General Specifications
Maximum voltage between any
terminal and earth ground ........................................... 1000 V rms
W
Fuse for A inputs ..................................................... 11 A, 1000 V 17000A interrupt rating Fuse
Display ........................................................................... 6000 counts, updates 4/sec (Frequency: 9,999 counts, Capacitance: 1,000 counts)
Altitude
Operating .................................................................... 2,000 meters
Storage ....................................................................... 12,000 meters
Temperature
Operating .................................................................... -10
°
C to +50
°
C
Storage ....................................................................... -40
°
C to +60
°
C
Temperature coefficient ............................................... 0.1 X (specified accuracy) /
°
C (< 18
°
C or > 28
°
C)
Electromagnetic Compatibility (EN 61326-1:2006) .... In an RF field of 3 V/m, accuracy = specified accuracy except in temperature: specified accuracy
±
5
°
C (9
°
F)
Wireless Frequency ...................................................... 2.4 GHz ISM Band 10 meter range
Relative Humidity.......................................................... Maximum noncondensing
90 % at 35
°
C
75 % at 40
°
C
45 % at 50
°
C
0 % to 70 % for 40 M
Ω
range
Battery Type
Meter base.................................................................. Three AA Alkaline batteries, NEDA 15A IEC LR6
Display module ........................................................... Two AA Alkaline batteries, NEDA 15A IEC LR6
Battery Life .................................................................... 400 hrs typical (Alkaline)
Shock ............................................................................. 1 Meter drop 6 sides per IEC 61010
Size (H x W x L) ............................................................. 5.3 cm x 9.3 cm x 19.3 cm
38
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 233 Users Manual
- 2 Warranty
- 3 Table of Contents
- 7 List of Tables
- 9 List of Figures
- 11 Introduction
- 11 How to Contact Fluke
- 12 Safety Information
- 12 Warnings and Cautions
- 15 Radio Frequency Data
- 16 Hazardous Voltage
- 16 Test Lead Alert
- 18 Features
- 22 Error Messages
- 23 Battery Saver™(Sleep Mode)
- 23 MIN MAX AVG Record Mode
- 24 Display Hold
- 24 Manual and Autoranging
- 25 Backlight
- 25 Power-Up Options
- 26 How to Make Measurements
- 26 AC and DC Voltage Measurements
- 27 Resistance Measurements
- 29 Temperature Measurements
- 29 Continuity Tests
- 31 Diode Tests
- 33 Capacitance Measurements
- 34 AC and DC Current Measurements
- 36 Frequency Measurements
- 36 Remote Operation
- 37 Remove the Display Module
- 38 Dock the Display Module with the Meter base
- 39 Maintenance
- 39 General Maintenance
- 39 Battery Replacement
- 43 Fuse Test
- 44 Fuse Replacement
- 45 Service and Parts
- 48 General Specifications
- 49 Detailed Specifications
- 49 AC Voltage
- 50 DC Voltage, Conductance, and Resistance
- 50 Continuity
- 50 Temperature
- 51 AC Current
- 51 DC Current
- 52 Capacitance
- 52 Diode
- 53 Frequency
- 53 MIN MAX Recording
- 54 Input Characteristics