advertisement
Identification of parts
Indoor unit
Air in take
B unit
Air outlet
Air intake
A2 unit
A ir outlet
2
1
3
10
A1 unit
4
5 7
9
Outdoor unit
6
On e-two /three type
LED Display panel
Signal receptor
AUTO TIMER DEF.
1 22
3
( 1)
4
Signal receptor
T IMER
AUTO
FREQ UENCY
5
OPERAT ION
DEFROS T
( 2)
OPERATING INSTRUCTIONS
IMPORTANT:
For multi-split type air conditioner, one outdoor unit can match different types of indoor units.
So all the pictures in this manual are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall prevail.
The following pages introduce several kinds of indoor units matching with the outdoor units.
Indoor unit
1. Front panel
2. Top air intake
3. Air filter(Inside)
4. Air outlet
5.
Horizontal air flow louver
6.
Vertical air flow louver(Internal)
7. Display panel
8. LED display window
9. Remote controller
10. Manual control button(Behind the front panel)
Outdoor unit
11. Refrigerant connecting pipe, drain hose and electric wiring
12. Stop valve
13. Air outlet
Display panel
AUTO indication lamp
Lights up during the Auto operation.
TIMER indication lamp
Lights up during Timer operation.
DEFROST indication lamp
(For Cooling & Heating models only):
Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation.
DIGITAL DISPLAY indication lamp
Displays the current setting temperature. Only when the air conditioner is in FAN operation, it displays the actual room temperature. And d isplays the malfunction code or protection code.
.
OPERATION indication lamp
This indicator appears only when the compressor is in operation and indicates the current operating frequency.
5
OPERATING INSTRUCTIONS
Identification of parts
Indoor unit
One-four
One-three
One-twin
Outdoor unit
9
DISPLAY PANEL
Infrared signal recepto r
OPERATION AUTO
TIMER
(1)
TIMER OPERATION
PRE-DEF
PRE-DEF
Infrared signal receptor
(2)
Indoor unit
1
Front panel frame
2
3
4
5
6
7
8
9
Front panel
Air filter
Horizontal air flow grille
Vertical air flow louver
Room temperature sensor
Display panel
Infrared signal receiver
Remote controller
Outdoor unit
10
Drain hose, refrigerant connecting pipe
11
12
Connective cable
Stop valve
13
Fan hood
DISPLAY PANEL
OPERATION indicator:
The indicator flashes once every second after power is on and illuminates when the air conditioner is in operation.
TIMER indicator:
The indicator illuminates when TIMER is set ON.
PRE-DEF. Indicator
model only):
(For cooling& heating
This indicator illuminates when the air conditioner starts defrosting automatically or when the Anticold air function is activated in heating operation.
AUTO indicator:
This indicator flashes when the air conditioner is in AUTO operation.
6
Identification of parts
Indoor unit
One-four
One-three
Outdoor unit
12
One-twin
LED Display window
1
22
3
(1)
4
8
5
10
11
9
Indoor unit
1
Front panel frame
2
3
4
5
6
7
8
Front panel
Air filter
Horizontal air flow grille
Vertical air flow louver
Room temperature sensor
Display panel
Remote controller
Outdoor unit
9
Drain hose, refrigerant connecting pipe
10
11
Connective cable
Stop valve
12
Fan hood
LED DISPLAY WINDOW
1
AUTO indication lamp
Lights up during the Auto operation.
22
TIMER indication lamp
Lights up during Timer operation.
3
4
DEFROST indication lamp
(For Cooling & Heating models only):
Lights up when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation.
DIGITAL DISPLAY indication lamp
Displays the current setting temperature. Only when the air conditioner is in FAN operation, it displays the actual room temperature. And d isplays the malfunction code or protection code.
5
OPERATION indication lamp
This indicator appears only when the compressor is in operation and indicates the current operating frequency.
(2)
7
OPERATING INSTRUCTIONS
Identification of parts
Indoor unit
O ne-fo ur
O ne-thre e
Indoor unit
1. Panel frame
2. Rear air intake grille
3. Front panel
4. Air Purifying filter & Air filter(behind)
5. Horizontal louver
6. LCD display window
7. Vertical louver
8. Manual control button(behind)
9.
Remote controller holder
O ne-twin
Outdoor unit
10. Drain hose, refrigerant connecting pipe
11. Connective cable
12. Stop valve
13. Fan hood
Outdoor unit
13
9
11
12
10
8
Display window
NOTE: The display window on the air
conditioner you purchased may look like one of the following:
Signal receptor
(1)
(2)
(3)
(4) auto timer defrost ion
(5)
OPERATING INSTRUCTIONS
OPERATION display
Displayed when the air conditioner is in operation.
AUTO operation display
Displayed during Auto operation.
DEFROST operation display
(For Heating & Cooling model only):
Displayed when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation.
TIMER display
Displayed during Timer operation.
Ion
CLEAN AIR display(optional)
Displayed when CLEAN AIR feature is activated.
TURBO operation display
Displayed when select TURBO function on cooling operation or on heating operation.
DIGITAL DISPLAY
Displays the current setting temperature when the air conditioner is in operation.
FAN SPEED display
Displayed the selected fan speed:
LOW( ), MED( ) and
HIGH( ).
Frequency indication lamp
This display is separated into five zones.
The zones illuminate based on the compressor current frequency. For example, higher frequency will illuminate more zones.
9
OPERATING INSTRUCTIONS
Identification of parts
Floor and standing type(console)
Indoor unit
1
4
5
2
6
1
3
10
Display panel
Infrared signal receiver
9
8
7
Indoor unit
1. Air flow louver (at air outlet)
2. Air inlet(with air filter in it)
3. Remote controller
4. Installation part
5. Display panel
6. Connecting pipe
Outdoor unit
7. Drain hose, refrigerant connecting pipe
8. Connective cable
9. Stop valve
10. Fan hood
3
22
1
DISPLAY PANEL:
OPERATION indication lamp
This indicator illuminates when the unit is operational.
TIMER indication lamp
Lights up during Timer operation.
4
DEFROST indication lamp
models only)
(Cooling & Heating
or Fan only indication lamp
(Cooling only type)
:
Lights up when the air conditioner starts defrosting automatically in heating operation or fan only mode is selected.
Temporary button
This button is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted. One press of the manual control button will lead to the forced
AUTO operation. If press the button twice within five seconds, the unit will operate under forced
COOL operation. The forced COOL operation is used for testing purposes only, please do not choose it unless it is necessary.
3
1
2
4
10
OPERATING INSTRUCTIONS
Identification of parts
Floor and standing type(console)
Indoor unit
7
Indoor unit
1. Indoor unit
2. Air flow louver (at air outlet)
3. Installation part
4. Air out
5. Air inlet(with air filter in it)
6. Air in
7. Remote controller
Outdoor unit
8. Drain hose, refrigerant connecting pipe
9. Connective cable
10. Stop valve
11. Fan hood
11
8
9
10
Display panel
NOTE: The display window on the air
conditioner you purchased may look like one of the following:
2
1
3
4
5
Infra red signal receiver
(1)
1
DISPLAY PANEL:
OPERATION indication lamp
This indicator illuminates when the unit is operational.
22
TIMER indication lamp
Lights up during Timer operation.
3
DEF./FAN indication lamp
Lights up when the air conditioner starts defrosting automatically in heating operation
(applicable to cooling & heating models only) or fan only mode is selected(applicable to cooling only models).
4
AlARM indication lamp
Flashes when malfunction occurs.
11
OPERATING INSTRUCTIONS
2
1
3
4
5
Infrare d signal receiver
(2)
Infrared signal rec eiver
6
5
Temporary button
This button is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted. One press of the manual control button will lead to the forced
AUTO operation. If press the button twice within five seconds, the unit will operate under forced COOL operation.
The forced COOL operation is used for testing purposes only, please do not choose it unless it is necessary.
Temperature Display
Displays the current setting temperature while the unit is operating.
4
3
(3)
5
2
1
6 3
4
Infrared signa l rece iver
1
(4)
2
5
5 1 2 3 4 6
Infrared signal receiver
(5)
12
Identification of parts
Duct / C eiling t ype
Indoor unit
10
Display panel
MANUAL OPERATION TIMER DEF./FAN ALARM
Infrared signal receiver
Digital display window
9
7
8
OPERATING INSTRUCTIONS
Indoor unit
1. Air outlet
2. Air inlet
3. Air filter
4. Electric control cabinet
5. Wire controller
6. Drain pipe
Outdoor unit
7. Drain hose, refrigerant connecting pipe
8. Connective cable
9. Stop valve
10. Fan hood
1
DISPLAY PANEL:
OPERATION indication lamp
This indicator illuminates when the unit is operational.
22
TIMER indication lamp
Lights up during Timer operation.
3
DEF./FAN indication lamp
Lights up when the air conditioner starts defrosting automatically in heating operation
(applicable to cooling & heating models only) or fan only mode is selected(applicable to cooling only models).
5
4
AlARM indication lamp
Flashes when malfunction occurs.
MANUAL button
This button is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted. One press of the manual control button will lead to the forced AUTO operation. If press the button twice within five seconds, the unit will operate under forced COOL operation. The forced
COOL operation is used for testing purposes only, please do not choose it unless it is necessary.
13
OPERATING INSTRUCTIONS
Identification of parts
Duct type
Indoor unit
4
8
1
Display panel
7
5
6
Indoor unit
1. Air outlet
2. Air inlet
3. Air filter
4. Remote controller
Outdoor unit
5. Drain hose, refrigerant connecting pipe
6. Connective cable
7. Stop valve
8. Fan hood
1
DISPLAY PANEL:
OPERATION lamp
This indicator illuminates when the unit is operational.
22
TIMER indication lamp
Lights up during Timer operation.
3
PRE-DEF./FAN indication lamp
Lights up when the air conditioner starts defrosting automatically in heating operation
(applicable to cooling & heating models only) or fan only mode is selected(applicable to cooling only models).
5
4
AlARM indication lamp
Flashes when malfunction occurs.
TEMPORARY button
This button is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted. One press of the manual control button will lead to the forced AUTO operation. If press the button twice within five seconds, the unit will operate under forced COOL operation. The forced
COOL operation is used for testing purposes only, please do not choose it unless it is necessary.
14