Service Information No. 01/2008
5.0 Assembly instructions / replacement of parts
5.1 General
5.1.1 Electronic control system
Covers:
Fig. 5.1.1/ 1 Left cover
Front panel:
Disengage covers at the marked points.
Fig. 5.1.1/ 2 Right cover
Unlock locating lugs at the left and right of the front panel.
Fig. 5.1.1/ 3 Left locating lug
PCB carrier:
Fig. 5.1.1/ 4 Right locating lug
Draw the front panel forwards for removal and expose the cables.
Disconnect and detach group connectors.
Fig. 5.1.1/ 5 Group connector
Fig. 5.1.1/ 6 Group connector
IGN 2556/2566
Fig. 5.1.1/ 7 Front panel assembly
Page 9/21
Service Information No. 01/2008
Magnet holder:
IGN 2556/2566
Press marked locating lugs together and detach magnet holder upwardly.
Magnet holder
Fig. 5.1.2 / 1
Page 10/21
Service Information No. 01/2008 IGN 2556/2566
Evaporator module
Locking parts
Remove top drawers
Fig. 5.2.1/ 1 Evaporator module
Locking parts:
Transit support:
Are snapped into place at the right and left for locking the evaporator module.
Remove the adhesive tape as transit support of the "top polystyrene moulding", it is no longer needed for assembly (Fig. 5.2.1/ 3).
Top polystyrene moulding: Lift off the polystyrene moulding first at the front, then at the back.
Draw the "top polystyrene moulding" forwards for removal.
Top polystyrene moulding
Fig. 5.2.1/ 2 Remove locking part
Adhesive tape
Fig. 5.2.1/ 3 Remove adhesive tape
Page 11/21
Service Information No. 01/2008 IGN 2556/2566
Evaporator module: Dismantle the evaporator module as described below under 5.2.1 Evaporator
module.
Evaporator sensor: repaired
Is slipped inbetween the lamellas and in case of defect it has to be cut off and with the repair kit (Art. No. 9590 062).
Temperature fuse
Fig. 5.2.2/ 1 Evaporator module folded down
Evaporator
Evaporator module: Dismantle the evaporator module as described below under 5.2.1 Evaporator
module.
Front polystyrene moulding: Is situated behind the front panel is the evaporator module (is only inserted).
Acts as an air seal of the air sensor in the direction of the lamellar evaporator.
Is engaged behind the front panel of the evaporator module and in case of defect it has to be cut off and repaired with the repair kit (Art. No. 9590 062).
Air sensor:
Fig. 5.2.3/ 1 Removal of the polystyrene Fig. 5.2.3/ 2 Air sensor
Page 12/21
Service Information No. 01/2008
5.2.4 Fan
IGN 2556/2566
Evaporator module: Dismantle the evaporator module as described below under 5.2.1 Evaporator
module.
Fan casing: and
Detach fan connector. Lift the fan casing out of the housing support, swing it down remove it.
Fan casing
Fig. 5.2.4/ 1 Fan casing
Fan:
Fan connector
Fig. 5.2.4/ 2 Fan casing, swung down
Lay the fan casing front face down, and remove the attached sealing rubber at the rear. Detach the fan from the housing.
Fig. 5.2.4/ 3 Fan housing, front face
Fig. 5.2.4/ 5 Fan housing, components
Sealing rubber
Fig. 5.2.4/ 4 Fan housing, rear
Page 13/21
Service Information No. 01/2008 IGN 2556/2566
Evaporator module: Dismantle the evaporator module as described below under 5.2.1 Evaporator
module.
Temperature fuse:
Fastened by a screw.
To be noted for replacement:
- Cut off only at the coloured wires (not heater wire!)
- Fix the wires in such a way that they do not touch the heater.
Screw
Temperature fuse
Fig. 5.2.5/ 1 Temperature fuse
Page 14/21
Fig. 5.2.7 / 1
Service Information No. 01/2008
5.2.6 IGN 2566 only, IceMaker
IGN 2556/2566
Holder:
for
Press the locating lugs in the two openings of the holder inwards and draw the holder forwards removal (see Fig. 5.2.6/ 1).
Reed contact: The reed contact for drawer recognition is situated in the holder.
Draw the IceMaker forwards and lower it for removal. Disconnect the IceMaker cables.
IceMaker:
Holder
Fig. 5.2.6/ 1 Disengaging the holder
Holder with reed contact
Fig. 5.2.6/ 2 Reed contact in holder Fig. 5.2.6/ 3 IceMaker
5.2.7 IGN 2566 only, double solenoid valve IceMaker
Solenoid valve
- Undo marked screw (see Fig. 5.2.7/ 1).
- Remove cover.
- Detach electrical connectors.
- Undo screw fitting of water hose.
Screw fitting of water hose
Double solenoid valve
Fig. 5.2.7 / 2
Electrical connection
Page 15/21