Installation. Nordson MEG® Gun Driver, MEG Gun Driver
Add to my manuals20 Pages
Nordson MEG® Gun Driver is a high-performance electrostatic gun driver designed to provide precise control over spray patterns and minimize material consumption. It features advanced digital technology that enables users to adjust spray parameters, store multiple programs, and monitor performance in real-time. The MEG Driver is compatible with a wide range of Nordson electrostatic spray guns, making it a versatile solution for various applications, including automotive, aerospace, and general industrial.
advertisement
8
MEG r
Driver
Installation
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related documentation.
Unpacking
Mounting
CAUTION: Care should be taken to avoid damage to the MEG driver during unpacking.
No special instructions are necessary to unpack the MEG driver.
1. There are two MEG driver models—single-channel and dual-channel.
Compare the part number on the nameplate with the driver part numbers in the Parts section to make sure you have the right model.
2. Inspect the driver enclosure for dents and other physical damage.
Contact a Nordson representative if any damage is found.
1. Position the MEG driver (1) in a vertical position as shown.
2. Snap the DIN rail clips (2) on the rear panel into the DIN rail (3).
Part 229776B
1
2
3
Figure 2 Typical Mounting
1. MEG driver
2. DIN rail clips
3. DIN rail
E 2001 Nordson Corporation
MEG r
Driver
9
Electrical Connections
Wiring Requirements
NOTE: Use 18AWG shielded wire such as Belden #8770 for the driver-to-gun electrical connections. Use 16−18 AWG wire rated for at least
250 volts for the driver power connections. At a minimum, this wire must be suitable for 10 _C (50 _F) above the surrounding ambient temperature.
All driver wiring is connected to an 18-station terminal connector plugged into the receptacle on the backplane.
AC Input Power
1. Connect the power supply line wires to L1 and L2.
2. Connect the ground wire to the power input ground.
Trigger Signals
NOTE: Check for proper polarity when connecting trigger signal wires.
1. Connect the trigger input wires from the timer(s) to the TRIG 1
CHANNEL 1 (and TRIG 2 CHANNEL 2, if used) terminals:
S
For +15−48 Vdc trigger voltages, connect the input wires to + HI and
COM.
S
For 3−7 Vdc trigger voltage, connect the input wires to + L0 and
COM.
Spray Gun Connections
The spray gun coil connections are not polarity sensitive. Connect the MEG driver to the spray gun(s) as shown in the wiring diagram. Refer to your spray gun manual for wiring and fusing requirements.
E 2001 Nordson Corporation
Part 229776B
10
MEG r
Driver
Figure 3 Electrical Connections
GUN1
GND
SHLD
+HI
+LO
COM
GUN2
GUN2
GND
SHLD
GND
L2
L1
N/C
+HI
+LO
COM
GUN1
Ground
AC Wiring (100−240 Vac)
Timer 1 Input
Gun 1
Timer 2 Input
Gun 2
Part 229776B
E 2001 Nordson Corporation
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 Safety
- 5 Qualified Personnel
- 5 Intended Use
- 5 Regulations and Approvals
- 6 Personal Safety
- 6 High‐Pressure Fluids
- 8 Fire Safety
- 9 Halogenated Hydrocarbon Solvent Hazards
- 9 Action in the Event of a Malfunction
- 9 Disposal
- 10 Description
- 11 Features
- 11 Specifications
- 12 Installation
- 12 Unpacking
- 12 Mounting
- 13 Electrical Connections
- 13 Wiring Requirements
- 13 AC Input Power
- 13 Trigger Signals
- 13 Spray Gun Connections
- 15 Operation
- 15 Troubleshooting
- 16 Repair
- 18 Parts
- 18 Using the Illustrated Parts List
- 19 MEG Driver Parts
- 20 Recommended Spare Parts