Agilent
PNA Family
Microwave Network Analyzers
Configuration Guide
PNA-X N5241A
PNA-X N5242A
PNA-X N5244A
PNA-X N5245A
PNA E8362C
PNA E8363C
PNA E8364C
PNA E8361C
PNA N5250C
PNA-L N5230C
10 MHz to 13.5 GHz
10 MHz to 26.5 GHz
10 MHz to 43.5 GHz
10 MHz to 50 GHz
10 MHz to 20 GHz
10 MHz to 40 GHz
10 MHz to 50 GHz
10 MHz to 67 GHz
10 MHz to 110 GHz
300 kHz to 6, 13.5, or 20 GHz,
10 MHz to 20, 40, or 50 GHz
This configuration guide describes standard configurations, options, accessories, upgrade kits and compatible peripherals for the PNA family microwave network analyzers. This guide should be used with the Agilent PNA family data sheets for a complete description of these analyzers.
2
Table of Contents
PNA-X Series Network Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
PNA-X Noise Figure Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Test set and power confi guration options . . . . . . . . . . . . . . . . . . . . . . . . 7, 8
Measurement applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9, 10
Nonlinear vector network analysis . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Pulse, antenna, millimeter-wave . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Upgrade kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12, 13
PNA Series Network Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Test set and power confi guration options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Measurement applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Pulse, antenna, millimeter-wave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Confi guration details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Simplifi ed test set block diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-21
N5250C millimeter-wave system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 23
Upgrade kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
PNA-L Series Network Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Test set and power confi guration options . . . . . . . . . . . . . . . . . . . . . . . . . 26
Measurement applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Upgrade kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Measurement Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Calibration kits, cables, adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
For devices with 1.0 mm connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
For devices with 1.85 mm connectors . . . . . . . . . . . . . . . . . . . . . . . . . . 30
For devices with 2.4 mm connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
For devices with K (2.92 mm) connectors . . . . . . . . . . . . . . . . . . . . . . . . . 31
For devices with 3.5 mm or SMA connectors . . . . . . . . . . . . . . . . . . . . . 33, 34
For devices with Type-N connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
For devices with 7 mm connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
For devices with waveguide . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35, 36
Verifi cation kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
General Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Hard drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Power meters and sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Amplifi ers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Couplers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Equipment rack accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Printers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Interface cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Agilent offers the following options for all PNA family network analyzers
Certification options
□
Commercial calibration certification with test data (Option UK6)
Complete set of measurements which tests unit to manufacturer’s published specifications. Includes calibration label, calibration certificate, and data report. Conforms to ISO 9001.
Documentation
The PNA Series instruments are equipped with an Online Help system available within the instrument in the following languages:
English, Japanese, Chinese, German, Spanish, and French. Service guides and the Online Help system are available on the web: www.na.tm.agilent.com/pna
□
ISO 17025 compliant calibration (Option 1A7)
Complete set of measurements which tests unit to manufacturer’s published specifications. Includes calibration label, ISO 17025 calibration certificate, and data report, measurement uncertainties and guardbands on all customer specifications. Conforms to ISO
17025 and ISO 9001.
Calibration Software Licenses
□
Perpetual license for built-in performance test software for
Agilent inclusive cal (Option 897)
Adds built-in performance testing and calibration software for self-maintainers. Requires additional equipment. See the analyzer’s
Service Guide for more information on equipment required.
□
ANSI Z540 compliant calibration (Option A6J)
Complete set of measurements which tests unit to manufacturer’s published specifications. Includes pre- and post-adjustment data with measurement uncertainty information compliant to the
ANSI/NCSL Z540 standard.
□
Perpetual license for built-in performance test software for
Standards compliant cal (Option 898)
Adds built-in performance testing and calibration software for self-maintainers. Requires additional equipment. See the analyzer’s
Service Guide for more information on equipment required.
Warranty and service
1-, 3-, and 5-year warranty and service plans are available at the time of instrument purchase. Standard warranty is 1 year.
3
4
PNA-X Series Network Analyzer
N5241A
N5242A
10 MHz to 13.5 GHz
10 MHz to 26.5 GHz
N5244A
N5245A
10 MHz to 43.5 GHz
10 MHz to 50 GHz
Option configurations
To add options to a product, order the corresponding item number.
Description For N5241A For N5242A
Test set
Option 200 2-ports, single source
Option 224 2-ports, add internal
2nd source, combiner
N5241A-200 N5242A-200
N5241A-224 N5242A-224
Option 400 and mechanical switches
4-ports, dual source N5241A-400 N5242A-400
Option 423 4-ports, add internal combiner N5241A-423 N5242A-423 and mechanical switches
For N5244A
N5244A-200
N5244A-224
For N5245A Additional information
N5245A-200
N5245A-224 Requires Options 200, one of 219 or
H85, and 080
N5244A-400
N5244A-423
N5245A-400 Option 080 recommended
N5245A-423 Requires Options 400, one of 419 or
H85, and 080
Power configuration
Option 219 2-ports, extended power range and bias-tees
N5241A-219 N5242A-219 N5244A-219 N5245A-219 Requires Option 200
Option 419 4-ports, extended power range N5241A-419 and bias-tees
Option H851 High power configurable
N5242A-419 N5244A-419 N5245A-419 Requires Option 400,
Option 080 recommended
N5241AS-H85 N5242AS-H85 N5244AS-H85 N5245A-H85 Requires Option 200 for 2-port,
(for 2- or 4-port)
Measurement applications
Option 400 for 4-port
Option 010 Time-domain measurements N5241A-010 N5242A-010
Option 028 2 Noise figure measurements
N5244A-010 N5245A-010
N5241A-028 N5242A-028 N5244A-028 N5245A-028 Requires Option 080
Option 029
Option H29
2
2 using standard receivers
Fully-corrected noise figure measurements
Add 26.5 GHz noise receivers
N5241A-029 N5242A-029
N/A N/A
Option 080 Frequency offset
Option 082
3
Scalar-calibrated converter
N5241A-080
N5241A-082
N5242A-080
N5242A-082
Option 083 3 measurements
Vector- and scalar-calibrated N5241A-083 N5242A-083
N/A
N5244A-083
N/A
N5245A-083
Requires one of Options 219, 224
419, 423, or H85, and Option 080
N5244AS-H29 N5245AS-H29 Requires Option 423
N5244A-080
N5244A-082
N5245A-080
N5245A-082 Requires Option 080
Requires Option 080 converter measurements
Option 084 Embedded LO measurements N5241A-084 N5242A-084
Option 086 Gain compression application N5241A-086 N5242A-086
Option 087 Intermodulation distortion application
N5241A-087 N5242A-087
Option 460 Integrated true-mode stimulus N5241A-460 N5242A-460 application
Option 551
4
N5244A-084
N5244A-086
N5244A-087
N5244A-460
N5245A-084
N5245A-460
Requires at least one of Options
028, 029, H29, 082, 083, or 087
N5245A-086 Options 219, 419 or H85 recommended
N5245A-087 Requires Options 224 or 423
Requires Option 400
Nonlinear vector network analysis
Option 510 Nonlinear component characterization
Option 514 Nonlinear X-parameters
5
Option 518 Nonlinear pulse envelope domain
Option 520 Arbitrary load-impedance
X-parameters
N5241A-510
N5241A-514
N5241A-518
N5241A-520
N5242A-510
N5242A-514
N5242A-518
N5242A-520
N5244A-510
N5244A-514
N5244A-518
N5244A-520
N5245A-510 Requires Options 419 and 080, or
400, H85 and 080
N5245A-514 Requires Options 423 and 510
N5245A-518 Requires Options 021 and 025
N5245A-520 and either one of 510 or 514
Requires Option 514
Required NVNA accessories
• U9391C 10 MHz to 26.5 GHz or U9391F 10 MHz to 50 GHz comb generator (two required for nonlinear measurements)
• Agilent power meter and sensor or USB power sensor
• Agilent signal generator, MXG or PSG used for X-parameter extraction (internal 10 MHz reference output can be used for 10 MHz tone spacing applications)
1. Order special model N524xAS instead of N524xA and add items N524xA-200 and N524xAS-H85 for 2-port, extended power range, high power configuration,
or items N524xA-400 and N524xAS-H85 for 4-port, extended power range, high power configuration. Order N524xA-xxx items for other standard options.
Option H85 modifies the extended power range and bias-tees (Options 219 and 419), and therefore, they cannot be ordered together.
2. For source-corrected measurements, Options 028, 029, and H29 require an ECal module for use as an impedance tuner. For calibration, Options 029 and
H29 also require a 346-series noise source (Agilent 346C recommended), while Option 028 requires a power meter. All options require a power meter for
measuring mixers and converters.
3. Option 082 is a subset of Option 083; therefore, they cannot be ordered together.
4. When configured as a multiport analyzer using Option 551 and a multiport test set, the combiner feature of Option 224 or 423 is temporarily disabled.
When configured as a standalone analyzer, the combiner feature is enabled. When ordering a test set, select an option to specify the appropriate
interconnect jumper cable set between the analyzer and the test set.
5. X-parameters is a trademark of Agilent Technologies
PNA-X Series Network Analyzer
Option configurations (continued)
To add options to a product, order the corresponding item number.
Description
Pulse, antenna, mm-wave
For N5241A For N5242A For N5244A For N5245A Additional information
Option 020 Add IF inputs for antenna and mm-wave
Option 021 Add pulse modulator to internal 1st source
Option 022 Add pulse modulator to internal 2nd source
Option 025 Add four internal pulse generators
N5241A-020
N5241A-021
N5241A-022
N5241A-025
N5242A-020
N5242A-021
N5242A-022
N5242A-025
N5244A-020
N5244A-021
N5244A-022
N5244A-025
N5245A-020
N5245A-021
N5245A-022
N5245A-025
Option 118 Fast CW sweep
Accessories
Option 1CM Rack mount kit for use without handles
N5241A-118
N5241A-1CM
N5242A-118
N5242A-1CM
N1966A
N4688A
Pulse I/O adapter
USB CD R/W drive
N1966A
N4688A
N1966A
N4688A
Calibration software
Option 897
1
Perpetual license for built-in N5241A-897 N5242A-897 performance test software for
Option 898
1
Agilent inclusive calibration
Perpetual license for built-in N5241A-898 N5242A-898 performance test software for standards compliant calibration
N5244A-118
N5244A-1CM
N1966A
N4688A
N5244A-897
N5244A-898
N5245A-118
N5245A-1CM
N1966A
N4688A
N5245A-897
N5245A-898
Requires Option 224 or 400
Calibration documentation
Option 1A7 ISO 17025 compliant calibration N5241A-1A7 N5242A-1A7 N5244A-1A7 N5245A-1A7 with test data
Option A6J ANSI Z540 compliant calibration N5241A-A6J N5242A-A6J N5244A-A6J N5245A-A6J
1. Additional hardware required. Please refer to the analyzer’s Service Guide for required service test equipment.
5
PNA-X Series Network Analyzer
The PNA-X is an integrated vector network analyzer featuring a built-in S-parameter test set, one or two synthesized sources used for device stimulus, a hard disk drive, USB interfaces, and a
10.4” LCD touch screen display. The N5241A and the N5242A have 50 ohm, ruggedized 3.5 mm (m) test ports. The N5244A and the N5245A have 50 ohm, ruggedized 2.4 mm (m) test ports.
Included with each instrument is a mouse, keyboard (U.S. style), and a 1-year return-to-Agilent service warranty.
Test set and power configuration options
• 2-port standard test set and power range (Option 200)
The standard 2-port test set comes with six front-panel access
loops. The loops provide access to the signal path between
(a) the source output and the reference receiver, (b) the source
output and directional coupler thru arm and (c) the coupled
arm of the directional coupler and the port receiver. The standard
test set also includes a solid-state internal RF transfer switch
in the R1 reference-receiver path.
OUT 1
Source 1
OUT 2
• Extended power range and bias-tees (Option 219, 419)
Adds to the standard test set one 65 dB for N5241A/42A
and 60 dB for N5244A/45A source attenuator (settable in 5 dB
increments for N5241A/42A and 10 dB increments for
N5244A/45A), one 35 dB receiver attenuator (settable in 5 dB
increments), and one bias-tee to each test port. Option 219
requires Option 200, and Option 419 requires Option 400.
OUT 1
Source 1
OUT 2
R1
65 dB
Test port 1
A
35 dB
R2
65 dB
Test port 2
B
35 dB
R1
A
R2
B
Test port 1 Test port 2
• 4-port standard test set, power range and an internal second
source (Option 400)
The standard 4-port test set comes with 12 front-panel access
loops and a built-in second source. The loops provide access to
the signal path between (a) the source output and the reference
receiver, (b) the source output and directional coupler thru arm
and (c) the coupled arm of the directional coupler and the port
receiver. The internal second source provides an additional signal
(fixed or swept) for two-tone third-order-intercept (TOI) and
intermodulation testing of amplifiers, or it can be used as a fast
swept-LO signal for fixed-IF testing of mixers and converters.
With two sources, source 1 is accessible through test ports 1
and 2, and source 2 is accessible through test ports 3 and 4.
The standard test set also includes a solid-state internal RF
transfer switch in the R1 reference-receiver path. Recommends
OUT 1
Source 1
OUT 2
OUT 1
Source 2
OUT 2
R1
65 dB
Test port 1
R3
A
35 dB
65 dB
Test port 3
C
35 dB
R4
65 dB
Test port 4
R2
D
35 dB
65 dB
Test port 2
B
35 dB
R1
A
R3
OUT 1
Source 1
OUT 2
OUT 1
Source 2
OUT 2
C
R4
D
R2
B
Test port 1 Test port 3 Test port 4 Test port 2
PNA-X Series Network Analyzer
• Add an internal second source, a combiner and mechanical switches to 2-port analyzer (Option 224)
Available with 2-port model only, this option adds an internal second source, a combiner and mechanical switches. The internal second source provides an additional signal (fixed or swept) for two-tone third-order-intercept (TOI) and intermodulation testing of amplifiers, or it can be used as a fast swept-LO signal for fixed-IF testing of mixers and converters. The mechanical switches provide increased flexibility by having rear panel access to signal paths for advanced applications. Access to the second source is available through two output connectors on the front panel. Requires Options 200, 219 and 080.
rear panel
J11 J10 J9 J8 J7 J2 J1
• High-power test set (Model N524xAS Option H85)
With extended power range and bias-tees (Option 219, 419), the internal bias tees limit the maximum test port input power to +30 dBm. The high-power test set removes the bias tees between the source attenuators and the test port couplers. This extends the maximum port power that the analyzer can safely handle to +43 dBm. Selecting Option H85 adds internal attenuators and cables (Option 285 for 2-port or Option 485 for 4-port analyzers).
The high-power test set modifi es Options 219 and 419, and therefore, they can not be ordered together.
OUT 1
Source 1
OUT 2
OUT 1
Source 2
OUT 2
OUT 1
Source 2
OUT 2
OUT 1
Source 1
OUT 2
R1
Test port 1
A
Source 2
Output 1
Source 2
Output 2
R2
Test port 2
B
R1
65 dB
Test port 1
R3
A
35 dB
65 dB
Test port 3
R4
C
35 dB
65 dB
Test port 4
R2
D
35 dB
65 dB
Test port 2
B
35 dB
• Add an internal combiner and mechanical switches to 4-port analyzer (Option 423)
Available with 4-port model only, this option adds a combiner and mechanical switches. The mechanical switches provide increased flexibility by having rear panel access to signal paths for advanced applications. Requires Options 400, 419 and 080.
rear panel J11 J10 J9 J8 J7 J4 J3 J2 J1
OUT 1
Source 1
OUT 2
OUT 1
Source 2
(standard)
OUT 2
R1
A
R3
C
R4
D
R2
B
Test port 1 Test port 3 Test port 4 Test port 2
7
PNA-X Series Network Analyzer
Measurement applications
□
Time domain (Option 010)
This option enables the PNA-X to view reflection and
transmission responses in time or distance. Use time domain
to tune filters, gate out the response of fixtures and cables,
characterize the impedance of transmission lines and more.
□
Frequency offset (Option 080)
This option enables the PNA-X to set the source frequency
independently from where the receivers are tuned. This ability
is important for measuring amplifiers, mixers, and frequency
converters.
□
Scalar-calibrated converter measurements (Option 082)
With a simple setup and calibration, this application delivers
the highest accuracy for scalar conversion-loss/gain measure-
ments by combining one-port and power-meter calibrations to
remove mismatch errors. Option 082 provides an intuitive and
easy-to-use user interface for setting up mixer and converter
measurements, with single or dual conversion stages. It can
control the PNA-X’s built-in second source as well as external
signal generators for use as LO signals. Supported external
sources include the Agilent ESG, PSG, and MXG series, as
well as other SCPI-controlled signal generators. Option 082
requires Option 080, and cannot be ordered with Option 083.
It is compatible with Option 084, which enables measurements
of converters with internal LOs.
□
Vector- and scalar-calibrated converter measurements (Option 083)
This application includes the new scalar mixer/converter +
phase measurement class which provides fully calibrated con
version gain/loss, relative phase, and absolute group delay
measurements of mixers and converters without the need for
a reference mixer. A vector mixer/converter measurement
class is also included for measurements with the least
amount of trace noise for phase/delay measurements. Option
083 provides an intuitive and easy-to-use user interface for
setting up mixer and converter measurements, with single or
dual conversion stages. It can control the PNA-X’s built-in
second source as well as external signal generators for use as
LO signals. Supported external sources include the Agilent
ESG, PSG, and MXG series, as well as other SCPI-controlled
signal generators. Option 083 requires Option 080, and cannot
be ordered with Option 082. It is compatible with Option 084,
which enables measurements of converters with internal LOs.
□
Embedded LO measurements (Option 084)
This option tunes the PNA-X receivers to the output frequency
of the converter under test, without the need for access to
internal LOs or a common reference signal. For converters
with embedded LOs, this option enables measurements of
match-corrected conversion loss/gain (requires Option 082 or 083),
absolute group delay (requires Option 083), intermodulation dis-
tortion (requires Option 087), and noise figure (requires Option 028,
029, or H29).
8
□
Gain compression application (Option 086)
The Gain Compression Application (GCA) provides input power,
output power, gain, and phase at an amplifier's compression
point, over a specified frequency and power range. GCA's
SMART Sweep is very fast and easy-to-use. GCA also includes
a guided calibration that corrects for absolute power levels,
frequency response, and mismatch errors.
□
Intermodulation distortion application (Option 087)
The intermodulation distortion (IMD) application makes it very
easy to set up and calibrate swept-IMD measurements of
both amplifiers and frequency converters. It uses the built-in
second source and internal combiner of the PNA-X (requires
Option 224 or 423). The user can sweep either the center
frequency of the two stimulus signals, the frequency spacing
of the two stimulus signals about a fixed center frequency, or
the power of one or both stimulus signals or the power of the
LO signal. The analyzer can measure intermodulation distortion
products of order 2, 3, 5, 7, or 9, and can display the associated
intercept points. In addition, an IM Spectrum mode gives a
spectrum-analyzer-like display for confirming or trouble-shooting
measurements. Requires firmware A.08.33 and above.
□
Integrated true-mode stimulus application (Option 460)
Integrated true-mode stimulus application (iTMSA) provides
mismatch-corrected true-mode (true differential and true
common) stimulus and enables accurate balanced measure-
ments under real operating conditions. iTMSA also provides
balanced measurements with forward-only sweep, reverse-only
sweep, and frequency or power sweep with arbitrary phase
and amplitude offsets. Requires firmware A.08.20 and above.
□
N-port capabilities (Option 551)1
Adds a multiport analyzer mode to the PNA-X network analyzer,
that enables full N-port error correction and measurement
capabilities using an external test set. Only standard measure-
ment class is available in the multiport analyzer mode.
1. When configured as a multiport analyzer using Option 551 and a multi-
port test set, the combiner feature of Option 224 or 423 is temporarily
disabled. When configured as a standalone analyzer, the combiner
feature is enabled. When ordering a test set, select a test set option
to specify an appropriate interconnect jumper cable set between the
analyzer and the test set.
PNA-X Series Network Analyzer
Measurement applications
(continued)
□
Noise figure measurements using standard receivers (Option 028)
This option adds firmware for high-accuracy noise figure measure-
ments of amplifiers, frequency converters, and mixers using the
PNA-X’s standard receivers, and utilizing Agilent’s unique source-
correction technique. Using the PNA-X and an Agilent ECal module
configured as an impedance tuner, the effects of imperfect system
source match are removed, greatly improving the accuracy of the
cold-source technique. This approach surpasses the accuracy pro-
vided by the Y-factor method. For fully corrected noise figure mea-
surements, this option requires an ECal module (m-f recommended)
and a power meter (both must be ordered or supplied separately). A
scalar calibration choice is also available that offers less accuracy,
but is faster and does not require the ECal module used as an
impedance tuner. The power meter is only used during calibration of
the analyzer. During calibration of the analyzer, an additional ECal or
mechanical calibration kit is required (also must be ordered or sup-
plied separately). To use a m-f ECal module as a tuner (N4691B/
93A-M0F), Option 028 includes a semi-rigid cable (3.5 mm N5242-
20137 for N5241/42A or 2.4 mm N5245-20140 for N5244/45A) and
a m-f adapter (3.5 mm 85052-60013 for N5241/42A or 2.4 mm
85056-60007 for N5244/45A). For use with f-f ECal modules
(N4691B/93A-00F), order a m-m adapter (3.5 mm 85052-60014 or
2.4 mm 85056-60005). No external preamplifier is required for
devices with 30 dB or more of excess noise (gain plus noise figure).
Front panel jumpers provide a convenient spot for adding a pre-
amplifier and filter(s) for low gain, low noise figure devices.
□
Fully-corrected noise figure measurements (Option 029)
This option adds high-sensitivity noise receivers and firmware
for high-accuracy noise figure measurements of amplifiers,
frequency converters, and mixers, utilizing Agilent’s unique
source-correction technique. Using the PNA-X and an Agilent
ECal module configured as an impedance tuner, the effects of
imperfect system-source match are removed, greatly improv
ing the accuracy of the cold-source technique. This approach-
surpasses the accuracy provided by the Y-factor method. For
fully corrected noise figure measurements, this option requires
a 3.5 mm N4691B ECal module (m-f recommended) and a
346C noise source (both must be ordered or supplied sepa-
rately). A scalar calibration choice is also available that offers
less accuracy, but is faster and does not require the ECal mod-
ule used as an impedance tuner. For measurements of mixers
and converters, a power meter is also required. The noise
R1
J11 J10 J9 J8
OUT 1
Source 1
A
Test port 1
OUT 2
J7
OUT 1
Source 2
Source 2
Output 1
OUT 2
Source 2
Output 2 rear panel
R2
J2 J1
10 MHz -
3 GHz
Test port 2
Noise receivers
B
3 -26.5 GHz
source and power meters are only used during calibration of
the analyzer. During calibration of the analyzer, an additional
ECal or mechanical calibration kit is required (also must be
ordered or supplied separately). To use a 3.5 mm m-f ECal
module as a tuner (N4691B-M0F), Option 029 includes a
3.5 mm semi-rigid cable (N5242-20137) and 3.5 mm m-f
adapter (85052-60013). For use with 3.5 mm f-f ECal modules
(N4691B-00F), order a 3.5 mm m-m adapter (85052-60014).
Option 029 also allows noise figure measurements using the
standard receivers for high-gain (> 60 dB) devices that might
otherwise overload the noise receivers.
□
Add 26.5 GHz noise receivers (Option H29)
This option adds 26.5 GHz high-sensitivity noise receivers to
N5244A 43.5 GHz and N5245A 50 GHz PNA-X models. The
option also enables use of the standard receivers for noise
figure measurements up to 43.5 or 50 GHz. Both receiver
choices yield high-accuracy noise figure measurements of
amplifiers, frequency converters and mixers, utilizing Agilent’s
unique source-correction technique. Using the PNA-X and an
Agilent ECal module configured as an impedance tuner, the
effects of imperfect system-source match are removed, greatly
improving the accuracy of the cold-source technique. This
approach surpasses the accuracy provided by the Y-factor
method. For fully corrected noise figure measurements, this
option requires an ECal module (2.4 mm N4693A m-f recom-
mended) and a 346C noise source (both must be ordered or
supplied separately). A scalar calibration choice is also available
that offers less accuracy, but is faster and does not require the
ECal module used as an impedance tuner. For measurements of
mixers and converters, a power meter is also required. The
noise source and power meter are only used during calibration
of the analyzer. During calibration of the analyzer, an additional
ECal or mechanical calibration kit is required (also must be
ordered or supplied separately). To use a 2.4 mm m-f ECal
module as a tuner (N4693A-M0F), Option H29 includes a 2.4 mm
semi-rigid cable (N5245-20140) and 2.4 mm m-f adapter (85056-
60007). For use with f-f ECal modules (N4693A-00F), order a
2.4 mm m-m adapter (85056-60005). For use with 3.5 mm m-f
ECal modules (N4691B-M0F), order two 2.4 mm to 3.5 mm m-f
adapters (11901C), plus a 3.5 mm semi-rigid cable (N5242-
20137) and a 3.5 mm m-f adapter (85052-60013). For use with
3.5 mm f-f ECal modules (N4691B-00F), order two 2.4 mm to
3.5 mm m-f adapters (11901C), plus a 3.5 mm semi-rigid cable
(N5242-20137) and a 3.5 mm m-m adapter (85052-60014).
9
PNA-X Series Network Analyzer
PNA-X Noise Figure Options Summary
Overview
Description
Required options
Option 028
Noise fi gure application using standard receivers only, for all
PNA-X models.
080
No
No
Option 029
Noise fi gure application using standard or low-noise receivers, for N5241/42A models.
080 plus one of: 219, 224, 419,
423, or H85
Yes
Yes
Includes low-noise receivers
Includes fi lters for LO-harmonic rejection
Includes source tuner bypass switch
Use standard receivers for noise fi gure measurements
1
Vector noise calibration available
(using ECal as tuner)
Scalar noise calibration available
Recommended ECal for vector noise calibration
S-parameter, conversion gain/loss measurements
Max freq (GHz)
Noise fi gure measurements, amplifi ers
Max frequency, using low-noise receivers (GHz)
Max frequency, using standard receivers (GHz) 1
Calibration accessories for low-noise receivers
Calibration accessories for standard receivers
Noise fi gure measurements, converters
Max input frequency (GHz)
Max output frequency, using low-noise receivers (GHz)
Max output frequency, using standard receivers (GHz)
1
Calibration accessories for low-noise receivers
Calibration accessories for standard receivers
No
Yes
Yes
Yes
N4691B-M0F (41/42A),
N4693A-M0F (44/45A)
13.5/26.5/43.5/50
N/A
13.5/26.5/43.5/50
N/A
Cal kit or ECal, power meter
13.5/26.5/43.5/50
N/A
13.5/26.5/43.5/50
N/A
Cal kit or ECal, power meter
Yes
Yes
Yes
Yes
N4691B-M0F
13.5/26.5
13.5/26.5
13.5/26.5
Cal kit or ECal, 346C noise source
Cal kit or ECal, power meter
13.5/26.5
13.5/26.5
13.5/26.5
Cal kit or ECal, 346C noise source, power meter
Cal kit or ECal, power meter
Option H29
Noise fi gure application using standard or low-noise receivers, for N5244/45A models.
080, 423
Yes, up to 26.5 GHz
Yes, up to 26.5 GHz
Yes
Yes
Yes
Yes
N4693A-M0F
43.5/50
26.5
43.5/50
Cal kit or ECal, 346C noise source
Cal kit or ECal, power meter
43.5/50
26.5
43.5/50
Cal kit or ECal, 346C noise source, power meter
Cal kit or ECal, power meter
1. External preamp and filter(s) required if DUT gain + NF < 30 dB
10
PNA-X Series Network Analyzer
Nonlinear vector network analysis
Please refer to the Nonlinear Vector Network Analyzer brochure for more information 5989-8575EN
Pulse, antenna, mm-wave
□
Pulsed-RF measurements (Option 008)
This option extends the pulsed-RF measurement capability of
the PNA-X to pulse widths below 267 ns, which is the limit for
the standard wideband detection mode. The PNA-X is a complete
pulsed-RF solution with built in pulse generators and modulators,
so external test sets and pulse generators are not required.
null out unwanted spectral components, enables the internal
receiver IF gates, controls internal pulse generators (Option 025),
internal pulse modulators (Option 021 and/or 022), and external
pulse modulators, and performs optimization for measurement
sensitivity. Option 008 also includes conventional pulsed-RF
measurement software (Option H08), which can run on the
PNA-X or an external computer. The N1966A pulse I/O adapter is
recomended using external pulse generators and/or external pulse
modulators.
□
Add IF inputs for antenna and millimeter-wave (Option 020)
This option enables external IF inputs on the rear panel of the
PNA-X for applications such as antenna and millimeter-wave
test.
□
Add pulse modulator to internal first source (Option 021)
This option enables the internal pulse modulator on source 1.
Control of the modulator can also be done via pin 8 of the
Pulse I/O D-sub connector on the rear panel of the PNA-X
using an external pulse generator, or by using one of the internal
pulse generators (Option 025). The N1966A pulse I/O adapter
is recommended if using an external pulse generator.
(See diagram below for details of the D-sub connector.)
□
Add pulse modulator to internal second source (Option 022)
This option enables the internal pulse modulator on source 2.
Control of the modulator can also be done via pin 8 of the
Pulse I/O D-sub connector on the rear panel of the PNA-X
using an external pulse generator, or by using one of the internal
pulse generators (Option 025). The N1966A pulse I/O adapter
is recommended if using an external pulse generator. Option 224
or 400 required. (See diagram for details of the D-sub connector.)
□
Add four internal pulse generators (Option 025)
This option enables four internal pulse generators. These
pulse generators can be used to control the internal pulse
modulators and internal receiver IF gates, and are also available
on pins 10 through 13 of the Pulse I/O D-sub connector on
the rear panel of the PNA-X to control external modulators
and/or gates. The N1966A pulse I/O adapter is recommended
if using external pulse modulators. (See diagram for details of
the D-sub connector.)
□
Fast CW Sweep (Option 118)
This option uses FIFO (fi rst-in fi rst-out) to allow external point-
trigger acquisition of 400,000 data points per second on fi ve
measurement receivers. When enabled, there is no display
update, no background computation, or other interference
from the vector network analyzer application. All the data
gathered is placed into a 500 million points FIFO buffer. While
the data is going into FIFO it can be read from the FIFO buffer.
Accessories
□
Rack mount kit without handles (Option 1CM)
Adds a rack mount (5063-9217) and rail kit (E3663AC) for use
□
Pulse I/O adapter (N1966A)
An adapter for connecting between the Pulse I/O connector on
the rear panel of the PNA-X and the coaxial inputs and outputs
of external pulse generators and external pulse modulators.
Coaxial connectors are SMB-male. The PULSE IN connectors
are for controlling the PNA-X's internal IF gates, which are
enabled with Option H08 and used with narrowband detection.
The PULSE OUT connectors are from the PNA-X's four internal
pulse generators, which are enabled with Option 025. The
PULSE SYNC IN connector is used to synchronize the internal
pulse generators with an external timing pulse. The RF PULSE
MOD IN connector controls the internal pulse modulator(s) which
are enabled with Options 021 and 022.
Pulse I/O adapter (N1966A) simplifies connections
8
1 5
7
1 4
6
1 3
5
1 2
4
1 1
3
1 0
2
9
1
Pulse I/O D-sub connector (DB-15 female)
11
PNA-X Series Network Analyzer
Upgrade kits
Upgrade kits are available to add options after initial purchase. To upgrade the PNA-X, order the corresponding item number.
The model and serial numbers of the instrument to be retrofitted are required as part of the order.
Description
Frequency upgrade 1
N5242A Extend analyzer’s frequency
Required option For N5241A For N5242A For N5244A For N5245A User installable
N5245A range to 26.5 GHz
Extend analyzer’s frequency
N5241A
N5244A
N5241AU-960
N/A
N/A
N/A
N/A N/A
N5244AU-990 N/A
No
No
Test set range to 50 GHz
Option 224 2-ports, add internal 2nd source, Options 200, 219 N5241AU-922 N5242AU-922 N5244AU-922 N5245AU-922 No combiner and mechanical switches
Option 423 4-ports, add internal combiner and Options 400, 419 N5241AU-927 N5242AU-927 N5244AU-927 N5245AU-927 No mechanical switches
Power configuration
Option 219 2-ports, extended power range Option 200 and bias-tees
N5241AU-921 N5242AU-921
N5244AU-921 N5245AU-921 No
Option 419 4-ports, extended power range Option 400 and bias-tees
Option H85 High-power configurable
(for 2- or 4-port) 419 or 423
N5241AU-926
Option 219, 224, N5241AU-H85
N5242AU-926
N5242AU-H85
N5244AU-926 N5245AU-926
N5244AU-H85 N5245AU-H85
No
No
Measurement applications
Option 010 Time-domain measurements
Option 028 Noise figure measurements using standard receivers
Option 029 Fully-corrected noise figure measurements for 2-port
Option 029 Fully-corrected noise figure measurements for 4-port or H85, and 080 or H85, and 080
Option H29 Add 26.5 GHz noise receivers Option 423
Option 080 Frequency offset
N5241AU-010
Option 219, 224, N5241AU-924
Option 419, 423, N5241AU-929
N/A
N5241AU-080
N5242AU-010
N5242AU-924
N5242AU-929
N/A
N5242AU-080
N/A
N/A
N5244AU-010 N5245AU-010
N5241AU-028 N5242AU-028 N5244AU-028 N5245AU-028
N/A
N/A
Yes
Yes
No
No
N5244AU-H29 N5245AU-H29 No
N5244AU-080 N5245AU-080 Yes
Option 082 Scalar-calibrated converter measurements
Option 083 Vector- and scalar-calibrated converter measurements
Option 084 Embedded LO measurements
Option 086 Gain compression application
Option 080
Option 080
N5241AU-082
N5241AU-083
N5242AU-082
N5242AU-083
N5244AU-082 N5245AU-082
N5244AU-083 N5245AU-083
Yes
Yes
Option 028, 029, N5241AU-084 N5242AU-084 N5244AU-084 N5245AU-084 Yes
H29, 082, 083, or
087
N5241AU-086 N5242AU-086 N5244AU-086 N5245AU-086 Yes
Option 087 Intermodulation distortion application
Option 460 Integrated true-mode stimulus Option 400 application
Option 551 N-port capabilities
Option 224 or 423
N5241AU-087
N5241AU-460
N5241AU-551
N5242AU-087
N5242AU-460
N5242AU-551
N5244AU-087 N5245AU-087
N5244AU-460 N5245AU-460
N5244AU-551 N5245AU-551
Yes
Yes
Yes
Nonlinear vector network analysis
Option 510 Nonlinear component
Option 514 Nonlinear X-parameters
Option 518 Nonlinear pulse envelope
Option 520 characterization domain
Arbitrary load-impedance
X-parameters
Options 419 and N5241AU-510 N5242AU-510 N5244AU-510 N5245AU-510 Yes
080, or 400, H85 and 080
Options 423, N5241AU-514 N5242AU-514 N5244AU-514 N5245AU-514 Yes
510
Options 021, 025 N5241AU-518 N5242AU-518 N5244AU-518 N5245AU-518 Yes and either one of
510 or 514
Option 514 N5241AU-520 N5242AU-520 N5244AU-520 N5245AU-520 Yes
1. Frequency upgrade options from N5241A or N5242A to N5244A or N5245A are not available. Trade-in is recommended.
12
PNA-X Series Network Analyzer
Upgrade kits (continued)
Upgrade kits are available to add options after initial purchase. To upgrade the PNA-X, order the corresponding item number.
The model and serial numbers of the instrument to be retrofitted are required as part of the order.
Description
Pulse, antenna, mm-wave
Required option For N5241A
Option 008 Pulsed-RF measurements
Option 020 Add IF inputs for antenna and mm-wave
Option 021 Add pulse modulator to internal
Option 025 N5241AU-008
N5241AU-020
For N5242A
N5242AU-008
N5242AU-020
For N5244A For N5245A
N5244AU-008 N5245AU-008
N5244AU-020 N5245AU-020
User installable
Yes
Yes
N5241AU-021 N5242AU-021 N5244AU-021 N5245AU-021 Yes
1st source
Option 022 Add pulse modulator to internal Option 224 or 400 N5241AU-022 N5242AU-022 N5244AU-022 N5245AU-022 Yes
2nd source
Option 025 Add four internal pulse N5241AU-025 N5242AU-025 N5244AU-025 N5245AU-025 Yes generators
Option 118 Fast CW sweep N5241AU-118 N5242AU-118 N5244AU-118 N5245AU-118 Yes
N5241AU-897 N5242AU-897 N5244AU-897 N5245AU-897 Yes
Calibration Software
Option 897 Perpetual license for built-in performance test software for
Agilent inclusive calibration
Option 898 Perpetual license for built-in performance test software for standards compliant calibration
N5241AU-898 N5242AU-898 N5244AU-898 N5245AU-898 Yes
Frequency
13.5 GHz
N5241AU-960
26.5 GHz
43.5 GHz
N5244A-990
50 GHz
PNA-X upgrade path
2-port 4-port
944
942
200
921
940
922
224 219
219
029
924
922
224
029
924
400
926
419
927
929
419
029
927
423
929
423
029
H85
high power
H85
high power
13
PNA Series Network Analyzer 1
E8362C
E8363C
E8364C
10 MHz to 20 GHz
10 MHz to 40 GHz
10 MHz to 50 GHz
E8361C
N5250C 2
Option configurations
To add options to a product, order the corresponding item number.
10 MHz to 67 GHz
10 MHz to 110 GHz
Description
Test set
Option 014 • Configurable test set
For E8362C For E8363C For E8364C For E8361C For N5250C Additional system 3
E8362C-014 E8363C-014 E8364C-014 E8361C-014 Included
Power configuration
Option UNL • Extended power range E8362C-UNL E8363C-UNL E8364C-UNL E8361C-UNL Included
and bias-tees
information
Only E8361C requires 014
Option 016 • Add receiver attenuators E8362C-016 E8363C-016
H85 7 • High-power configuration E8362CH85 E8363CH85
E8364C-016 E8361C-016
E8364CH85 Contact
Agilent
E8361C-016 Requires UNL
(only E8361C also
Contact Includes 014, 016,
Agilent UNL* 4 , 080, 081
Measurement applications
Option 010 • Time-domain capability
Option 080 • Frequency offset
E8362C-010 E8363C-010
E8362C-080 E8363C-080
E8364C-010 E8361C-010 E8361C-010
E8364C-080 E8361C-080 Included Requires 014
(E8361C only, 081 required if UNL is also purchased)
Option 081 • Reference receiver switch E8362C-081 E8363C-081 E8364C-081 E8361C-081 Included Requires 014, 080
(only E8361C also
Option 082 • Scalar-calibrated
converter measurements
E8362C-082 E8363C-082 E8364C-082 E8361C-082 5 Requires 014, 080
Option 083 • Vector- and scalar-calibrated E8362C-083 E8363C-083 E8364C-083 E8361C-083 E8361C-083
5
converter measurements
Requires 014, 080,
081(only E8361C also requires UNL)
084
550
6
9
• Embedded LO measurements E8362C-084 E8363C-084 E8364C-084 E8361C-084 E8361C-084 Requires 082 or 083
551
9
• 4-port measurement application E8362C-550 E8363C-550 E8364C-550 E8361C-550 N/A
• N-port capabilities E8362C-551 E8363C-551
Requires 014
E8364C-551 E8361C-551 N/A Requires 014
Pulse, antenna, mm-wave
Option H08 • Pulsed-RF measurement E8362C-H08
Option
E8363C-H08 E8364C-H08 E8361C-H08 E8361C-H08 5
H11
capability
• IF access (for antenna, E8362C-H11 E8363C-H11 E8364C-H11 E8361C-H11 Included
pulsed-RF and mm-wave
measurements)
Requires 014, 080
(Option H11 recommended)
Requires 014, UNL,
080, and 081
Accessories
Option 1CM • Rack mount kit for use
without handles
Option 1CP • Rack mount kit for use
N4688A
N4689A
with handles
• USB CD R/W drive
• USB Hub
Calibration documentation
Option 1A7 • ISO 17025 compliant
calibration
E8362C-1CM
E8362C-1CP
N4688A
N4689A
E8362C-1A7
E8363C-1CM
E8363C-1CP
N4688A
N4689A
E8363C-1A7
E8364C-1CM
E8364C-1CP
N4688A
N4689A
E8364C-1A7
E8361C-1CM E8361C-1CM
E8361C-1CP E8361C-1CP
N4688A
N4689A
N4688A
N4689A
E8361C-1A7 E8361C-1A7
Option UK6 • Commercial calibration E8362C-UK6 E8363C-UK6 E8364C-UK6 E8361C-UK6 E8361C-UK6
certificate with test data
Option A6J • ANSI Z540 compliant
calibration
Calibration software for self-maintainers
897 8
E8362C-A6J E8363C-A6J
performance test software for Agilent exclusive calibration
E8364C-A6J E8361C-A6J E8361C-A6J
898 8
performance test software for standards compliant calibration
1. All models are not available in all countries.
2. For more detailed information regarding the 110 GHz network analyzer system, refer to the Agilent Web site: www.agilent.com/find/pna
and download the N5250C Technical Overview, literature number 5989-7620EN.
3. The N5250C 110 GHz system also includes an N5260A millimeter-wave test set controller, 1.0 mm combiner assembly, interconnect cables,
and installation and productivity assistance.
4. UNL* does not include bias-tees. Only includes source attenuators.
5. Up to 67 GHz.
6. Requires firmware A.07.05 and above, plus 1.1 GHz CPU board.
7. Option H85 is ordered as a separate model, as indicated.
8. Additional hardware required. Please refer to the analyzer’s Service Guide for required service test equipment.
9. Option 550 is a subset of 551; therefore they cannot be ordered together. When ordering a test set, select an option to specify the appropriate
interconnect jumper cable set between the analyzer and the test set.
14
PNA Series Network Analyzer
The microwave PNA Series instruments are integrated vector network analyzers equipped with a built-in S-parameter test set, synthesized source, a hard disk drive, USB interfaces, and an
8.4” LCD color touch screen display. The E8362C has 3.5 mm male 50-ohm test ports. The E8361C has 1.85 mm male 50-ohm test ports. Included with each instrument is a mouse, keyboard
(U.S.) and a 1-year return-to-Agilent service warranty.
●
E8362C network analyzer, 10 MHz to 20 GHz
●
E8363C network analyzer, 10 MHz to 40 GHz
●
E8364C network analyzer, 10 MHz to 50 GHz
●
E8361C network analyzer, 10 MHz to 67 GHz 1
●
N5250C network analyzer system, 10 MHz to 110 GHz
Test set and power configuration options
□
Configurable test set (Option 014) 2
Provides six front panel access loops. Three access loops are
for port one and three for port two. The loops provide access
to the signal path between (a) the source output and the
reference receiver, (b) the source output and directional coupler
thru arm and (c) the coupled arm of the directional coupler and
the port receiver. This option provides the capability to improve
instrument sensitivity for measuring low-level signals, to
reverse the directional coupler to achieve even more dynamic
range or to add components and other peripheral instruments
for a variety of measurement applications. (see PNA Series
Microwave Data Sheet literature number 5989-7605EN for a
basic block diagram)
□
Extended power range and bias-tees (Option UNL) 2
Adds two 60 dB step attenuators and two bias-tees to the
E8362/3/4C. Adds two 50 dB step attenuators and two bias-tees
to the E8361C. A step attenuator and bias-tee set is inserted
between the source and test port one and another set
between the source and test port two. (see PNA Series
basic block diagram)
□
Add receiver attenuators (Option 016)
An attenuator is added between each test port and its
to the E8362/3/4C. Two 50 dB step attenuators are added to
the E8361C (see PNA Series Microwave Data Sheet literature
number 5989-7605EN for a basic block diagram).
□
High-power test set (Model E836xCH85)
This configuration combines options that are often necessary
for high power measurements (UNL* 3 , 014, 016, 080, 081).
The only difference between ordering Option H85 versus a
combination of the options listed above is the source
attenuator option UNL. Standard UNL includes two source
attenuators and two bias-tees. Option H85 includes the two
source attenuators, but not the bias-tees, as the bias-tees are
maximum power at the test port is +43 dBm (< 20 GHz), and
+40 dBm (> 20 GHz).
1. The E8361C can be extended to 110 GHz with IF access (Option H11).
2. Up to 67 GHz.
3. UNL* does not include bias-tees. Only includes source attenuators
Option 080, frequency-offset mode, is included in Option H85
because it manages the phase-locking internally (instead of
depending on the R1 receiver). So if you need to use external
components in the path of the R1 receiver, it makes the
measurements simpler and more robust.
Measurement applications
□
Time-domain capability (Option 010)
For viewing reflection and transmission responses in time or
□
Frequency offset (Option 080) 2
This option enables the PNA Series microwave network analyzers
to set the source frequency independently from where the
receivers are tuned. This ability is important for two general
classes of devices: mixers (and converters) and amplifiers.
Option 080 provides a very basic user interface.
□
Reference receiver switch (Option 081) 2
Option 081 adds a solid-state internal RF transfer switch in the
R1 reference-receiver path (see PNA Series Microwave Data
Sheet literature number 5989-7605EN for a block diagram). The
switch allows the instrument to easily switch between standard
S-parameter (non-frequency-offset) measurements and frequency
offset measurements such as relative phase or absolute group
delay that require an external reference mixer. The user can set
the switch manually or remotely, but it is best used with the
frequency-converter application (Option 083), where it is controlled
automatically during the vector-mixer calibration procedure
and subsequent measurements.
□
Scalar-calibrated converter measurements (Option 082) 2
With a simple setup and calibration, this application provides
the highest accuracy for conversion-loss (or gain) measurements
by combining one-port and power-meter calibrations to remove
mismatch errors. Option 080 required.
□
Vector- and scalar-calibrated converter measurements
083) 2
This converter measurement adds an intuitive and easy-to-use
user interface, advanced calibration choices that provide
exceptional amplitude and phase accuracy, and control of
external signal sources for use as local oscillators. Mixer
calibration techniques include scalar-mixer calibration and
vector-mixer calibration (requires Option 081). Finally, the
frequency-converter application supports all of Agilent’s major
signal source families.
□
Embedded LO Measurements (Option 084)
This option tunes the PNA receivers to the output frequency of
the converter under test, without the need for access to internal
LOs or a common reference signal. For converters with embed-
ded LOs, this option enables measurements of match-corrected
conversion loss/gain (requires Option 082 or 083), and absolute
group delay (requires Option 083).
15
PNA Series Network Analyzer
□
4-port measurement application (Option 550) 1
Adds multiport analyzer mode to any PNA network analyzer
with Option 014 configurable test set, which enables full
4-port error correction and measurement capabilities using an
external test set. Only standard measurement class is available
in the multiport analyzer mode.
□
N-port capabilities (Option 551) 1
Adds multiport analyzer mode to any PNA network analyzer
with Option 014 configurable test set, which enables full
N-port error correction and measurement capabilities using
an external test set. Only standard measurement class is
available in the multiport analyzer mode.
Pulse, antenna, mm-wave
□
Pulsed-RF measurement capability (Option H08) 1
Provides software to set up and control pulsed-RF measurements
with point-in-pulse capability. The software sets the coefficient
of the PNA’s digital-IF filter to null out unwanted spectral
components, enables the IF gates provided with IF access
(Option H11), and controls selected Agilent pulse generators.
It can be run on the PNA or an external computer. A “.dll” file
containing the IF-filter algorithms is included for automated
with the Agilent 81110A series pulse generator.
For more detailed information regarding pulsed measurement
capabilities with the microwave PNA refer to the Agilent Web
MW Network Analyzers Configuration Guide for Pulsed
Measurements, literature number 5989-7913EN.
□
IF access (Option H11)
Provides hardware to enable antenna, point-in pulse, and
broadband millimeter-wave measurements to 110 GHz. For
each of the MW PNA’s measurement receivers, IF gates
(enabled with pulsed measurement capability, Option H08) and
external IF inputs are added. In addition, access to the PNA’s
internal RF and LO source is provided for remote mixing
applications. For basic antenna measurements, only Option H11
is necessary. Pulsed antenna applications also require the
pulsed measurement capability (Option H08). Broadband
measurements to 110 GHz, also requires an N5260A
millimeter-wave test set controller.
Note: Use external IF access for up to 20 dB more sensitivity
when making antenna measurements with a remote mixing
configuration. Add Option H08 (Pulsed-RF Measurement
Capability) to enable advanced pulsed measurements. Or
upgrade to a broadband (10 MHz to 110 GHz) VNA system
simply by purchasing an N5260A controller test set with test
heads (Option 110, 120, or 130).
Accessories
□
Rack mount kit without handles (Option 1CM)
Adds a rack mount (5063-9217) and rail kit (E3663AC) for use
□
Rack mount kit with handles (Option 1CP)
Adds a rack mount (5063-9237) 2 and rail kit (E3663AC) for use
with standard supplied handles.
Configuration Details
Selecting the correct mixer-test configuration:
Most mixer or converter test applications require Options 014, 080, and 082 for conversion loss/gain, or Options 014, 080, 081 and
083 for conversion loss/gain and phase/delay measurements. If you want to create and automate your own custom frequencyoffset measurements (for example, intermodulation distortion), you may only need Options 014 and 080. For converters that require input power below -27 dBm, or for devices that have a large amount of LO feedthrough (like an unfi ltered mixer), Option
UNL, which adds source attenuators, is highly recommended.
Besides allowing lower input power levels, these attenuators improve the isolation between the PNA’s internal source and
LO leakage signals, helping to prevent source-unleveled errors.
For devices that put out signals near or above the receiver’s compression levels (which varies between –3 and +5 dBm, depending on the model and frequency), Option 016 is recommended, which adds receiver attenuators. Finally, Option 010, which adds time-domain analysis, is very useful for gating out unwanted, time-delayed responses which often occur when measuring mixers.
1. Up to 67 GHz.
2. The 5063-9237 kit assumes you have the standard handles shipped
with the instrument. If you do not have handles, order a 5063-9224 kit.
16
PNA Series Network Analyzer
Simplified test set block diagrams
R1
Reference receiver
Source
Switch/splitter
Reference receiver R2
A
Measurement receivers
B
Port 1
Extended power range and bias-tees (Option UNL)
Port 2
Bias-tee
R1
Reference receiver
Source attenuator
1
Source
Switch
Reference receiver
A
Measurement receivers
B
R2
Source attenuator
1
Bias-tee
Port 1
1. Source attenuator for E8362/3/4C is 60 dB in 10 dB steps.
Source attenuator for E8361C is 50 dB in 10 dB steps.
Port 2
17
PNA Series Network Analyzer
Simplified test set block diagrams – continued
Configurable test set (Option 014)
R1
Reference receiver
Source
Switch
Reference receiver R2
A
Measurement receivers
B
Port 1 Port 2
Configurable test set with extended power range and bias-tees (Option UNL and 014)
R1
Source attenuator
1
Reference receiver
Source
Switch
Reference receiver R2
Source attenuator
1
Bias-tee
A
Measurement receivers
B
Bias-tee
Port 1
1. Source attenuator for E8362/3/4C is 60 dB in 10 dB steps.
Source attenuator for E8361C is 50 dB in 10 dB steps.
18
Port 2
PNA Series Network Analyzer
Simplified test set block diagrams – continued
Fully optioned, active device or mixer/converter test configuration (Options 014, UNL, 016, 080, 081)
Option 081
Source out
Rcvr R1 in
Source
Switch/splitter/leveler
R1
Reference receiver
Source attenuator 1
10 dB steps
Bias-tee
Measurement receivers
A
Receiver attenuator 2
B
Reference receiver R2
Source attenuator 1
10 dB steps
Bias-tee
SRC out
Cplr thru
Cplr arm
Rcvr A in
Rcvr B in
Cplr arm
Cplr thru
SRC out
Rcvr R2 in
Source out
1. Source attenuator for E8362/3/4C is 60 dB in 10 dB steps. Source attenuator for
E8361C is 50 dB in 10 dB steps.
2. Receiver attenuator for E8362/3/4C is 35 dB in 5 dB steps. Receiver attenuator for
E8361C is 50 dB in 10 dB steps.
19
PNA Series Network Analyzer
Simplified test set block diagrams – continued
High-power configuration (Model E836xCH85)
Option 081
Source out
Rcvr R1 in
Source
+15
R1
Reference receiver
Source attenuator 1
+30 dBm
10 dB steps
Switch/splitter/leveler
+30 dBm
Reference receiver
Measurement receivers
Source attenuator 1
+30 dBm
10 dB steps
+15
A
+15
B
+40 dBm
+30 dBm
Receiver attenuator 2
+30 dBm +40 dBm
SRC out
Cplr thru
Cplr arm
Rcvr A in
Rcvr B in
Cplr arm
Cplr thru
SRC out
Rcvr R2 in
Source out preamp
Power levels shown on the diagram are damage levels. At a minimum, keep power levels 6 dB below damage level. For optimal performance, keep the power level incident upon the receivers -20 dBm or less. This will keep the receivers out of compression.
1. Source attenuator for E8362/3/4C is 60 dB in 10 dB steps.
2. Receiver attenuator for E8362/3/4C is 35 dB in 5 dB steps.
20
PNA Series Network Analyzer
Simplified test set block diagrams – continued
Fully optioned, pulse-RF, antenna, or mm-wave configuration
(Options 014, UNL, 016, 080, 081, H11)
Aux RF out
(2 to 20 GHz)
Aux LO out
(2 to 20 GHz)
Rear
Option 080
Phase-locked loop
8.33 MHz reference
Offset receiver
Offset
LO
Option 081
V tune
YIG source
Multipliers
(1, 2)
Multipliers (1, 2, 4)
LO
Option H11
Option H11 1
IF gate
ADC
External
IF in
Option UNL
R1 R2
Option H11 1
IF gate
ADC
External
IF in
Option UNL
Front
Option 014
External
IF in
ADC
IF gate
Option H11 1
Option UNL
A
Port 1
Option 016
Receiver attenuators
Option 014
B
External
IF in
IF gate
Option H11 1
ADC
Option UNL
Port 2
Option 014
1. Option H11: IF-gate controls and external-IF inputs are accessed on rear panel.
IF gates are enabled with Option H08. External-IF input frequency is 8.33 MHz.
21
PNA Series Network Analyzer
N5250C millimeter-wave system
□
N5250C MM PNA system 1 , 10 MHz to 110 GHz, includes:
E8361C MW PNA with the following options:
• Configurable test set – Option 014
• Extended power range and bias-tees –
• Frequency-offset mode – Option 080
• Reference channel switch – Option 081
• IF access – Option H11
N5260A millimeter-wave test set controller with test heads
• 67 to 110 GHz test heads
Additional options available:
• Millimeter-wave modules with bias-tees -
Banded waveguide solution
In order to assemble a banded waveguide solution, the following components are needed:
• Microwave PNA network analyzer (E8361C or E8362/3/4C) with the following options:
• IF access - Option H11
• Configurable test set - Option 014
• Extended power range and bias-tees - Option UNL
• Frequency-offset mode - Option 080
• Reference channel switch - Option 081
• Millimeter-wave test set controller (N5260A)
with no options
• A set of waveguide modules:
• N5256AW15, 50 to 75 GHz
• N5256AW12, 60 to 90 GHz
• N5256AW10, 75 to 110 GHz
• N5256AW08, 90 to 140 GHz
• N5256AW06, 110 to 170 GHz
• N5256AW05, 140 to 220 GHz
• N5256AW03, 220 to 325 GHz
• Millimeter-wave modules with bias-tees and
port 2 attenuator - N5250C Option 018
• Receiver attenuator – Option 016
• Time-domain capability – Option 010
• Pulsed-RF measurement capability – Option H08 2
• Scalar-calibrated converter measurements – Option 082 2
• Frequency converter application – Option 083 2
Factory integration of the N5250C system integrates the E8361C with Option H11 and the N5260A millimeter-wave controller with test heads. On-site installation is included, and the entire system carries a full one-year, on-site warranty (where available).
NOTE: To significantly improve system dynamic range above 220 GHz,
Agilent strongly recommends adding two external synthesizers such as Agilent’s PSG Series signal generators; one for the RF signal, and one for the LO signal.
For more detailed information, see PNA Millimeter-wave Technical
Overview, literature number 5989-7620EN.
Option Descriptions
□
Millimeter-wave modules with bias-tees (N5250C Option 017)
Adds 67 GHz bias-tees to the combiner assembly between the
input to the combiner and the 67 GHz coupler. The bias-tees have
tri-axial connectors for force, sense, and ground. Positioning the
bias-tees close to the DUT greatly improves stability for on-wafer
On-wafer applications
For on-wafer applications, Cascade Microtech 3 provides complete probing systems using the N5250C. These include both new probing systems and upgrades to existing Cascade Microtech products.
Cascade can also provide on-wafer verification and probing system training. Once the N5250C system is verified in coax, Cascade
Microtech will verify the system through its wafer probes.
□
Millimeter-wave modules with bias-tees and port 2
Adds 67 GHz bias-tees to the combiner assembly between the input to the combiner and the 67 GHz coupler. The bias-tees have tri-axial connectors for force, sense, and ground. Positioning the bias-tees close to the DUT greatly improves stability for on-wafer and in-fixture devices. The bias-tees added for this option have a voltage rating of 40 volts and a maximum of 0.5 amps
Additionally, Option 018 adds a 25 dB micrometer attenuator to the port 2 test head.
22
PNA Series Network Analyzer
N5250C millimeter-wave system – continued
With Option 017, the signal is routed out of the PNA from the front panel jumpers rather than the ports. Without Option 017, the signal is routed from the front panel ports to the combiner assembly, allowing access to the
PNA’s internal bias-tees.
E8361C with Option H11
Receiver A
Port 1 Port 2
30 in.
76.2 cm
IF1 IF2
LO RF
IF3 IF4
Test set I/O
Receiver B
30 in.
76.2 cm
N5260A with test heads
48 in.
121.9 cm
Test set controller
Optional bias-tees
(Option 017)
67 to 110 GHz waveguide head
Test port 1
Combiner assembly
Test port 2
Combiner assembly
67 to 110 GHz waveguide head
48 in.
121.9 cm
PNA test set block diagram
Simplified receiver block diagram
SMA connectors
LO: 2 to 20 GHz
R1
IF
BNC connectors
R2
IF
A
IF
B
IF
SMA connectors
RF: 2 to 20 GHz
BNC connectors
R1 gate
R2 gate
A gate
B gate
LO distribution to each receiver
To IF multiplexer
(see Figure 5)
To IF multiplexer
(see Figure 5)
RF
LO
(from LO distribution.
See test set block diagram)
External
IF input
IF multiplexer
IF gating
A/D R1
Reference receiver
Reference receiver
R2
50 dB
Bias-tee
Port 1
A
50 dB 50 dB
Option 016 receiver attenuators
50 dB
B
Bias-tee
Port 2
23
PNA Series Network Analyzer
Upgrade kits
Upgrade kits for the PNA Series E8361C, E8362C, E8363C,
E8364C, N5250C1
Upgrade kits are available to add options after initial purchase. To order an upgrade kit for the PNA series, order the analyzer’s model number followed by a “U”, then indicate the option to be added
(for example, E8362CU-010). The current configuration and serial number of the instrument to be retrofitted are required as part of the order.
□
Time-domain (Option 010)
□
Configurable test set (Option 014)
Provides six front-panel RF access loops.
Includes installation at an Agilent service center.
□
Receiver attenuators (Option 016)
Includes installation at an Agilent service center.
□
Frequency range upgrade to an E8363C (40 GHz) PNA
Available only for the E8362C. Includes
installation at an Agilent service center.
□
Frequency range upgrade to an E8364C (50 GHz) PNA
Available only for the E8362C and E8363C.
Includes installation at an Agilent service center.
□
Frequency range upgrade to an E8361C (67 GHz) PNA
□
4-Port measurement application (Option 550)
(Available for E8361C, E8362C/3C/4C)
□
N-port capabilities (Option 551)
(Available for E8361C, E8362C/3C/4C)
Adds full N-port error correction and measurement
capabilities. Option 014 and external test set required.
□
Extended power range (Option UNL)
Adds a step attenuator and a bias-tee between source and
each test port. Includes installation at an Agilent service center.
□
Pulsed-RF measurement capability (Option H08)
Provides software to set up and control pulsed-RF
measurements using narrowband detection, with point-in-pulse
and pulse-profile capability. User installable.
□
IF access (Option H11)
Provides hardware for antenna, point-in-pulse, and millimeter-
wave measurements. Adds rear-panel RF and LO outputs,
external IF inputs, and IF gates (gates enabled with Option H08).
Includes installation at an Agilent service center.
□
High-power test set (Option H85)
2
Removes bias tees for higher test port power-handling capability.
Options UNL, 014, 016, 080, and 081 are required. Includes
installation at an Agilent Service Center.
Available only for the E8363C and E8364C.
Includes installation at an Agilent service center.
□
Frequency-offset (Option 080)
Includes installation at an Agilent service center.
□
External reference switch (Option 081)
Includes installation at an Agilent service center.
□
Scalar-calibrated converter measurements (Option 082)
User installable. Option 080 required.
□
Frequency converter measurement application (Option 083)
User installable. Option 080 and 081 required.
□
Embedded LO Measurements (Option 084)
Advanced software tuning that provides absolute group delay of
converters with embedded LOs without the need for access to a
common reference signal. The measurement result is the same as
locking the DUT LO to the reference mixer LO. (Options 080
and 083 required) Requires firmware A.07.05 and above plus
1.1 GHz CPU board.
□
A/B to C model upgrades
Order E8361AU-221, E8362BU-221, E8363BU-221, or E8364BU-221
Note:
1.1 GHz CPU is required to upgrade. Please refer to Customer Support Service
Guides for the correct part number http://na.tm.agilent.com/pna/documents.html
Calibration Software Licenses
□
Perpetual license for built-in performance test software
for Agilent inclusive cal (Option 897)
Adds built-in performance testing and calibration software
for self-maintainers. Requires additional equipment. See
the analyzer’s Service Guide for more information on
□
Perpetual license for built-in performance test software
for standards compliant cal (Option 898)
Adds built-in performance testing and calibration software
for self-maintainers. Requires additional equipment. See
the analyzer’s Service Guide for more information on
1. For N5250C upgrades, order upgrade options for E8361CU.
2. Please contact Agilent to order this upgrade.
24
PNA-L Series Network Analyzer
Option configurations
To add options to a product, order the corresponding item number.
Description For N5230C
Frequency range and test set (Mandatory, choose only one)
Option 020 300 kHz–6 GHz 2-port standard test set
Option 025
Option 120
300 kHz–6 GHz 2-port configurable test set and extended power range
300 kHz–13.5 GHz 2-port standard test set
N5230C-020
N5230C-025
N5230C-120
Option 125
Option 140
Option 145
Option 146
300 kHz–13.5 GHz 2-port configurable test set and extended power range N5230C-125
300 kHz–13.5 GHz 4-port standard test set N5230C-140
300 kHz–13.5 GHz 4-port configurable test set and extended power range N5230C-145
300 kHz–13.5 GHz 4-port configurable test set, extended power range N5230C-146
Option 220
Option 225
Option 240
Option 245
Option 246
Option 420
Option 425
520
525
1
1 and internal second source
10 MHz–20 GHz 2-port standard test set and internal second source
10 MHz–40 GHz 2-port standard test set
N5230C-220
10 MHz–20 GHz 2-port configurable test set and extended power range N5230C-225
300 kHz–20 GHz 4-port standard test set N5230C-240
300 kHz–20 GHz 4-port configurable test set and extended power range N5230C-245
300 kHz–20 GHz 4-port configurable test set, extended power range N5230C-246
N5230C-420
10 MHz–40 GHz 2-port configurable test set and extended power range N5230C-425
10 MHz–50 GHz 2-port standard test set N5230C-520
10 MHz–50 GHz 2-port configurable test set and extended power range N5230C-525
Measurement applications
Option 010
Option 010
Time domain for 6 GHz model
Time domain for 13.5, 20, 40 or 50 GHz model
Option 080
Option 082
550 2
551
551
2
2
Frequency offset measurements
Scalar-calibrated converter measurements
4-port measurement application
N-port capabilities for 6, 13.5 or 20 GHz model
N-port capabilities for 40 or 50 GHz model
Accessories
Option 1CM
Option 1CP
N4688A
N4689A
Rack mount kit without handles
Rack mount kit with handles
USB CD R/W drive
N5231C-010
N5230C-010
N5230C-080
N5230C-082
N5230C-550
N5231C-551
N5230C-551
N5230C-1CM
N5230C-1CP
N4688A
N4689A
Calibration documentation
Option 1A7
Option A6J
Option UK6
ISO 17025 compliant calibration
ANSI Z540 compliant calibration
Commercial calibration certificate with test data
Calibration software for self-maintainers
897 3 Perpetual license for built-in performance test software for
Agilent inclusive calibration
898 3 Perpetual license for built-in performance test software for standards compliant calibration
N5230C-1A7
N5230C-A6J
N5230C-UK6
N5230C-897
N5230C-898
Additional information
Option 080 recommended
Option 080 recommended
Option 080 required
Not available on 4-port models.
Requires test set Option xx5 or xx6
Requires test set Option xx5 or xx6
Requires test set Option xx5 or xx6
1. Not available in all countries
2. Option 550 is a subset of 551; therefore they cannot be ordered together. When ordering a test set, select an option to specify the appropriate
interconnect jumper cable set between the analyzer and the test set.
3. Additional hardware required. Please refer to the analyzer’s Service Guide for required service test equipment.
25
PNA-L Series Network Analyzer
The PNA-L is an integrated vector network analyzer equipped with a built-in S-parameter test set, one or two synthesized sources used for device stimulus, a hard disk drive, USB interfaces, and an
8.4” LCD color touch screen display. 40 and 50 GHz models have
2.4 mm ruggedized male 50-ohm connectors, while all other models have 3.5 mm ruggedized male 50-ohm connectors. Included with each instrument is a mouse, keyboard (U.S.) and a 1-year return-to-Agilent service warranty.
Test set and power configuration options
• Standard test set and power range (Option xx0)
The 13.5 and 20 GHz versions are available in 2- or 4-ports.
• Configurable test set and extended power range (Option xx5)
Adds front panel access loops and one or two 60 dB step
attenuators as shown in the figures below. This provides the
capability to improve instrument sensitivity for measuring
even more dynamic range or to add components and other
peripheral instruments for a variety of measurement applications.
• Configurable test set, extended power range and internal
second source (Option x46)
Available with 4-port models only, this option adds an internal
second source, nine front panel access loops and two 60 dB
step attenuators as shown in the figure below. This provides an
additional signal (fixed or swept) for two-tone third-order-intercept
(TOI) and intermodulation testing of amplifiers; or it can be used
as a fast swept-LO signal for fixed-IF testing of mixers and
converters. In either case, sweep speed is more than twenty times
faster than using an external source (Option 080 recommended.
Please note, Option 080 is needed in order to have independent
control of the two internal sources.).
2-port standard test set
4-port standard test set
Source
Reference receiver
R
Switch
D
A
PORT 4
PORT 3
PORT 2
PORT 1
4-port configurable test set and extended power range
Source 60 dB
Reference receiver
R
Switch
D
C
B
A
Source out
Coupler thru
PORT 4
Coupler arm
Receiver D in
Source out
Coupler thru
PORT 3
Coupler arm
Receiver C in
Receiver B in
Coupler arm
PORT 2
Coupler thru
Source out
Receiver A in
Coupler arm
PORT 1
Coupler thru
Source out
Source out
Receiver R in
R1
Reference receiver
Source
Switch/splitter
Reference receiver R2
C
B
A
Measurement receivers
B
4-port configurable test set, extended power range and internal second source
Source 1 Source 2
60 dB 60 dB
Port 1 Port 2
2-port configurable test set and extended power range A
R
B C D
Source out
Rcvr
R1 in
26
SRC out
Cplr thru
60 dB
R1
Reference receiver
Source
Switch/splitter
Reference receiver R2
60 dB
A
Measurement receivers
B
Port 1 Cplr arm
Rcvr
A in
Rcvr
B in
Cplr arm
Port 2 Cplr thru
SRC out
Rcvr
R2 in
Source out
Test port 1 Test port 2 Test port 3 Test port 4
PNA-L Series Network Analyzer
Measurement applications
□
Time domain (Option 010)
This option enables the PNA Series to view reflection and trans-
mission responses in both time or distance domain. Use time
domain to tune filters, gate out the response of fixtures and
cables, characterize the impedance of transmission line, and more.
□
4-port measurement application (Option 550)
Adds multiport analyzer mode to any 2-port PNA-L network
analyzer with configurable test set (Option xx5 or xx6), which
enables full 4-port error correction and measurement capabilities
using an external test set. Only standard measurement class is
available in the multiport analyzer mode.
□
Frequency offset (Option 080)
This option enables the PNA Series to set the source frequency
independently from where the receivers are tuned. This ability
is important for two general classes of devices: mixers (and
converters) and amplifiers.
□
Scalar-calibrated converter measurements (Option 082)
With a simple setup and calibration, this application provides the
highest accuracy for conversion-loss (or gain) measurements by
combining one-port and power-meter calibrations to remove
mismatch errors. Option 080 required.
□
N-port capabilities (Option 551)
Adds multiport analyzer mode to any PNA-L network analyzer
with configurable test set (Options xx5 or xx6), which enables
full N-port error correction and measurement capabilities using
an external test set. Only standard measurement class is avail-
able in the multiport analyzer mode.
27
PNA-L Series Network Analyzer
Upgrade kits
See the analyzer’s Service Guide for more information on
Upgrade kits are available to add options after initial purchase.
To order an upgrade kit for the PNA-L series, order the analyzer’s model number followed by a “U”, then indicate the option to be added (example: N5230CU-010). The serial number of the instrument to be retrofitted is required as part of the order.
□
Time-domain upgrade kit (Option 010)
The serial number of the instrument to be retrofitted must be
specified when ordering this kit. User installable.
□
Frequency-offset upgrade kit (Option 080)
The serial number of the instrument to be retrofitted must be
specified when ordering this kit. User installable.
□
Scalar-calibrated converter measurements (Option 082)
User installable. Option 080 required.
□
4-port measurement application (Option 550)
Enables full 4-port error correction and differential measurements
on a 2-port network analyzer with configurable test set (Option x25).
External test set required. User installable.
□
N-port capabilities (Option 551)
Adds full N-port error correction and measurement capabilities to
PNA-L with configurable test set (Option xx5 or x46). External test
set required. User installable.
□
6 or 13.5 GHz configurable test set & extended power range
□
A to C model upgrade
Order N5230AU-221 for 2-port PNA-L, or N5230AU-241 for
Note:
1.1 GHz CPU is required to upgrade. Please refer to Customer Support Service
Guides for the correct part number http://na.tm.agilent.com/pna/documents.html
□
20 GHz 4-port configurable test set, extended power range &
internal second source upgrade kit (Option 927)
Applicable to 20 GHz 4-port PNA-L (N5230C-245). Upgrade to
configurable test set, extended power range and internal second
source. Includes installation at an Agilent service center.
Option 080 recommended.
□
40 or 50 GHz configurable test set & extended power range
Applicable to 40 or 50 GHz PNA-L (N5230C-420, N5230C-520).
Upgrade to configurable test set and extended power range.
Includes installation at an Agilent service center.
□
Frequency range upgrade from 6 to 13.5 GHz (Option 960)
Applicable to the 6 GHz PNA-L (N5230C-020, N5230C-025).
Includes installation at an Agilent service center.
□
Frequency range upgrade from 13.5 to 20 GHz (Option 966)
Applicable to the 13.5 GHz 4-port PNA-L (N5230C-140,
N5230C-145, N5230C-146). Includes installation at an Agilent
Applicable to 6 or 13.5 GHz PNA-L (N5230C-020, N5230C-120). Upgrade
to configurable test set and extended power range. Includes
□
20 GHz 2-port configurable test set & extended power range
Applicable to 20 GHz PNA-L (N5230C-220) Upgrade to
configurable test set and extended power range. Includes
installation at an Agilent service center.
□
13.5 or 20 GHz 4-port configurable test set & extended power
range upgrade kit (Option 926)
Applicable to 20 GHz 4-port PNA-L (N5230C-140, N5230C-240).
Upgrade to configurable test set and extended power range.
Includes installation at an Agilent service center.
□
13.5 GHz 4-port configurable test set, extended power range &
internal second source upgrade kit (Option 928)
Applicable to 13.5 GHz 4-port PNA-L (N5230C-145). Upgrade to
configurable test set, extended power range and internal second
source. Includes installation at an Agilent service center.
(Option 080 recommended. Please note, Option 080 is needed
in order to have independent control of the two internal sources.)
Calibration Software Licenses
□
Perpetual license for built-in performance test software
for Agilent inclusive cal (Option 897)
Adds built-in performance testing and calibration software
for self-maintainers. Requires additional equipment. See
the analyzer’s Service Guide for more information on
□
Frequency range upgrade from 20 to 40 GHz (Option 971)
Applicable to the 20 GHz PNA-L (N5230C-220). Includes
installation at an Agilent service center.
□
Frequency range upgrade from 20 to 40 GHz (Option 973)
Applicable to the 20 GHz PNA-L (N5230C-225). Includes
installation at an Agilent service center.
□
Frequency range upgrade from 40 to 50 GHz (Option 990)
Applicable to the 40 GHz PNA-L (N5230C-420, N5230C-425).
Includes installation at an Agilent service center.
For additional upgrade paths, contact your Agilent field office.
6 GHz
13.5 GHz x20 x25 x40 x45 x46
020 901
025
960
960
140
125
966
926
145 928
146
966
20 GHz
40 GHz
240
926
225
971
420 941
973
966
245 927
246
50 GHz
990
520 941
525
□
Perpetual license for built-in performance test software
for standards compliant cal (Option 898)
Adds built-in performance testing and calibration software
for self-maintainers. Requires additional equipment.
28
PNA-L upgrade path examples.
Measurement Accessories
A complete list of RF and microwave test accessories is available on our Web site: www.agilent.com/find/accessories
Accessories are available in these connector types:
50 ohm Type-N, 3.5 mm, 7 mm, 2.4 mm, 2.92 mm, 1.85 mm, 1.0 mm, and waveguide. Test port cables and a calibration kit should be added for a complete measurement system. A verification kit is used to verify corrected system performance.
Cables and adapter sets
Agilent offers cables in the following types:
• single cables in semi-rigid and flexible
• cable sets in semi-rigid and flexible
There are also adapter sets available that protect the test port and convert the port to the desired connector interface. These kits contain:
• one male adapter
• one female adapter
To attain the best mechanical rigidity for device connection, use a single cable and the appropriate special adapter set. To attain the greatest flexibility for device connection, use a cable set.
Network analyzer test set
Network analyzer test set
Device under test
Test port adapter
Single cable
Cable set
Device under test
Calibration kits
Coaxial measurements
Mechanical calibration kits include standards, such as opens, shorts and loads, which are measured by the network analyzer for increased measurement accuracy.
Electronic calibration (ECal) kits replace mechanical calibration standards with one solid-state calibration module that is controlled by the network analyzer via USB, to present many different impedances to the test ports. A full two-port calibration can be performed quickly with a single connection. This technique reduces operator errors and connector wear and abrasion.
Choose a calibration kit for each connector type to be used.
Economy, includes:
• open standards (male and female)
• short standards (male and female)
• fixed-termination standards (male and female)
Standard, includes the devices in the economy kit and adds:
• sliding load standards (male and female) or a series of
Precision, includes the devices in the economy kit and adds:
• 50 ohm airline(s) for TRL calibration
• TRL adapters
Waveguide measurements
For waveguide measurements, Agilent offers mechanical calibration kits that include:
• waveguide-to-coax adapters (X, P, K, R, Q, U, V)
• precision waveguide section
• flush short circuit
• fixed terminations
• straight section
29
For devices with 1.0 mm connectors
Mechanical calibration/verification kit
□
85059A DC to 110 GHz precision calibration/verification
kit.
Includes:
85059-60003 1.00 mm (m) short 2.450 mm
85059-60007 1.00 mm (f) short 2.450 mm
85059-60004 1.00 mm (m) short 3.000 mm
85059-60008 1.00 mm (f) short 3.000 mm
85059-60002 1.00 mm (m) short 1.825 mm
85059-60006 1.00 mm (f) short 1.825 mm
85059-60001 1.00 mm (m) short 1.300 mm
85059-60005 1.00 mm (f) short 1.300 mm
85059-60009 1.00 mm male open
85059-60010 1.00 mm female open
85059-60019 1.00 mm male load
85059-60020 1.00 mm female load
85059-60021 1.00 mm lossy delay line
11920-60001 1.00 mm (m) to 1.00 mm (m) adapter
11920-60002 1.00 mm (f) to 1.00 mm (f) adapter
11920-60003 1.00 mm (m) to 1.00 mm (f) adapter
11500-60001 1.00 mm (f) to 1.00 mm (f) 8.8 cm cable
85059-60016 1.00 mm mismatch thru adapter
85059-60017 1.00 mm matched thru adapter
8710-2079
8710-2156
6 mm, 4 in-lb torque wrench
6 mm open end wrench
Cables
□
11500I 1.0 mm (f-f) test port cable (8.8 cm)
□
11500J 1.0 mm (m-f) test port cable (16.0 cm) 1
□
11500K 1.0 mm (m-f) test port cable (20.0 cm) 1
□
11500L 1.0 mm (m-f) test port cable (24.0 cm) 1
Adapter set
□
V281C 1.0 mm(f) to V-band waveguide adapter
□
V281D 1.0 mm (m) to V-band waveguide adapter
□
W281C 1.0 mm (f) to W-band waveguide adapter
□
W281D 1.0 mm (m) to W-band waveguide adapter
□
11920A 1.0 mm (m) to 1.0 mm (m) adapter
□
11920B 1.0 mm (f) to 1.0 mm (f) adapter
□
11920C 1.0 mm (m) to 1.0 mm (f) adapter
□
11921A 1.0 mm (m) to 1.85 mm (m) adapter
□
11921B 1.0 mm (f) to 1.85 mm (f) adapter
□
11921C 1.0 mm (m) to 1.85 mm (f) adapter
□
11921D 1.0 mm (f) to 1.85 mm (m) adapter
□
11922A 1.0 mm (m) to 2.4 mm (m) adapter
□
11922B 1.0 mm (f) to 2.4 mm (f) adapter
□
11922C 1.0 mm (m) to 2.4 mm (f) adapter
□
11922D 1.0 mm (f) to 2.4 mm (m) adapter
□
11923A 1.0 mm (f) connector launch assembly
1. For on-wafer applications, two 11500J/K/L cables are required;
one cable for each test port.
2. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard
30
For devices with 1.85 mm connectors
Mechanical calibration kits
□
85058B standard: DC to 67 GHz.
Includes:
85058-60101 1.85 mm (m) short 5.4 mm
85058-60102 1.85 mm (m) short 6.3 mm
85058-60103 1.85 mm (m) short 7.12 mm
85058-60104 1.85 mm (m) short 7.6 mm
85058-60105 1.85 mm (f) short 5.4 mm
85058-60106 1.85 mm (f) short 6.3 mm
85058-60107 1.85 mm (f) short 7.12 mm
85058-60108 1.85 mm (f) short 7.6 mm
85058-60109 1.85 mm male open
85058-60110 1.85 mm female open
85058-60111 1.85 mm male load
85058-60112 1.85 mm female load
85058-60113 1.85 mm (m) to 1.85 mm (m) adapter
85058-60114 1.85 mm (f) to 1.85 mm (f) adapter
85058-60115 1.85 mm (m) to 1.85 mm (f) adapter
□
85058E economy: DC to 67 GHz.
Includes:
85058-60101 1.85 mm (m) short 5.4 mm
85058-60105 1.85 mm (f) short 5.4 mm
85058-60109 1.85 mm male open
85058-60110 1.85 mm female open
85058-60123 1.85 mm male load
85058-60124 1.85 mm female load
85058-60113 1.85 mm (m) to 1.85 mm (m) adapter
85058-60114 1.85 mm (f) to 1.85 mm (f) adapter
85058-60115 1.85 mm (m) to 1.85 mm (f) adapter
Electronic calibration kits
□
N4694A Microwave ECal: 10 MHz to 67 GHz, 2-ports.
Includes:
N4694-60001 1.85 mm (f) to 1.85 mm (m) ECal module
N4694-60002 1.85 mm (m) to 1.85 mm (m) ECal module
N4694-60003 1.85 mm (f) to 1.85 mm (f) ECal module
85058-60113 1.85 mm (m) to 1.85 mm (m) adapter
85058-60114 1.85 mm (f) to 1.85 mm (f) adapter
Cables
□
N4697E 2 Single, flexible: 1.85 mm (f) to 1.85 mm (f),
96.5 cm, 38 inches
□
N4697F 2 Set, flexible:
One 1.85 mm (f) to 1.85 mm (f) cable, 62.2 cm,
24.5 inches, p/n N4697-60100
One 1.85 mm (f) to 1.85 mm (m) cable, 62.2 cm,
24.5 inches, p/n N4697-60200
□
N4697H 2 Single, flexible: 1.85 mm (f) to
1.85 mm (m), 62.2 cm, 24.5 inches
□
N4421B-B67 Set of 4, flexible: 1.85 mm (f) to
1.85 mm (m), 91.4 cm, 36 inches
Adapter set
□
85130H 1.85 mm 2 to 1.85 mm
For devices with 2.4 mm connectors
Mechanical calibration kits
□
85056A standard: DC to 50 GHz.
Includes:
00901-60003 2.4 mm (m) fixed broadband load
00902-60004 2.4 mm (f) fixed broadband load
00915-60003 2.4 mm (m) sliding load
00915-60004 2.4 mm (f) sliding load
85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
85056-60007 2.4 mm (m) to 2.4 mm (f) adapter
85056-60020 2.4 mm (m) short
85056-60021 2.4 mm (f) short
85056-60022 2.4 mm (m) open
85056-60023 2.4 mm (f) open
□
85056D economy: DC to 50 GHz.
Includes:
00901-60003 2.4 mm (m) fixed broadband load
00902-60004 2.4 mm (f) fixed broadband load
85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
85056-60006 2.4 mm (f) to 2.4 mm (f) adapter
85056-60007 2.4 mm (m) to 2.4 mm (f) adapter
85056-60020 2.4 mm (m) short
85056-60021 2.4 mm (f) short
85056-60022 2.4 mm (m) open
85056-60023 2.4 mm (f) open
Electronic calibration kits
□
N4693A Microwave ECal: 10 MHz to 50 GHz, 2-ports.
Includes:
N4693-60001 2.4 mm (f) to 2.4 mm (m) ECal module
N4693-60002 2.4 mm (m) to 2.4 mm (m) ECal module
N4693-60003 2.4 mm (f) to 2.4 mm (f) ECal module
85056-60005 2.4 mm (m) to 2.4 mm (m) adapter
85056-60007 2.4 mm (f) to 2.4 mm (f) adapter
Cables
Note: Agilent offers the following 2.4 mm test port cables. Adapters will be necessary when using these cables for 2.92 mm measurements.
□
85133C 1 single, semi-rigid: 2.4 mm (f) to PSC-2.4 mm (f),
81 cm, 32 inches
□
85133D 1 set, semi-rigid:
One 2.4 mm (f) to 2.4 mm (m), 53 cm, 21 inches,
One 2.4 mm (f) to 2.4 mm (f), 53 cm, 21 inches,
□
85133E 1 single, flexible: 2.4 mm (f) to PSC-2.4 mm (f),
97 cm, 38 inches
□
85133F 1 set, flexible:
One 2.4 mm (f) to 2.4 mm (f), 63 cm, 25 inches,
One 2.4 mm (f) to 2.4 mm (m), 63 cm, 25 inches,
□
85133G 1 Single, semi-rigid: 2.4 mm (f) to 2.4 mm (m),
53 cm, 21 inches
□
85133H 1 Single, flexible: 2.4 mm (f) to 2.4 mm (m),
63 cm, 25 inches
□
N4421A-B20 Set of 4, flexible: 2.4 mm (f) to 2.4 mm (m),
91.4 cm, 36 inches
1. Special rugged female connector specifically for connecting to the network analyzer test port, but does not mate with a standard male connector.
2. Special rugged female connector specifically for connecting to the network analyzers NMD 2.4 mm test port, but does not mate with standard 2.4 mm male connector
Adapter set
□
85130F 2.4 mm 1 to 3.5 mm
□
85130F 2.5 mm 1 to 3.5 mm
□
85130G 2.4 mm 1 to 2.4 mm
For devices with K connectors (2.92 mm)
Mechanical calibration kits
□
85056KE01 DC to 40 GHz
For use with user supplied 2.9 mm test port cables. 2.92 mm
(K connector) calibration kit with fixed and sliding loads. The
Agilent 85056KE01 calibration kit is an ordering convenience to allow the pass through ordering from Agilent Technologies,
Inc. for the Maury 8770C47 calibration kit.
□
85056KE02 DC to 40 GHz
For use with user supplied 2.92 mm test ports cables. 2.92 mm
(K connector) calibration kit with fixed loads only. The Agilent
85056KE02 calibration kit is an ordering convenience to allow the pass through ordering from Agilent Technologies, Inc. for the Maury 8770D47 calibration kit.
The 85056KE01 and 85056KE02 contains one NMD 2.4 mm
2
(f) to 2.92 mm (f) and one NMD 2.4 mm 2 (f) to 2.92 mm (m) test port adapter to adapt the 2.4 mm test ports of the PNA to 2.92 mm. It also supplies 2.92 mm to 2.92 mm in-series adapters (3 adapters) and a PNA Cal Coefficients on a USB stick. Users must supply their own 2.92 mm or K-connector test port cables. Also included is a 2.92 mm torque wrench.
Maury Microwave Terms and Conditions for Warranty and
Return apply. Maury Microwave Corp. calibration kits are to be returned directly to Maury Microwave for service, repair, or calibration issues and not to Agilent Technologies. For additional information go to www.maurymicrowave.com.
Agilent Technologies does not guarantee the performance of the Maury calibration kits or the system performance when connected to Agilent Microwave PNA Series network analyzers.
Electronic calibration kits
□
N4692A Microwave ECal: 10 MHz to 40 GHz, 2-ports.
Includes:
N4692-60001 2.92 mm (f) to 2.92 mm (m) ECal module
N4692-60002 2.92 mm (m) to 2.92 mm (m) ECal module
N4692-60003 2.92 mm (f) to 2.92 mm (f) ECal module
N4692-60021 2.92 mm (m) to 2.92 mm (m) adapter
N4692-60022 2.92 mm (f) to 2.92 mm (f) adapter
31
Cables
Note: Agilent offers the following 2.4 mm test port cables. Adapters will be necessary when using these cables for 2.92 mm measurements.
□
85133C 1 single, semi-rigid: 2.4 mm (f) to PSC-2.4 mm (f),
81 cm, 32 inches
□
85133D 1 set, semi-rigid:
One 2.4 mm (f) to 2.4 mm (m), 53 cm, 21 inches,
One 2.4 mm (f) to 2.4 mm (f), 53 cm, 21 inches,
□
85133E 1 single, flexible: 2.4 mm (f) to PSC-2.4 mm (f),
97 cm, 38 inches
□
85133F 1 set, flexible:
One 2.4 mm (f) to 2.4 mm (f), 63 cm, 25 inches,
One 2.4 mm (f) to 2.4 mm (m), 63 cm, 25 inches,
□
85133G 1 Single, semi-rigid: 2.4 mm (f) to 2.4 mm (m),
53 cm, 21 inches
□
85133H 1 Single, flexible: 2.4 mm (f) to 2.4 mm (m),
63 cm, 25 inches
□
N4421A-B20 Set of 4, flexible: 2.4 mm (f) to 2.4 mm (m),
91.4 cm, 36 inches
Adapters
□
11904A 2.4 mm (m) to 2.92 mm (m)
□
11904B 2.4 mm (f) to 2.92 mm (f)
□
11904C 2.4 mm (m) to 2.92 mm (f)
□
11904D 2.4 mm (f) to 2.92 mm (m)
□
11904S 2.4 mm to 2.92 mm
Adapter set, contains 4 matched adapters
1. Special rugged female connector specifically for connecting to the network analyzer test port, but does not mate with a standard male connector.
32
For devices with 3.5 mm or SMA connectors
Mechanical calibration kits
□
85052B standard: DC to 26.5 GHz.
Includes:
00902-60003 3.5 mm (m) fixed load
00902-60004 3.5 mm (f) fixed load
00911-60019 3.5 mm (m) sliding load
00911-60020 3.5 mm (f) sliding load
85052-60006 3.5 mm (m) short
85052-60007 3.5 mm (f) short
85052-60008 3.5 mm (m) open
85052-60009 3.5 mm (f) open
85052-60012 3.5 mm (f) to 3.5 mm (f) adapter
85052-60013 3.5 mm (f) to 3.5 mm (m) adapter
85052-60014 3.5 mm (m) to 3.5 mm (m) adapter
□
85052C precision TRL: DC to 26.5 GHz.
Includes:
00902-60003 3.5 mm (m) fixed load
00902-60004 3.5 mm (f) fixed load
85052-60006 3.5 mm (m) short
85052-60007 3.5 mm (f) short
85052-60008 3.5 mm (m) open
85052-60009 3.5 mm (f) open
85052-60032 3.5 mm (f) to 3.5 mm (f) adapter
85052-60033 3.5 mm (m) to 3.5 mm (m) adapter
85052-60034 3.5 mm (f) to 3.5 mm (m) adapter
85052-60035 3.5 mm short TRL line
85052-60036 3.5 mm long TRL line
□
85052D economy: DC to 26.5 GHz.
Includes:
00902-60003 3.5 mm (m) fixed load
00902-60004 3.5 mm (f) fixed load
85052-60006 3.5 mm (m) short
85052-60007 3.5 mm (f) short
85052-60008 3.5 mm (m) open
85052-60009 3.5 mm (f) open
85052-60012 3.5 mm (f) to 3.5 mm (f) adapter
85052-60013 3.5 mm (f) to 3.5 mm (m) adapter
85052-60014 3.5 mm (m) to 3.5 mm (m) adapter
Electronic calibration kits
□
85093C RF ECal: 300 kHz to 9 GHz, 2-ports
Option M0F with:
85093-60008 3.5 mm (f) to 3.5 mm (m) ECal module
Option 00F module with:
85093-60010 3.5 mm (f) to 3.5 mm (f) ECal module
Option 00M module with:
85093-60009 3.5 mm (m) to 3.5 mm (m) ECal module
Option 00A adds:
85052-60012 3.5 mm (m) to 3.5 mm (m) adapter
85052-60014 3.5 mm (f) to 3.5 mm (f) adapter
1. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard
2. For use with E8362C.
85093C-xxx mixed-connector options:
Port A option Port B option
3.5 mm 101 102 Type-N 203 204 7-16 205 206
□
N4431B Microwave ECal: 300 kHz to 13.5 GHz, 4-ports.
Includes:
Option 010 module with:
N4431-60006 4 x 3.5 mm (f) ECal module
N4431B-xxx mixed-connector options:
Connector Port A Port B Port C Port D
3.5 mm (f)
3.5 mm (m)
101
102
Type-N 50 ohm (f) 103
Type-N 50 ohm (m) 104
7-16 (f)
7-16 (m)
105
106
201
202
203
204
205
206
301
302
303
304
305
306
□
N4433A Microwave ECal: 300 kHz to 20 GHz, 4-ports.
Includes:
□
Option 010 module with:
N4433-60003 4 x 3.5 mm (f) ECal module
401
402
403
404
405
406
N4433A-xxx mixed-connector options:
Connector Port A Port B Port C Port D
3.5 mm (f)
3.5 mm (m)
101
102
201
202
301
302
401
402
□
N4691B Microwave ECal: 300 kHz to 26.5 GHz, 2-ports.
Includes:
Option M0F module with:
N4691-60001 3.5 mm (f) to 3.5 mm (m) ECal module
N4691-60002 3.5 mm (m) to 3.5 mm (m) ECal module
N4691-60003 3.5 mm (f) to 3.5 mm (f) ECal module
85052-60012 3.5 mm (m) to 3.5 mm (m) adapter
85052-60014 3.5 mm (f) to 3.5 mm (f) adapter
Cables
□
85131C 1 single, semi-rigid: 3.5 mm (f) to PSC-3.5 mm (f),
81 cm, 32 inches 2
□
85131D 1 set, semi-rigid:
One 3.5 mm (f) to 3.5 mm (m), 53 cm, 21 inches,
One 3.5 mm (f) to PSC-3.5 mm (f), 53 cm, 21 inches,
□
85131E 1 single, flexible: 3.5 mm (f) to PSC-3.5 mm (f),
96.5 cm, 38 inches 2
□
85131F 1 set, flexible:
One 3.5 mm (f) to 3.5 mm (m), 62.2 cm, 24.5 inches,
One 3.5 mm (f) to PSC-3.5 mm (f), 62.2 cm, 24.5 inches,
33
□
85131G 1 single, semi-rigid: 3.5 mm (f) to 3.5 mm (m),
53 cm, 21 inches
□
85131H 1 single, flexible: 3.5 mm (f) to 3.5 mm (m),
62.2 cm, 24.5 inches
□
85134C 1 single, semi-rigid: PSC-3.5 mm (f) to 2.4 mm (f),
81 cm, 32 inches
□
85134D 1 set, semi-rigid:
One 2.4 mm (f) to PSC-3.5 mm (f), 53 cm, 21 inches,
One 2.4 mm (f) to PSC-3.5 mm (m), 53 cm, 21 inches,
□
85134E 1 single, flexible: PSC-3.5 mm (f) to 2.4 mm (f),
96 cm, 38 inches
□
85134F 1 set, flexible:
One 2.4 mm (f) to PSC-3.5 mm (f), 53 cm, 21 inches,
One 2.4 mm (f) to PSC-3.5 mm (m), 53 cm, 21 inches,
□
85134G 1 single, semi-rigid: 2.4 mm (f) to PSC-3.5 mm (m),
53 cm, 21 inches
□
85134H 1 single, flexible: 2.4 mm (f) to PSC-3.5 mm (m),
53 cm, 21 inches
□
N4419A-B20 set of 4, flexible: 3.5 mm (m) to 3.5 mm (f),
91.4 cm, 36 inches
□
Z5623A-B20 set of 4, flexible: 3.5 mm (m) to 3.5 mm (m),
91.4 cm, 36 inches (phase-matched)
Adapter sets
□
85130D 3.5 mm 1 to 3.5 mm
For devices with Type-N connectors
Mechanical calibration kits
□
85054B standard: DC to 18 GHz.
Includes:
00909-60011 Type-N (m) fixed lowband load
00909-60012 Type-N (f) fixed lowband load
85054-60025 Type-N (m) short
85054-60026 Type-N (f) short
85054-60027 Type-N (m) open
85054-60028 Type-N (f) open
85054-60031 Type-N (f) to 7mm adapter
85054-60032 Type-N (m) to 7mm adapter
85054-60037 Type-N (f) to Type-N (f) adapter
85054-60038 Type-N (m) to Type-N (m) adapter
85054-80010 Type-N (f) sliding load
85054-80009 Type-N (m) sliding load
85054-60050 Type-N (f) connector gage
85054-60052 Type-N (f) gage master
85054-60051 Type-N (m) connector gage
85054-60053 Type-N (m) gage master
□
85054D economy: DC to 18 GHz.
Includes:
85054-60025 Type-N (m) short
85054-60026 Type-N (f) short
1. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard
2. For use with E8362C.
34
85054-60027 Type-N (m) open
85054-60028 Type-N (f) open
85054-60031 Type-N (f) to 7mm adapter
85054-60032 Type-N (m) to 7mm adapter
85054-60037 Type-N (f) to Type-N (f) adapter
85054-60038 Type-N (m) to Type-N (m) adapter
85054-60046 Type-N (m) fixed load
85054-60047 Type-N (f) fixed load
Adapter sets
□
85130C 3.5 mm 2 to Type-N
Electronic calibration kits
□
N4431B Microwave ECal: 300 kHz to 13.5 GHz, 4-ports.
Includes:
Option 020 module with:
N4431-60007 4 x Type-N (f) ECal module
N4431B-xxx mixed-connector options:
Connector Port A Port B Port C Port D
3.5 mm (f)
3.5 mm (m)
101
102
201
202
Type-N 50 ohm (f) 103 203
Type-N 50 ohm (m) 104
7-16 (f)
1
204
7-16 (m)
1
106
301
302
303
304
□
N4432A Microwave ECal: 300 kHz to 18 GHz, 4-ports.
Includes:
Option 020 module with:
N4432-60003 4 x Type-N (f) ECal module
401
402
403
404
N4432A-xxx mixed-connector options:
Connector Port A Port B Port C Port D
3.5 mm (f)
3.5 mm (m)
101
102
Type-N 50 ohm (f) 103
Type-N 50 ohm (m) 104
201
202
203
204
301
302
303
304
401
402
403
404
□
N4690B Microwave ECal: 300 kHz to 18 GHz, 2-ports.
Includes:
N4690-60001 Type-N (f) to Type-N (m) ECal module
N4690-60002 Type-N (m) to Type-N (m) ECal module
N4690-60003 Type-N (f) to Type-N (f) ECal module
85054-60037 Type-N (f) to Type-N (f) adapter
85054-60038 Type-N (m) to Type-N (m) adapter
Cables 2
Use the test port cables recommended for devices with 7 mm connectors, and 7 mm to Type-N adapters that are from the
85054B/D Type-N calibration kit (see 7 mm connector section).
For devices with 7 mm connectors
Mechanical calibration kits
□
85050B standard: DC to 18 GHz.
Includes:
00909-60008 7 mm coax termination
85050-60006 7 mm fixed broadband load
85050-80007 7 mm short
85050-80010 7 mm open
85050-80011 7 mm sliding load
□
85050C precision TRL: DC to 18 GHz.
Includes:
00909-60008 7 mm coax termination
85050-60003 7 mm to 7 mm airline
85050-60005 7 mm to 7 mm TRL adapter
85050-60006 7 mm fixed broadband load
85050-80008 7 mm short
85050-80009 7 mm short collet
85050-80010 7 mm open
□
85050D economy: DC to 18 GHz.
Includes:
85050-60006 7 mm fixed broadband load
85050-80007 7 mm short
85050-80010 7 mm open
Electronic calibration kits
□
N4696B Microwave ECal: 300 kHz to 18 GHz, 2-ports,
7mm to 7mm Microwave module
Cables 1
□
85132C single, semi-rigid: 7 mm to 3.5 mm (f),
81 cm, 32 inches 2
□
85132D set, semi-rigid: two 3.5 mm (f) to 7 mm cables,
53 cm each, 21 inches each 2 , p/n 85132-60003
□
85132E single, flexible: 7 mm to 3.5 mm (f),
97.2 cm, 38.25 inches 2
□
85132F set, flexible: two 3.5 mm (f) to 7 mm cables,
62.9 cm each, 24.75 inches each 2 , p/n 85132-60004
□
85135C single, semi-rigid: 7 mm to 2.4 mm (f),
81 cm, 32 inches
□
85135D set, semi-rigid: two 2.4 mm (f) to 7 mm cables,
53 cm each, 21 inches each, p/n 85135-60001
□
85135E single, flexible: 7 mm to 2.4 mm (f),
96 cm, 38 inches
□
85135F set, flexible: two 2.4 mm (f) to 7 mm cables,
53 cm each, 21 inches each, p/n 85135-60002
Adapter sets
□
85130E 2.4 mm 1 to 7 mm
1. For use with E8362C.
2. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard
For devices with waveguide
Mechanical calibration kits
X Band
□
X11644A standard, WR-90: 8.2 to 12.4 GHz. Includes:
00896-60008 X-band standard section
00910-60003 X-band termination
11644-20018 X-band short
11644-20021 X-band shim
□
85132F cable set (set, flexible 7 mm to 3.5 mm,
62.9 cm each, 24.75 inches each 2 )
□
85135F cable set (set, flexible,
7 mm to 2.4 mm, 53 cm each, 21 inches each)
□
X281C adapter (included in calibration kit):
WR-90 to 7 mm
P Band
□
P11644A standard, WR-62: 12.4 to 18 GHz.
Includes:
00896-60007 P-band standard section
00910-60002 P-band termination
11644-20017 P-band short
11644-20020 P-band shim
□
85132F cable set (set, flexible, 7 mm to 3.5 mm,
62.9 cm each, 24.75 inches each 2 )
□
85135F cable set (set, flexible, 7 mm to 2.4 mm,
53 cm each, 21 inches each)
□
P281C adapter (included in calibration kit):
WR-62 to 7 mm
K Band
□
K11644A standard, WR-42: 18 to 26.5 GHz.
Includes:
00896-60006 K-band standard section
00910-60001 K-band termination
11644-20016 K-band short
11644-20019 K-band shim
□
85134F cable set (set, flexible, 3.5 mm to 2.4 mm,
53 cm each, 21 inches each)
□
K281C adapter (included in calibration kit):
WR-42 to 3.5 mm (f)
Option 012 WR-42 to 3.5 mm (m)
R Band
□
R11644A standard, WR-28: 26.5 to 40 GHz.
Includes:
00914-20028 R-band termination
11644-20005 R-band short
11644-20003 R-band shim
11644-60001 R-band 10 cm straight waveguide
11644-60016 R-band 5 cm straight waveguide
□
85133F cable set (set, flexible, 2.4 mm, 53 cm each,
21 inches each)
□
R281A adapter (2.4 mm (f) to WR-28 waveguide
adapter)
□
R281B adapter (2.4 mm (m) to WR-28 waveguide
adapter)
35
Q Band
□
Q11644A standard, WR-22: 33 to 50 GHz.
Includes:
11644-60005 Q-band termination
11644-20004 Q-band short
11644-20001 Q-band shim
11644-60002 Q-band 10 cm straight waveguide
11644-60017 Q-band 5 cm straight waveguide
□
85133F cable set (set, flexible, 2.4 mm, 53 cm each,
21 inches each)
□
Q281A adapter (2.4 mm (f) to WR-22 waveguide adapter)
□
Q281B adapter (2.4 mm (m) to WR-22 waveguide adapter)
U Band
□
U11644A standard, WR-19: 40 to 60 GHz.
Includes:
11644-60006 U-band termination
11644-20004 U-band short
11644-20002 U-band shim
11644-60003 U-band 10 cm straight waveguide
11644-60018 U-band 5 cm straight waveguide
V Band
□
V11644A standard, WR-15: 50 to 75 GHz.
Includes:
11644-60025 V-band termination
11644-20015 V-band short
11644-20013 V-band shim
11644-60012 V-band standard section
Verification kits
All Agilent verification kits include:
• precision Z
0
airline or match thru
• mismatched airline or mismatch thru
• fixed attenuators
• traceable measured data and uncertainties
□
85053B 300 kHz to 26.5 GHz 3.5 mm kit
Includes attenuators, airline and mismatch airline with data on
a 3.5-inch disk for use in confirming accuracy enhanced system
Test procedure is provided in the service manual.
□
85055A 300 kHz to 18 GHz Type-N kit
Includes attenuators, airline and mismatch airline with data on
a 3.5-inch disk for use in confirming accuracy enhanced system
Test procedure is provided in the service manual.
□
85057B 45 MHz to 50 GHz 2.4 mm kit
Includes attenuators, airline and mismatch airline with data on
a 3.5-inch disk for use in confirming accuracy enhanced system
Test procedure is provided in the service manual.
□
85058V 45 MHz to 67 GHz 1.85 mm kit
Includes attenuators, match thru and mismatch thru with data
on a 3.5-inch disk for use in confirming accuracy enhanced
system measurement performance, traceable to national
standards. Test procedure is provided in the service manual.
36
General Accessories
USB
□
N4688A CD-ROM drive
Provides an external read/write CD-ROM drive with a USB cable.
□
N4689A USB hub
Provides a USB hub for connecting additional USB peripherals.
Hard drive
1
□
N8981A spare hard drive with mounting cradle
For E836xA/B and N5230A.
□
N8982A spare hard drive with mounting cradle
For E836xC and N5230C.
□
N5242-60035 spare hard drive
For N5242A with 1.6 GHz Pentium M CPU.
□
N5242-60037 spare CPU board with hard drive
For N5242A with 1.6 GHz Pentium M CPU.
□
N5242-60044 spare hard drive with mounting cradle
For N524xA with 2.0 GHz Core 2 Duo CPU.
Probe
□
85024A high-frequency probe
Provides high-impedance in-circuit test capability from
300 kHz to 3 GHz.
Power meters and sensors
2
Recommended for self support, adjustments and performance tests to verify proper instrument operation.
□
U2000A USB power sensor, 10 MHz to 18 GHz
□
U2001A USB power sensor, 10 MHz to 6 GHz
□
U2002A USB power sensor, 50 MHz to 24 GHz
□
U2004A USB power sensor, 9 kHz to 6 GHz
□
E4418B single-channel power meter
□
E4419B dual-channel power meter
□
8481B power sensor, 10 MHz to 18 GHz, Type-N (m), 25 W
□
8481A power sensor, 10 MHz to 18 GHz, Type-N (m), 100 mW
□
8485A power sensor, 50 MHz to 26.5 GHz, APC-3.5 mm (m),
□
8487A power sensor, 50 MHz to 50 GHz, 2.4 mm, 300 mW
□
8487D power sensor, 50 MHz to 50 GHz, 2.4 mm, 100 mW
□
R8486A power sensor, 26 GHz to 40 GHz, waveguide flange
UG-599/U, 100 mW
□
Q8486A power sensor, 33 GHz to 50 GHz, waveguide flange
UG-383/U, 100 mW
□
U8486A power sensor, 50 GHz to 75 GHz, waveguide flange
UG-385/U, 200 mW avg
□
E4412A CW power sensor, 10 MHz to 18 GHz, Type-N (m), 200 mW
□
E4413A CW power sensor, 50 MHz to 26.5 GHz, 3.5 mm, 200 mW
Amplifiers
□
83006A power amplifier, 10 MHz to 26.5 GHz, 20 dB gain,
power out: +18 dBm to 10 GHz or +16 dBm to 20 GHz or
+14 dBm to 26.5 GHz
□
83017A power amplifier, 50 MHz to 26.5 GHz, 25 dB gain,
power out: +20 dBm to 20 GHz, or +15 dBm to 26.5 GHz
□
83018A power amplifier, 2 to 26.5 GHz, 27 dB gain to 20 GHz
or 23 dB to 26.5 GHz, power out: +24 dBm to 20 GHz or
+21 dBm to 26.5 GHz
□
83020A power amplifier, 2 to 26.5 GHz, 30 dB gain to 20 GHz
or 27 dB to 26.5 GHz, power out: +30 dBm to 20 GHz or
+26 dBm to 26.5 GHz
□
83050A power amplifier, 2 to 50 GHz, 23 dB gain, power out:
+20 dBm to 40 GHz or +17 dBm to 50 GHz
□
83051A power amplifier, 45 MHz to 50 GHz, 23 dB gain power out:
+12 dBm to 45 GHz or +10 dBm to 50 GHz
Couplers
□
87300B coaxial coupler, 1 to 20 GHz, SMA (f), 10 dB coupling
□
87300C coaxial coupler, 1 to 26.5 GHz, 3.5 mm (f), 10 dB coupling
□
87301B coaxial coupler, 10 to 46 GHz, 2.92 mm (f), 10 dB coupling
□
87301D coaxial coupler, 1 to 40 GHz, 2.4 mm (f) or optional
2.92 mm (f), 13 dB coupling
□
87301E coaxial coupler, 2 to 50 GHz, 2.4 mm (f), 10 dB coupling
□
87310B 90 o coaxial coupler, 1 to 18 GHz, SMA (f), 3 dB coupling
Equipment rack accessories
□
E3663AC Rail kit
□
5063-9217 Rack mount kit, for use without handles
(included with Option 1CM)
□
5063-9205 Front handle kit
3
□
5063-9224 Rack mount kit with handles
3
□
5063-9237 Rack mount kit, for use with standard supplied
handles (included with Option 1CP)
3
Monitors
VGA-compatible monitor
Printers
USB, LAN, parallel or serial printers with Microsoft® Windows® printer driver
Interface cables
Choose the appropriate cables to connect each peripheral to the network analyzer.
□
10833A GPIB cable, 1.0 m (3.3 ft)
□
10833B GPIB cable, 2.0 m (6.6 ft)
□
10833D GPIB cable, 0.5 m (1.6 ft)
□
82357B GPIB to USB interface
1. For more information on hard drive, refer to na.tm.agilent.com/pna/
hdnumbers.html
2. For the latest guide to power meters and power sensors, refer to the
Agilent web site: www.agilent.com/find/powermeters
3. Front handles and Option 1CP (rack mount with handles) are not
available for the N5242A.
37
Applications
Material measurements
□
85070E High-Temperature Dielectric Probe Kit
The 85070E enables measurements of the dielectric properties
of materials quickly and conveniently. Measurements made
with this probe are nondestructive and require no sample
preparation. The dielectric probe is well suited for measurements
of liquid, semisolid and flat solid materials. Measurement can be viewed in a variety of formats (ε’ r
, ε” r
, tan δ
or Cole-Cole). The supplied software can be run in the PNA
analyzer or on a PC.
□
85071E Materials Measurement Software
The 85071E materials measurement software calculates the
permittivity and permeability of material samples placed in a
coaxial airline or a rectangular waveguide. The measurement
technique works well for solid materials that can be machined
to fit precisely inside a transmission line. Measurement
results can be viewed in a variety of formats (ε’ r
, ε r
, µ’ r
, µ” r
, tan δ,
or Cole-Cole µ). The software can be run in the PNA analyzer
or on a PC.
Pulsed measurements
1
The pulsed RF measurement capability (Option H08) and IF access
(Option H11), are recommended for pulsed measurements with the PNA Series.
Pulse/pattern generators
Recommended to provide pulse signals and timing to the pulsed
S-parameter text set and MW PNA
□
81104A Pulse/pattern generator, 80 MHz, single-/dual-channel
with one or two Agilent 81105A output modules.
□
81110A Pulse/pattern generator, 165 MHz, single-/dual-channel
with one or two Agilent 81111A output modules.
Note: Each pulse/pattern generator must be ordered with its
configuration.
□
Z5623AH84 Pulsed S-parameter test set, 2 to 40 GHz
Includes two pin switches for bi-directional (forward and
reverse) pulsed-RF stimulus, and two directional couplers for
the reference channels. It does not include internal amplifiers,
but has front panel access loops for switching in external
amplifiers to boost port power in both directions.
□
Z5623AH86 Pulsed S-parameter test set, 2 to 40 GHz
Includes one pin switch to modulate the analyzer’s
internal source in the forward direction, and one directional
coupler for the reference channel. It does not include internal
amplifiers, but has front panel access loops for switching in
an external amplifier to boost port power.
□
Z5623AH87 Pulsed S-parameter test set, 1 to 50 GHz
Includes two pin switches for bi-directional (forward and
reverse) pulsed-RF stimulus. It does not include internal amplifiers,
but has front panel access loops for switching in external
amplifiers to boost port power in both directions.
1. For more details regarding pulsed measurement configurations with the
PNA Series, refer to Agilent’s Web site (www.agilent.com/find/pna)
to download a copy of the Microwave PNA Series Network Analyzer
Configuration Guide for Pulsed Measurements, literature number 5989-7913EN.
38
Agilent Email Updates
www.agilent.com/find/emailupdates
Get the latest information on the products and applications you select. www.lxistandard.org
LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the
LXI consortium.
Agilent Channel Partners
www.agilent.com/find/channelpartners
Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience.
Expand your measurement capabilities with Agilent qualified channel partners
Our channel partners offer accessories and measurement solutions that extend your network analysis capabilities.
For more information about probing equipment and accessories, contact:
Cascade Microtech, Inc
2430 NW 206th Avenue
Beaverton, Oregon 97006, USA
Toll free telephone: 1-800-550-3279
Telephone: (503) 601-1000
Fax: (503) 601-1002
Web site: www.cascademicrotech.com
E-mail: [email protected]
www.agilent.com
Remove
all
doubt
Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts.
You will always have the utmost confidence in your measurements.
For information regarding self maintenance of this product, please contact your Agilent office.
Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management.
For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office.
The complete list is available at:
www.agilent.com/find/contactus
Americas
Latin America 305 269 7500
United States (800) 829-4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Thailand
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
1 800 226 008
For more information on repair and calibration services, go to:
www.agilent.com/find/removealldoubt
Europe & Middle East
Austria 43 (0) 1 360 277 1571
Belgium
Denmark
32 (0) 2 404 93 40
45 70 13 15 15
Finland
France
358 (0) 10 855 2100
0825 010 700*
Product specifications and descriptions in this document subject to change without notice.
Germany
Ireland
Israel
Italy
Netherlands
49 (0) 7031 464 6333
1890 924 204
972-3-9288-504/544
39 02 92 60 8484
31 (0) 20 547 2111
Spain
Sweden
34 (91) 631 3300
0200-88 22 55
Switzerland 0800 80 53 53
United Kingdom 44 (0) 118 9276201
Other European Countries: www.agilent.com/find/contactus
Revised: October 1, 2009
© Agilent Technologies, Inc. 2009, 2010
Printed in USA, April 19, 2010
5989-7606EN
Pentium ® is a U.S. registered trademark of Intel Corporation.
Microsoft ® and Windows ® are registered trademarks of Microsoft Corporation.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 PNA-X Series Network Analyzer
- 6 PNA-X Noise Figure Options
- 8 Test set and power confi guration options
- 10 Measurement applications
- 11 Nonlinear vector network analysis
- 11 Pulse, antenna, millimeter-wave
- 11 Accessories
- 13 Upgrade kits
- 14 PNA Series Network Analyzer
- 15 Test set and power confi guration options
- 15 Measurement applications
- 16 Pulse, antenna, millimeter-wave
- 16 Accessories
- 16 Confi guration details
- 17 Simplifi ed test set block diagrams
- 23 N5250C millimeter-wave system
- 25 Upgrade kits
- 25 PNA-L Series Network Analyzer
- 26 Test set and power confi guration options
- 27 Measurement applications
- 28 Upgrade kits
- 29 Measurement Accessories
- 29 Calibration kits, cables, adapters
- 30 For devices with 1.0 mm connectors
- 30 For devices with 1.85 mm connectors
- 31 For devices with 2.4 mm connectors
- 31 For devices with K (2.92 mm) connectors
- 34 For devices with 3.5 mm or SMA connectors
- 34 For devices with Type-N connectors
- 35 For devices with 7 mm connectors
- 36 For devices with waveguide
- 36 Verifi cation kits
- 37 General Accessories
- 37 Hard drive
- 37 Probe
- 37 Power meters and sensors
- 37 Amplifi ers
- 37 Couplers
- 37 Equipment rack accessories
- 37 Monitors
- 37 Printers
- 37 Interface cables
- 38 Applications