Pentax MD-20
Manuals and User Guides for Pentax MD-20. We found 1 manuals for free downloads instruction manual
Below you will find brief information for Electronic Distance Meter MD-14, Electronic Distance Meter MD-20. These Electronic Distance Meters offer a range of features for precise distance measurement and data collection. They can measure slope distance, horizontal distance, and vertical distance, as well as provide coordinate measurements. The instruments also feature atmospheric correction, prism offset correction, averaging function, and stake-out function. They can be used with a Pentax Electronic Theodolite for automated angle input and coordinate measurements. The MD-14 and MD-20 are ideal for a variety of surveying and construction applications.
Key Features
Slope distance, horizontal distance, and vertical distance measurement
Coordinate measurements
Atmospheric correction
Prism offset correction
Averaging function
Stake-out function
Remote elevation measurement (REM)
Missing line measurement
Automatic angle input from Pentax Electronic Theodolite
Data communication with data collector (DC-1)
Pages: 32 Pentax MD-20 instruction manual
Brand: Pentax Category: Measuring, testing & control Size: 846 KB
Languages: English
Open manualFrequently Answers and Questions
How do I measure the distance between two points using the missing line measurement mode?
To measure the distance between two points using the missing line measurement mode, you need to set a reflecting prism at each point. Then, collimate on the first target and enter the vertical and horizontal angles. Next, measure the slope distance to the first target. After that, collimate on the second target, enter the vertical and horizontal angles, and measure the slope distance to the second target. The horizontal distance and difference in height between the two points will then be displayed.
How do I use the REM mode to measure the height of a power transmission line?
To use the REM mode to measure the height of a power transmission line, you need to set the reflecting prism directly below the target object and measure the distance from the ground to the reflecting prism center with a tape. Then, enter the ground to prism height and the vertical angle to the target.
How do I set the prism constant?
The prism constant can be set anywhere from -99 to +99mm. To change the prism constant setting, use the internal switch.
How do I use the stake-out measurements feature?
To use the stake-out measurements feature, first enter the set distance. After that, measure the distance to the target. The difference between the measured value and the set value will be displayed.
How do I input the temperature and pressure?
The temperature and pressure are initially set to a standard 15°C, 760 mmHg. You can input the temperature and pressure by pressing the T/P/BAT key.
advertisement