Operational Input Voltage Range
(V rms)
100-127V and 200-240V
Frequency Range (Nominal) (Hz)
47 to 63 (50/60)
Nominal Input Voltage (Vrms)
Max Rated Output Wattage Rating
Nominal Input Current (A rms)
Max Rated Input Wattage Rating
(Watts)
Max. Rated VA (Volt-Amp)
Efficiency (%)
Power Factor
Leakage Current (mA)
Maximum Inrush Current (A peak)
Maximum Inrush Current duration
(mS)
100
300
4.7
462
471
65
0.31
63
115
300
4.0
455
464
66
0.36
72
208
300
2.2
448
457
67
0.65
130
0.98
20
220
300
2.0
441
450
68
0.69
138
230
300
1.9
435
444
69
0.72
144
240
300
1.8
429
437
70
0.75
150
System Specifications
ML330 G2 Fully Configured
Up to 2 Processors, 4 Memory Slots, 5 Hard Drives, 5 PCI Slots, and 1 Hot Plug Power Supply
Nominal Input Voltage (Vrms)
Fully Loaded System Input Wattage
(W)
Fully Loaded System Input Current
(A rms)
Fully Loaded System Thermal (BTU-
Hr)
Fully Loaded System VA (Volt-Amp)
System Leakage with all power supplies loaded (mA)
100
317
3.2
1081
323
0.31
115
312
2.8
1064
318
0.36
System Inrush Current with all power supplies loaded (A)
Power cord requirements
63 72
Nema 5-15P to IEC320-C13
208
307
1.5
1048
314
0.65
130
220
303
1.4
1033
309
0.69
138
IEC320-C13 to IEC320-C14
230
299
1.3
1018
305
0.72
144
240
294
1.3
1003
300
0.75
150
Option no./Spare no.: See Power Cord chart
Option no./Spare no.: 142259-
001/142258-B21
DA - 10961 Worldwide QuickSpecs — Version 40 — 12.5.2003
Page 37
QuickSpecs
Compaq ProLiant ML330 Generation 2
Power Specifications
Example of real input watts consumed versus rated watts consumed is available via the online tool located at url: http://inline.compaq.com/pg/ecg/issd/power/psupply.asp
. Select system calculator for one of the systems and reference the green fields at the bottom of the calculator.
NOTES:
* To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at
URL: http://h30099.www3.hp.com/configurator/powercalcs.asp
.
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: ML330 G2
- Click on: "Power Calculator" link (You may need to scroll down to see it.)
Power Cords (13 Cord Sets)
Country
APD
APD
APD
Australia
Europe
France
Germany
Japan
PRC
PRC
PRC
UK
US
Power Cord Part Number
139867-006
100613-003
100614-003
100611-007
100614-003
100614-003
100614-003
139867-006
139867-006
100613-003
100661-007
100613-003
163719-002
DA - 10961 Worldwide QuickSpecs — Version 40 — 12.5.2003
Page 38
advertisement
Related manuals
advertisement
Table of contents
- 1 Overview
- 3 Standard Features
- 8 Models
- 9 Options
- 33 Memory
- 34 Storage
- 37 Power Specifications
- 39 TechSpecs