Environ™ Flex Rolls MUST NEVER BE CUT OR TRIMMED

TO FIT INTO A SPACE THAT IS TOO SMALL FOR THE ROLL SIZE

Smooth out the roll and adhere the roll to the underlayment with adhesive tape or aluminum tape strips.

After deciding the route that your power supply cables will take from the roll to the point of supply, cut a

¼” (6 mm) wide channel in the underlayment along this route and drop the power supply cables into this channel (See Figure 1). Similarly you have to cut a small section / channel in underlayment or laminate depending on the position of thermostat floor sensor. You may also need to remove a small section of underlayment from under the roll at the point where the power supply cord enters the roll, to prevent excessive wear on that part of the roll.

When installing two or more Environ™ Flex Rolls next to each other, make sure that the heating wires in adjacent rolls do not overlap. We recommend the use of adhesive tape to assure that they will not overlap over a period of time.

Environ™ Flex Rolls must be fit directly on top of the underlayment, and directly under the flooring.

To avoid damage to your rolls during installation, care must be taken so that tools with sharp edges or points are not dropped or used carelessly on top of the rolls. Do not walk on the rolls more than is absolutely necessary during installation, and do not drop or place heavy materials on the rolls.

Environ™ Flex Rolls must not be folded, and care should be taken in order to not fold or crease the rolls at any time during installation. For this reason Environ™ Flex Rolls are not suitable for use on stairs.

Should you wish to move your roll(s) at some later stage, please remember to roll it rather than folding it.

Note: These installation instructions are NOT intended to replace or supersede the installation instructions provided by the manufacturer of the wood laminate, but to supplement them.

You should comply with BOTH sets (floor covering and floor heating) of installation instructions.

In the event of any apparent contradiction between the Environ™ Flex instructions and the floor covering manufacturer’s instructions, kindly contact WarmlyYours for clarity on how to proceed, (800) 875-5285.

NOTE: A qualified, licensed electrician in accordance with local building and electrical codes, and the National Electric Codes, Canadian Electric Codes, and local codes, especially Article 424, Part

IX of the NEC, ANSI/NFPA 70 and Section 62 of CEC Part I, must do all electrical work.

Channel

Sensor

Figure 1

POLYMER-MODIFIED

THIN SET MORTER

CERAZORB

CERAMIC TILE

GROUT

IMPACTA T-700

BOND COAT ADHESIVE

OR LATEX MODIFIED THIN SET