Mitsubishi Electric PLA-RP100 Specifications
Add to my manuals10 Pages
Mitsubishi Electric PLA-RP100 4-way ceiling cassette air conditioner offers efficient and comfortable cooling and heating solutions for your indoor spaces. Equipped with wide-angle outlets, it ensures even distribution of airflow to all corners of the room, eliminating cold drafts and providing a comfortable environment. The horizontal airflow and reduced fan speed contribute to increased comfort, especially when compared to conventional models.
advertisement
13
4-way Ceiling Cassette
PLA
PLA-RP60/71
100/125/140BA
(i-see Sensor: optional) optional
4-way Ceiling Cassette
14
Advancements in PLA series improve style and performance for ensured indoor comfort
Conventional model
Wide Airflow
Wide-angle outlets distribute airflow to all corners of the room, ensuring the room is sufficiently cooled/heated. Horizontal airflow and a fan speed reduced by 20% compared to conventional models also contribute to increased comfort for occupants.
PLA-RP
✽ ✽
BA
Less Cold Draught
The horizontal airflow function prevents cold draughts from striking the body directly, thereby keeping the body from becoming over-chilled.
Horizontal airflow prevents draughty feeling
Independent Vane Direction
Setting
Using wired remote controller, set airflow direction for each vane
(manual setting also possible)
Use the wired remote controller to set the airflow pattern of each vane independently. Easily adjust airflow to the interior layout and seasonal
✽ Wired remote controller
(PAR-21MAA/PAR-30MAA) has
Independent Vane Direction Setting.
This function is only available when indoor unit connects with PUHZ series.
Horizontal flow conditions, and ensure an even temperature distribution all the time.
Fixed
Set by remote controller
Vertical flow
Settings can be changed anytime using a wired remote controller.
Wave Airflow Mode for Heating
The airflow direction at each outlet changes intermittently, providing a consistent temperature through-out the room.
● “Wave Airflow” operation image
Vertical flow
Vertical flow
Vertical flow
Vertical flow
Simultaneous horizontal and vertical operation ensure a comfortable room from corner to corner.
● Wave control effect thermograph
Vertical flow Swing mode
Temperature gap with uneven temperature distribution
Temperature gap is decreased, and room is warmed uniformly
Auto Fan Speed Mode
The fan speed is adjusted automatically, thereby maintaining a comfortable room environment at all times. At the start of operation, a high fan speed realises quick heating/cooling of the room. Once the desired temperature is reached, the fan speed is reduced for stable heating/cooling and greater comfort.
Fan speed setting by remote controller (four levels)
Lo Mi1 Mi2 Hi Auto
✽ Special setting is required for wireless remote controller.
Quiet Operation
An improved airflow path and powerful highcapacity flow fan contribute to the realisation of quieter operation.
Power flow fan
“Pure White” Colour
Stylish, pure white-coloured panels and wired remote controller express a clean, streamlined image that is a suitable match for any interior.
Other Features
• Stylish indoor-unit vane covers (when unit is turned off)
• Maximum upward draining of 850mm
• Wireless remote controller available
• Duct flange for Fresh-air Intake
• Branch duct
Automatic elevation to four metres
Automatic Grille Lowering
Function (Option)
Easy to use/Simple maintenance
An automatic grille lowering function capable of stopping at eight different heights is available to simplify filter maintenance.
Elevating (up-down) controller
Packaged elevating (up-down) controller in the grille (PLP-6BAJ) can be used when outdoor unit is both PUHZ series and SUZ series.
Wired remote controller
(PAR-21MAA/PAR-30MAA) has automatic grille lowering function.
This function is only available when indoor unit connects with
PUHZ series.
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Specifications: 4-way ceiling-cassette (PLA)
Indoor unit
Outdoor unit
Function
Capacity (min.-max.)
Input
(kW)
(kW)
Rated EER/COP
Rated AEER/ACOP
AEER/ACOP (part-load %) ✽
Indoor unit
Power supply
Airflow (Lo-Mi2-Mid-Hi)
Sound pressure level
Dimensions
Weight
Height
Width
Depth
✽ MEPS compliant at part load
CMM
L/S
(dB)
(mm)
(mm)
(mm)
(kg)
PLA-RP60BA
SUZ-KA60VA3
Cooling Heating
6.1 (1.1-6.3)
1.78
3.43
3.36
6.9 (0.9-8.0)
1.97
3.50
3.44
PLA-RP60BA
12-14-16-18
200-233-267-300
28-29-31-32
PLA-RP71BA
SUZ-KA71VA3
Cooling Heating
7.1 (0.9-8.1)
2.07
3.43
3.38
8.0 (0.9-10.2)
2.19
3.65
3.60
14-16-18-21
233-267-300-350
28-30-32-34
Unit: 258, Panel: 35
Unit: 23, Panel: 6
PLA-RP71BA
PLA-RP71BA
PUHZ-RP71VHA5
Cooling
3.40
3.22
Heating
7.1 (3.3-8.1) 8.0 (3.5-10.2)
2.09
2.17
3.69
3.49
PLA-RP100BA
PUHZ-RP100V/YKA2
Cooling Heating
10.0 (4.9-11.4)
2.50
4.00
3.67/3.63
11.2 (4.5-14.0)
2.95
3.80
3.54/3.50
PLA-RP125BA
PUHZ-RP125V/YKA2
Cooling Heating
12.5 (5.5-14.0)
3.80
3.29
3.10/3.08
14.0 (5.0-16.0)
3.71
3.77
3.56/3.54
4.13/4.05
PLA-RP125BA
PLA-RP140BA
PUHZ-RP140V/YKA2
Cooling Heating
13.0 (6.2-15.3)
3.97
3.27
3.10/3.08
16.0 (5.7-18.0)
4.43
3.61
3.44/3.42
3.95/3.89
PLA-RP140BA PLA-RP71BA PLA-RP100BA
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
14-16-18-21
233-267-300-350
28-30-32-34
20-23-26-30
334-384-434-501
32-34-37-40
22-25-28-31
367-417-467-517
34-36-39-41
Unit: 298, Panel: 35
24-26-29-32
400-434-484-534
36-39-42-44
Unit: 840, Panel: 950
Unit: 840, Panel: 950
Unit: 25, Panel: 6 Unit: 27, Panel: 6
4-way cassettes can be equipped with the i-see Sensor, a radiation-based sensor that monitors floor-level temperatures throughout the room to ensure room comfort. i-see Sensor works to ensure even temperature distribution and save energy (requires optional corner panel)
360°
Floor-level temperature measured throughout the room.
i-see Sensor improves energy efficiency and enhances room comfort
The i-see Sensor is an innovative Mitsubishi Electric technology that uses a radiation-based sensor to monitor temperature throughout the entire room.
When connected to the air conditioner control panel, i-see Sensor works to maximise room comfort through 360° sensing that covers the whole floor space.
■ i-see Sensor Operation
The i-see Sensor rotates 90° and takes 5-second measurements to accurately determine floor-level temperatures on all sides of the room.
90° rotation
90° rotation
90° rotation
5sec measurement
5sec measurement
5sec measurement
5sec measurement
● The i-see Sensor calculates the temperature by measuring the infrared rays emanating from the walls and floors, and measuring the floor-level temperature.
● The sensor rotates 360-degrees once every two minutes when there is significant temperature disparity and once every five minutes when a stable, even temperature has been reached.
“I Feel” Temperature Control
The sensory temperature is calculated by measuring the air-intake temperature and the floor temperature. This technology makes it possible to avoid overcooling or overheating.
Without i-see Sensor
Only intake-air temperature at the ceiling is measured, resulting in uneven temperature distribution.
Indoor temperature
Indoor temperature detecting sensor
With i-see Sensor
Both floor-level and intake-air temperatures are measured, providing operation that creates a comfortable room environment from ceiling to floor.
Indoor temperature
Indoor temperature detecting sensor
Area which the sensor checks
Area which the
“i-see Sensor”
Heating
Set temperature: 23°C without i-see Sensor
37°C
25°C
13°C
Heating
Set temperature: 20°C with i-see Sensor + Auto Fan Speed
37°C
25°C
13°C
13
4-way Ceiling Cassette
PLA
PLA-RP60/71
100/125/140BA
(i-see Sensor: optional) optional
4-way Ceiling Cassette
14
Advancements in PLA series improve style and performance for ensured indoor comfort
Conventional model
Wide Airflow
Wide-angle outlets distribute airflow to all corners of the room, ensuring the room is sufficiently cooled/heated. Horizontal airflow and a fan speed reduced by 20% compared to conventional models also contribute to increased comfort for occupants.
PLA-RP
✽ ✽
BA
Less Cold Draught
The horizontal airflow function prevents cold draughts from striking the body directly, thereby keeping the body from becoming over-chilled.
Horizontal airflow prevents draughty feeling
Independent Vane Direction
Setting
Using wired remote controller, set airflow direction for each vane
(manual setting also possible)
Use the wired remote controller to set the airflow pattern of each vane independently. Easily adjust airflow to the interior layout and seasonal
✽ Wired remote controller
(PAR-21MAA/PAR-30MAA) has
Independent Vane Direction Setting.
This function is only available when indoor unit connects with PUHZ series.
Horizontal flow conditions, and ensure an even temperature distribution all the time.
Fixed
Set by remote controller
Vertical flow
Settings can be changed anytime using a wired remote controller.
Wave Airflow Mode for Heating
The airflow direction at each outlet changes intermittently, providing a consistent temperature through-out the room.
● “Wave Airflow” operation image
Vertical flow
Vertical flow
Vertical flow
Vertical flow
Simultaneous horizontal and vertical operation ensure a comfortable room from corner to corner.
● Wave control effect thermograph
Vertical flow Swing mode
Temperature gap with uneven temperature distribution
Temperature gap is decreased, and room is warmed uniformly
Auto Fan Speed Mode
The fan speed is adjusted automatically, thereby maintaining a comfortable room environment at all times. At the start of operation, a high fan speed realises quick heating/cooling of the room. Once the desired temperature is reached, the fan speed is reduced for stable heating/cooling and greater comfort.
Fan speed setting by remote controller (four levels)
Lo Mi1 Mi2 Hi Auto
✽ Special setting is required for wireless remote controller.
Quiet Operation
An improved airflow path and powerful highcapacity flow fan contribute to the realisation of quieter operation.
Power flow fan
“Pure White” Colour
Stylish, pure white-coloured panels and wired remote controller express a clean, streamlined image that is a suitable match for any interior.
Other Features
• Stylish indoor-unit vane covers (when unit is turned off)
• Maximum upward draining of 850mm
• Wireless remote controller available
• Duct flange for Fresh-air Intake
• Branch duct
Automatic elevation to four metres
Automatic Grille Lowering
Function (Option)
Easy to use/Simple maintenance
An automatic grille lowering function capable of stopping at eight different heights is available to simplify filter maintenance.
Elevating (up-down) controller
Packaged elevating (up-down) controller in the grille (PLP-6BAJ) can be used when outdoor unit is both PUHZ series and SUZ series.
Wired remote controller
(PAR-21MAA/PAR-30MAA) has automatic grille lowering function.
This function is only available when indoor unit connects with
PUHZ series.
1.2m
1.6m
2.0m
2.4m
2.8m
3.2m
3.6m
4.0m
Specifications: 4-way ceiling-cassette (PLA)
Indoor unit
Outdoor unit
Function
Capacity (min.-max.)
Input
(kW)
(kW)
Rated EER/COP
Rated AEER/ACOP
AEER/ACOP (part-load %) ✽
Indoor unit
Power supply
Airflow (Lo-Mi2-Mid-Hi)
Sound pressure level
Dimensions
Weight
Height
Width
Depth
✽ MEPS compliant at part load
CMM
L/S
(dB)
(mm)
(mm)
(mm)
(kg)
PLA-RP60BA
SUZ-KA60VA3
Cooling Heating
6.1 (1.1-6.3)
1.78
3.43
3.36
6.9 (0.9-8.0)
1.97
3.50
3.44
PLA-RP60BA
12-14-16-18
200-233-267-300
28-29-31-32
PLA-RP71BA
SUZ-KA71VA3
Cooling Heating
7.1 (0.9-8.1)
2.07
3.43
3.38
8.0 (0.9-10.2)
2.19
3.65
3.60
14-16-18-21
233-267-300-350
28-30-32-34
Unit: 258, Panel: 35
Unit: 23, Panel: 6
PLA-RP71BA
PLA-RP71BA
PUHZ-RP71VHA5
Cooling
3.40
3.22
Heating
7.1 (3.3-8.1) 8.0 (3.5-10.2)
2.09
2.17
3.69
3.49
PLA-RP100BA
PUHZ-RP100V/YKA2
Cooling Heating
10.0 (4.9-11.4)
2.50
4.00
3.67/3.63
11.2 (4.5-14.0)
2.95
3.80
3.54/3.50
PLA-RP125BA
PUHZ-RP125V/YKA2
Cooling Heating
12.5 (5.5-14.0)
3.80
3.29
3.10/3.08
14.0 (5.0-16.0)
3.71
3.77
3.56/3.54
4.13/4.05
PLA-RP125BA
PLA-RP140BA
PUHZ-RP140V/YKA2
Cooling Heating
13.0 (6.2-15.3)
3.97
3.27
3.10/3.08
16.0 (5.7-18.0)
4.43
3.61
3.44/3.42
3.95/3.89
PLA-RP140BA PLA-RP71BA PLA-RP100BA
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
14-16-18-21
233-267-300-350
28-30-32-34
20-23-26-30
334-384-434-501
32-34-37-40
22-25-28-31
367-417-467-517
34-36-39-41
Unit: 298, Panel: 35
24-26-29-32
400-434-484-534
36-39-42-44
Unit: 840, Panel: 950
Unit: 840, Panel: 950
Unit: 25, Panel: 6 Unit: 27, Panel: 6
4-way cassettes can be equipped with the i-see Sensor, a radiation-based sensor that monitors floor-level temperatures throughout the room to ensure room comfort. i-see Sensor works to ensure even temperature distribution and save energy (requires optional corner panel)
360°
Floor-level temperature measured throughout the room.
i-see Sensor improves energy efficiency and enhances room comfort
The i-see Sensor is an innovative Mitsubishi Electric technology that uses a radiation-based sensor to monitor temperature throughout the entire room.
When connected to the air conditioner control panel, i-see Sensor works to maximise room comfort through 360° sensing that covers the whole floor space.
■ i-see Sensor Operation
The i-see Sensor rotates 90° and takes 5-second measurements to accurately determine floor-level temperatures on all sides of the room.
90° rotation
90° rotation
90° rotation
5sec measurement
5sec measurement
5sec measurement
5sec measurement
● The i-see Sensor calculates the temperature by measuring the infrared rays emanating from the walls and floors, and measuring the floor-level temperature.
● The sensor rotates 360-degrees once every two minutes when there is significant temperature disparity and once every five minutes when a stable, even temperature has been reached.
“I Feel” Temperature Control
The sensory temperature is calculated by measuring the air-intake temperature and the floor temperature. This technology makes it possible to avoid overcooling or overheating.
Without i-see Sensor
Only intake-air temperature at the ceiling is measured, resulting in uneven temperature distribution.
Indoor temperature
Indoor temperature detecting sensor
With i-see Sensor
Both floor-level and intake-air temperatures are measured, providing operation that creates a comfortable room environment from ceiling to floor.
Indoor temperature
Indoor temperature detecting sensor
Area which the sensor checks
Area which the
“i-see Sensor”
Heating
Set temperature: 23°C without i-see Sensor
37°C
25°C
13°C
Heating
Set temperature: 20°C with i-see Sensor + Auto Fan Speed
37°C
25°C
13°C
Warm, even heat in winter and cool comfort in summer is only a phone call or click away.
Simply contact your nearest Mitsubishi Electric Specialist today and you can find out all there is to know about how to enhance your living environment. Our specialists are fully qualified to give you all the right advice on which Mitsubishi Electric Air Conditioning System is right for you.
To locate your nearest Mitsubishi Electric Specialist go to our website
http://www.MitsubishiElectric.com.au
They will determine whether a Compact Inverter System or a Power Inverter System best suits your needs, both in comfort and efficiency. You can either visit one of our Specialist’s Showrooms, or they will happily arrange for one of their Consultants to come to your home.
All Mitsubishi Electric Compact and Power Inverter Systems are MEPS (Minimum Efficiency
Performance Standard) Compliant, so you can be sure that they will give you the performance and efficiency that they were designed to deliver.
these products.
AIR CONDITIONING SYSTEMS
L-179-7-C7654-H 1204 Printed in Japan (NLP)
EC97J1132
Revised publication, effective Apr. 2012.
Superseding publication L-179-7-C7654-G Apr. 2011.
Specifications subject to change without notice.
25
Amount of Necessary Refrigerant
Amount of Necessary Refrigerant (R410A: kg)
Piping length
SUZ-KA25
SUZ-KA35
SUZ-KA50
SUZ-KA60
SUZ-KA71
Factory charged
7m
0.8
1.05
1.6
1.8
1.8
10m
0.15
0.15
0.06
0.06
0.165
15m
0.3
0.3
0.16
0.16
0.44
Additional charged
20m
0.45
0.45
0.26
0.26
0.715
25m
—
—
0.36
0.36
0.99
Piping length
PUHZ-RP71
PUHZ-RP100/125/140
Piping length
PUHZ-RP170/200
Factory charged
10 - 30m
3.5
5.5
Factory charged
10 - 30m
7.7
31 - 40m
0.6
0.6
31 - 40m
0.9
41 - 50m
1.2
1.2
Additional charged
51 - 60m
—
1.8
41 - 50m
1.8
Additional charged
51 - 60m
2.7
Calculation
30m
—
—
0.46
0.46
1.265
Xg = 30g/m × (length-5)m
Xg = 20g/m × (length-7)m
Xg = 55g/m × (length-7)m
61 - 75m
—
2.4
61 - 70m
3.6
NOTICE
■ Air conditioners in this brochure contain and operate with refrigerant R410A and synthetic oils.
Before attempting any installation work you must read the installation instructions.
New tools, materials and procedures are required to install these products.
Under Australian Law, only persons suitably licensed are permitted to install and service air conditioning units.
Refer to Country, Commonwealth, State or Territory legislation, regulations and industry codes of practice, before installation of these products.
Recovery and disposal of waste material must comply with Country, Commonwealth, State or Territory guidelines.
■ Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high as this may result in a chemical reaction.
■ When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure or system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
26
25
Amount of Necessary Refrigerant
Amount of Necessary Refrigerant (R410A: kg)
Piping length
SUZ-KA25
SUZ-KA35
SUZ-KA50
SUZ-KA60
SUZ-KA71
Factory charged
7m
0.8
1.05
1.6
1.8
1.8
10m
0.15
0.15
0.06
0.06
0.165
15m
0.3
0.3
0.16
0.16
0.44
Additional charged
20m
0.45
0.45
0.26
0.26
0.715
25m
—
—
0.36
0.36
0.99
Piping length
PUHZ-RP71
PUHZ-RP100/125/140
Piping length
PUHZ-RP170/200
Factory charged
10 - 30m
3.5
5.5
Factory charged
10 - 30m
7.7
31 - 40m
0.6
0.6
31 - 40m
0.9
41 - 50m
1.2
1.2
Additional charged
51 - 60m
—
1.8
41 - 50m
1.8
Additional charged
51 - 60m
2.7
Calculation
30m
—
—
0.46
0.46
1.265
Xg = 30g/m × (length-5)m
Xg = 20g/m × (length-7)m
Xg = 55g/m × (length-7)m
61 - 75m
—
2.4
61 - 70m
3.6
NOTICE
■ Air conditioners in this brochure contain and operate with refrigerant R410A and synthetic oils.
Before attempting any installation work you must read the installation instructions.
New tools, materials and procedures are required to install these products.
Under Australian Law, only persons suitably licensed are permitted to install and service air conditioning units.
Refer to Country, Commonwealth, State or Territory legislation, regulations and industry codes of practice, before installation of these products.
Recovery and disposal of waste material must comply with Country, Commonwealth, State or Territory guidelines.
■ Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high as this may result in a chemical reaction.
■ When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines.
Do not mix it with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards.
The use of any refrigerant other than that specified for the system will cause mechanical failure or system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
26
23
Specifications
Specifications: Outdoor Unit
Outdoor unit
External finish
Power supply
Compressor output
Airflow (cooling/heating)
Sound pressure level (dB)
Cooling mode
Silent mode
Heating mode
Sound level
Dimensions
Height
Width
Depth
Weight
Chargeless piping length
Max. piping length
Protection device
Rated running current (cooling/heating)
Breaker size
(kW)
CMM (L /S)
(dB)
(mm)
(mm)
(mm)
(kg)
(m)
(m)
(A)
(A)
PUHZ-RP170V/YKA2 PUHZ-RP200YKA2
Munsell 3.0Y 7.8/1.1
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
3.0
V: 127 Y: 131
V: 19.4/23.9 Y: 6.8/8.3
V: 40 Y: 32
3.6
140 (2,330)
58
56
59
76
1,338
1,050
330
136
30
75
Discharge thermo, HP switch
8.2/9.7
32
*Above specifications are for outdoor units only.
Notes for All Specifications
Rating conditions (AS/NZS 3823)
Cooling - Indoor: 27°C (80°F) DB, 19°C (66°F) WB
Outdoor: 35°C (95°F) DB
Heating - Indoor: 20°C (68°F) DB
Outdoor: 7°C (45°F) DB, 6°C (43°F) WB
Refrigerant piping length (one-way): 5m (16ft.)
Total input based on the indicated voltage (indoor/outdoor)
Indoor
50Hz Single-phase, 230V
Outdoor
Single-phase, 230V/ Three-phase, 400V
Guaranteed Operating Range
Cooling
Heating
Upper limit (DB)
Lower limit (DB)
Upper limit (DB)
Lower limit (DB)
25/35
46°C
–10°C
24°C
–15°C
SUZ-KA PUHZ
71/100/125/140/170/200 50/60/71
43°C
–15°C
46°C
–5°C (–15°C )
24°C 21°C
–15°C –20°C
With the optional air protection guide, the operation at –15°C outdoor temperature is possible.
Sound Pressure Level
• Sound pressure measurements were conducted in an anechoic chamber.
• The actual noise level depends on the distance from the unit and the acoustic environment.
Optional Parts
24
Optional Parts
Part name
Air discharge guide
Air outlet shutter plate
Air protection guide
Control/service tool
Centralized drain pan
Drain pump
Drain socket
Flange for fresh-air intake
Liquid refrigerant dryer for pipe ø9.52
MA & Contact terminal interface
M-NET interface
M-NET &Terminal interface
Wireless remote controller
Wireless remote controller signal sender
Wireless remote controller signal receiver
High efficiency filter
Model name Application name
PAC-SG59SG-E
PAC-SH96SG-E
PAC-SH51SP-E
PAC-SH63AG-E
PAC-SH95AG-E
PAC-SK52ST
PAC-SG64DP-E
PAC-SH97DP-E
PAC-SH94DM-E
PAC-SH83DM-E
PAC-SH84DM-E
PAC-SH85DM-E
PAC-KE07DM-E
PAC-SG61DS-E
PAC-SH65OF-E
PAC-SG82DR-E
MAC-397IF-E
MAC-399IF-E
MAC-333IF-E
PAR-FL32MA-E
PAR-SL97A-E
PAR-SA9CA-E
PAR-SA9FA-E
PAC-SH88KF-E
PAC-SH89KF-E
PAC-SH90KF-E
PUHZ-RP71
PUHZ-RP100/125/140/170/200
PLA-RP
PUHZ-RP71
PUHZ-RP100/125/140/170/200
PUHZ-RP71/100/125/140/170/200
PUHZ-RP71
PUHZ-RP100/125/140/170/200
PKA-RP
PCA-RP50KAQ
PCA-RP71/100/125/140KAQ
PCA-RP60KAQ
SEZ-KD
PUHZ-RP71/100/125/140/170/200
PLA-RP
PUHZ-RP
SLZ-KA, SEZ-KD, PLA-RP60/71
PEAD-RP71 *1
*1
, PCA-RP50/60/71 *1
SLZ-KA, SEZ-KD, PLA-RP60/71
PEAD-RP71 *1
*1
, PCA-RP50/60/71 *1
SLZ-KA, SEZ-KD, PLA-RP60/71
PEAD-RP71 *1
*1
, PCA-RP50/60/71 *1
PEAD-RP
SEZ-KD, PLA-RP
SEZ-KD, PEAD-RP
PLA-RP
PCA-RP50KAQ
PCA-RP60/71KAQ
PCA-RP100/125/140KAQ
Part name Model name Application name
High efficiency filter element
Filter box i-see sensor corner panel
Shutter plate
Joint pipe 9.52 12.7
15.88 19.05
M-NET converter
Multi-function casement
Power supply terminal kit
PAC-SH59KF-E
PAC-KE93TB-E
PAC-KE94TB-E
PAC-KE95TB-E
PAC-SA1ME-E
PAC-SH51SP-E
PAC-SG73RJ-E
PAC-SG75RJ-E
PAC-SF81MA-E
PAC-SH53TM-E
PAC-SG94HR-E
PAC-SG96HR-E
PAC-SG97HR-E
PAC-SH52HR-E
PAC-SE55RA-E
PAC-SF40RM-E
PAC-SE41TS-E
PAC-SH48AS-E
PAC-SH29TC-E
PLA-RP
PEAD-RP71
PEAD-RP100/125
PEAD-RP140
PLA-RP
PLA-RP
PUHZ-RP71/100/125/140/170/200
PUHZ-RP71/100/125/140
PUHZ-RP71/100/125/140/170/200
PLA-RP
PKA-RP
PCA-RP50/60/71/100/125/140KAQ
PEAD-RP
PLA-RP
All indoor units
All indoor units *2 (excluding PKA-RP)
All indoor units
PLA-RP
PKA-RP for wired remote controller
Remote On/Off adaptor
Remote operation adaptor
Remote sensor
Space panel
Terminal block
Connector cable for remote display
PAC-SA88HA-E All indoor units
Wired remote controller
PAR-30MAA
PAR-21MAA
All indoor units
(excluding SLZ-VAL and SEZ-VAL)
All indoor units
(excluding SLZ-VAL and SEZ-VAL)
Wireless remote controller kit
(Sender & Receiver)
PAR-SL94B-E PCA-RP
Power supply unit
Multiple remote controller adaptor
PAC-SC50KUA
PAC-725AD
All outdoor units
All indoor units
*1 P series indoor units can be used in combination with SUZ outdoor units.
*2 Unable to use with wireless remote controller
Refrigerant Piping
Capacity
SUZ-KA25
Between indoor & outdoor units
Max. height difference (m) Max. piping length (m)
12 20
SUZ-KA35 12 20
SUZ-KA50
SUZ-KA60
SUZ-KA71
PUHZ-RP71
PUHZ-RP100/125/140
PUHZ-RP170/200
30
30
30
30
30
30
30
50
75
30
30
75
Pipe size OD (mm)
Liquid: ø6.35
Gas: ø9.52
Liquid: ø6.35
Gas: ø9.52
Liquid: ø6.35
Gas: ø12.7
Liquid: ø6.35
Gas: ø15.88
Liquid: ø9.52
Gas: ø15.88
Liquid: ø9.52
Gas: ø15.88
Liquid: ø9.52
Gas: ø15.88
Liquid: ø9.52
Gas: ø25.4
Thickness (mm) t 0.8
t 1.0
t 0.8
t 1.0
t 0.8
t 1.0
t 0.8
t 0.8
t 0.8
t 0.8
t 0.8
t 0.8
t 0.8
t 1.0
t 0.8
t 1.0
23
Specifications
Specifications: Outdoor Unit
Outdoor unit
External finish
Power supply
Compressor output
Airflow (cooling/heating)
Sound pressure level (dB)
Cooling mode
Silent mode
Heating mode
Sound level
Dimensions
Height
Width
Depth
Weight
Chargeless piping length
Max. piping length
Protection device
Rated running current (cooling/heating)
Breaker size
(kW)
CMM (L /S)
(dB)
(mm)
(mm)
(mm)
(kg)
(m)
(m)
(A)
(A)
PUHZ-RP170V/YKA2 PUHZ-RP200YKA2
Munsell 3.0Y 7.8/1.1
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
3.0
V: 127 Y: 131
V: 19.4/23.9 Y: 6.8/8.3
V: 40 Y: 32
3.6
140 (2,330)
58
56
59
76
1,338
1,050
330
136
30
75
Discharge thermo, HP switch
8.2/9.7
32
*Above specifications are for outdoor units only.
Notes for All Specifications
Rating conditions (AS/NZS 3823)
Cooling - Indoor: 27°C (80°F) DB, 19°C (66°F) WB
Outdoor: 35°C (95°F) DB
Heating - Indoor: 20°C (68°F) DB
Outdoor: 7°C (45°F) DB, 6°C (43°F) WB
Refrigerant piping length (one-way): 5m (16ft.)
Total input based on the indicated voltage (indoor/outdoor)
Indoor
50Hz Single-phase, 230V
Outdoor
Single-phase, 230V/ Three-phase, 400V
Guaranteed Operating Range
Cooling
Heating
Upper limit (DB)
Lower limit (DB)
Upper limit (DB)
Lower limit (DB)
25/35
46°C
–10°C
24°C
–15°C
SUZ-KA PUHZ
71/100/125/140/170/200 50/60/71
43°C
–15°C
46°C
–5°C (–15°C )
24°C 21°C
–15°C –20°C
With the optional air protection guide, the operation at –15°C outdoor temperature is possible.
Sound Pressure Level
• Sound pressure measurements were conducted in an anechoic chamber.
• The actual noise level depends on the distance from the unit and the acoustic environment.
Optional Parts
24
Optional Parts
Part name
Air discharge guide
Air outlet shutter plate
Air protection guide
Control/service tool
Centralized drain pan
Drain pump
Drain socket
Flange for fresh-air intake
Liquid refrigerant dryer for pipe ø9.52
MA & Contact terminal interface
M-NET interface
M-NET &Terminal interface
Wireless remote controller
Wireless remote controller signal sender
Wireless remote controller signal receiver
High efficiency filter
Model name Application name
PAC-SG59SG-E
PAC-SH96SG-E
PAC-SH51SP-E
PAC-SH63AG-E
PAC-SH95AG-E
PAC-SK52ST
PAC-SG64DP-E
PAC-SH97DP-E
PAC-SH94DM-E
PAC-SH83DM-E
PAC-SH84DM-E
PAC-SH85DM-E
PAC-KE07DM-E
PAC-SG61DS-E
PAC-SH65OF-E
PAC-SG82DR-E
MAC-397IF-E
MAC-399IF-E
MAC-333IF-E
PAR-FL32MA-E
PAR-SL97A-E
PAR-SA9CA-E
PAR-SA9FA-E
PAC-SH88KF-E
PAC-SH89KF-E
PAC-SH90KF-E
PUHZ-RP71
PUHZ-RP100/125/140/170/200
PLA-RP
PUHZ-RP71
PUHZ-RP100/125/140/170/200
PUHZ-RP71/100/125/140/170/200
PUHZ-RP71
PUHZ-RP100/125/140/170/200
PKA-RP
PCA-RP50KAQ
PCA-RP71/100/125/140KAQ
PCA-RP60KAQ
SEZ-KD
PUHZ-RP71/100/125/140/170/200
PLA-RP
PUHZ-RP
SLZ-KA, SEZ-KD, PLA-RP60/71 *1
PEAD-RP71 *1 , PCA-RP50/60/71 *1
SLZ-KA, SEZ-KD, PLA-RP60/71 *1
PEAD-RP71 *1 , PCA-RP50/60/71 *1
SLZ-KA, SEZ-KD, PLA-RP60/71 *1
PEAD-RP71 *1 , PCA-RP50/60/71 *1
PEAD-RP
SEZ-KD, PLA-RP
SEZ-KD, PEAD-RP
PLA-RP
PCA-RP50KAQ
PCA-RP60/71KAQ
PCA-RP100/125/140KAQ
Part name Model name Application name
High efficiency filter element
Filter box i-see sensor corner panel
Shutter plate
Joint pipe 9.52 12.7
15.88 19.05
M-NET converter
Multi-function casement
Power supply terminal kit
PAC-SH59KF-E
PAC-KE93TB-E
PAC-KE94TB-E
PAC-KE95TB-E
PAC-SA1ME-E
PAC-SH51SP-E
PAC-SG73RJ-E
PAC-SG75RJ-E
PAC-SF81MA-E
PAC-SH53TM-E
PAC-SG94HR-E
PAC-SG96HR-E
PAC-SG97HR-E
PAC-SH52HR-E
PAC-SE55RA-E
PAC-SF40RM-E
PAC-SE41TS-E
PAC-SH48AS-E
PAC-SH29TC-E
PLA-RP
PEAD-RP71
PEAD-RP100/125
PEAD-RP140
PLA-RP
PLA-RP
PUHZ-RP71/100/125/140/170/200
PUHZ-RP71/100/125/140
PUHZ-RP71/100/125/140/170/200
PLA-RP
PKA-RP
PCA-RP50/60/71/100/125/140KAQ
PEAD-RP
PLA-RP
All indoor units
All indoor units *2 (excluding PKA-RP)
All indoor units
PLA-RP
PKA-RP for wired remote controller
Remote On/Off adaptor
Remote operation adaptor
Remote sensor
Space panel
Terminal block
Connector cable for remote display
PAC-SA88HA-E All indoor units
Wired remote controller
PAR-30MAA
PAR-21MAA
All indoor units
(excluding SLZ-VAL and SEZ-VAL)
All indoor units
(excluding SLZ-VAL and SEZ-VAL)
Wireless remote controller kit
(Sender & Receiver)
PAR-SL94B-E PCA-RP
Power supply unit
Multiple remote controller adaptor
PAC-SC50KUA
PAC-725AD
All outdoor units
All indoor units
*1 P series indoor units can be used in combination with SUZ outdoor units.
*2 Unable to use with wireless remote controller
Refrigerant Piping
Capacity
SUZ-KA25
Between indoor & outdoor units
Max. height difference (m) Max. piping length (m)
12 20
SUZ-KA35 12 20
SUZ-KA50
SUZ-KA60
SUZ-KA71
PUHZ-RP71
PUHZ-RP100/125/140
PUHZ-RP170/200
30
30
30
30
30
30
30
50
75
30
30
75
Pipe size OD (mm)
Liquid: ø6.35
Gas: ø9.52
Liquid: ø6.35
Gas: ø9.52
Liquid: ø6.35
Gas: ø12.7
Liquid: ø6.35
Gas: ø15.88
Liquid: ø9.52
Gas: ø15.88
Liquid: ø9.52
Gas: ø15.88
Liquid: ø9.52
Gas: ø15.88
Liquid: ø9.52
Gas: ø25.4
Thickness (mm) t 0.8
t 1.0
t 0.8
t 1.0
t 0.8
t 1.0
t 0.8
t 0.8
t 0.8
t 0.8
t 0.8
t 0.8
t 0.8
t 1.0
t 0.8
t 1.0
21
System Controls
System Controls (SUZ and Mr. Slim Power Inverter only)
Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc.
MAJOR SYSTEM CONTROL
Indoor Unit
Outdoor Unit
A PAR-30MAA Control
PAR-21MAA Control
System Examples
S Series & P Series Indoor Unit P Series Indoor Unit
S Series Outdoor P Series Outdoor
Details
Standard equipment (for indoor units compatible with wired remote controllers)
Major Optional Parts Required
• PAR-30MAA (Wired remote controller)
• PAR-21MAA (Wired remote controller)
B System Group Control
C
M-NET Connections
PAR-30MAA
PAR-21MAA
MAC-397IF-E
MAC-333IF-E
PAR-30MAA
PAR-21MAA
PAR-30MAA
PAR-21MAA
• One remote controller can control multiple air conditioners with the same settings simultaneously.
• One remote controller can control up to 16 refrigerant systems.
• Up to two remote controller can be connected.
<S Series Outdoor Unit>
• MAC-397IF-E/MAC-333IF-E (Interface)
• PAR-30MAA (Wired remote controller)
• PAR-21MAA (Wired remote controller)
<P Series Outdoor Unit>
• PAR-30MAA (Wired remote controller)
• PAR-21MAA (Wired remote controller)
Outdoor unit
Outdoor unit
Indoor unit Indoor unit
City Multi indoor unit
PAR-30MAA
PAR-21MAA
MAC-399IF-E
MAC-333IF-E
PAR-30MAA
PAR-21MAA
MELANS system controller
(AG-150A etc)
PAC-SC50KA
Power supply unit
PAC-
SC50KUA
Power supply kit
MELANS system controller
(AG-150A etc)
Indoor unit
Indoor unit
PAR-30MAA
PAR-21MAA
PAR-30MAA
PAR-21MAA
M-NET adapter
PAC-SF81MA-E
• Group of air conditioners can be controlled by MELANS system controller (M-NET).
<S Series Outdoor Unit>
• MAC-399IF-E/MAC-333IF-E
• MELANS System controller
• PAC-SC50KUA (power supply unit)
<P Series Outdoor Unit>
• PAC-SF81MA-E (M-NET converter)
• MELANS System controller
• PAC-SC50KUA (power supply unit)
A 2-remote Controller
Control
With two remote controllers, control can be performed locally and remotely from two locations.
B Operation Control by
Level Signal
Air conditioner can be started/ stopped remotely. In addition,
On/Off operation by local remote controller can be prohibited/permitted.
C Operation Control by
Pulse Signal
D Remote Display of
Operating Status
Operating status can be displayed at a remote location.
E Timer Operation
Allows On/Off operation with timer
*For control by an external timer, refer to B Operation
Control by Level Signal.
FOR P SERIES AND S SERIES INDOOR UNITS
System Examples
Wired remote controller Wireless remote controller
Details Major Optional Parts Required
• Up to two remote controllers can be connected to one group.
• Both wired and wireless remote controllers can be used in combination.
• Wired Remote Controller
PAR-30MAA
PAR-21MAA
(for PKA, PAC-SH29TC-E is required)
• Wireless Remote Controller
PAR-SL97A-E (for SEZ and PEAD)
• Wireless Remote Controller Kit for PCA
PAR-SL94B-E
PAR-30MAA
PAR-21MAA
* Set "Main" and "Sub" remote controllers.
(Example of 1 : 1 system)
Relay box (to be purchased) locally)
Adapter for remote
On/Off
Remote control panel Wired remote controller
(Example of 1 : 1 system x 2)
Relay box (to be purchased) locally)
Connector cable for remote display
Remote control panel Wired remote controller
(Example of 1 : 1 system x 2)
Remote operation adapter/
Connector cable for remote display +
Relay box
PAR-SL97A-E
PAR-30MAA
PAR-21MAA
* When using wired and wireless remote controllers
(Example of Simultaneous Twin)
Relay box (to be purchased locally)
Adapter for remote
On/Off
Remote control panel PAR-SL97A-E
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
Connector cable for remote display
Remote control panel PAR-SL97A-E
(Example of 1 : 1 system x 2)
Remote operation adapter/
Connector cable for remote display +
Relay box
• Operation other than On/Off (e.g., adjustment of temperature, fan speed, and airflow) can be performed even when remote controller operation is prohibited.
• Timer control is possible with an external timer.
• Adapter for remote On/Off
PAC-SE55RA-E
• Relay box (to be purchased locally)
• Remote control panel (to be purchased locally)
• The pulse signal can be turned On/Off.
• Operation/emergency signal can be received at a remote location.
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote control panel (to be purchased locally)
Remote display panel
PAR-30/
21MAA
(Example of 1 : 1 system)
Remote display panel
PAR-SL97A-E
(Example of Simultaneous Twin)
• Operation/emergency signal can be received at a remote location (when channeled through the PAC-SF40RM no-voltage signal, when channeled through the PAC-SA88HA-E DC 12V signal).
• Remote display panel (to be purchased locally)
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote operation adapter
PAC-SF40RM
*Unable to use with wireless remote controller
PAR-30MAA
(Example of 1 : 1 system)
• Weekly Timer:
On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)
• On/Off Timer:
On/Off can be set once each within 72 hr in intervals of 5-minute units.
• Auto-off Timer:
Operation will be switched off after a certain time elapse. Set time can be changed from
30 min. to 4 hr. at 10 min. intervals.
*Simple Timer and Auto-off Timer
cannot be used at the same time.
Standard functions of PAR-30MAA
Specifications
22
Specification: Outdoor Unit
Outdoor unit
External finish
Power supply
Compressor output
Airflow (cooling/heating)
Sound pressure level (dB)
(kW)
CMM (L /S)
Cooling mode
Heating mode
Sound level
Dimensions
Weight
Chargeless piping length
Max. piping length
Breaker size
Height
Width
Depth
(dB)
(mm)
(mm)
(mm)
(kg)
(m)
(m)
(A)
SUZ-KA25VA3
0.55
34 (568)/32 (534)
46
46
59
30
550
800
285
SUZ-KA35VA2
0.65
33 (551)
47
48
61
33
SUZ-KA50VA3
Munsell 3.0Y 7.8/1.1
Single-phase, 50Hz, 230V
0.85
49 (818)
53
55
68
850
840
330
53
7
20
10
SUZ-KA60VA3 SUZ-KA71VA3
0.9
51 (850)/49 (816)
50
880
840
330
55
55
69
1.2
50 (835)/48 (800)
53
30
20
*Above specifications are for outdoor units only.
Outdoor unit
External finish
Power supply
Compressor output
Airflow (cooling/heating)
Sound pressure level (dB)
(kW)
CMM (L /S)
Cooling mode
Silent mode
Sound level
Heating mode
Height
(dB)
(mm)
Dimensions Width
Depth
Weight
Chargeless piping length
Max. piping length
Protection device
Rated running current
(cooling/heating)
Breaker size
(mm)
(mm)
(kg)
(m)
(m)
(A)
(A)
1.6
60 (1,000)
47
44
48
66
943
950
330
67
30
50
9.05/9.64
25
PUHZ-RP71VHA5 PUHZ-RP100V/YKA2 PUHZ-RP125V/YKA2
Munsell 3.0Y 7.8/1.1
PUHZ-RP140V/YKA2
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
1.9
110 (1,830)
2.4
120 (2,000)
49
46
50
47
52 51
69 70
1,338
2.9
50
47
52
70
1,050
330
V: 118 Y: 119 V: 120 Y: 121
30
75
Discharge thermo, HP switch
V: 12.64/13.58 Y: 4.42/4.75
V: 16.36/16.90 Y: 5.73/5.91
V: 32 Y: 16
V: 17.17/19.23 Y: 6.01/6.73
V: 40 Y: 16
*Above specifications are for outdoor units only.
21
System Controls
System Controls (SUZ and Mr. Slim Power Inverter only)
Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc.
MAJOR SYSTEM CONTROL
Indoor Unit
Outdoor Unit
A PAR-30MAA Control
PAR-21MAA Control
System Examples
S Series & P Series Indoor Unit P Series Indoor Unit
S Series Outdoor P Series Outdoor
Details
Standard equipment (for indoor units compatible with wired remote controllers)
Major Optional Parts Required
• PAR-30MAA (Wired remote controller)
• PAR-21MAA (Wired remote controller)
B System Group Control
C
M-NET Connections
PAR-30MAA
PAR-21MAA
MAC-397IF-E
MAC-333IF-E
PAR-30MAA
PAR-21MAA
PAR-30MAA
PAR-21MAA
• One remote controller can control multiple air conditioners with the same settings simultaneously.
• One remote controller can control up to 16 refrigerant systems.
• Up to two remote controller can be connected.
<S Series Outdoor Unit>
• MAC-397IF-E/MAC-333IF-E (Interface)
• PAR-30MAA (Wired remote controller)
• PAR-21MAA (Wired remote controller)
<P Series Outdoor Unit>
• PAR-30MAA (Wired remote controller)
• PAR-21MAA (Wired remote controller)
Outdoor unit
Outdoor unit
Indoor unit Indoor unit
City Multi indoor unit
PAR-30MAA
PAR-21MAA
MAC-399IF-E
MAC-333IF-E
PAR-30MAA
PAR-21MAA
MELANS system controller
(AG-150A etc)
PAC-SC50KA
Power supply unit
PAC-
SC50KUA
Power supply kit
MELANS system controller
(AG-150A etc)
Indoor unit
Indoor unit
PAR-30MAA
PAR-21MAA
PAR-30MAA
PAR-21MAA
M-NET adapter
PAC-SF81MA-E
• Group of air conditioners can be controlled by MELANS system controller (M-NET).
<S Series Outdoor Unit>
• MAC-399IF-E/MAC-333IF-E
• MELANS System controller
• PAC-SC50KUA (power supply unit)
<P Series Outdoor Unit>
• PAC-SF81MA-E (M-NET converter)
• MELANS System controller
• PAC-SC50KUA (power supply unit)
A 2-remote Controller
Control
With two remote controllers, control can be performed locally and remotely from two locations.
B Operation Control by
Level Signal
Air conditioner can be started/ stopped remotely. In addition,
On/Off operation by local remote controller can be prohibited/permitted.
C Operation Control by
Pulse Signal
D Remote Display of
Operating Status
Operating status can be displayed at a remote location.
E Timer Operation
Allows On/Off operation with timer
*For control by an external timer, refer to B Operation
Control by Level Signal.
FOR P SERIES AND S SERIES INDOOR UNITS
System Examples
Wired remote controller Wireless remote controller
Details Major Optional Parts Required
• Up to two remote controllers can be connected to one group.
• Both wired and wireless remote controllers can be used in combination.
• Wired Remote Controller
PAR-30MAA
PAR-21MAA
(for PKA, PAC-SH29TC-E is required)
• Wireless Remote Controller
PAR-SL97A-E (for SEZ and PEAD)
• Wireless Remote Controller Kit for PCA
PAR-SL94B-E
PAR-30MAA
PAR-21MAA
* Set "Main" and "Sub" remote controllers.
(Example of 1 : 1 system)
Relay box (to be purchased) locally)
Adapter for remote
On/Off
Remote control panel Wired remote controller
(Example of 1 : 1 system x 2)
Relay box (to be purchased) locally)
Connector cable for remote display
Remote control panel Wired remote controller
(Example of 1 : 1 system x 2)
Remote operation adapter/
Connector cable for remote display +
Relay box
PAR-SL97A-E
PAR-30MAA
PAR-21MAA
* When using wired and wireless remote controllers
(Example of Simultaneous Twin)
Relay box (to be purchased locally)
Adapter for remote
On/Off
Remote control panel PAR-SL97A-E
(Example of 1 : 1 system x 2)
Relay box (to be purchased locally)
Connector cable for remote display
Remote control panel PAR-SL97A-E
(Example of 1 : 1 system x 2)
Remote operation adapter/
Connector cable for remote display +
Relay box
• Operation other than On/Off (e.g., adjustment of temperature, fan speed, and airflow) can be performed even when remote controller operation is prohibited.
• Timer control is possible with an external timer.
• Adapter for remote On/Off
PAC-SE55RA-E
• Relay box (to be purchased locally)
• Remote control panel (to be purchased locally)
• The pulse signal can be turned On/Off.
• Operation/emergency signal can be received at a remote location.
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote control panel (to be purchased locally)
Remote display panel
PAR-30/
21MAA
(Example of 1 : 1 system)
Remote display panel
PAR-SL97A-E
(Example of Simultaneous Twin)
• Operation/emergency signal can be received at a remote location (when channeled through the PAC-SF40RM no-voltage signal, when channeled through the PAC-SA88HA-E DC 12V signal).
• Remote display panel (to be purchased locally)
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote operation adapter
PAC-SF40RM
*Unable to use with wireless remote controller
PAR-30MAA
(Example of 1 : 1 system)
• Weekly Timer:
On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting)
• On/Off Timer:
On/Off can be set once each within 72 hr in intervals of 5-minute units.
• Auto-off Timer:
Operation will be switched off after a certain time elapse. Set time can be changed from
30 min. to 4 hr. at 10 min. intervals.
*Simple Timer and Auto-off Timer
cannot be used at the same time.
Standard functions of PAR-30MAA
Specifications
22
Specification: Outdoor Unit
Outdoor unit
External finish
Power supply
Compressor output
Airflow (cooling/heating)
Sound pressure level (dB)
(kW)
CMM (L /S)
Cooling mode
Heating mode
Sound level
Dimensions
Weight
Chargeless piping length
Max. piping length
Breaker size
Height
Width
Depth
(dB)
(mm)
(mm)
(mm)
(kg)
(m)
(m)
(A)
SUZ-KA25VA3
0.55
34 (568)/32 (534)
46
46
59
30
550
800
285
SUZ-KA35VA2
0.65
33 (551)
47
48
61
33
SUZ-KA50VA3
Munsell 3.0Y 7.8/1.1
Single-phase, 50Hz, 230V
0.85
49 (818)
53
55
68
850
840
330
53
7
20
10
SUZ-KA60VA3 SUZ-KA71VA3
0.9
51 (850)/49 (816)
50
880
840
330
55
55
69
1.2
50 (835)/48 (800)
53
30
20
*Above specifications are for outdoor units only.
Outdoor unit
External finish
Power supply
Compressor output
Airflow (cooling/heating)
Sound pressure level (dB)
(kW)
CMM (L /S)
Cooling mode
Silent mode
Sound level
Heating mode
Height
(dB)
(mm)
Dimensions Width
Depth
Weight
Chargeless piping length
Max. piping length
Protection device
Rated running current
(cooling/heating)
Breaker size
(mm)
(mm)
(kg)
(m)
(m)
(A)
(A)
1.6
60 (1,000)
47
44
48
66
943
950
330
67
30
50
9.05/9.64
25
PUHZ-RP71VHA5 PUHZ-RP100V/YKA2 PUHZ-RP125V/YKA2
Munsell 3.0Y 7.8/1.1
PUHZ-RP140V/YKA2
V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V
1.9
110 (1,830)
2.4
120 (2,000)
49
46
50
47
52 51
69 70
1,338
2.9
50
47
52
70
1,050
330
V: 118 Y: 119 V: 120 Y: 121
30
75
Discharge thermo, HP switch
V: 12.64/13.58 Y: 4.42/4.75
V: 16.36/16.90 Y: 5.73/5.91
V: 32 Y: 16
V: 17.17/19.23 Y: 6.01/6.73
V: 40 Y: 16
*Above specifications are for outdoor units only.
19 4-way Cassette
Compact Ceiling-concealed
SLZ
SEZ
SEZ-KD25/35/50/
60/71VAQ (L)
SLZ-KA25/50VAQ (L) optional for SLZ/SEZ-VAQ optional for SLZ/SEZ-VAQ standard for
SLZ-VAL standard for
SEZ-VAL
Compact, quiet concealed indoor units equipped with cutting-edge control technologies for enhanced comfort
Compact Designs
Models with capacity ranges for any room size. The dimensions of the SLZ are perfect for 2-metre-square installations, and the SEZ unit is a slim 200mm in height, making it ideal for tight installation spaces.
990mm 700mm
208mm
200mm
650mm 650mm
SLZ-KA25/50 SEZ-KD35/50
Impressively Quiet
S series units offer quiet operation at a hushed noise level of
23dB (SEZ-KD25/35), ensuring a calm and comfortable environment. They’re so quiet that you’ll find yourself checking to see if they’re on.
● Noise level
Subway car interior
Quiet passenger car interior
(40km/h) Library interior
Sound of rustling leaves
Human hearing limits
(Extremely quiet)
80dB 60dB 40dB
23dB
Quiet!
10dB
Energy-saving Operation
Boasting low electricity consumption, SLZ/SEZ series air conditioners are the key to fresh, cost-effective room comfort.
Air Cleaning Filter
This built-in filter removes dust and other particles, keeping the air clean all the time. Maintenance is as simple as vacuuming. The long-life filter in SLZ series air conditioners can be used for approximately 2,500 hours before requiring replacement.
Fresh-air Intake
A duct hole is provided in the main body, making it possible to intake fresh air from outside.
Fresh-air intake
Detail drawing of fresh-air intake
3- 2.8 hole
Burring hole
100
25
73.4
Cut-out hole
12
0°
Electrical box
Refrigerant pipe
Drain pipe
Ceiling surface
12
0°
Specifications: 4-way cassette / Compact ceiling-concealed (SLZ, SEZ)
Indoor unit SLZ-KA25VAQ(L) SLZ-KA50VAQ(L)
Outdoor unit
Function
Capacity (min.-max.)
Input
Rated EER/COP
Rated AEER/ACOP
AEER/ACOP (part-load %) ✽
Indoor unit
Power supply
(kW)
(kW)
SUZ-KA25VA3
Cooling Heating
2.3 (0.9-3.2) 3.1 (0.9-4.5) 4.2 (1.1-5.2) 4.5 (0.9-6.5) 2.5 (0.9-3.2) 3.0 (0.9-4.5)
0.6
3.83
3.65
4.32
0.82
3.78
3.66
SLZ-KA25VAQ(L)
SUZ-KA50VA3
Cooling Heating
1.27
3.31
3.23
1.37
3.28
3.22
SLZ-KA50VAQ(L)
SEZ-KD25VAQ(L)
SUZ-KA25VA3
Cooling
0.75
3.33
3.21
Heating
0.83
3.61
3.49
SEZ-KD25VAQ(L)
SEZ-KD35VAQ(L)
SUZ-KA35VA2
Cooling Heating
3.7 (1.0-3.9) 4.2 (0.9-5.0)
1.09
3.39
3.31
1.13
3.72
3.62
SEZ-KD35VAQ(L)
V: Single-phase, 50Hz, 230V
Airflow (Lo-Mid-Hi)
CMM
L/S
8-9-10
133-150-167
8-9-11
133-150-183
5.5-7-9
92-117-150
7-9-11
117-150-183
External static pressure Pa
Sound pressure level
Supply air spigot size
Height
Dimensions Width
Depth
Weight
(dB)
(mm)
(mm)
(mm)
(mm)
(kg)
28-31-37
—
30-34-39
—
Unit: 208, Panel: 20
Unit: 570, Panel: 650
Unit: 570, Panel: 650
Unit: 16.5, Panel: 3
23-26-30
660×150
200
790
700
18
23-28-33
21
SEZ-KD50VAQ(L)
SUZ-KA50VA3
Cooling Heating
SEZ-KD60VAQ(L)
SUZ-KA60VA3
Cooling Heating
SEZ-KD71VAQ(L)
SUZ-KA71VA3
Cooling Heating
5.1 (1.1-5.6) 6.4 (1.1-7.2) 5.6 (1.1-6.3) 7.4 (0.9-8.0) 6.5 (0.9-8.3) 8.1 (0.9-10.4)
1.64
1.81
1.77
2.05
2.06
2.18
3.11
3.05
3.72
3.54
3.48
SEZ-KD50VAQ(L)
3.16
3.11
3.61
3.55
SEZ-KD60VAQ(L)
3.16
3.10
3.72
3.66
SEZ-KD71VAQ(L)
860×150
200
990
700
10-12.5-15
167-208-250
5/15/35/50
30-34-37
23
12-15-18
200-250-300
30-34-38
1,060×150
200
1,190
700
12-16-20
200-267-333
30-35-40
27
✽ MEPS compliant at part load
Main Features
20
Main features of Mr. Slim Inverter Units
Indoor unit SLZ-VA SLZ-VAL SEZ-VA SEZ-VAL
Combination
Energy Saving
Outdoor unit
Felt Temperature Control
(i-see Sensor)
SUZ SUZ SUZ SUZ PUHZ
Opt
PLA
SUZ
Opt
Pure White
Attractive
Auto Vane
PUHZ
PEAD
SUZ
PEA
PUHZ
PKA
PUHZ
PCA-KA
PUHZ SUZ
Air Quality
Fresh-air Intake
High-efficiency Filter
Oil Mist Filter
Long-life filter
Filter Check Signal
Horizontal Vane (Auto Swing)
Air Distribution High Ceiling Mode
Opt Opt
Auto Fan Speed Mode
On/Off Operation Timer
Auto Change Over *1
Auto Restart
Convenience
Low-temperature Cooling
Low-noise Operation (Outdoor Unit)
Rotation, Back-up and 2nd Stage
Cut-in Function
PAR-21MAA Control *2
Centralised On/Off Control *2
Opt
Opt
Opt
Opt
Opt
Opt
Opt
System Control
Opt Opt Opt Opt Opt
Opt System Group Control *2
M-NET Connection *2
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt Opt
Opt
Opt
Opt
Opt
Reuse of Existing Wiring
Drain Pump Opt Opt
Installation
Pump Down Switch
Flare Connection
Self-Diagnosis Function
(Check Code Display)
Maintenance
Failure Recall Function
*1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible.
*2 Please refer “System Control” on page 21 for details.
*3 Not available with PEA-RP140/170/200WJA models.
Opt
Opt
Opt
*3
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt