
CH12
0 Vdc
0 Vdc
0 Vdc nc
0 Vdc
0 Vdc
CH13
CH14
CH15
CH16
CH17
CH18
CH19 nc
CH20
0 Vdc
0 Vdc
0 Vdc
0 Vdc
0 Vdc
0 Vdc
OUT 13a
OUT 13b
OUT 14a
OUT 14b
OUT 15a
OUT 15b
OUT 16a
OUT 16b
OUT 17a
OUT 17b
OUT 18a
OUT 18b
OUT 19a
OUT 19b nc nc nc nc
OUT 20a
OUT 20b nc nc
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 9a
OUT 9b
OUT 10a
OUT 10b
Shield nc
OUT 11a
OUT 11b
OUT 12a
OUT 12b
0 Vdc
0 Vdc
0 Vdc
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a nc = not connected
Figure 3 Connections diagram
(example for 12-channel digital output module 10206/2/1) y z
AA
BB w x u v
CC
DD r s n p t j k l m
EE
FF
HH
JJ
KK
LL
MM
NN d e b c f h
Z a
X
Y
T
U
V
W
N
P
R
S
A
F
H
J
K
B
C
D
E
L
M page 9-14 Version 2.0
FTA-E-03 data sheet
Technical data
General
Power
Physical
Termination
The FTA-E-03 module has the following specifications:
Type number:
Approvals:
FTA-E-03
CE, UL
Number of channels:
Maximum voltage:
Maximum continuous current per channel:
24 (3 groups of 8)
36 Vac / 50 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
2 A
Module dimensions:
DIN EN rails:
Used rail length:
ELCO socket:
125 x 70 x 55 mm (L x W x H)
4.92 x 2.76 x 2.17 in (L x W x H)
TS32 / TS35 x 7.5
126 mm (4.96 in)
8016 series, 56 pins
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-E-03 data sheet Version 2.0
page 9-15
Left blank intentionally.
page 9-16 Version 2.0
FTA-E-03 data sheet
FTA-E-04
Description
Digital output (relay contact) FTA
(25 channels)
The field termination assembly module FTA-E-04 is the interface between the system interconnection cables (SIC) and the external field wiring (on E-56 ELCO).
Twenty-five channels (separated into five sets of five channels) can be connected to the FTA-E-04 module via system interconnection cables
(SIC). These cables are plugged into the SIC connectors on the FTA module. The five SIC connectors are marked '1A', '1B', '2A', '2B' and
'3A' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails.
Figure 1 Mechanical layout
FTA-E-04 data sheet Version 2.0
page 9-17
Applications
The polarizing notches of the ELCO socket can be set to any of six positions per side (factory-set at position 4). Changing the polarization requires removal of the FTA from the DIN EN rail and the use of a polarizing tool, make ELCO (part no. 06 1989 02).
The ELCO socket has guide pins and socket gills to ensure correct alignment when mating.
For details on applications and connection options for the FTA-E-04 module refer to the 'SIC to FTA applications' data sheet.
page 9-18 Version 2.0
FTA-E-04 data sheet
Connections diagram
SIC connector
CONNECTIONS DIAGRAM FTA-E-04
Field terminals
FTA-E-04 data sheet
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A5 CH1 c
B5 CH1 no
A4 CH2 c
B4 CH2 no
A3 CH3 c
B3 CH3 no
A2 CH4 c
B2 CH4 no
A1 CH5 c
B1 CH5 no
A5 CH6 c
B5 CH6 no
A4 CH7 c
B4 CH7 no
A3 CH8 c
B3 CH8 no
A2 CH9 c
B2 CH9 no
A1 CH10 c
B1 CH10 no
A5 CH11 c
B5 CH11 no
A4 CH12 c
B4 CH12 no
A3 CH13 c
B3 CH13 no
A2 CH14 c
B2 CH14 no
A1 CH15 c
B1 CH15 no
A5 CH16 c
B5 CH16 no
A4 CH17 c
B4 CH17 no
A3 CH18 c
B3 CH18 no
A2 CH19 c
B2 CH19 no
A1 CH20 c
B1 CH20 no
A5 CH21 c
B5 CH21 no
A4 CH22 c
B4 CH22 no
A3 CH23 c
B3 CH23 no
A2 CH24 c
B2 CH24 no
A1 CH25 c
B1 CH25 no
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
2B
2B
2B
2B
2B
2B
2B
2B
2B
2B
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
3A
3A
3A
3A
3A
3A
3A
3A
3A
3A nc = not connected
Figure 2 Connections diagram
OUT 14b
OUT 15a
OUT 15b
OUT 16a
OUT 16b
OUT 17a
OUT 17b
OUT 18a
OUT 18b
OUT 19a
OUT 19b
OUT 20a
OUT 20b
OUT 21a
OUT 21b
OUT 22a
OUT 22b
OUT 23a
OUT 23b nc nc nc nc
OUT 24a
OUT 24b
OUT 25a
OUT 25b
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 9a
OUT 9b
OUT 10a
OUT 10b
Shield nc
OUT 11a
OUT 11b
OUT 12a
OUT 12b
OUT 13a
OUT 13b
OUT 14a
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a y z
AA
BB w x u v
CC
DD r s n p t j k l m
EE
FF
HH
JJ
KK
LL
MM
NN d e b c f h
Z a
X
Y
T
U
V
W
N
P
R
S
A
F
H
J
K
B
C
D
E
L
M
Version 2.0
page 9-19
Technical data
General
Power
Physical
Termination
The FTA-E-04 module has the following specifications:
Type number:
Approvals:
FTA-E-04
CE, UL
Number of channels:
Maximum voltage:
Maximum continuous current per channel:
25 (5 groups of 5)
36 Vac / 50 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
2 A
Module dimensions:
DIN EN rails:
Used rail length:
ELCO socket:
125 x 70 x 55 mm (L x W x H)
4.92 x 2.76 x 2.17 in (L x W x H)
TS32 / TS35 x 7.5
126 mm (4.96 in)
8016 series, 56 pins
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
page 9-20 Version 2.0
FTA-E-04 data sheet
FTA-E-05
Description
Active digital output (relay) FTA
(25 channels)
The field termination assembly module FTA-E-05 is the interface between the system interconnection cables (SIC) and the external field wiring (on E-56 ELCO).
Twenty-five potential-free relay contact output channels (separated into five groups of five channels) can be connected to the FTA-E-05 module via system interconnection cables (SIC). These cables are plugged into the SIC connectors on the FTA module. The five SIC connectors are marked '1A', '1B', '2A', '2B' and '3A' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails.
FTA-E-05 data sheet
Figure 1 Mechanical layout
Version 2.0
page 9-21
Each group has a fuse (2 A) and a screw terminal pair for external power. This way the potential-free relay contacts of 10208/2/1 modules can be used as powering outputs to the field.
The polarizing notches of the ELCO socket can be set to any of six positions per side (factory-set at position 4). Changing the polarization requires removal of the FTA from the DIN EN rail and the use of a polarizing tool, make ELCO (part no. 06 1989 02).
The ELCO socket has guide pins and socket gills to ensure correct alignment when mating.
Applications
Figure 2 Schematic diagram of one group
For details on applications and connection options for the FTA-E-05 module refer to the 'SIC to FTA applications' data sheet.
page 9-22 Version 2.0
FTA-E-05 data sheet
Connections diagram
FTA-E-05 data sheet
SIC connector
CONNECTIONS DIAGRAM FTA-E-05
Field terminals
X3
X3
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
X4
X4
X2
X2
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
X5
X5
2B
2B
2B
2B
2B
2B
2B
2B
2B
2B
X6
X6
A5 CH16 c
B5 CH16 no
A4 CH17 c
B4 CH17 no
A3 CH18 c
B3 CH18 no
A2 CH19 c
B2 CH19 no
A1 CH20 c
B1 CH20 no
2 AT
1 + Vext
2 - Vext
3A
3A
3A
3A
3A
A5 CH21 c
B5 CH21 no
A4 CH22 c
B4 CH22 no
A3 CH23 c
3A
3A
3A
3A
B3
A2
B2
A1
CH23 no
CH24 c
CH24 no
CH25 c
3A B1 CH25 no no = normally open
2 AT
1 + Vext
2 - Vext
A5 CH1 c
B5 CH1 no
A4 CH2 c
B4 CH2 no
A3 CH3 c
B3 CH3 no
A2 CH4 c
B2 CH4 no
A1 CH5 c
B1 CH5 no
2 AT
1 + Vext
2 - Vext
A5 CH6 c
B5 CH6 no
A4 CH7 c
B4 CH7 no
A3 CH8 c
B3 CH8 no
A2 CH9 c
B2 CH9 no
A1 CH10 c
B1 CH10 no
2 AT
1 + Vext
2 - Vext
A5 CH11 c
B5 CH11 no
A4 CH12 c
B4 CH12 no
A3 CH13 c
B3 CH13 no
A2 CH14 c
B2 CH14 no
A1 CH15 c
B1 CH15 no
2 AT
1 + Vext
2 - Vext nc = not connected
Figure 3 Connections diagram
OUT 12b
OUT 13a
OUT 13b
OUT 14a
OUT 14b
OUT 15a
OUT 15b
OUT 16a
OUT 16b
OUT 17a
OUT 17b
OUT 18a
OUT 18b
OUT 19a
OUT 19b
OUT 20a
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 9a
OUT 9b
OUT 10a
OUT 10b
Shield nc
OUT 11a
OUT 11b
OUT 12a
OUT 20b
OUT 21a
OUT 21b
OUT 22a
OUT 22b
OUT 23a
OUT 23b
OUT 24a
OUT 24b
OUT 25a
OUT 25b nc nc nc nc u v w t s m n p r k l h j d e f
T
U
V
W
N
P
R
S
X
Y
Z a b c
E
F
H
J
K
L
M
A
B
C
D
BB
CC
DD
EE x y z
AA
FF
HH
JJ
KK
LL
MM
NN
Version 2.0
page 9-23
Technical data
General
Power
Fuses
Physical
Termination
The FTA-E-05 module has the following specifications:
Type number:
Approvals:
FTA-E-05
CE, UL
Number of channels:
Maximum voltage:
25 (5 groups of 5)
30 Vac / 36 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
Rating:
Dimensions:
Module dimensions:
DIN EN rails:
Used rail length:
ELCO socket:
2 AT (slow-acting)
5 x 20 mm (0.2 x 0.79 in) or
5 x 25 mm(0.2 x 0.98 in)
155 x 70 x 65 mm (L x W x H)
6.10 x 2.76 x 2.56 in (L x W x H)
TS32 / TS35 x 7.5
156 mm (6.14 in)
8016 series, 56 pins
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
page 9-24 Version 2.0
FTA-E-05 data sheet
FTA-T-01
Description
Fail-safe digital input FTA
(24/48/60 Vdc, 24 channels)
The field termination assembly module FTA-T-01 is the interface between the system interconnection cables (SICs) and the external field wiring (screw terminals).
Twenty-four channels (separated into three groups of eight channels with a 250 mA fuse in the common +) can be connected to the
FTA-T-01 module via system interconnection cables (SIC). These cables are plugged into the SIC connectors on the FTA module. The three SIC connectors are marked '1A', '1B' and '2A' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Applications
FTA-T-01 data sheet
Figure 1 Mechanical layout
For details on applications and connection options for the FTA-T-01 module refer to the 'SIC to FTA applications' data sheet.
Version 2.0
page 9-25
Connections
The connections diagram of the FTA-T-01 module is as follows:
CONNECTIONS DIAGRAM FTA-T-01
SIC connector Field terminals
page 9-26
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A3
B3
A2
B2
A5
B5
A4
B4
CH1
CH2
CH3
CH4
CH5
CH6
CH7 nc
A1 CH8
B1 +24 Vdc
0.25 AT
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
A3
B3
A2
B2
A5
B5
A4
B4
CH9
CH10
CH11
CH12
CH13
CH14
CH15 nc
A1 CH16
B1 +24 Vdc
0.25 AT
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
A5
B5
A4
B4
CH17
CH18
CH19
CH20
A3
B3
A2
B2
CH21
CH22
CH23 nc
A1 CH24
B1 +24 Vdc
0.25 AT nc = not connected
Figure 2 Connections diagram
38
39
40
41
34
35
36
37
30
31
32
33
26
27
28
29
48
49
50
42
43
44
45
46
47
22
23
24
25
18
19
20
21
14
15
16
17
10
11
12
13
7
8
9
5
6
3
4
1
2
IN 13-
IN 14+ (via fuse F2)
IN 14-
IN 15+ (via fuse F2)
IN 15-
IN 16+ (via fuse F2)
IN 16-
IN 17+ (via fuse F3)
IN 17-
IN 18+ (via fuse F3)
IN 18-
IN 19+ (via fuse F3)
IN 19-
IN 20+ (via fuse F3)
IN 20-
IN 21+ (via fuse F3)
IN 21-
IN 22+ (via fuse F3)
IN 22-
IN 23+ (via fuse F3)
IN 23-
IN 24+ (via fuse F3)
IN 24-
Shield
Shield
IN 1+ (via fuse F1)
IN 1-
IN 2+ (via fuse F1)
IN 2-
IN 3+ (via fuse F1)
IN 3-
IN 4+ (via fuse F1)
IN 4-
IN 5+ (via fuse F1)
IN 5-
IN 6+ (via fuse F1)
IN 6-
IN 7+ (via fuse F1)
IN 7-
IN 8+ (via fuse F1)
IN 8-
IN 9+ (via fuse F2)
IN 9-
IN 10+ (via fuse F2)
IN 10-
IN 11+ (via fuse F2)
IN 11-
IN 12+ (via fuse F2)
IN 12-
IN 13+ (via fuse F2)
Version 2.0
FTA-T-01 data sheet
Technical data
General
Power
Physical
Fuse
Termination
The FTA-T-01 module has the following specifications:
Type number:
Approvals:
FTA-T-01
CE, UL
Number of channels:
Maximum voltage:
24 (3 groups of 8)
36 Vac / 50 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
Module dimensions:
DIN EN rails:
Used rail length:
Rating:
Dimensions:
145 x 70 x 65 mm (L x W x H)
5.71 x 2.76 x 2.56 in (L x W x H)
TS32 / TS35 x 7.5
146 mm (5.75 in)
250 mAT (slow-acting)
5 x 20 mm (0.2 x 0.79 in) or
5 x 25 mm(0.2 x 0.98 in)
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-01 data sheet Version 2.0
page 9-27
Left blank intentionally.
page 9-28 Version 2.0
FTA-T-01 data sheet
FTA-T-02
Description
Fail-safe digital output FTA
(24/48/60 Vdc, 24 channels)
The field termination assembly module FTA-T-02 is the interface between the system interconnection cables (SICs) and the external field wiring (screw terminals).
Twenty-four channels (separated into six groups of four channels) can be connected to the FTA-T-02 module via system interconnection cables (SIC). These cables are plugged into the SIC connectors on the
FTA module. The six SIC connectors are marked '1A', '1B', '2A', '2B',
'3A' and '3B' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Applications
FTA-T-02 data sheet
Figure 1 Mechanical layout
For details on applications and connection options for the FTA-T-02 module refer to the 'SIC to FTA applications' data sheet.
Version 2.0
page 9-29
Connections
page 9-30
The connections diagram of the FTA-T-02 module is as follows:
CONNECTIONS DIAGRAM FTA-T-02
SIC connector Field terminals
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
2B
2B
2B
2B
2B
2B
2B
2B
2B
2B
3A
3A
3A
3A
3A
3A
3A
3A
3A
3A
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
3B
3B
3B
3B
3B
3B
3B
3B
3B
3B nc = not connected
A5 CH21+
B5 CH21-
A4 CH22+
B4 CH22-
A3 CH23+
B3 CH23-
A2 CH24+
B2 CH24-
A1
B1 nc nc
A5 CH13+
B5 CH13-
A4 CH14+
B4 CH14-
A3 CH15+
B3 CH15-
A2 CH16+
B2 CH16-
A1 nc
B1 nc
A5 CH17+
B5 CH17-
A4 CH18+
B4 CH18-
A3 CH19+
B3 CH19-
A2 CH20+
B2 CH20-
A1
B1 nc nc
A5
B5
CH9+
CH9-
A4 CH10+
B4 CH10-
A3 CH11+
B3 CH11-
A2 CH12+
B2
A1
B1
CH12nc nc
CH5+
CH5-
CH6+
CH6-
CH7+
CH7-
CH8+
CH8nc nc
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
CH1+
CH1-
CH2+
CH2-
CH3+
CH3-
CH4+
CH4nc nc
Figure 2 Connections diagram
OUT 19a
OUT 19b
OUT 20a
OUT 20b
OUT 21a
OUT 21b
OUT 22a
OUT 22b
OUT 23a
OUT 23b
OUT 24a
OUT 24b
Shield
Shield
OUT 12b
OUT 13a
OUT 13b
OUT 14a
OUT 14b
OUT 15a
OUT 15b
OUT 16a
OUT 16b
OUT 17a
OUT 17b
OUT 18a
OUT 18b
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 9a
OUT 9b
OUT 10a
OUT 10b
OUT 11a
OUT 11b
OUT 12a
Version 2.0
FTA-T-02 data sheet
45
46
47
48
49
50
41
42
43
44
37
38
39
40
28
29
30
31
24
25
26
27
32
33
34
35
36
17
18
19
20
21
22
23
13
14
15
16
9
10
11
12
6
7
8
4
5
1
2
3
Technical data
General
Power
Physical
Termination
The FTA-T-02 module has the following specifications:
Type number:
Approvals:
FTA-T-02
CE, UL
Number of channels:
Maximum voltage:
Maximum continuous current per channel:
24 (6 groups of 4)
36 Vac / 50 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
2 A
Module dimensions:
DIN EN rails:
Used rail length:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
145 x 70 x 57 mm (L x W x H)
5.71 x 2.76 x 2.24 in (L x W x H)
TS32 / TS35 x 7.5
146 mm (5.75 in)
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-02 data sheet Version 2.0
page 9-31
Left blank intentionally.
page 9-32 Version 2.0
FTA-T-02 data sheet
FTA-T-03
Description
Digital output FTA
(24 Vdc, 24 channels)
The field termination assembly module FTA-T-03 is the interface between the system interconnection cables (SICs) and the external field wiring (screw terminals).
Twenty-four channels (separated into three groups of eight channels with a common –) can be connected to the FTA-T-03 module via system interconnection cables (SIC). These cables are plugged into the
SIC connectors on the FTA module. The three SIC connectors are marked '1A', '1B' and '2A' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Figure 1 Mechanical layout
FTA-T-03 data sheet Version 2.0
page 9-33
Applications
Connections diagrams
For details on applications and connection options for the FTA-T-03 module refer to the 'SIC to FTA applications' data sheet.
Figure 2 and Figure 3 on the next two pages show the connections diagrams of the FTA-T-03 module.
Figure 2 shows the connections diagram for 16-channel digital output modules. Figure 3 is a connection example for the 12-channel digital output module 10206/2/1.
page 9-34 Version 2.0
FTA-T-03 data sheet
Connections diagram
SIC connector
CONNECTIONS DIAGRAM FTA-T-03
Field terminals
Digital output module (16 channels)
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A5
B5
A4
B4
A3
B3
CH1
CH2
CH3
CH4
CH5
CH6
A2
B2
CH7 nc
A1 CH8
B1 0 Vdc
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
A5
B5
A4
B4
A3
B3
A2
B2
CH9
CH10
CH11
CH12
CH13
CH14
CH15 nc
A1 CH16
B1 0 Vdc
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
A5
B5
A4
B4
A3
B3
CH17
CH18
CH19
CH20
CH21
CH22
A2
B2
CH23 nc
A1 CH24
B1 0 Vdc nc = not connected
OUT 8a
OUT 8b
OUT 9a
OUT 9b
OUT 10a
OUT 10b
OUT 11a
OUT 11b
OUT 12a
OUT 12b
OUT 13a
OUT 13b
OUT 14a
OUT 14b
OUT 15a
OUT 15b
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 16a
OUT 16b
OUT 17a
OUT 17b
OUT 18a
OUT 18b
OUT 19a
OUT 19b
OUT 20a
OUT 20b
OUT 21a
OUT 21b
OUT 22a
OUT 22b
OUT 23a
OUT 23b
OUT 24a
OUT 24b
Shield
Shield
Figure 2 Connections diagram
(for 16-channel digital output modules)
24
25
26
27
28
29
30
19
20
21
22
23
15
16
17
18
7
8
9
10
11
12
13
14
5
6
3
4
1
2
43
44
45
46
47
39
40
41
42
31
32
33
34
35
36
37
38
48
49
50
FTA-T-03 data sheet Version 2.0
page 9-35
Connections diagram
CONNECTIONS DIAGRAM FTA-T-03
SIC connector Field terminals
Example for 12-channel digital output module
(10206/2/1)
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A3
B3
A2
B2
A5
B5
A4
B4
A1
B1
CH1
CH2
CH3
CH4
CH5
CH6
CH7 nc
CH8
0 Vdc
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
CH9
CH10
CH11
CH12
0 Vdc
0 Vdc
0 Vdc nc
0 Vdc
0 Vdc
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
A3
B3
A2
B2
A5
B5
A4
B4
A1
B1
CH13
CH14
CH15
CH16
CH17
CH18
CH19 nc
CH20
0 Vdc
0 Vdc
0 Vdc
0 Vdc
0 Vdc
0 Vdc
0 Vdc
0 Vdc
0 Vdc
OUT 9a
OUT 9b
OUT 10a
OUT 10b
OUT 11a
OUT 11b
OUT 12a
OUT 12b
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 13a
OUT 13b
OUT 14a
OUT 14b
OUT 15a
OUT 15b
OUT 16a
OUT 16b
OUT 17a
OUT 17b
OUT 18a
OUT 18b
OUT 19a
OUT 19b
OUT 20a
OUT 20b
Shield
Shield nc = not connected
Figure 3 Connections diagram
(example for 12-channel digital output module 10206/2/1)
29
30
31
32
25
26
27
28
21
22
23
24
17
18
19
20
13
14
15
16
9
10
11
12
7
8
5
6
3
4
1
2
45
46
47
48
41
42
43
44
49
50
37
38
39
40
33
34
35
36 page 9-36 Version 2.0
FTA-T-03 data sheet
Technical data
General
Power
Physical
Termination
The FTA-T-03 module has the following specifications:
Type number:
Approvals:
FTA-T-03
CE, UL
Number of channels:
Maximum voltage:
Maximum continuous current per channel:
24 (3 groups of 8)
36 Vac / 50 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
2 A
Module dimensions:
DIN EN rails:
Used rail length:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
145 x 70 x 57 mm (L x W x H)
5.71 x 2.76 x 2.24 in (L x W x H)
TS32 / TS35 x 7.5
146 mm (5.75 in)
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-03 data sheet Version 2.0
page 9-37
Left blank intentionally.
page 9-38 Version 2.0
FTA-T-03 data sheet
FTA-T-04
Description
Digital output (relay contact) FTA
(25 channels)
The field termination assembly module FTA-T-04 is the interface between the system interconnection cables (SICs) and the external field wiring (screw terminals).
Twenty-five channels (separated into five groups of five channels) can be connected to the FTA-T-04 module via system interconnection cables (SIC). These cables are plugged into the SIC connectors on the
FTA module. The five SIC connectors are marked '1A', '1B', '2A', '2B' and '3A' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Applications
Figure 1 Mechanical layout
For details on applications and connection options for the FTA-T-04 module refer to the 'SIC to FTA applications' data sheet.
FTA-T-04 data sheet Version 2.0
page 9-39
Connections
The connections diagram of the FTA-T-04 module is as follows:
CONNECTIONS DIAGRAM FTA-T-04
SIC connector Field terminals
page 9-40
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A5 CH1 c
B5 CH1 no
A4 CH2 c
B4 CH2 no
A3 CH3 c
B3 CH3 no
A2 CH4 c
B2 CH4 no
A1
B1
CH5 c
CH5 no
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
A5 CH6 c
B5 CH6 no
A4 CH7 c
B4 CH7 no
A3 CH8 c
B3 CH8 no
A2 CH9 c
B2 CH9 no
A1 CH10 c
B1 CH10 no
A5 CH11 c
B5 CH11 no
A4 CH12 c
B4 CH12 no
A3 CH13 c
B3 CH13 no
A2 CH14 c
B2 CH14 no
A1 CH15 c
B1 CH15 no
2B
2B
2B
2B
2B
2B
2B
2B
2B
2B
A5 CH16 c
B5 CH16 no
A4 CH17 c
B4 CH17 no
A3 CH18 c
B3 CH18 no
A2 CH19 c
B2 CH19 no
A1 CH20 c
B1 CH20 no
3A
3A
3A
3A
3A
3A
3A
3A
3A
3A
A5 CH21 c
B5 CH21 no
A4 CH22 c
B4 CH22 no
A3 CH23 c
B3 CH23 no
A2 CH24 c
B2 CH24 no
A1 CH25 c
B1 CH25 no
Figure 2 Connections diagram
OUT 9a
OUT 9b
OUT 10a
OUT 10b
OUT 11a
OUT 11b
OUT 12a
OUT 12b
OUT 13a
OUT 13b
OUT 14a
OUT 14b
OUT 15a
OUT 15b
OUT 16a
OUT 16b
OUT 17a
OUT 17b
OUT 18a
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 18b
OUT 19a
OUT 19b
OUT 20a
OUT 20b
OUT 21a
OUT 21b
OUT 22a
OUT 22b
OUT 23a
OUT 23b
OUT 24a
OUT 24b
OUT 25a
OUT 25b
Version 2.0
FTA-T-04 data sheet
31
32
33
34
35
27
28
29
30
21
22
23
24
17
18
19
20
25
26
11
12
13
14
7
8
9
10
15
16
3
4
1
2
5
6
40
41
42
43
36
37
38
39
44
45
46
47
48
49
50
Technical data
General
Power
Physical
Termination
The FTA-T-04 module has the following specifications:
Type number:
Approvals:
FTA-T-04
CE, UL
Number of channels:
Maximum voltage:
Maximum continuous current per channel:
25 (5 groups of 5)
36 Vac / 50 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
2 A
Module dimensions:
DIN EN rails:
Used rail length:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
145 x 70 x 57 mm (L x W x H)
5.71 x 2.76 x 2.24 in (L x W x H)
TS32 / TS35 x 7.5
146 mm (5.75 in)
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-04 data sheet Version 2.0
page 9-41
Left blank intentionally.
page 9-42 Version 2.0
FTA-T-04 data sheet
FTA-T-05
Description
Fail-safe digital output FTA
(24 Vdc, 12 channels)
The field termination assembly module FTA-T-05 is the interface between the system interconnection cables (SICs) and the external field wiring (screw terminals).
Twelve channels (separated into six groups of two channels) can be connected to the FTA-T-05 module via system interconnection cables
(SIC). These cables are plugged into the SIC connectors on the FTA module. The six SIC connectors are marked '1A', '1B', '2A', '2B', '3A' and '3B' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Applications
Figure 1 Mechanical layout
For details on applications and connection options for the FTA-T-05 module refer to the 'SIC to FTA applications' data sheet.
FTA-T-05 data sheet Version 2.0
page 9-43
Connections
page 9-44
The connections diagram of the FTA-T-05 module is as follows:
CONNECTIONS DIAGRAM FTA-T-05
SIC connector Field terminals
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
2B
2B
2B
2B
2B
2B
2B
2B
2B
2B
3A
3A
3A
3A
3A
3A
3A
3A
3A
3A
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
A3
B3
A2
B2
A1
B1
A5
B5
A4
B4
A5
B5
A4
B4
CH9+
CH9-
CH9+
CH9-
A3 CH10+
B3 CH10-
A2 CH10+
B2 CH10-
A1
B1 nc nc
CH7+
CH7-
CH7+
CH7-
CH8+
CH8-
CH8+
CH8nc nc
3B
3B
3B
3B
3B
3B
3B
3B
3B
3B nc = not connected
A5 CH11+
B5 CH11-
A4 CH11+
B4 CH11-
A3 CH12+
B3 CH12-
A2 CH12+
B2 CH12-
A1
B1 nc nc
CH5+
CH5-
CH5+
CH5-
CH6+
CH6-
CH6+
CH6nc nc
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
CH1+
CH1-
CH1+
CH1-
CH2+
CH2-
CH2+
CH2nc nc
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
CH3+
CH3-
CH3+
CH3-
CH4+
CH4-
CH4+
CH4nc nc
Figure 2 Connections diagram
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
OUT 9a
OUT 9b
OUT 10a
OUT 10b
OUT 11a
OUT 11b
OUT 12a
OUT 12b
Shield
Version 2.0
FTA-T-05 data sheet
16
17
18
19
12
13
14
15
20
21
22
23
24
25
7
8
5
6
9
10
11
3
4
1
2
Technical data
General
Power
Physical
Termination
The FTA-T-05 module has the following specifications:
Type number:
Approvals:
FTA-T-05
CE, UL
Number of channels:
Maximum voltage:
Maximum continuous current per channel:
12 (6 groups of 2)
36 Vac / 50 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
125 Vac / 150 Vdc – IEC 1010 (1990), overvoltage category 2 (Table D.10)
3 A
Module dimensions:
DIN EN rails:
Used rail length:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
145 x 70 x 48 mm (L x W x H)
5.71 x 2.76 x 1.89 in (L x W x H)
TS32 / TS35 x 7.5
146 mm (5.75 in)
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-05 data sheet Version 2.0
page 9-45
Left blank intentionally.
page 9-46 Version 2.0
FTA-T-05 data sheet
FTA-T-06
Description
Fail-safe active digital input FTA
(115 Vac, 8 channels)
The field termination assembly module FTA-T-06 is an eight-channel fail-safe 115 Vac input converter module which supplies the AC voltage to the field contacts (potential-free). The module has one pair of terminals to connect the external excitation voltage for all eight channels.
Each channel converts a 115 Vac input signal to a 24 Vdc input signal which can be connected to the 24 Vdc fail-safe input module
10101/2/1, thus creating a fail-safe 115 Vac input for the FSC system.
Eight channels can be connected to the FTA-T-06 module via a system interconnection cable (SIC). This cable is plugged into the SIC connector on the FTA module. The SIC connector is marked '1A'
(white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
FTA-T-06 data sheet
Figure 1 Mechanical layout
Version 2.0
page 9-47
Figure 2 Schematic diagram
Applications
For details on applications and connection options for the FTA-T-06 module refer to the 'SIC to FTA applications' data sheet.
Field cable lengths
High-impedance AC inputs – like the inputs on this FTA – have a limited capability of handling the wire capacitance of standard multicore field cables. The wire capacitance of the field cable acts as a shunt impedance over the field contact (see Figure 3).
page 9-48
Figure 3 Standard (multicore) field cable
Version 2.0
FTA-T-06 data sheet
FTA-T-06 data sheet
When the current through this shunt impedance exceeds the maximum
'LOW' current, the input may be activated by this shunt impedance, thus disabling the input function (by keeping the input activated continuously, i.e. ON). Every AC input will have a maximum 'LOW' current that it can handle.
The maximum allowable cable length depends on the maximum
'LOW' current (e.g. 1.0 mA), the typical cable capacitance (e.g.
120 pF/m), the maximum supply voltage (e.g. 130 Vac) and the supply frequency (e.g. 60 Hz).
The maximum length (in meters) can be calculated using the following formula:
L max
=
I low
V max
2 f C where:
I
L max
= maximum allowable cable length low
= maximum 'LOW' current f
V max
= maximum supply voltage
= supply frequency
C typ
= typical cable capacitance
As an example, we will calculate the maximum field cable length (in meters) using the values mentioned above:
L max
=
∗
∗ ∗ ∗ ∗ ∗
-12
)
=
170 m
In this example, the maximum allowable field cable length is 170 meters (186 yards).
Solutions:
The field cable length limit can be eliminated by using field cables with wires that are shielded separately (see Figure 4).
The only (relevant) capacitance of the input wire is to the shield
(0 Vac or earth) and this will not activate a 'LOW' input.
In case of shielded wire pairs, the second wire of the pair must be:
1. left unconnected, or
2. connected to the same input signal, or
3. connected to 0 Vac.
The 115 Vac wire can be used for more than one input.
Version 2.0
page 9-49
Connections
Figure 4 Field cable with separately shielded wires
In practice, a mix of wiring methods may be used. For example, use a cable with shielded wires between the control cabinet and a distribution box close to the process. This cable may be long, e.g.
3 km (1.8 mi). Then use a standard (multicore) cable for the connection between the distribution box and the field contact. This cable length is limited to the value calculated using the formula mentioned above.
The connections diagram of the FTA-T-06 module is as follows:
CONNECTIONS DIAGRAM FTA-T-06
SIC connector Field terminals
page 9-50
1
1
1
1
1
1
1
1
1
1
B3
A2
B2
A1
B1
A5
B5
A4
B4
A3
CH1
CH2
CH3
CH4
CH5
CH6
CH7
0 Vdc
CH8 nc nc = not connected
Figure 5 Connections diagram
IN 1a
IN 1b
IN 2a
IN 2b
IN 3a
IN 3b
IN 4a
IN 4b
IN 5a
IN 5b
IN 6a
IN 6b
IN 7a
IN 7b
IN 8a
IN 8b
COMMON 115 Vac
COMMON 0 Vac
13
14
15
16
9
10
11
12
17
18
7
8
5
6
3
4
1
2
Version 2.0
FTA-T-06 data sheet
Technical data
General
Input
Physical
Termination
The FTA-T-06 module has the following specifications:
Type number:
Approvals:
FTA-T-06
CE, TÜV, UL
Number of input channels: 8
Input voltage:
115 Vac,
±
15%
Input frequency: 50-60 Hz
Input current:
Input LOW:
< 16 mA at 115 Vac
I
≤
1 mA (see 'Field cable length'
section in this data sheet)
Module dimensions:
DIN EN rails:
Used rail length:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
195 x 70 x 48 mm (L x W x H)
7.68 x 2.76 x 1.89 in (L x W x H)
TS32 / TS35 x 7.5
196 mm (7.72 in)
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-06 data sheet Version 2.0
page 9-51
Left blank intentionally.
page 9-52 Version 2.0
FTA-T-06 data sheet
FTA-T-07
Description
Fail-safe passive digital input FTA
(115 Vac, 8 channels)
The field termination assembly module FTA-T-07 is an eight-channel fail-safe 115 Vac input converter module.
Each channel converts an externally supplied 115 Vac input signal to a
24 Vdc input signal which can be connected to the 24 Vdc fail-safe input module 10101/2/1, thus creating a fail-safe 115 Vac input for the
FSC system.
Eight channels can be connected to the FTA-T-07 module via a system interconnection cable (SIC). This cable is plugged into the SIC connector on the FTA module. The SIC connector is marked '1A'
(white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Figure 1 Mechanical layout
FTA-T-07 data sheet Version 2.0
page 9-53
Figure 2 Schematic diagram
Applications
For details on applications and connection options for the FTA-T-07 module refer to the 'SIC to FTA applications' data sheet.
Field cable lengths
High-impedance AC inputs – like the inputs on this FTA – have a limited capability of handling the wire capacitance of standard multicore field cables. The wire capacitance of the field cable acts as a shunt impedance over the field contact (see Figure 3).
page 9-54
Figure 3 Standard (multicore) field cable
Version 2.0
FTA-T-07 data sheet
FTA-T-07 data sheet
When the current through this shunt impedance exceeds the maximum
'LOW' current, the input may be activated by this shunt impedance, thus disabling the input function (by keeping the input activated continuously, i.e. ON). Every AC input will have a maximum 'LOW' current that it can handle.
The maximum allowable cable length depends on the maximum
'LOW' current (e.g. 1.0 mA), the typical cable capacitance (e.g.
120 pF/m), the maximum supply voltage (e.g. 130 Vac) and the supply frequency (e.g. 60 Hz).
The maximum length (in meters) can be calculated using the following formula:
L max
=
I low
V max
2 f C where:
I
L max
= maximum allowable cable length low
= maximum 'LOW' current f
V max
= maximum supply voltage
= supply frequency
C typ
= typical cable capacitance
As an example, we will calculate the maximum field cable length (in meters) using the values mentioned above:
L max
=
∗
∗ ∗ ∗ ∗ ∗
-12
)
=
170 m
In this example, the maximum allowable field cable length is 170 meters (186 yards).
Solutions:
The field cable length limit can be eliminated by using field cables with wires that are shielded separately (see Figure 4).
The only (relevant) capacitance of the input wire is to the shield
(0 Vac or earth) and this will not activate a 'LOW' input.
However, this type of cable is rather unusual. Field cables with shielded wire pairs are more commonly used. This allows for two connections methods:
1. Use the method of Figure 4 and leave the second wire of each pair unconnected, or
2. Connect the second wire of each pair to 0 Vac (see Figure 5). The
115 Vac / 0 Vac supply pair can be used for more than one input.
Version 2.0
page 9-55
Figure 4 Field cable with separately shielded wires
Figure 5 Field cable with shielded pairs
In practice, a mix of wiring methods may be used. For example, use a cable with shielded pairs between the control cabinet and a distribution box close to the process. This cable may be long, e.g.
3 km (1.8 mi). Then use a standard (multicore) cable for the connection between the distribution box and the field contact. This cable length is limited to the value calculated using the formula mentioned above.
page 9-56 Version 2.0
FTA-T-07 data sheet
Connections
The connections diagram of the FTA-T-07 module is as follows:
CONNECTIONS DIAGRAM FTA-T-07
SIC connector Field terminals
1
1
1
1
1
1
1
1
1
1
A5
B5
A4
B4
A3
B3
CH1
CH2
CH3
CH4
CH5
CH6
A2 CH7
B2 0 Vdc
A1
B1
CH8 nc nc = not connected
IN 5a
IN 5b
IN 6a
IN 6b
IN 7a
IN 7b
IN 8a
IN 8b
IN 1a
IN 1b
IN 2a
IN 2b
IN 3a
IN 3b
IN 4a
IN 4b
Figure 6 Connections diagram
9
10
11
12
13
14
15
16
6
7
8
3
4
1
2
5
FTA-T-07 data sheet Version 2.0
page 9-57
Technical data
General
Input
Physical
Termination
The FTA-T-07 module has the following specifications:
Type number:
Approvals:
FTA-T-07
CE, TÜV, UL
Number of input channels: 8
Input voltage:
115 Vac,
±
15%
Input frequency: 50-60 Hz
Input current:
Input LOW:
< 16 mA at 115 Vac
I
≤
1 mA (see 'Field cable length'
section in this data sheet)
Module dimensions:
DIN EN rails:
Used rail length:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
195 x 70 x 48 mm (L x W x H)
7.68 x 2.76 x 1.89 in (L x W x H)
TS32 / TS35 x 7.5
196 mm (7.72 in)
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
page 9-58 Version 2.0
FTA-T-07 data sheet
FTA-T-08
Description
Fail-safe digital output (relay contact)
FTA (4 channels)
The FTA-T-08 module has four fail-safe potential-free relay contact
(NO) output channels, created by two different relays connected in series. These relays are capable of driving a wide variety of loads including 115/230 Vac, which gives the FSC system a fail-safe
115/230 Vac output capability.
The energized state of the relay is indicated by an LED on the module.
Four channels can be connected to the FTA-T-08 module via a system interconnection cable (SIC). This cable is plugged into the SIC connectors on the FTA module. The SIC connector is marked '1A'
(white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
FTA-T-08 data sheet
Figure 1 Mechanical layout
Version 2.0
page 9-59
Each channel consists of:
• two relays of different manufacturers,
• a fused NO field contact (3.15 AT), and
• a status indicator LED.
The module has a common readback circuit for all four channels, which is closed if all relays are functioning correctly. If the readback circuit is opened, this indicates that one of the relays of the FTA is faulty.
Applications
Figure 2 Schematic diagram
For details on applications and connection options for the FTA-T-08 module refer to the 'SIC to FTA applications' data sheet.
page 9-60 Version 2.0
FTA-T-08 data sheet
Connections
The connections diagram of the FTA-T-08 module is as follows:
CONNECTIONS DIAGRAM FTA-T-08
SIC connector Field terminals
Technical data
General
Input
Output
1
1
1
1
1
1
1
1
1
1 nc = not connected
A5 CH1+
B5 CH1-
A4 CH2+
B4 CH2-
A3 CH3+
B3 CH3-
A2 CH4+
B2 CH4-
A1 nc
B1 nc
Readback 1
Readback 2
ALL FUSES 3.15 AT
OUT 1a
OUT 1b (fused)
OUT 2a (fused)
OUT 2b
OUT 3a
OUT 3b (fused)
OUT 4a (fused)
OUT 4b
1
2
11
12
21
22
31
32
41
42
Figure 3 Connections diagram
The FTA-T-08 module has the following specifications:
Type number:
Approvals:
FTA-T-08
CE, TÜV, UL
Nominal input voltage:
Max. input voltage:
Relay cut-in voltage:
Input current:
24 V
31 V
19 V typically 50 mA at 24 V
Number of output channels: 4
Max. output current: 3.15 A
Min. output current: 400 mA at 24 Vdc
Max. output voltage:
Max. output load:
250 Vac / 150 Vdc
800 VA / 150 W
FTA-T-08 data sheet Version 2.0
page 9-61
Technical data (continued)
Fuses
Physical
Termination
Relay contact
Rating:
Dimensions:
Module dimensions:
DIN EN rails:
Used rail length:
3.15 AT (slow-acting)
5 x 20 mm (0.2 x 0.78 in) or
5 x 25 mm (0.2 x 0.98 in)
145 x 70 x 65 mm (L x W x H)
5.71 x 2.76 x 2.56 in (L x W x H)
TS32 / TS35 x 7.5
146 mm (5.75 in)
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
Max. current:
Max. switched voltage:
Max. switched load:
5 A
250 Vac / 150 Vdc
1250 VA / 150 W
Max. switched frequency: 20 Hz
Expected life:
− electrical
− mechanical
Ambient temperature:
Contact material:
80,000 switch operations
5,000,000 switch operations
–40
°
C to +60 silver alloy
°
C (–40°F to +140°F)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
page 9-62 Version 2.0
FTA-T-08 data sheet
FTA-T-09
Description
Fail-safe passive digital input FTA
(115 Vac/dc, 8 channels)
The field termination assembly module FTA-T-09 is an eight-channel fail-safe input converter module, universal for both 115 Vac and/or
115 Vdc. All inputs are galvanically isolated.
Each channel converts an externally supplied 115 V input signal to a
24 Vdc input signal which can be connected to the 24 Vdc fail-safe input module 10101/2/1, thus creating a fail-safe 115 V input for the
FSC system.
Eight channels can be connected to the FTA-T-09 module via a system interconnection cable (SIC). This cable is plugged into the SIC connector on the FTA module. The SIC connector is marked '1A'
(white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Figure 1 Mechanical layout
FTA-T-09 data sheet Version 2.0
page 9-63
Figure 2 Schematic diagram
Applications
For details on applications and connection options for the FTA-T-09 module refer to the 'SIC to FTA applications' data sheet.
Field cable lengths
High-impedance AC inputs – like the inputs on this FTA – have a limited capability of handling the wire capacitance of standard multicore field cables. The wire capacitance of the field cable acts as a shunt impedance over the field contact (see Figure 3).
page 9-64
Figure 3 Standard (multicore) field cable
Version 2.0
FTA-T-09 data sheet
FTA-T-09 data sheet
When the current through this shunt impedance exceeds the maximum
'LOW' current, the input may be activated by this shunt impedance, thus disabling the input function (by keeping the input activated continuously, i.e. ON). Every AC input will have a maximum 'LOW' current that it can handle.
The maximum allowable cable length depends on the maximum
'LOW' current (e.g. 1.2 mA), the typical cable capacitance (e.g.
120 pF/m), the maximum supply voltage (e.g. 130 Vac) and the supply frequency (e.g. 60 Hz).
The maximum length (in meters) can be calculated using the following formula:
L max
=
I low
V max
2 f C where:
I
L max
= maximum allowable cable length low
= maximum 'LOW' current f
V max
= maximum supply voltage
= supply frequency
C typ
= typical cable capacitance
As an example, we will calculate the maximum field cable length (in meters) using the values mentioned above:
L max
=
∗
∗ ∗ ∗ ∗ ∗
-12
)
=
204 m
In this example, the maximum allowable field cable length is 204 meters (223 yards).
Solutions:
The field cable length limit can be eliminated by using field cables with wires that are shielded separately (see Figure 4).
The only (relevant) capacitance of the input wire is to the shield
(0 Vac or earth) and this will not activate a 'LOW' input.
However, this type of cable is rather unusual. Field cables with shielded wire pairs are more commonly used. This allows for two connections methods:
1. Use the method of Figure 4 and leave the second wire of each pair unconnected, or
2. Connect the second wire of each pair to 0 Vac (see Figure 5). The
115 Vac / 0 Vac supply pair can be used for more than one input.
Version 2.0
page 9-65
Figure 4 Field cable with separately shielded wires
Figure 5 Field cable with shielded pairs
In practice, a mix of wiring methods may be used. For example, use a cable with shielded pairs between the control cabinet and a distribution box close to the process. This cable may be long, e.g.
3 km (1.8 mi). Then use a standard (multicore) cable for the connection between the distribution box and the field contact. This cable length is limited to the value calculated using the formula mentioned above.
page 9-66 Version 2.0
FTA-T-09 data sheet
Connections
The connections diagram of the FTA-T-09 module is as follows:
CONNECTIONS DIAGRAM FTA-T-09
SIC connector Field terminals
1
1
1
1
1
1
1
1
1
1
A5
B5
A4
B4
A3
B3
CH1
CH2
CH3
CH4
CH5
CH6
A2 CH7
B2 0 Vdc
A1 CH8
B1 0 Vdc
IN 5a
IN 5b
IN 6a
IN 6b
IN 7a
IN 7b
IN 8a
IN 8b
IN 1a
IN 1b
IN 2a
IN 2b
IN 3a
IN 3b
IN 4a
IN 4b
Figure 6 Connections diagram
9
10
11
12
13
14
15
16
6
7
8
3
4
1
2
5
FTA-T-09 data sheet Version 2.0
page 9-67
Technical data
General
Input
Physical
Isolation
Termination
The FTA-T-09 module has the following specifications:
Type number:
Approval:
FTA-T-09
CE, TÜV
Number of input channels: 8
Input voltage:
115 V, –15% ... + 30%
Input frequency:
Input current:
DC or 40...300 Hz
7.5 mA (
±
1 mA) at 115 V
Input impedance:
Input LOW: non-inductive, > 9 kOhm
U
≤
15 V or
I
≤
1.2 mA (see 'Field cable length'
section in this data sheet)
Module dimensions:
DIN EN rails:
Used rail length:
Isolation input to output:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
180 x 70 x 48 mm (L x W x H)
7.09 x 2.76 x 1.89 in (L x W x H)
TS32 / TS35 x 7.5
181 mm (7.13 in)
2 kV
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
page 9-68 Version 2.0
FTA-T-09 data sheet
FTA-T-10 Digital output (relay contact) FTA
(8 channels)
Description
The field termination assembly module FTA-T-10 is the interface between the system interconnection cables (SICs) and the external field wiring (screw terminals). It has eight non-fail-safe potential-free relay contact (NO) outputs. The energized state of the relay is indicated by an LED on the module.
Eight channels can be connected to the FTA-T-10 module via a system interconnection cable (SIC). This cable is plugged into the SIC connector on the FTA module.
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Figure 1 Mechanical layout
Each channel consists of:
• one relay,
• a fused NO field contact (5 AT), and
• a status indicator LED.
FTA-T-10 data sheet Version 1.1 page 9-69
Applications
Connections
Figure 2 Schematic diagram
For details on applications and connection options for the FTA-T-10 module refer to the 'SIC to FTA applications' data sheet.
The connections diagram of the FTA-T-10 module is as follows:
CONNECTIONS DIAGRAM FTA-T-10
SIC connector Field terminals
page 9-70
1
1
1
1
1
1
1
1
1
1
A5
B5
A4
B4
A3
B3
A2
B2
A1
B1
CH1
CH2
CH3
CH4
CH5
CH6
CH7
0 Vdc
CH8
0 Vdc
ALL FUSES 5 AT
OUT 1a (fused)
OUT 1b
OUT 2a (fused)
OUT 2b
OUT 3a (fused)
OUT 3b
OUT 4a (fused)
OUT 4b
OUT 5a (fused)
OUT 5b
OUT 6a (fused)
OUT 6b
OUT 7a (fused)
OUT 7b
OUT 8a (fused)
OUT 8b
9
10
11
12
13
14
15
16
3
4
5
6
7
8
1
2
Figure 3 Connections diagram
Version 1.1
FTA-T-10 data sheet
Technical data
General
Input
Output
Fuses
Physical
Termination
Relay contacts
FTA-T-10 data sheet
The FTA-T-10 module has the following specifications:
Type number:
Approvals:
FTA-T-10
CE, TÜV;
UL approval pending
Nominal input voltage:
Max. input voltage:
Relay cut-in voltage:
Input current:
24 Vdc
31 Vdc
19 Vdc typically 27 mA at 24 Vdc
Number of output channels: 8
Max. output current: 5 A
Max. output voltage:
Max. switched load:
250 Vac / 300 Vdc
2500 VA / 150 W at 30 Vdc
(see Figure 4)
Rating:
Dimensions
5 AT (slow-acting)
5 x 20 mm (0.20 x 0.79 in)
Module dimensions:
DIN EN rails:
Used rail length:
190 x 70 x 60 mm (L x W x H)
7.48 x 2.76 x 2.36 in (L x W x H)
TS32 / TS35 x 7.5
191 mm (7.52 in)
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
Max. current:
Max. switched voltage:
8 A
250 Vac / 300 Vdc
Max. switched load: 4000 VA / 192 W at 24 Vdc
(see Figure 4)
Max. switching frequency: 20 Hz
Expected life:
− electrical
− mechanical
100,000 switch operations
30,000,000 switch operations
Version 1.1
page 9-71
Technical data (continued)
Relay contacts
(cont.)
Isolation:
− coil to contact
− contact to contact
Ambient temperature:
Contact material:
4000 Vac
1000 Vac
–40°C to +70°C (–40°F to +158°F) silver-cadmium oxide
V
300
200
U
150
100
75
50
40
30
20
15
10
0.2
0.3
0.4 0.5 0.75 1
U = Switching voltage (DC)
I = Switching current
1.5
2 3 4 5 7.5 10 A
I
Figure 4 Maximum DC switched power curve for FTA-T-10 module
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
page 9-72 Version 1.1
FTA-T-10 data sheet
FTA-T-11
Description
Fail-safe digital output FTA
(110 Vdc, 8 channels)
The field termination assembly module FTA-T-11 is the interface between the system interconnection cables (SIC) and the external field wiring (screw terminals).
It was specially developed to meet isolation requirements for higher voltages in accordance with IEC 1010 (1990), overvoltage category 3
(Table D.12).
Eight channels (separated into two groups of four channels) can be connected to the FTA-T-11 module via system interconnection cables
(SIC). These cables are plugged into the SIC connectors on the FTA module. The two SIC connectors are marked '1A' and '2A' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
FTA-T-11 data sheet
Figure 1 Mechanical layout
Version 2.0
page 9-73
Applications
Connections
For details on applications and connection options for the FTA-T-11 module refer to the 'SIC to FTA applications' data sheet.
The connections diagram of the FTA-T-11 module is as follows:
CONNECTIONS DIAGRAM FTA-T-11
SIC connector Field terminals
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A5
B5
A4
B4
A3
B2
A1
B1
CH 1-
CH 1+
CH 2+
CH 2-
CH 3-
B3 CH 3+
A2 CH 4+
CH 4nc nc
2A
2A
2A
2A
2A
2A
2A
2A
2A
2A nc = not connected
A5 CH 5-
B5 CH 5+
A4 CH 6+
B4 CH 6-
A3 CH 7-
B3 CH 7+
A2 CH 8+
B2
A1
B1
CH 8nc nc
Figure 2 Connections diagram
OUT 1a
OUT 1b
OUT 2a
OUT 2b
OUT 3a
OUT 3b
OUT 4a
OUT 4b
OUT 5a
OUT 5b
OUT 6a
OUT 6b
OUT 7a
OUT 7b
OUT 8a
OUT 8b
11
12
13
14
7
8
9
10
15
16
4
5
6
1
2
3 page 9-74 Version 2.0
FTA-T-11 data sheet
Technical data
General
Power
Physical
Termination
The FTA-T-11 module has the following specifications:
Type number:
Approvals:
FTA-T-11
CE, TÜV
Number of channels:
Maximum voltage:
8 (2 groups of 4)
100 Vac / 120 Vdc – IEC 1010 (1990), overvoltage category 3 (Table D.12)
Max. continuous current per channel: 2 A
Module dimensions:
DIN EN rails:
Used rail length:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
130 x 70 x 48 mm (L x W x H)
5.12 x 2.76 x 1.89 in (L x W x H)
TS32 / TS35 x 7.5
131 mm (5.16 in)
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-11 data sheet Version 2.0
page 9-75
Left blank intentionally.
page 9-76 Version 2.0
FTA-T-11 data sheet
FTA-T-12
Description
Isolated passive digital input FTA
(8 channels)
The field termination assembly module FTA-T-12 is the interface between the system interconnection cables (SICs) and the external field wiring (screw terminals). It has eight non-fail-safe isolated
24 Vdc input channels.
Eight channels can be connected to the FTA-T-12 module via a system interconnection cable (SIC). This cable is plugged into the SIC connector on the FTA module.
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Figure 1 Mechanical layout
FTA-T-12 data sheet Version 1.1
page 9-77
Applications
Connections
Figure 2 Schematic diagram
For details on applications and connection options for the FTA-T-12 module refer to the 'SIC to FTA applications' data sheet.
The connections diagram of the FTA-T-12 module is as follows:
CONNECTIONS DIAGRAM FTA-T-12
SIC connector Field terminals
page 9-78
1
1
1
1
1
1
1
1
1
1
A3
B3
A2
B2
A5
B5
A4
B4
CH1
CH2
CH3
CH4
CH5
CH6
CH7 nc
A1 CH8
B1 +24 Vdc nc = not connected
Figure 3 Connections diagram
IN 1+
IN 1-
IN 2+
IN 2-
IN 3+
IN 3-
IN 4+
IN 4-
IN 5+
IN 5-
IN 6+
IN 6-
IN 7+
IN 7-
IN 8+
IN 8-
Version 1.1
FTA-T-12 data sheet
3
4
1
2
5
6
7
8
9
10
11
12
13
14
15
16
Technical data
General
Input
Output
Physical
Termination
Isolation
The FTA-T-12 module has the following specifications:
Type number:
Approvals:
FTA-T-12
CE, TÜV;
UL approval pending
Number of input channels: 8
Nominal input voltage: 24 Vdc
Drop-out voltage: 2.8 Vdc
Pick-up voltage:
Max. input voltage:
17.5 Vdc
47.5 Vdc
Reverse polarity protection: series diode
Max. reverse voltage: 300 V
Input current: typically 9 mA at 24 Vdc
Max. switching frequency: 20 Hz
Output voltage:
Output current:
Contact material:
0.1 to 36 V
10 µA to 1 A gold-clad silver alloy
150 x 70 x 48 mm (L x W x H)
5.91 x 2.76 x 1.89 in (L x W x H)
TS32 / TS35 x 7.5
151 mm
Module dimensions:
DIN EN rails:
Used rail length:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
Galvanic isolation:
− input to output
− input to input
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
1000 Vac
1000 Vac
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-12 data sheet Version 1.1
page 9-79
Left blank intentionally.
page 9-80 Version 1.1
FTA-T-12 data sheet
FTA-T-13
Description
Current-limited digital input FTA
(24 Vdc, 16 channels)
The field termination assembly module FTA-T-13 is the interface between the system interconnection cables (SICs) and the external field wiring (screw terminals). It can be used for interfacing digital input signals from Class I, Division 2 Hazardous Locations.
Sixteen channels (separated into two groups of eight channels with a
250 mA fuse in the common +) can be connected to the FTA-T-13 module via SIC cables. These cables are plugged into the SIC connectors on the FTA module. The two SIC connectors are marked
'1A' and '1B' (white print on the board).
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Figure 1 Mechanical layout
FTA-T-13 data sheet Version 1.2
page 9-81
Applications
Connections
For details on applications and connection options for the FTA-T-13 module refer to the 'SIC to FTA applications' data sheet.
The connections diagram of the FTA-T-13 module is as follows:
CONNECTIONS DIAGRAM FTA-T-13
SIC connector Field terminals
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
A5
B5
A4
B4
A3
B3
A2
B2
CH1
CH2
CH3
CH4
CH5
CH6
CH7 nc
A1 CH8
B1 +24 Vdc
0.25 AT
1B
1B
1B
1B
1B
1B
1B
1B
1B
1B
A3
B3
A2
B2
A5
B5
A4
B4
CH9
CH10
CH11
CH12
CH13
CH14
CH15 nc
A1 CH16
B1 +24 Vdc
0.25 AT nc = not connected
R
26
27
28
29
30
31
32
21
22
23
24
25
17
18
19
20
10
11
12
13
14
15
16
7
8
5
6
9
3
4
1
2
CH1+ (via fuse 1)
CH1-
CH2+ (via fuse 1)
CH2-
CH3+ (via fuse 1)
CH3-
CH4+ (via fuse 1)
CH4-
CH5+ (via fuse 1)
CH5-
CH6+ (via fuse 1)
CH6-
CH7+ (via fuse 1)
CH7-
CH8+ (via fuse 1)
CH8-
CH9+ (via fuse 2)
CH9-
CH10+ (via fuse 2)
CH10-
CH11+ (via fuse 2)
CH11-
CH12+ (via fuse 2)
CH12-
CH13+ (via fuse 2)
CH13-
CH14+ (via fuse 2)
CH14-
CH15+ (via fuse 2)
CH15-
CH16+ (via fuse 2)
CH16-
Figure 2 Connections diagram page 9-82 Version 1.2
FTA-T-13 data sheet
Technical data
General
Input
Termination
Physical
Field signal specifications
The FTA-T-13 module has the following specifications:
Type number:
Approvals:
FTA-T-13
CE, TÜV;
UL, FM approvals pending
Number of input channels: 16 (2 isolated groups of 8)
Input voltage:
Input current:
24 Vdc, –15% … +30%
≤
15 mA at 24 Vdc (with a redundant pair of fail-safe digital input modules
10101/2/1 as load)
Igniting current per channel: < 100 mA at 24 Vdc +30%
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
Module dimensions:
DIN EN rails:
Used rail length:
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
170 x 70 x 60 mm (L x W x H)
6.69 x 2.76 x 2.36 in (L x W x H)
TS32 / TS35 x 7.5
171 mm
Max. closed loop resistance: 250 Ohm
Min. open loop resistance: 15 kOhm
HYDROGEN (Group A & B):
− max. loop inductance
8 mH
− max. loop capacitance
0.3 µF
NON-HYDROGEN (Group C & D):
− max. loop inductance
22 mH
− max. loop capacitance
7 µF
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-13 data sheet Version 1.2
page 9-83
Left blank intentionally.
page 9-84 Version 1.2
FTA-T-13 data sheet
FTA-T-14
Description
Fail-safe 0(4)-20 mA analog input FTA
(16 channels)
The field termination assembly module FTA-T-14 is the interface between field components (sensors, etc.) and the fail-safe highdensity analog input module 10105/2/1 in the FSC system. It can be used for interfacing signals from Class I, Division 2 Hazardous
Locations.
The FTA-T-14 module has sixteen analog input channels which may be used for both safety-related and non-safety-related applications.
These sixteen channels (separated into two groups of eight channels with common 0 V) are connected to the FTA-T-14 module via a system interconnection cable (SIC), which is plugged into the SIC connector on the FTA module.
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connection of power supply, ground and field wiring.
FTA-T-14 data sheet
Figure 1 Mechanical layout
Version 1.2
page 9-85
Main functions
The FTA-T-14 module has three main functions:
• linear direct conversion of 0(4)-20 mA DC field signals to the signal levels of the fail-safe high-density analog input module 10105/2/1,
• power supply distribution to each transmitter with voltage-current limitation in compliance with Hazardous Area Class I Division 2, and
• enable monitoring of the external power connected to the FTA-T-14 module.
Linear direct conversion
The input circuit of each channel consists of a high-precision resistor which converts the input current (0 to 20 mA) to the input voltage for the high-density analog input module 10105/2/1. The power to the analog transmitter is supplied via a series resistor. Each analog signal has its own terminal for the field cable shield.
Figure 2 below shows the schematic diagram for connecting a transmitter (active and passive).
R
V+
30 Vx
Vext mA
+
(0)4-20 mA transmitter
_
0 V
Ground
R
R
R
30 Vx
OUT
Vext
SIC connector
+
(0)4-20 mA transmitter
_
0 Vdc
/
V+ mA
0 V
Ground
R
R
OUT
0 Vdc
/
SIC connector
"Active transmitter" "Passive transmitter"
Figure 2 Schematic diagram for connecting a transmitter
Class I Division 2
The FTA-T-14 module may be used in areas with Class I, Division 2 applications. The external output voltage (V+) is current-limited by means of a series resistor.
page 9-86 Version 1.2
FTA-T-14 data sheet
Transmitter voltage
Figure 3 below shows the available transmitter voltage for passive transmitters.
Transmitter
Voltage [V]
30.0
> 19.0
> 16.4
External power
0.0
20.0
25.0
Transmitter
Current [mA]
Figure 3 Transmitter voltage for passive transmitters
If all inputs are active, no external power is required.
For loops which contain passive transmitters, analog process data is only available if the supply voltage to the electronics is guaranteed.
The high-density analog input concept (using FTA-T-14/15 modules) offers full monitoring of power that is provided externally. If DC/DC converter modules FTA-T-15 are used, even redundant power supplies are covered.
External power can be connected to the FTA-T-14 module via one or both of the two screw terminal pairs marked '1A', '1B', '2A' and '2B'.
The screw terminal pairs are interconnected on the FTA module. The sixteen channels on the FTA module are divided into two groups of eight channels, with each group being protected by a 315 mA fuse.
Single-channel errors (shorts from V+ to 0 V) cannot blow the group fuse.
Note:
The 0 V connection of the external power is directly connected to the common 0 V of all sixteen analog inputs.
The FSC software can monitor the external power voltage via the fail-safe high-density analog input module 10105/2/1.
FTA-T-14 data sheet Version 1.2
page 9-87
Figure 4 below shows the schematic diagram for power distribution with monitoring.
1A
1B
315 mA
30 Vdc
+
-
30 V1
To channels 1 to 8
30 Vdc
(optional)
+
-
2A
2B
315 mA
R
30 V2
To channels 9 to 16
R
Vext/8
Readback Vext
(to SIC connector)
R
0 Vdc
Figure 4 Schematic diagram for power distribution with monitoring
Applications
For details on applications and connection options for the FTA-T-14 module refer to the 'SIC to FTA applications' data sheet.
Connections
External power and ground
Connections diagram
The external supply voltage (Vext) and ground are connected to the following screw terminals (marked '1A', '1B', '2A', '2B' and ' / ' on the
FTA):
Screw terminal Function
1A
1B
2A
2B
/
/
30 Vdc Vext
0 Vdc Vext
30 Vdc Vext
0 Vdc Vext
Ground connection
Ground connection
The FTA-T-14 module has sixteen groups (= sixteen channels) of four screw terminals to provide optimum connection of field wiring, with a ground terminal per channel for screening of analog input cables. The screw terminals are numbered 1 to 64. The connections diagram of the
FTA-T-14 module is as follows: page 9-88 Version 1.2
FTA-T-14 data sheet
Connections diagram
FTA-T-14 data sheet
SIC connector
CONNECTIONS DIAGRAM FTA-T-14
Field terminals
30 Vdc ext.
2A +
2B -
315 mAT
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
CH6
CH7
CH8
CH9
CH10
CH11
CH12
0 Vdc
0 Vdc
CH1
CH2
CH3
CH4
CH5
CH13
CH14
CH15
CH16
0 Vdc
+Vext/8
B7
A6
B6
A5
B5
A4
B4
A10
B10
A9
B9
A8
B8
A7
A3
B3
A2
B2
A1
B1
30 Vdc ext.
1A +
1B -
315 mAT
58
59
60
54
55
56
57
61
62
63
64
51
52
53
48
49
50
43
44
45
46
47
40
41
42
37
38
39
33
34
35
36
CH9 (V+)
CH9 (ground)
CH9 (mA input)
CH9 (0 V)
CH10 (V+)
CH10 (ground)
CH10 (mA input)
CH10 (0 V)
CH11 (V+)
CH11 (ground)
CH11 (mA input)
CH11 (0 V)
CH12 (V+)
CH12 (ground)
CH12 (mA input)
CH12 (0 V)
CH13 (V+)
CH13 (ground)
CH13 (mA input)
CH13 (0 V)
CH14 (V+)
CH14 (ground)
CH14 (mA input)
CH14 (0 V)
CH15 (V+)
CH15 (ground)
CH15 (mA input)
CH15 (0 V)
CH16 (V+)
CH16 (ground)
CH16 (mA input)
CH16 (0 V)
Figure 5 Connections diagram
28
29
30
25
26
27
31
32
22
23
24
17
18
19
20
21
12
13
14
15
16
9
10
11
6
7
4
5
8
1
2
3
CH1 (V+)
CH1 (ground)
CH1 (mA input)
CH1 (0 V)
CH2 (V+)
CH2 (ground)
CH2 (mA input)
CH2 (0 V)
CH3 (V+)
CH3 (ground)
CH3 (mA input)
CH3 (0 V)
CH4 (V+)
CH4 (ground)
CH4 (mA input)
CH4 (0 V)
CH5 (V+)
CH5 (ground)
CH5 (mA input)
CH5 (0 V)
CH6 (V+)
CH6 (ground)
CH6 (mA input)
CH6 (0 V)
CH7 (V+)
CH7 (ground)
CH7 (mA input)
CH7 (0 V)
CH8 (V+)
CH8 (ground)
CH8 (mA input)
CH8 (0 V)
Version 1.2
page 9-89
Technical data
General
Input
Output
Fuses
Physical
Termination
Field signal specifications
The FTA-T-14 module has the following specifications:
Type number:
Approvals:
FTA-T-14
CE;
UL, FM, TÜV approvals pending
Number of input channels: 16 (2 groups of 8 with common 0 V)
Power requirements:
Input current:
Input resistance:
30 Vdc external 3 mA
(without input loop loads)
0 to 25 mA
250 Ohm (± 1%)
To passive transmitters (Vext):
− output resistance:
270 Ohm (± 5%)
− igniting current per channel:
< 120 mA at 30 Vdc
To 10105/2/1 module:
− output voltage
0 to 4 Vdc
Rating:
Dimensions:
Module dimensions:
315 mAT (slow-acting)
5 x 20 mm (0.20 x 0.79 in)
200 x 70 x 60 mm (L x W x H)
7.87 x 2.76 x 2.36 in (L x W x H)
TS32 / TS35 x 7.5
201 mm (7.91 in)
DIN EN rails:
Used rail length:
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
HYDROGEN (Group A & B):
− max. loop inductance
6 mH
− max. loop capacitance
0.25 µF
NON-HYDROGEN (Group C & D):
− max. loop inductance
20 mH
− max. loop capacitance
5 µF page 9-90 Version 1.2
FTA-T-14 data sheet
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-14 data sheet Version 1.2
page 9-91
Left blank intentionally.
page 9-92 Version 1.2
FTA-T-14 data sheet
FTA-T-15
Description
24 Vdc to 30 Vdc/1 A converter
The FTA-T-15 module is a DC/DC converter, which is used to provide an isolated 30 Vdc / 1 A to other field termination assemblies
(FTAs), e.g. the analog input FTA module FTA-T-14 or the active analog input FTA module FTA-T-16. It has voltage monitoring capabilities with local LED indication and also provides alarm functions (readback relay contact). The LED is on and the relay contact is closed if the local DC/DC output voltage is OK.
Figure 1 Mechanical layout
FTA-T-15 data sheet Version 1.1
page 9-93
Applications
Connections
For details on applications and connection options for the FTA-T-15 module refer to the 'SIC to FTA applications' data sheet.
The FTA-T-15 module has four screw terminals for connection of incoming power wires and the readback wiring. The screw terminals are numbered 1 to 4. The function of each terminal is listed below:
Screw terminal Function
3
4
1
2
Readback contact
Readback contact
24 Vdc IN +
24 Vdc IN –
Note:
Removal or connection of the 24 Vdc IN+ and/or 24 Vdc IN– wire(s) is only allowed when the 24 Vdc power supply to the
FTA-T-15 module has been switched off.
The FTA-T-15 module has twelve screw terminals for connection of outgoing power wires. The screw terminals are numbered '1A', '1B',
'2A', etc. to '6B'. The function of each terminal is listed below:
Screw terminal Function
1A
1B
2A
2B
3A
3B
4A
4B
5A
5B
6A
6B
30 Vdc OUT
0 Vdc OUT
30 Vdc OUT
0 Vdc OUT
30 Vdc OUT
0 Vdc OUT
30 Vdc OUT
0 Vdc OUT
30 Vdc OUT
0 Vdc OUT
30 Vdc OUT
0 Vdc OUT page 9-94 Version 1.1
FTA-T-15 data sheet
Technical data
General
Input
Output
Physical
Fuse
The FTA-T-15 module has the following specifications:
Type number:
Approvals:
Safety class:
MTBF:
FTA-T-15
CE, UL, TÜV approvals pending
AK1-6 approx. 400,000 hours
Nominal input voltage:
Input voltage range:
Inrush current:
Output voltage:
Output current:
Short-circuit current:
Ripple (0-30 MHz):
Regulation:
Transient response:
Power-on overshoot:
Long-term stability (after
30 min. operation):
Efficiency:
Switching frequency:
24 Vdc
18 to 36 Vdc
≤
4 A (see note below)
30 Vdc,
±
0.25 V
1 A (short-circuit proof)
< 3.3 A
< 0.1 Vrms
< 1% (load + line) class C according to NFC42801C output
≤
31 V
< 0.3%
> 75%
> 25 kHz
Module dimensions:
DIN EN rails:
Used rail length:
150 x 70 x 62.3 mm (L x W x H)
5.91 x 2.76 x 2.45 in (L x W x H)
TS32 / TS35 x 7.5
151 mm (5.94 in)
Rating:
Dimensions:
3.15 AT (slow-acting)
5 x 20 mm (0.2 x 0.79 in)
Note:
The inrush current limiter is only active at power-on.
To regain the inrush current limiting function, the FTA-T-15 module must be switched off for at least 30 seconds. Switching on the module within 30 seconds may blow a fuse or activate a circuit breaker.
FTA-T-15 data sheet Version 1.1
page 9-95
Technical data (continued)
Termination
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
Isolation
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
Isolation voltage:
− input to output
− input to relay contact
2000 Vac (1 min.)
2000 Vac (1 min.)
− output to relay contact
2000 Vac (1 min.)
Environment
Operating temperature:
Storage temperature:
Cooling:
–5°C to +70°C (23°F to 158°F)
–40°C to +85°C (–40°F to +185°F) natural convection
Alarm functions
Readback
Overvoltage protection:
Restart overvoltage protection:
Undervoltage detector:
Undervoltage level:
Relay contact rating: dual, two-fault-tolerant only after removal of 24 Vdc power
LED on if voltage OK, readback relay contact closed if voltage OK typically 27.5 Vdc
36 Vdc / 40 mA, 30 Vac / 40 mA
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
page 9-96 Version 1.1
FTA-T-15 data sheet
FTA-T-16
Description
Fail-safe active digital input FTA with line-monitoring (16 channels)
The field termination assembly module FTA-T-16 is the interface between field components (sensors, etc.) and the fail-safe high-density analog input module 10105/2/1 in the FSC system. It can be used for interfacing signals from Class I, Division 2 Hazardous
Locations.
The FTA-T-16 module has sixteen digital input channels which may be used for both safety-related and non-safety-related applications.
These sixteen channels are connected to the FTA-T-16 module via a system interconnection cable (SIC), which is plugged into the SIC connector on the FTA module.
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connection of power supply and field wiring.
FTA-T-16 data sheet
Figure 1 Mechanical layout
Version 1.1
page 9-97
Main functions
The FTA-T-16 module has three main functions:
• loop-monitored input function,
• power supply to each transmitter with voltage-current limitation in compliance with Hazardous Area Class I Division 2, and
• enable monitoring of the external power connected to the FTA-T-16 module.
Loop-monitored input
The FTA-T-16 module supports a loop-monitored input function for serial and parallel field resistor or digital sensor contact configurations. Figure 2 below shows the schematic diagrams for connecting serial and parallel resistor configurations.
R
A
Field sensor contact
R
B
Ch+
Ch-
R
30 V
Vext
Field sensor contact
R
R
Ch
0 V
SIC connector
R
A
R
B
Ch+
Ch-
R
30 V
Vext
R
R
Ch
0 V
SIC connector
"Serial" "Parallel"
Figure 2 Schematic diagrams for connecting serial and parallel resistor configurations
In these configurations, R
A
is 1.0 kOhm and R
B
is 3.3 kOhm or
10 kOhm (
±
10%). The maximum field wire resistance is 500 Ohm.
Monitoring of external power
External power can be connected to the FTA-T-16 module via one or both of the two screw terminal pairs marked '1A', '1B', '2A' and '2B'.
The screw terminal pairs are interconnected on the FTA module.
The FSC software can monitor the external power voltage via the analog input module.
page 9-98 Version 1.1
FTA-T-16 data sheet
Applications
Figure 3 below shows the schematic diagram for power distribution with monitoring.
30 Vdc
+
-
1A
1B
30 V
To channels 1 to 16
R
+
30 Vdc
(optional)
-
2A
2B R
Vext/8
Readback Vext
(to SIC connector)
0 Vdc
Figure 3 Schematic diagram for power distribution with monitoring
For details on applications and connection options for the FTA-T-16 module refer to the 'SIC to FTA applications' data sheet.
Connections
External power
The external supply voltage (Vext) is connected to the following screw terminals (marked '1A', '1B', '2A' and '2B' on the FTA):
Screw terminal Function
1A
1B
2A
2B
30 Vdc Vext
0 Vdc Vext
30 Vdc Vext
0 Vdc Vext
FTA-T-16 data sheet Version 1.1
page 9-99
Connections diagram
The FTA-T-16 module has 32 screw terminals for connection of field wiring. The screw terminals are numbered 1 to 32. The connections diagram of the FTA-T-16 module is as follows:
CONNECTION DIAGRAM FTA-T-16
SIC connector Field terminals
30 Vdc ext.
2A +
2B -
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0 Vdc
0 Vdc
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
CH10
CH11
CH12
CH13
CH14
CH15
CH16
0 Vdc
+Vext/8
B7
A6
B6
A5
B5
A4
A10
B10
A9
B9
A8
B8
A7
B4
A3
B3
A2
B2
A1
B1
30 Vdc ext.
2A +
2B -
Figure 4 Connections diagram
CH1+
CH1-
CH2+
CH2-
CH3+
CH3-
CH4+
CH4-
CH5+
CH5-
CH6+
CH6-
CH7+
CH7-
CH8+
CH8-
10
11
12
13
14
15
16
8
9
6
7
3
4
1
2
5
CH9+
CH9-
CH10+
CH10-
CH11+
CH11-
CH12+
CH12-
CH13+
CH13-
CH14+
CH14-
CH15+
CH15-
CH16+
CH16-
25
26
27
28
29
30
31
32
17
18
19
20
21
22
23
24 page 9-100 Version 1.1
FTA-T-16 data sheet
Technical data
General
Input
Output
Physical
Termination
Field signal specifications
The FTA-T-16 module has the following specifications:
Type number:
Approvals:
FTA-T-16
CE;
UL, FM, TÜV approvals pending
Number of input channels: 16
Power requirements: 30 Vdc external 150 mA
(all inputs closed)
Max. current per channel: < 12 mA at 30 Vdc
To passive transmitters (Vext):
− open voltage typically 24 Vdc
To 10105/2/1 module:
− output voltage
0 to 3.5 Vdc
Module dimensions:
DIN EN rails:
Used rail length:
110 x 70 x 60 mm (L x W x H)
4.33 x 2.76 x 2.36 in (L x W x H)
TS32 / TS35 x 7.5
111 mm (4.37 in)
Screw terminals:
− max. wire diameter
− strip length
− tightening torque
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
Field wire resistance: < 500 Ohm
Field device resistance (see Figure 2):
−
R
A
−
R
B
1k0 (serial or parallel), ± 10%
3k3 / 10k (serial or parallel), ± 10%
HYDROGEN (Group A & B):
− max. loop inductance
500 mH
− max. loop capacitance
0.3 µF
NON-HYDROGEN (Group C & D):
− max. loop inductance
1 H
− max. loop capacitance
7 µF
FTA-T-16 data sheet Version 1.1
page 9-101
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
page 9-102 Version 1.1
FTA-T-16 data sheet
FTA-T-17
Description
Digital output (relay) FTA for AK5/6 applications (4 channels)
The field termination assembly module FTA-T-17 is the interface between the system interconnection cables (SICs) and the external field wiring (screw terminals). It has four relay-based potential-free output channels suitable for applications up to AK6 without making use of fault exclusions.
The FTA-T-17 module complies with safety requirements for general use in safety requirement classes AK5/6 as defined in DIN V 19250.
Each channel consists of:
• three relays,
• a fused NO field contact (5 AT, slow-acting), and
• a status indication LED.
The relays are capable of driving a wide variety of loads including
115/230 Vac, which gives the FSC system a 115/230 Vac output capability for AK5/6 applications. The energized state of the relay is indicated by an LED on the module.
FTA-T-17 data sheet
Figure 1 Mechanical layout
Version 1.2
page 9-103
Four channels can be connected to the FTA-T-17 module via a system interconnection cable (SIC).This cable is plugged into the SIC connector on the FTA module.
The FTA module has a universal snap-in facility for standard DIN EN rails, and screw terminals for connecting field wiring.
Applications
Figure 2 Schematic diagram
For details on applications and connection options for the FTA-T-17 module refer to the 'SIC to FTA applications' data sheet.
page 9-104 Version 1.2
FTA-T-17 data sheet
Connections
The connections diagram of the FTA-T-17 module is as follows:
CONNECTIONS DIAGRAM FTA-T-17
SIC connector Field terminals
1
1
1
1
1
1
1
1
1
1 nc = not connected
A5 CH1+
B5 CH1-
A4 CH2+
B4 CH2-
A3 CH3+
B3 CH3-
A2 CH4+
B2 CH4-
A1
B1 nc nc
ALL FUSES 5 AT
OUT 1a
OUT 1b (fused)
OUT 2a
OUT 2b (fused)
OUT 3a
OUT 3b (fused)
OUT 4a
OUT 4b (fused)
3
4
5
1
2
6
7
8
Figure 3 Connections diagram
FTA-T-17 data sheet Version 1.2
page 9-105
Technical data
General
Input
Output
Fuses
Physical
Termination
Environment
Isolation
The FTA-T-17 module has the following specifications:
Type number:
Approvals:
Safety class:
FTA-T-17
CE;
UL, FM, TÜV approvals pending
AK1-6
Nominal input voltage:
Max. input voltage:
Relay pick-up voltage:
Input current:
Number of output channels: 4
Max. output current:
Min. output current:
Max. output voltage:
Max. switched load:
5 A
1 mA at 5 V
250 Vac / 250 Vdc
1250 VA / 150 W (see Figure 4)
Rating:
Dimensions:
24 Vdc
36 Vdc
19.2 Vdc typically 35 mA at 24 Vdc
Module dimensions:
DIN EN rails:
Used rail length:
5 AT (slow-acting)
5 x 20 mm (0.2 x 0.78 in)
160 x 70 x 60 mm (L x W x H)
6.30 x 2.76 x 2.36 in (L x W x H)
TS32 / TS35 x 7.5
161 mm (6.34 in)
Screw terminals:
− max. wire diameter:
− strip length:
− tightening torque
Ambient temperature:
2.5 mm² (AWG 14)
7 mm (0.28 in)
0.5 Nm (0.37 ft-lb)
–5
°
C to +60
°
C (23°F to 140°F)
Isolation:
− coil to contact
− contact to contact
3750 Vac
1200 Vac page 9-106 Version 1.2
FTA-T-17 data sheet
Technical data (continued)
Relay contact
Max. current:
Max. switched voltage:
Max. switched load:
Max. switch frequency:
Expected life:
− electrical
− mechanical
Contact material:
8 A
250 Vac / 250 Vdc
2000 VA / 150 W
20 Hz
100,000 switch operations
10,000,000 switch operations gold flash over silver alloy
AC, resistive load
10
5
AC, inductive load
(COS ϕ
= 0.4) 2
1
0.5
DC, resistive load
0.2
0.1
10 20 50 100
Voltage (V)
200 300
Figure 4 Maximum switched power
While this information is presented in good faith and believed to be accurate, Honeywell Safety Management Systems B.V.
disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer.
In no event is Honeywell Safety Management Systems B.V. liable to anyone for any indirect, special or consequential damages.
The information and specifications in this document are subject to change without notice.
FTA-T-17 data sheet Version 1.2
page 9-107
Left blank intentionally.
page 9-108 Version 1.2
FTA-T-17 data sheet
.