V371_E.indb 115
8B. Service – To be conducted by a technician only –
(b) When the indicator indicates a value higher than specified value
Pull up the knob and turn it to the left as shown in Figure (b) until the indicator indicates 0 MPa, and turn the knob to the right until the indicator indicates a value between 0.35 and 0.40 MPa. Then, lower the knob until a clicking sound is produced.
* If the pressure is set to a level higher than the specified value, reduce the pressure to 0 MPa first and then adjust. If the pressure is adjusted by turn ing the knob to the left, the pressure level may change after a while.
When pressure is higher than specified value
Pressure decreases.
Pressure increases.
Unlock
Lock
Knob
Decrease the pressure to 0 MPa and then increase it.
Reinstall the filter regulator cover and filter compartment door by following the removal sequences described in and in reverse.
(4) Confirmation of the compressor pressure and compressor startup time
Turn off the power switch (see P.101 “8A-1-6 Power switch location and turning on the switch”) to release compressed air and water from the compressor.
Using the provided service key, open the filter compartment door and check the compressor pressure. Pressure should be 0.7 MPa or higher.
* If the compressor pressure is lower than 0.7 MPa or the compressor does not stop, turn off the power switch (see P. 101 “8A-1-6 Power switch location and turning on the switch”) and check the air tube connection (see P. 96 “8A-1-3
Connecting the Front Assy to the Ride Assy, and adjusting level adjusters”).
* If the air tube is securely connected but the compressor does not operate properly, contact your distributor.
Front side of Monitor Assy
Filter regulator pressure setting
Compressor meter
115
2010/03/31 17:39:30