4-way Ceiling Cassette

PLA

PLA-RP60/71

100/125/140BA

(i-see Sensor: optional) optional

4-way Ceiling Cassette

14

Advancements in PLA series improve style and performance for ensured indoor comfort

Conventional model

Wide Airflow

Wide-angle outlets distribute airflow to all corners of the room, ensuring the room is sufficiently cooled/heated. Horizontal airflow and a fan speed reduced by 20% compared to conventional models also contribute to increased comfort for occupants.

PLA-RP

✽ ✽

BA

Less Cold Draught

The horizontal airflow function prevents cold draughts from striking the body directly, thereby keeping the body from becoming over-chilled.

Horizontal airflow prevents draughty feeling

Independent Vane Direction

Setting

Using wired remote controller, set airflow direction for each vane

(manual setting also possible)

Use the wired remote controller to set the airflow pattern of each vane independently. Easily adjust airflow to the interior layout and seasonal

✽ Wired remote controller

(PAR-21MAA/PAR-30MAA) has

Independent Vane Direction Setting.

This function is only available when indoor unit connects with PUHZ series.

Horizontal flow conditions, and ensure an even temperature distribution all the time.

Fixed

Set by remote controller

Vertical flow

Settings can be changed anytime using a wired remote controller.

Wave Airflow Mode for Heating

The airflow direction at each outlet changes intermittently, providing a consistent temperature through-out the room.

● “Wave Airflow” operation image

Vertical flow

Vertical flow

Vertical flow

Vertical flow

Simultaneous horizontal and vertical operation ensure a comfortable room from corner to corner.

● Wave control effect thermograph

Vertical flow Swing mode

Temperature gap with uneven temperature distribution

Temperature gap is decreased, and room is warmed uniformly

Auto Fan Speed Mode

The fan speed is adjusted automatically, thereby maintaining a comfortable room environment at all times. At the start of operation, a high fan speed realises quick heating/cooling of the room. Once the desired temperature is reached, the fan speed is reduced for stable heating/cooling and greater comfort.

Fan speed setting by remote controller (four levels)

Lo Mi1 Mi2 Hi Auto

✽ Special setting is required for wireless remote controller.

Quiet Operation

An improved airflow path and powerful highcapacity flow fan contribute to the realisation of quieter operation.

Power flow fan

“Pure White” Colour

Stylish, pure white-coloured panels and wired remote controller express a clean, streamlined image that is a suitable match for any interior.

Other Features

• Stylish indoor-unit vane covers (when unit is turned off)

• Maximum upward draining of 850mm

• Wireless remote controller available

• Duct flange for Fresh-air Intake

• Branch duct

Automatic elevation to four metres

Automatic Grille Lowering

Function (Option)

Easy to use/Simple maintenance

An automatic grille lowering function capable of stopping at eight different heights is available to simplify filter maintenance.

Elevating (up-down) controller

Packaged elevating (up-down) controller in the grille (PLP-6BAJ) can be used when outdoor unit is both PUHZ series and SUZ series.

Wired remote controller

(PAR-21MAA/PAR-30MAA) has automatic grille lowering function.

This function is only available when indoor unit connects with

PUHZ series.

1.2m

1.6m

2.0m

2.4m

2.8m

3.2m

3.6m

4.0m

Specifications: 4-way ceiling-cassette (PLA)

Indoor unit

Outdoor unit

Function

Capacity (min.-max.)

Input

(kW)

(kW)

Rated EER/COP

Rated AEER/ACOP

AEER/ACOP (part-load %) ✽

Indoor unit

Power supply

Airflow (Lo-Mi2-Mid-Hi)

Sound pressure level

Dimensions

Weight

Height

Width

Depth

✽ MEPS compliant at part load

CMM

L/S

(dB)

(mm)

(mm)

(mm)

(kg)

PLA-RP60BA

SUZ-KA60VA3

Cooling Heating

6.1 (1.1-6.3)

1.78

3.43

3.36

6.9 (0.9-8.0)

1.97

3.50

3.44

PLA-RP60BA

12-14-16-18

200-233-267-300

28-29-31-32

PLA-RP71BA

SUZ-KA71VA3

Cooling Heating

7.1 (0.9-8.1)

2.07

3.43

3.38

8.0 (0.9-10.2)

2.19

3.65

3.60

14-16-18-21

233-267-300-350

28-30-32-34

Unit: 258, Panel: 35

Unit: 23, Panel: 6

PLA-RP71BA

PLA-RP71BA

PUHZ-RP71VHA5

Cooling

3.40

3.22

Heating

7.1 (3.3-8.1) 8.0 (3.5-10.2)

2.09

2.17

3.69

3.49

PLA-RP100BA

PUHZ-RP100V/YKA2

Cooling Heating

10.0 (4.9-11.4)

2.50

4.00

3.67/3.63

11.2 (4.5-14.0)

2.95

3.80

3.54/3.50

PLA-RP125BA

PUHZ-RP125V/YKA2

Cooling Heating

12.5 (5.5-14.0)

3.80

3.29

3.10/3.08

14.0 (5.0-16.0)

3.71

3.77

3.56/3.54

4.13/4.05

PLA-RP125BA

PLA-RP140BA

PUHZ-RP140V/YKA2

Cooling Heating

13.0 (6.2-15.3)

3.97

3.27

3.10/3.08

16.0 (5.7-18.0)

4.43

3.61

3.44/3.42

3.95/3.89

PLA-RP140BA PLA-RP71BA PLA-RP100BA

V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V

14-16-18-21

233-267-300-350

28-30-32-34

20-23-26-30

334-384-434-501

32-34-37-40

22-25-28-31

367-417-467-517

34-36-39-41

Unit: 298, Panel: 35

24-26-29-32

400-434-484-534

36-39-42-44

Unit: 840, Panel: 950

Unit: 840, Panel: 950

Unit: 25, Panel: 6 Unit: 27, Panel: 6

4-way cassettes can be equipped with the i-see Sensor, a radiation-based sensor that monitors floor-level temperatures throughout the room to ensure room comfort. i-see Sensor works to ensure even temperature distribution and save energy (requires optional corner panel)

360°

Floor-level temperature measured throughout the room.

i-see Sensor improves energy efficiency and enhances room comfort

The i-see Sensor is an innovative Mitsubishi Electric technology that uses a radiation-based sensor to monitor temperature throughout the entire room.

When connected to the air conditioner control panel, i-see Sensor works to maximise room comfort through 360° sensing that covers the whole floor space.

■ i-see Sensor Operation

The i-see Sensor rotates 90° and takes 5-second measurements to accurately determine floor-level temperatures on all sides of the room.

90° rotation

90° rotation

90° rotation

5sec measurement

5sec measurement

5sec measurement

5sec measurement

● The i-see Sensor calculates the temperature by measuring the infrared rays emanating from the walls and floors, and measuring the floor-level temperature.

● The sensor rotates 360-degrees once every two minutes when there is significant temperature disparity and once every five minutes when a stable, even temperature has been reached.

“I Feel” Temperature Control

The sensory temperature is calculated by measuring the air-intake temperature and the floor temperature. This technology makes it possible to avoid overcooling or overheating.

Without i-see Sensor

Only intake-air temperature at the ceiling is measured, resulting in uneven temperature distribution.

Indoor temperature

Indoor temperature detecting sensor

With i-see Sensor

Both floor-level and intake-air temperatures are measured, providing operation that creates a comfortable room environment from ceiling to floor.

Indoor temperature

Indoor temperature detecting sensor

Area which the sensor checks

Area which the

“i-see Sensor”

Heating

Set temperature: 23°C without i-see Sensor

37°C

25°C

13°C

Heating

Set temperature: 20°C with i-see Sensor + Auto Fan Speed

37°C

25°C

13°C

13

4-way Ceiling Cassette

PLA

PLA-RP60/71

100/125/140BA

(i-see Sensor: optional) optional

4-way Ceiling Cassette

14

Advancements in PLA series improve style and performance for ensured indoor comfort

Conventional model

Wide Airflow

Wide-angle outlets distribute airflow to all corners of the room, ensuring the room is sufficiently cooled/heated. Horizontal airflow and a fan speed reduced by 20% compared to conventional models also contribute to increased comfort for occupants.

PLA-RP

✽ ✽

BA

Less Cold Draught

The horizontal airflow function prevents cold draughts from striking the body directly, thereby keeping the body from becoming over-chilled.

Horizontal airflow prevents draughty feeling

Independent Vane Direction

Setting

Using wired remote controller, set airflow direction for each vane

(manual setting also possible)

Use the wired remote controller to set the airflow pattern of each vane independently. Easily adjust airflow to the interior layout and seasonal

✽ Wired remote controller

(PAR-21MAA/PAR-30MAA) has

Independent Vane Direction Setting.

This function is only available when indoor unit connects with PUHZ series.

Horizontal flow conditions, and ensure an even temperature distribution all the time.

Fixed

Set by remote controller

Vertical flow

Settings can be changed anytime using a wired remote controller.

Wave Airflow Mode for Heating

The airflow direction at each outlet changes intermittently, providing a consistent temperature through-out the room.

● “Wave Airflow” operation image

Vertical flow

Vertical flow

Vertical flow

Vertical flow

Simultaneous horizontal and vertical operation ensure a comfortable room from corner to corner.

● Wave control effect thermograph

Vertical flow Swing mode

Temperature gap with uneven temperature distribution

Temperature gap is decreased, and room is warmed uniformly

Auto Fan Speed Mode

The fan speed is adjusted automatically, thereby maintaining a comfortable room environment at all times. At the start of operation, a high fan speed realises quick heating/cooling of the room. Once the desired temperature is reached, the fan speed is reduced for stable heating/cooling and greater comfort.

Fan speed setting by remote controller (four levels)

Lo Mi1 Mi2 Hi Auto

✽ Special setting is required for wireless remote controller.

Quiet Operation

An improved airflow path and powerful highcapacity flow fan contribute to the realisation of quieter operation.

Power flow fan

“Pure White” Colour

Stylish, pure white-coloured panels and wired remote controller express a clean, streamlined image that is a suitable match for any interior.

Other Features

• Stylish indoor-unit vane covers (when unit is turned off)

• Maximum upward draining of 850mm

• Wireless remote controller available

• Duct flange for Fresh-air Intake

• Branch duct

Automatic elevation to four metres

Automatic Grille Lowering

Function (Option)

Easy to use/Simple maintenance

An automatic grille lowering function capable of stopping at eight different heights is available to simplify filter maintenance.

Elevating (up-down) controller

Packaged elevating (up-down) controller in the grille (PLP-6BAJ) can be used when outdoor unit is both PUHZ series and SUZ series.

Wired remote controller

(PAR-21MAA/PAR-30MAA) has automatic grille lowering function.

This function is only available when indoor unit connects with

PUHZ series.

1.2m

1.6m

2.0m

2.4m

2.8m

3.2m

3.6m

4.0m

Specifications: 4-way ceiling-cassette (PLA)

Indoor unit

Outdoor unit

Function

Capacity (min.-max.)

Input

(kW)

(kW)

Rated EER/COP

Rated AEER/ACOP

AEER/ACOP (part-load %) ✽

Indoor unit

Power supply

Airflow (Lo-Mi2-Mid-Hi)

Sound pressure level

Dimensions

Weight

Height

Width

Depth

✽ MEPS compliant at part load

CMM

L/S

(dB)

(mm)

(mm)

(mm)

(kg)

PLA-RP60BA

SUZ-KA60VA3

Cooling Heating

6.1 (1.1-6.3)

1.78

3.43

3.36

6.9 (0.9-8.0)

1.97

3.50

3.44

PLA-RP60BA

12-14-16-18

200-233-267-300

28-29-31-32

PLA-RP71BA

SUZ-KA71VA3

Cooling Heating

7.1 (0.9-8.1)

2.07

3.43

3.38

8.0 (0.9-10.2)

2.19

3.65

3.60

14-16-18-21

233-267-300-350

28-30-32-34

Unit: 258, Panel: 35

Unit: 23, Panel: 6

PLA-RP71BA

PLA-RP71BA

PUHZ-RP71VHA5

Cooling

3.40

3.22

Heating

7.1 (3.3-8.1) 8.0 (3.5-10.2)

2.09

2.17

3.69

3.49

PLA-RP100BA

PUHZ-RP100V/YKA2

Cooling Heating

10.0 (4.9-11.4)

2.50

4.00

3.67/3.63

11.2 (4.5-14.0)

2.95

3.80

3.54/3.50

PLA-RP125BA

PUHZ-RP125V/YKA2

Cooling Heating

12.5 (5.5-14.0)

3.80

3.29

3.10/3.08

14.0 (5.0-16.0)

3.71

3.77

3.56/3.54

4.13/4.05

PLA-RP125BA

PLA-RP140BA

PUHZ-RP140V/YKA2

Cooling Heating

13.0 (6.2-15.3)

3.97

3.27

3.10/3.08

16.0 (5.7-18.0)

4.43

3.61

3.44/3.42

3.95/3.89

PLA-RP140BA PLA-RP71BA PLA-RP100BA

V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V

14-16-18-21

233-267-300-350

28-30-32-34

20-23-26-30

334-384-434-501

32-34-37-40

22-25-28-31

367-417-467-517

34-36-39-41

Unit: 298, Panel: 35

24-26-29-32

400-434-484-534

36-39-42-44

Unit: 840, Panel: 950

Unit: 840, Panel: 950

Unit: 25, Panel: 6 Unit: 27, Panel: 6

4-way cassettes can be equipped with the i-see Sensor, a radiation-based sensor that monitors floor-level temperatures throughout the room to ensure room comfort. i-see Sensor works to ensure even temperature distribution and save energy (requires optional corner panel)

360°

Floor-level temperature measured throughout the room.

i-see Sensor improves energy efficiency and enhances room comfort

The i-see Sensor is an innovative Mitsubishi Electric technology that uses a radiation-based sensor to monitor temperature throughout the entire room.

When connected to the air conditioner control panel, i-see Sensor works to maximise room comfort through 360° sensing that covers the whole floor space.

■ i-see Sensor Operation

The i-see Sensor rotates 90° and takes 5-second measurements to accurately determine floor-level temperatures on all sides of the room.

90° rotation

90° rotation

90° rotation

5sec measurement

5sec measurement

5sec measurement

5sec measurement

● The i-see Sensor calculates the temperature by measuring the infrared rays emanating from the walls and floors, and measuring the floor-level temperature.

● The sensor rotates 360-degrees once every two minutes when there is significant temperature disparity and once every five minutes when a stable, even temperature has been reached.

“I Feel” Temperature Control

The sensory temperature is calculated by measuring the air-intake temperature and the floor temperature. This technology makes it possible to avoid overcooling or overheating.

Without i-see Sensor

Only intake-air temperature at the ceiling is measured, resulting in uneven temperature distribution.

Indoor temperature

Indoor temperature detecting sensor

With i-see Sensor

Both floor-level and intake-air temperatures are measured, providing operation that creates a comfortable room environment from ceiling to floor.

Indoor temperature

Indoor temperature detecting sensor

Area which the sensor checks

Area which the

“i-see Sensor”

Heating

Set temperature: 23°C without i-see Sensor

37°C

25°C

13°C

Heating

Set temperature: 20°C with i-see Sensor + Auto Fan Speed

37°C

25°C

13°C

Warm, even heat in winter and cool comfort in summer is only a phone call or click away.

Simply contact your nearest Mitsubishi Electric Specialist today and you can find out all there is to know about how to enhance your living environment. Our specialists are fully qualified to give you all the right advice on which Mitsubishi Electric Air Conditioning System is right for you.

To locate your nearest Mitsubishi Electric Specialist go to our website

http://www.MitsubishiElectric.com.au

They will determine whether a Compact Inverter System or a Power Inverter System best suits your needs, both in comfort and efficiency. You can either visit one of our Specialist’s Showrooms, or they will happily arrange for one of their Consultants to come to your home.

All Mitsubishi Electric Compact and Power Inverter Systems are MEPS (Minimum Efficiency

Performance Standard) Compliant, so you can be sure that they will give you the performance and efficiency that they were designed to deliver.

these products.

AIR CONDITIONING SYSTEMS

L-179-7-C7654-H 1204 Printed in Japan (NLP)

EC97J1132

Revised publication, effective Apr. 2012.

Superseding publication L-179-7-C7654-G Apr. 2011.

Specifications subject to change without notice.

25

Amount of Necessary Refrigerant

Amount of Necessary Refrigerant (R410A: kg)

Piping length

SUZ-KA25

SUZ-KA35

SUZ-KA50

SUZ-KA60

SUZ-KA71

Factory charged

7m

0.8

1.05

1.6

1.8

1.8

10m

0.15

0.15

0.06

0.06

0.165

15m

0.3

0.3

0.16

0.16

0.44

Additional charged

20m

0.45

0.45

0.26

0.26

0.715

25m

0.36

0.36

0.99

Piping length

PUHZ-RP71

PUHZ-RP100/125/140

Piping length

PUHZ-RP170/200

Factory charged

10 - 30m

3.5

5.5

Factory charged

10 - 30m

7.7

31 - 40m

0.6

0.6

31 - 40m

0.9

41 - 50m

1.2

1.2

Additional charged

51 - 60m

1.8

41 - 50m

1.8

Additional charged

51 - 60m

2.7

Calculation

30m

0.46

0.46

1.265

Xg = 30g/m × (length-5)m

Xg = 20g/m × (length-7)m

Xg = 55g/m × (length-7)m

61 - 75m

2.4

61 - 70m

3.6

NOTICE

■ Air conditioners in this brochure contain and operate with refrigerant R410A and synthetic oils.

Before attempting any installation work you must read the installation instructions.

New tools, materials and procedures are required to install these products.

Under Australian Law, only persons suitably licensed are permitted to install and service air conditioning units.

Refer to Country, Commonwealth, State or Territory legislation, regulations and industry codes of practice, before installation of these products.

Recovery and disposal of waste material must comply with Country, Commonwealth, State or Territory guidelines.

■ Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high as this may result in a chemical reaction.

■ When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines.

Do not mix it with any other refrigerant and do not allow air to remain in the lines.

If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards.

The use of any refrigerant other than that specified for the system will cause mechanical failure or system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

26

25

Amount of Necessary Refrigerant

Amount of Necessary Refrigerant (R410A: kg)

Piping length

SUZ-KA25

SUZ-KA35

SUZ-KA50

SUZ-KA60

SUZ-KA71

Factory charged

7m

0.8

1.05

1.6

1.8

1.8

10m

0.15

0.15

0.06

0.06

0.165

15m

0.3

0.3

0.16

0.16

0.44

Additional charged

20m

0.45

0.45

0.26

0.26

0.715

25m

0.36

0.36

0.99

Piping length

PUHZ-RP71

PUHZ-RP100/125/140

Piping length

PUHZ-RP170/200

Factory charged

10 - 30m

3.5

5.5

Factory charged

10 - 30m

7.7

31 - 40m

0.6

0.6

31 - 40m

0.9

41 - 50m

1.2

1.2

Additional charged

51 - 60m

1.8

41 - 50m

1.8

Additional charged

51 - 60m

2.7

Calculation

30m

0.46

0.46

1.265

Xg = 30g/m × (length-5)m

Xg = 20g/m × (length-7)m

Xg = 55g/m × (length-7)m

61 - 75m

2.4

61 - 70m

3.6

NOTICE

■ Air conditioners in this brochure contain and operate with refrigerant R410A and synthetic oils.

Before attempting any installation work you must read the installation instructions.

New tools, materials and procedures are required to install these products.

Under Australian Law, only persons suitably licensed are permitted to install and service air conditioning units.

Refer to Country, Commonwealth, State or Territory legislation, regulations and industry codes of practice, before installation of these products.

Recovery and disposal of waste material must comply with Country, Commonwealth, State or Territory guidelines.

■ Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high as this may result in a chemical reaction.

■ When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines.

Do not mix it with any other refrigerant and do not allow air to remain in the lines.

If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards.

The use of any refrigerant other than that specified for the system will cause mechanical failure or system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.

26

23

Specifications

Specifications: Outdoor Unit

Outdoor unit

External finish

Power supply

Compressor output

Airflow (cooling/heating)

Sound pressure level (dB)

Cooling mode

Silent mode

Heating mode

Sound level

Dimensions

Height

Width

Depth

Weight

Chargeless piping length

Max. piping length

Protection device

Rated running current (cooling/heating)

Breaker size

(kW)

CMM (L /S)

(dB)

(mm)

(mm)

(mm)

(kg)

(m)

(m)

(A)

(A)

PUHZ-RP170V/YKA2 PUHZ-RP200YKA2

Munsell 3.0Y 7.8/1.1

V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V

3.0

V: 127 Y: 131

V: 19.4/23.9 Y: 6.8/8.3

V: 40 Y: 32

3.6

140 (2,330)

58

56

59

76

1,338

1,050

330

136

30

75

Discharge thermo, HP switch

8.2/9.7

32

*Above specifications are for outdoor units only.

Notes for All Specifications

Rating conditions (AS/NZS 3823)

Cooling - Indoor: 27°C (80°F) DB, 19°C (66°F) WB

Outdoor: 35°C (95°F) DB

Heating - Indoor: 20°C (68°F) DB

Outdoor: 7°C (45°F) DB, 6°C (43°F) WB

Refrigerant piping length (one-way): 5m (16ft.)

Total input based on the indicated voltage (indoor/outdoor)

Indoor

50Hz Single-phase, 230V

Outdoor

Single-phase, 230V/ Three-phase, 400V

Guaranteed Operating Range

Cooling

Heating

Upper limit (DB)

Lower limit (DB)

Upper limit (DB)

Lower limit (DB)

25/35

46°C

–10°C

24°C

–15°C

SUZ-KA PUHZ

71/100/125/140/170/200 50/60/71

43°C

–15°C

46°C

–5°C (–15°C )

24°C 21°C

–15°C –20°C

With the optional air protection guide, the operation at –15°C outdoor temperature is possible.

Sound Pressure Level

• Sound pressure measurements were conducted in an anechoic chamber.

• The actual noise level depends on the distance from the unit and the acoustic environment.

Optional Parts

24

Optional Parts

Part name

Air discharge guide

Air outlet shutter plate

Air protection guide

Control/service tool

Centralized drain pan

Drain pump

Drain socket

Flange for fresh-air intake

Liquid refrigerant dryer for pipe ø9.52

MA & Contact terminal interface

M-NET interface

M-NET &Terminal interface

Wireless remote controller

Wireless remote controller signal sender

Wireless remote controller signal receiver

High efficiency filter

Model name Application name

PAC-SG59SG-E

PAC-SH96SG-E

PAC-SH51SP-E

PAC-SH63AG-E

PAC-SH95AG-E

PAC-SK52ST

PAC-SG64DP-E

PAC-SH97DP-E

PAC-SH94DM-E

PAC-SH83DM-E

PAC-SH84DM-E

PAC-SH85DM-E

PAC-KE07DM-E

PAC-SG61DS-E

PAC-SH65OF-E

PAC-SG82DR-E

MAC-397IF-E

MAC-399IF-E

MAC-333IF-E

PAR-FL32MA-E

PAR-SL97A-E

PAR-SA9CA-E

PAR-SA9FA-E

PAC-SH88KF-E

PAC-SH89KF-E

PAC-SH90KF-E

PUHZ-RP71

PUHZ-RP100/125/140/170/200

PLA-RP

PUHZ-RP71

PUHZ-RP100/125/140/170/200

PUHZ-RP71/100/125/140/170/200

PUHZ-RP71

PUHZ-RP100/125/140/170/200

PKA-RP

PCA-RP50KAQ

PCA-RP71/100/125/140KAQ

PCA-RP60KAQ

SEZ-KD

PUHZ-RP71/100/125/140/170/200

PLA-RP

PUHZ-RP

SLZ-KA, SEZ-KD, PLA-RP60/71

PEAD-RP71 *1

*1

, PCA-RP50/60/71 *1

SLZ-KA, SEZ-KD, PLA-RP60/71

PEAD-RP71 *1

*1

, PCA-RP50/60/71 *1

SLZ-KA, SEZ-KD, PLA-RP60/71

PEAD-RP71 *1

*1

, PCA-RP50/60/71 *1

PEAD-RP

SEZ-KD, PLA-RP

SEZ-KD, PEAD-RP

PLA-RP

PCA-RP50KAQ

PCA-RP60/71KAQ

PCA-RP100/125/140KAQ

Part name Model name Application name

High efficiency filter element

Filter box i-see sensor corner panel

Shutter plate

Joint pipe 9.52 12.7

15.88 19.05

M-NET converter

Multi-function casement

Power supply terminal kit

PAC-SH59KF-E

PAC-KE93TB-E

PAC-KE94TB-E

PAC-KE95TB-E

PAC-SA1ME-E

PAC-SH51SP-E

PAC-SG73RJ-E

PAC-SG75RJ-E

PAC-SF81MA-E

PAC-SH53TM-E

PAC-SG94HR-E

PAC-SG96HR-E

PAC-SG97HR-E

PAC-SH52HR-E

PAC-SE55RA-E

PAC-SF40RM-E

PAC-SE41TS-E

PAC-SH48AS-E

PAC-SH29TC-E

PLA-RP

PEAD-RP71

PEAD-RP100/125

PEAD-RP140

PLA-RP

PLA-RP

PUHZ-RP71/100/125/140/170/200

PUHZ-RP71/100/125/140

PUHZ-RP71/100/125/140/170/200

PLA-RP

PKA-RP

PCA-RP50/60/71/100/125/140KAQ

PEAD-RP

PLA-RP

All indoor units

All indoor units *2 (excluding PKA-RP)

All indoor units

PLA-RP

PKA-RP for wired remote controller

Remote On/Off adaptor

Remote operation adaptor

Remote sensor

Space panel

Terminal block

Connector cable for remote display

PAC-SA88HA-E All indoor units

Wired remote controller

PAR-30MAA

PAR-21MAA

All indoor units

(excluding SLZ-VAL and SEZ-VAL)

All indoor units

(excluding SLZ-VAL and SEZ-VAL)

Wireless remote controller kit

(Sender & Receiver)

PAR-SL94B-E PCA-RP

Power supply unit

Multiple remote controller adaptor

PAC-SC50KUA

PAC-725AD

All outdoor units

All indoor units

*1 P series indoor units can be used in combination with SUZ outdoor units.

*2 Unable to use with wireless remote controller

Refrigerant Piping

Capacity

SUZ-KA25

Between indoor & outdoor units

Max. height difference (m) Max. piping length (m)

12 20

SUZ-KA35 12 20

SUZ-KA50

SUZ-KA60

SUZ-KA71

PUHZ-RP71

PUHZ-RP100/125/140

PUHZ-RP170/200

30

30

30

30

30

30

30

50

75

30

30

75

Pipe size OD (mm)

Liquid: ø6.35

Gas: ø9.52

Liquid: ø6.35

Gas: ø9.52

Liquid: ø6.35

Gas: ø12.7

Liquid: ø6.35

Gas: ø15.88

Liquid: ø9.52

Gas: ø15.88

Liquid: ø9.52

Gas: ø15.88

Liquid: ø9.52

Gas: ø15.88

Liquid: ø9.52

Gas: ø25.4

Thickness (mm) t 0.8

t 1.0

t 0.8

t 1.0

t 0.8

t 1.0

t 0.8

t 0.8

t 0.8

t 0.8

t 0.8

t 0.8

t 0.8

t 1.0

t 0.8

t 1.0

23

Specifications

Specifications: Outdoor Unit

Outdoor unit

External finish

Power supply

Compressor output

Airflow (cooling/heating)

Sound pressure level (dB)

Cooling mode

Silent mode

Heating mode

Sound level

Dimensions

Height

Width

Depth

Weight

Chargeless piping length

Max. piping length

Protection device

Rated running current (cooling/heating)

Breaker size

(kW)

CMM (L /S)

(dB)

(mm)

(mm)

(mm)

(kg)

(m)

(m)

(A)

(A)

PUHZ-RP170V/YKA2 PUHZ-RP200YKA2

Munsell 3.0Y 7.8/1.1

V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V

3.0

V: 127 Y: 131

V: 19.4/23.9 Y: 6.8/8.3

V: 40 Y: 32

3.6

140 (2,330)

58

56

59

76

1,338

1,050

330

136

30

75

Discharge thermo, HP switch

8.2/9.7

32

*Above specifications are for outdoor units only.

Notes for All Specifications

Rating conditions (AS/NZS 3823)

Cooling - Indoor: 27°C (80°F) DB, 19°C (66°F) WB

Outdoor: 35°C (95°F) DB

Heating - Indoor: 20°C (68°F) DB

Outdoor: 7°C (45°F) DB, 6°C (43°F) WB

Refrigerant piping length (one-way): 5m (16ft.)

Total input based on the indicated voltage (indoor/outdoor)

Indoor

50Hz Single-phase, 230V

Outdoor

Single-phase, 230V/ Three-phase, 400V

Guaranteed Operating Range

Cooling

Heating

Upper limit (DB)

Lower limit (DB)

Upper limit (DB)

Lower limit (DB)

25/35

46°C

–10°C

24°C

–15°C

SUZ-KA PUHZ

71/100/125/140/170/200 50/60/71

43°C

–15°C

46°C

–5°C (–15°C )

24°C 21°C

–15°C –20°C

With the optional air protection guide, the operation at –15°C outdoor temperature is possible.

Sound Pressure Level

• Sound pressure measurements were conducted in an anechoic chamber.

• The actual noise level depends on the distance from the unit and the acoustic environment.

Optional Parts

24

Optional Parts

Part name

Air discharge guide

Air outlet shutter plate

Air protection guide

Control/service tool

Centralized drain pan

Drain pump

Drain socket

Flange for fresh-air intake

Liquid refrigerant dryer for pipe ø9.52

MA & Contact terminal interface

M-NET interface

M-NET &Terminal interface

Wireless remote controller

Wireless remote controller signal sender

Wireless remote controller signal receiver

High efficiency filter

Model name Application name

PAC-SG59SG-E

PAC-SH96SG-E

PAC-SH51SP-E

PAC-SH63AG-E

PAC-SH95AG-E

PAC-SK52ST

PAC-SG64DP-E

PAC-SH97DP-E

PAC-SH94DM-E

PAC-SH83DM-E

PAC-SH84DM-E

PAC-SH85DM-E

PAC-KE07DM-E

PAC-SG61DS-E

PAC-SH65OF-E

PAC-SG82DR-E

MAC-397IF-E

MAC-399IF-E

MAC-333IF-E

PAR-FL32MA-E

PAR-SL97A-E

PAR-SA9CA-E

PAR-SA9FA-E

PAC-SH88KF-E

PAC-SH89KF-E

PAC-SH90KF-E

PUHZ-RP71

PUHZ-RP100/125/140/170/200

PLA-RP

PUHZ-RP71

PUHZ-RP100/125/140/170/200

PUHZ-RP71/100/125/140/170/200

PUHZ-RP71

PUHZ-RP100/125/140/170/200

PKA-RP

PCA-RP50KAQ

PCA-RP71/100/125/140KAQ

PCA-RP60KAQ

SEZ-KD

PUHZ-RP71/100/125/140/170/200

PLA-RP

PUHZ-RP

SLZ-KA, SEZ-KD, PLA-RP60/71 *1

PEAD-RP71 *1 , PCA-RP50/60/71 *1

SLZ-KA, SEZ-KD, PLA-RP60/71 *1

PEAD-RP71 *1 , PCA-RP50/60/71 *1

SLZ-KA, SEZ-KD, PLA-RP60/71 *1

PEAD-RP71 *1 , PCA-RP50/60/71 *1

PEAD-RP

SEZ-KD, PLA-RP

SEZ-KD, PEAD-RP

PLA-RP

PCA-RP50KAQ

PCA-RP60/71KAQ

PCA-RP100/125/140KAQ

Part name Model name Application name

High efficiency filter element

Filter box i-see sensor corner panel

Shutter plate

Joint pipe 9.52 12.7

15.88 19.05

M-NET converter

Multi-function casement

Power supply terminal kit

PAC-SH59KF-E

PAC-KE93TB-E

PAC-KE94TB-E

PAC-KE95TB-E

PAC-SA1ME-E

PAC-SH51SP-E

PAC-SG73RJ-E

PAC-SG75RJ-E

PAC-SF81MA-E

PAC-SH53TM-E

PAC-SG94HR-E

PAC-SG96HR-E

PAC-SG97HR-E

PAC-SH52HR-E

PAC-SE55RA-E

PAC-SF40RM-E

PAC-SE41TS-E

PAC-SH48AS-E

PAC-SH29TC-E

PLA-RP

PEAD-RP71

PEAD-RP100/125

PEAD-RP140

PLA-RP

PLA-RP

PUHZ-RP71/100/125/140/170/200

PUHZ-RP71/100/125/140

PUHZ-RP71/100/125/140/170/200

PLA-RP

PKA-RP

PCA-RP50/60/71/100/125/140KAQ

PEAD-RP

PLA-RP

All indoor units

All indoor units *2 (excluding PKA-RP)

All indoor units

PLA-RP

PKA-RP for wired remote controller

Remote On/Off adaptor

Remote operation adaptor

Remote sensor

Space panel

Terminal block

Connector cable for remote display

PAC-SA88HA-E All indoor units

Wired remote controller

PAR-30MAA

PAR-21MAA

All indoor units

(excluding SLZ-VAL and SEZ-VAL)

All indoor units

(excluding SLZ-VAL and SEZ-VAL)

Wireless remote controller kit

(Sender & Receiver)

PAR-SL94B-E PCA-RP

Power supply unit

Multiple remote controller adaptor

PAC-SC50KUA

PAC-725AD

All outdoor units

All indoor units

*1 P series indoor units can be used in combination with SUZ outdoor units.

*2 Unable to use with wireless remote controller

Refrigerant Piping

Capacity

SUZ-KA25

Between indoor & outdoor units

Max. height difference (m) Max. piping length (m)

12 20

SUZ-KA35 12 20

SUZ-KA50

SUZ-KA60

SUZ-KA71

PUHZ-RP71

PUHZ-RP100/125/140

PUHZ-RP170/200

30

30

30

30

30

30

30

50

75

30

30

75

Pipe size OD (mm)

Liquid: ø6.35

Gas: ø9.52

Liquid: ø6.35

Gas: ø9.52

Liquid: ø6.35

Gas: ø12.7

Liquid: ø6.35

Gas: ø15.88

Liquid: ø9.52

Gas: ø15.88

Liquid: ø9.52

Gas: ø15.88

Liquid: ø9.52

Gas: ø15.88

Liquid: ø9.52

Gas: ø25.4

Thickness (mm) t 0.8

t 1.0

t 0.8

t 1.0

t 0.8

t 1.0

t 0.8

t 0.8

t 0.8

t 0.8

t 0.8

t 0.8

t 0.8

t 1.0

t 0.8

t 1.0

21

System Controls

System Controls (SUZ and Mr. Slim Power Inverter only)

Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc.

MAJOR SYSTEM CONTROL

Indoor Unit

Outdoor Unit

A PAR-30MAA Control

PAR-21MAA Control

System Examples

S Series & P Series Indoor Unit P Series Indoor Unit

S Series Outdoor P Series Outdoor

Details

Standard equipment (for indoor units compatible with wired remote controllers)

Major Optional Parts Required

• PAR-30MAA (Wired remote controller)

• PAR-21MAA (Wired remote controller)

B System Group Control

C

M-NET Connections

PAR-30MAA

PAR-21MAA

MAC-397IF-E

MAC-333IF-E

PAR-30MAA

PAR-21MAA

PAR-30MAA

PAR-21MAA

• One remote controller can control multiple air conditioners with the same settings simultaneously.

• One remote controller can control up to 16 refrigerant systems.

• Up to two remote controller can be connected.

<S Series Outdoor Unit>

• MAC-397IF-E/MAC-333IF-E (Interface)

• PAR-30MAA (Wired remote controller)

• PAR-21MAA (Wired remote controller)

<P Series Outdoor Unit>

• PAR-30MAA (Wired remote controller)

• PAR-21MAA (Wired remote controller)

Outdoor unit

Outdoor unit

Indoor unit Indoor unit

City Multi indoor unit

PAR-30MAA

PAR-21MAA

MAC-399IF-E

MAC-333IF-E

PAR-30MAA

PAR-21MAA

MELANS system controller

(AG-150A etc)

PAC-SC50KA

Power supply unit

PAC-

SC50KUA

Power supply kit

MELANS system controller

(AG-150A etc)

Indoor unit

Indoor unit

PAR-30MAA

PAR-21MAA

PAR-30MAA

PAR-21MAA

M-NET adapter

PAC-SF81MA-E

• Group of air conditioners can be controlled by MELANS system controller (M-NET).

<S Series Outdoor Unit>

• MAC-399IF-E/MAC-333IF-E

• MELANS System controller

• PAC-SC50KUA (power supply unit)

<P Series Outdoor Unit>

• PAC-SF81MA-E (M-NET converter)

• MELANS System controller

• PAC-SC50KUA (power supply unit)

A 2-remote Controller

Control

With two remote controllers, control can be performed locally and remotely from two locations.

B Operation Control by

Level Signal

Air conditioner can be started/ stopped remotely. In addition,

On/Off operation by local remote controller can be prohibited/permitted.

C Operation Control by

Pulse Signal

D Remote Display of

Operating Status

Operating status can be displayed at a remote location.

E Timer Operation

Allows On/Off operation with timer

*For control by an external timer, refer to B Operation

Control by Level Signal.

FOR P SERIES AND S SERIES INDOOR UNITS

System Examples

Wired remote controller Wireless remote controller

Details Major Optional Parts Required

• Up to two remote controllers can be connected to one group.

• Both wired and wireless remote controllers can be used in combination.

• Wired Remote Controller

PAR-30MAA

PAR-21MAA

(for PKA, PAC-SH29TC-E is required)

• Wireless Remote Controller

PAR-SL97A-E (for SEZ and PEAD)

• Wireless Remote Controller Kit for PCA

PAR-SL94B-E

PAR-30MAA

PAR-21MAA

* Set "Main" and "Sub" remote controllers.

(Example of 1 : 1 system)

Relay box (to be purchased) locally)

Adapter for remote

On/Off

Remote control panel Wired remote controller

(Example of 1 : 1 system x 2)

Relay box (to be purchased) locally)

Connector cable for remote display

Remote control panel Wired remote controller

(Example of 1 : 1 system x 2)

Remote operation adapter/

Connector cable for remote display +

Relay box

PAR-SL97A-E

PAR-30MAA

PAR-21MAA

* When using wired and wireless remote controllers

(Example of Simultaneous Twin)

Relay box (to be purchased locally)

Adapter for remote

On/Off

Remote control panel PAR-SL97A-E

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

Connector cable for remote display

Remote control panel PAR-SL97A-E

(Example of 1 : 1 system x 2)

Remote operation adapter/

Connector cable for remote display +

Relay box

• Operation other than On/Off (e.g., adjustment of temperature, fan speed, and airflow) can be performed even when remote controller operation is prohibited.

• Timer control is possible with an external timer.

• Adapter for remote On/Off

PAC-SE55RA-E

• Relay box (to be purchased locally)

• Remote control panel (to be purchased locally)

• The pulse signal can be turned On/Off.

• Operation/emergency signal can be received at a remote location.

• Connector cable for remote display

PAC-SA88HA-E / PAC-725AD

(10 pcs. x PAC-SA88HA-E)

• Relay box (to be purchased locally)

• Remote control panel (to be purchased locally)

Remote display panel

PAR-30/

21MAA

(Example of 1 : 1 system)

Remote display panel

PAR-SL97A-E

(Example of Simultaneous Twin)

• Operation/emergency signal can be received at a remote location (when channeled through the PAC-SF40RM no-voltage signal, when channeled through the PAC-SA88HA-E DC 12V signal).

• Remote display panel (to be purchased locally)

• Connector cable for remote display

PAC-SA88HA-E / PAC-725AD

(10 pcs. x PAC-SA88HA-E)

• Relay box (to be purchased locally)

• Remote operation adapter

PAC-SF40RM

*Unable to use with wireless remote controller

PAR-30MAA

(Example of 1 : 1 system)

• Weekly Timer:

On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)

• On/Off Timer:

On/Off can be set once each within 72 hr in intervals of 5-minute units.

• Auto-off Timer:

Operation will be switched off after a certain time elapse. Set time can be changed from

30 min. to 4 hr. at 10 min. intervals.

*Simple Timer and Auto-off Timer

cannot be used at the same time.

Standard functions of PAR-30MAA

Specifications

22

Specification: Outdoor Unit

Outdoor unit

External finish

Power supply

Compressor output

Airflow (cooling/heating)

Sound pressure level (dB)

(kW)

CMM (L /S)

Cooling mode

Heating mode

Sound level

Dimensions

Weight

Chargeless piping length

Max. piping length

Breaker size

Height

Width

Depth

(dB)

(mm)

(mm)

(mm)

(kg)

(m)

(m)

(A)

SUZ-KA25VA3

0.55

34 (568)/32 (534)

46

46

59

30

550

800

285

SUZ-KA35VA2

0.65

33 (551)

47

48

61

33

SUZ-KA50VA3

Munsell 3.0Y 7.8/1.1

Single-phase, 50Hz, 230V

0.85

49 (818)

53

55

68

850

840

330

53

7

20

10

SUZ-KA60VA3 SUZ-KA71VA3

0.9

51 (850)/49 (816)

50

880

840

330

55

55

69

1.2

50 (835)/48 (800)

53

30

20

*Above specifications are for outdoor units only.

Outdoor unit

External finish

Power supply

Compressor output

Airflow (cooling/heating)

Sound pressure level (dB)

(kW)

CMM (L /S)

Cooling mode

Silent mode

Sound level

Heating mode

Height

(dB)

(mm)

Dimensions Width

Depth

Weight

Chargeless piping length

Max. piping length

Protection device

Rated running current

(cooling/heating)

Breaker size

(mm)

(mm)

(kg)

(m)

(m)

(A)

(A)

1.6

60 (1,000)

47

44

48

66

943

950

330

67

30

50

9.05/9.64

25

PUHZ-RP71VHA5 PUHZ-RP100V/YKA2 PUHZ-RP125V/YKA2

Munsell 3.0Y 7.8/1.1

PUHZ-RP140V/YKA2

V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V

1.9

110 (1,830)

2.4

120 (2,000)

49

46

50

47

52 51

69 70

1,338

2.9

50

47

52

70

1,050

330

V: 118 Y: 119 V: 120 Y: 121

30

75

Discharge thermo, HP switch

V: 12.64/13.58 Y: 4.42/4.75

V: 16.36/16.90 Y: 5.73/5.91

V: 32 Y: 16

V: 17.17/19.23 Y: 6.01/6.73

V: 40 Y: 16

*Above specifications are for outdoor units only.

21

System Controls

System Controls (SUZ and Mr. Slim Power Inverter only)

Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc.

MAJOR SYSTEM CONTROL

Indoor Unit

Outdoor Unit

A PAR-30MAA Control

PAR-21MAA Control

System Examples

S Series & P Series Indoor Unit P Series Indoor Unit

S Series Outdoor P Series Outdoor

Details

Standard equipment (for indoor units compatible with wired remote controllers)

Major Optional Parts Required

• PAR-30MAA (Wired remote controller)

• PAR-21MAA (Wired remote controller)

B System Group Control

C

M-NET Connections

PAR-30MAA

PAR-21MAA

MAC-397IF-E

MAC-333IF-E

PAR-30MAA

PAR-21MAA

PAR-30MAA

PAR-21MAA

• One remote controller can control multiple air conditioners with the same settings simultaneously.

• One remote controller can control up to 16 refrigerant systems.

• Up to two remote controller can be connected.

<S Series Outdoor Unit>

• MAC-397IF-E/MAC-333IF-E (Interface)

• PAR-30MAA (Wired remote controller)

• PAR-21MAA (Wired remote controller)

<P Series Outdoor Unit>

• PAR-30MAA (Wired remote controller)

• PAR-21MAA (Wired remote controller)

Outdoor unit

Outdoor unit

Indoor unit Indoor unit

City Multi indoor unit

PAR-30MAA

PAR-21MAA

MAC-399IF-E

MAC-333IF-E

PAR-30MAA

PAR-21MAA

MELANS system controller

(AG-150A etc)

PAC-SC50KA

Power supply unit

PAC-

SC50KUA

Power supply kit

MELANS system controller

(AG-150A etc)

Indoor unit

Indoor unit

PAR-30MAA

PAR-21MAA

PAR-30MAA

PAR-21MAA

M-NET adapter

PAC-SF81MA-E

• Group of air conditioners can be controlled by MELANS system controller (M-NET).

<S Series Outdoor Unit>

• MAC-399IF-E/MAC-333IF-E

• MELANS System controller

• PAC-SC50KUA (power supply unit)

<P Series Outdoor Unit>

• PAC-SF81MA-E (M-NET converter)

• MELANS System controller

• PAC-SC50KUA (power supply unit)

A 2-remote Controller

Control

With two remote controllers, control can be performed locally and remotely from two locations.

B Operation Control by

Level Signal

Air conditioner can be started/ stopped remotely. In addition,

On/Off operation by local remote controller can be prohibited/permitted.

C Operation Control by

Pulse Signal

D Remote Display of

Operating Status

Operating status can be displayed at a remote location.

E Timer Operation

Allows On/Off operation with timer

*For control by an external timer, refer to B Operation

Control by Level Signal.

FOR P SERIES AND S SERIES INDOOR UNITS

System Examples

Wired remote controller Wireless remote controller

Details Major Optional Parts Required

• Up to two remote controllers can be connected to one group.

• Both wired and wireless remote controllers can be used in combination.

• Wired Remote Controller

PAR-30MAA

PAR-21MAA

(for PKA, PAC-SH29TC-E is required)

• Wireless Remote Controller

PAR-SL97A-E (for SEZ and PEAD)

• Wireless Remote Controller Kit for PCA

PAR-SL94B-E

PAR-30MAA

PAR-21MAA

* Set "Main" and "Sub" remote controllers.

(Example of 1 : 1 system)

Relay box (to be purchased) locally)

Adapter for remote

On/Off

Remote control panel Wired remote controller

(Example of 1 : 1 system x 2)

Relay box (to be purchased) locally)

Connector cable for remote display

Remote control panel Wired remote controller

(Example of 1 : 1 system x 2)

Remote operation adapter/

Connector cable for remote display +

Relay box

PAR-SL97A-E

PAR-30MAA

PAR-21MAA

* When using wired and wireless remote controllers

(Example of Simultaneous Twin)

Relay box (to be purchased locally)

Adapter for remote

On/Off

Remote control panel PAR-SL97A-E

(Example of 1 : 1 system x 2)

Relay box (to be purchased locally)

Connector cable for remote display

Remote control panel PAR-SL97A-E

(Example of 1 : 1 system x 2)

Remote operation adapter/

Connector cable for remote display +

Relay box

• Operation other than On/Off (e.g., adjustment of temperature, fan speed, and airflow) can be performed even when remote controller operation is prohibited.

• Timer control is possible with an external timer.

• Adapter for remote On/Off

PAC-SE55RA-E

• Relay box (to be purchased locally)

• Remote control panel (to be purchased locally)

• The pulse signal can be turned On/Off.

• Operation/emergency signal can be received at a remote location.

• Connector cable for remote display

PAC-SA88HA-E / PAC-725AD

(10 pcs. x PAC-SA88HA-E)

• Relay box (to be purchased locally)

• Remote control panel (to be purchased locally)

Remote display panel

PAR-30/

21MAA

(Example of 1 : 1 system)

Remote display panel

PAR-SL97A-E

(Example of Simultaneous Twin)

• Operation/emergency signal can be received at a remote location (when channeled through the PAC-SF40RM no-voltage signal, when channeled through the PAC-SA88HA-E DC 12V signal).

• Remote display panel (to be purchased locally)

• Connector cable for remote display

PAC-SA88HA-E / PAC-725AD

(10 pcs. x PAC-SA88HA-E)

• Relay box (to be purchased locally)

• Remote operation adapter

PAC-SF40RM

*Unable to use with wireless remote controller

PAR-30MAA

(Example of 1 : 1 system)

• Weekly Timer:

On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)

• On/Off Timer:

On/Off can be set once each within 72 hr in intervals of 5-minute units.

• Auto-off Timer:

Operation will be switched off after a certain time elapse. Set time can be changed from

30 min. to 4 hr. at 10 min. intervals.

*Simple Timer and Auto-off Timer

cannot be used at the same time.

Standard functions of PAR-30MAA

Specifications

22

Specification: Outdoor Unit

Outdoor unit

External finish

Power supply

Compressor output

Airflow (cooling/heating)

Sound pressure level (dB)

(kW)

CMM (L /S)

Cooling mode

Heating mode

Sound level

Dimensions

Weight

Chargeless piping length

Max. piping length

Breaker size

Height

Width

Depth

(dB)

(mm)

(mm)

(mm)

(kg)

(m)

(m)

(A)

SUZ-KA25VA3

0.55

34 (568)/32 (534)

46

46

59

30

550

800

285

SUZ-KA35VA2

0.65

33 (551)

47

48

61

33

SUZ-KA50VA3

Munsell 3.0Y 7.8/1.1

Single-phase, 50Hz, 230V

0.85

49 (818)

53

55

68

850

840

330

53

7

20

10

SUZ-KA60VA3 SUZ-KA71VA3

0.9

51 (850)/49 (816)

50

880

840

330

55

55

69

1.2

50 (835)/48 (800)

53

30

20

*Above specifications are for outdoor units only.

Outdoor unit

External finish

Power supply

Compressor output

Airflow (cooling/heating)

Sound pressure level (dB)

(kW)

CMM (L /S)

Cooling mode

Silent mode

Sound level

Heating mode

Height

(dB)

(mm)

Dimensions Width

Depth

Weight

Chargeless piping length

Max. piping length

Protection device

Rated running current

(cooling/heating)

Breaker size

(mm)

(mm)

(kg)

(m)

(m)

(A)

(A)

1.6

60 (1,000)

47

44

48

66

943

950

330

67

30

50

9.05/9.64

25

PUHZ-RP71VHA5 PUHZ-RP100V/YKA2 PUHZ-RP125V/YKA2

Munsell 3.0Y 7.8/1.1

PUHZ-RP140V/YKA2

V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V

1.9

110 (1,830)

2.4

120 (2,000)

49

46

50

47

52 51

69 70

1,338

2.9

50

47

52

70

1,050

330

V: 118 Y: 119 V: 120 Y: 121

30

75

Discharge thermo, HP switch

V: 12.64/13.58 Y: 4.42/4.75

V: 16.36/16.90 Y: 5.73/5.91

V: 32 Y: 16

V: 17.17/19.23 Y: 6.01/6.73

V: 40 Y: 16

*Above specifications are for outdoor units only.

19 4-way Cassette

Compact Ceiling-concealed

SLZ

SEZ

SEZ-KD25/35/50/

60/71VAQ (L)

SLZ-KA25/50VAQ (L) optional for SLZ/SEZ-VAQ optional for SLZ/SEZ-VAQ standard for

SLZ-VAL standard for

SEZ-VAL

Compact, quiet concealed indoor units equipped with cutting-edge control technologies for enhanced comfort

Compact Designs

Models with capacity ranges for any room size. The dimensions of the SLZ are perfect for 2-metre-square installations, and the SEZ unit is a slim 200mm in height, making it ideal for tight installation spaces.

990mm 700mm

208mm

200mm

650mm 650mm

SLZ-KA25/50 SEZ-KD35/50

Impressively Quiet

S series units offer quiet operation at a hushed noise level of

23dB (SEZ-KD25/35), ensuring a calm and comfortable environment. They’re so quiet that you’ll find yourself checking to see if they’re on.

● Noise level

Subway car interior

Quiet passenger car interior

(40km/h) Library interior

Sound of rustling leaves

Human hearing limits

(Extremely quiet)

80dB 60dB 40dB

23dB

Quiet!

10dB

Energy-saving Operation

Boasting low electricity consumption, SLZ/SEZ series air conditioners are the key to fresh, cost-effective room comfort.

Air Cleaning Filter

This built-in filter removes dust and other particles, keeping the air clean all the time. Maintenance is as simple as vacuuming. The long-life filter in SLZ series air conditioners can be used for approximately 2,500 hours before requiring replacement.

Fresh-air Intake

A duct hole is provided in the main body, making it possible to intake fresh air from outside.

Fresh-air intake

Detail drawing of fresh-air intake

3- 2.8 hole

Burring hole

100

25

73.4

Cut-out hole

12

Electrical box

Refrigerant pipe

Drain pipe

Ceiling surface

12

Specifications: 4-way cassette / Compact ceiling-concealed (SLZ, SEZ)

Indoor unit SLZ-KA25VAQ(L) SLZ-KA50VAQ(L)

Outdoor unit

Function

Capacity (min.-max.)

Input

Rated EER/COP

Rated AEER/ACOP

AEER/ACOP (part-load %) ✽

Indoor unit

Power supply

(kW)

(kW)

SUZ-KA25VA3

Cooling Heating

2.3 (0.9-3.2) 3.1 (0.9-4.5) 4.2 (1.1-5.2) 4.5 (0.9-6.5) 2.5 (0.9-3.2) 3.0 (0.9-4.5)

0.6

3.83

3.65

4.32

0.82

3.78

3.66

SLZ-KA25VAQ(L)

SUZ-KA50VA3

Cooling Heating

1.27

3.31

3.23

1.37

3.28

3.22

SLZ-KA50VAQ(L)

SEZ-KD25VAQ(L)

SUZ-KA25VA3

Cooling

0.75

3.33

3.21

Heating

0.83

3.61

3.49

SEZ-KD25VAQ(L)

SEZ-KD35VAQ(L)

SUZ-KA35VA2

Cooling Heating

3.7 (1.0-3.9) 4.2 (0.9-5.0)

1.09

3.39

3.31

1.13

3.72

3.62

SEZ-KD35VAQ(L)

V: Single-phase, 50Hz, 230V

Airflow (Lo-Mid-Hi)

CMM

L/S

8-9-10

133-150-167

8-9-11

133-150-183

5.5-7-9

92-117-150

7-9-11

117-150-183

External static pressure Pa

Sound pressure level

Supply air spigot size

Height

Dimensions Width

Depth

Weight

(dB)

(mm)

(mm)

(mm)

(mm)

(kg)

28-31-37

30-34-39

Unit: 208, Panel: 20

Unit: 570, Panel: 650

Unit: 570, Panel: 650

Unit: 16.5, Panel: 3

23-26-30

660×150

200

790

700

18

23-28-33

21

SEZ-KD50VAQ(L)

SUZ-KA50VA3

Cooling Heating

SEZ-KD60VAQ(L)

SUZ-KA60VA3

Cooling Heating

SEZ-KD71VAQ(L)

SUZ-KA71VA3

Cooling Heating

5.1 (1.1-5.6) 6.4 (1.1-7.2) 5.6 (1.1-6.3) 7.4 (0.9-8.0) 6.5 (0.9-8.3) 8.1 (0.9-10.4)

1.64

1.81

1.77

2.05

2.06

2.18

3.11

3.05

3.72

3.54

3.48

SEZ-KD50VAQ(L)

3.16

3.11

3.61

3.55

SEZ-KD60VAQ(L)

3.16

3.10

3.72

3.66

SEZ-KD71VAQ(L)

860×150

200

990

700

10-12.5-15

167-208-250

5/15/35/50

30-34-37

23

12-15-18

200-250-300

30-34-38

1,060×150

200

1,190

700

12-16-20

200-267-333

30-35-40

27

✽ MEPS compliant at part load

Main Features

20

Main features of Mr. Slim Inverter Units

Indoor unit SLZ-VA SLZ-VAL SEZ-VA SEZ-VAL

Combination

Energy Saving

Outdoor unit

Felt Temperature Control

(i-see Sensor)

SUZ SUZ SUZ SUZ PUHZ

Opt

PLA

SUZ

Opt

Pure White

Attractive

Auto Vane

PUHZ

PEAD

SUZ

PEA

PUHZ

PKA

PUHZ

PCA-KA

PUHZ SUZ

Air Quality

Fresh-air Intake

High-efficiency Filter

Oil Mist Filter

Long-life filter

Filter Check Signal

Horizontal Vane (Auto Swing)

Air Distribution High Ceiling Mode

Opt Opt

Auto Fan Speed Mode

On/Off Operation Timer

Auto Change Over *1

Auto Restart

Convenience

Low-temperature Cooling

Low-noise Operation (Outdoor Unit)

Rotation, Back-up and 2nd Stage

Cut-in Function

PAR-21MAA Control *2

Centralised On/Off Control *2

Opt

Opt

Opt

Opt

Opt

Opt

Opt

System Control

Opt Opt Opt Opt Opt

Opt System Group Control *2

M-NET Connection *2

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt Opt

Opt

Opt

Opt

Opt

Reuse of Existing Wiring

Drain Pump Opt Opt

Installation

Pump Down Switch

Flare Connection

Self-Diagnosis Function

(Check Code Display)

Maintenance

Failure Recall Function

*1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible.

*2 Please refer “System Control” on page 21 for details.

*3 Not available with PEA-RP140/170/200WJA models.

Opt

Opt

Opt

*3

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

Opt

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement