BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all NEC and local codes.
• Use only UL or IEC approved wire for input/output connections.
Minimum size 18 AWG.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N’utilisez que des fils approuvés par UL ou IEC pour les entrées/sorties de connexion. Taille minimum 18 AWG.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-3 (A)/NMB-3(A)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• The LED driver must be supplied with 120-277 VAC, 50/60
Hz per product label and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker.
Tools and Components Required:
• ALM1 Series fixture
• Mounting hardware (not Included)
• #2 Phillips screwdriver
• Drill
Grounding Instructions
• The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article
600 and local codes.
imagination at work
Unit Installation
1 For safety, turn off main power prior to installation.
Remove LED plate
2 Before installation, loosen two screws on side of fixture, and open by holding lenses and sliding LED plate away from screws.
3 Remove red wire and blue wire which lead to the power supply from connectors, and remove LED plate from box by rotating LED plate 90° and sliding the plate towards the box until the hinges can be removed.
Fasten to ceiling with appropriate hardware
4 Remove appropriate knockout in fixture for power input.
5 Install box to intended surface using mounting holes on both ends of fixture with appropriate mounting hardware. If mounting into a joist, use 2 wood screws and 2 washers to attach to joist. If joist is not available, use 2 toggle bolts and 2 washers to attach to plasterboard.
AC line
LED driver
6 Connect the black (line) and white (neutral) wires of the
AC line to the similarly colored wires of the fixture’s LED driver using UL listed wire connectors. Connect the green
(ground) to the lug inside the fixture.
7 Reinsert the LED plate into the box so that it is hanging open by the hinges.
8 Reattach red wire and blue wire into connectors, and give wires a firm tug to confirm proper connection.
10 Restore main power.
9 Tuck wires inside and close LED plate. Reinsert screws into LED plate on side of fixture making sure to pull the
LED plate firmly against the screw side of box.
GE Lighting • 1-888-MY-GE-LED
(1-888-69-43-533)
• www.gelighting.com
The GE brand, logo, and Albeo are trademarks of the General Electric Company.
© 2014 GE Lighting , LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
ALB009-031014
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project