Daintree GE Albeo AHH2 is a high efficiency LED luminaire designed to provide superior lighting in demanding industrial applications. The luminaire offers a wide range of mounting options, including pendant, chain or cable, rod, and surface mount, making it suitable for various ceiling heights and configurations.
The Albeo AHH2 features a rugged design with a corrosion-resistant finish, making it ideal for use in harsh environments such as warehouses, factories, and manufacturing facilities. It delivers exceptional energy efficiency, reducing operating costs while providing optimal illumination.
advertisement
Albeo
®
AHH2
LED Luminaire
Heavy Industrial High Bay Lighting
ALB 082
Installation Guide
ALB082
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Save these instructions for future use.
WARNING/AVERTISSEMENT/ADVERTENCIA
Risk of electrical shock. Turn power off before inspection, installation or removal. Properly ground electrical enclosure.
Risk of fire. Follow all NEC and local codes for the required wiring systems for the specific Hazardous Locations involved .
Ris q ues de décharges électriques. Coupez l’alimentation avant d’inspecter, installer ou déplacer le luminaire. Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
Risque d’incendie. Respectez tous les codes NEC et codes locaux.
This device complies with Part 15 of the FCC Rules , not part of UL Certification . Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN
ICES-005 (A) / NMB-005 (A)
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules , not part of UL
Certification . These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
The LED luminaire must be supplied with 120-277 VAC or
347/480 VAC, 50/60 Hz per electrical ratings on product label and connected to an individual properly grounded branch circuit.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance with National Electric Code (NEC) Article 600 and local codes.
Albeo
®
AHH2
LED Luminaire Installation Guide
Section 1: Unit Installation
Provide at least 12” of clearance from the top of the fixture to any ceiling or surface above.
A
Carefully unpack unit and properly inspect for defects before installing. Wear work gloves to prevent dirt and oil from being transferred to the luminaire.
B
Choose a mounting method: chain or cable, rod mount, or pendant mount.
Fixture Weight
ABR1-Series Max. Weight (lbs.)
C
Gray
-10V (+)
0-10V (–)
NOTE : For applications requiring the “R” corrosion resistant finish, use mounting hardware appropriate for the environment
Section
2
: Pendant Mounting
A B C
Attach to structural member pendant mount cover
Attach pendant mou nt cover t o ¾” NPT conduit with at least 3 full threads of engagement. Determine rotation of luminaire and lock orientation in place withprovided set screw.
Single Fixture
Lift luminaire up and hang on pendant mount cover using hinge piece.
Attach to structural member
Feed the AC power lead wire through the conduit and into the junction box.
Dual Fixture
D
Fasten with nuts
Attach to structural member
Swing luminaire closed and secure with the slide clip. Lock slide clip in place with screw.
E and white (neutral) wires of the AC line to the similarly colored wires of the lead wire using UL listed wire connectors.
Close junction box.
luminaire's
Line
Neutral
Ground
0-10V(+)
0-10V(-)
Black
White
Green
Purple (+)
Gray (-)
To AC Main
To 0-10V
Dimmer
For dimming options, connect purple and gray leads to dimming control that is certified and suitable for the hazardous locations involved, rated
0-10V min. A 10V signal corresponds to 100% lumen output. A 0V signal corresponds to ~10% lumen output.
Cap purple and gray leads separately when not used.
2
AC power cord
Albeo
®
AHH2
LED Luminaire Installation Guide
F
Captive screws
Captive screws
See
Note
AC power cord
Tighten screw
Tighten screw
See
Note
Single Fixture
AC power cord
Dual Fixture
Tighten screw screw
Secure pendant mount cover to luminaire by fully tightening the captive screws on the sides of the pendant mount box to the fixture.
NOTE: Safety chains (installer provided) can be used in mounting slots at end of fixture.
Section
3
: Troubleshooting
Symptom Solution
Line
Neutral
Ground
0-10V(+)
0-10V(-)
Black
White
Green
Purple (+)
Gray (-)
Luminaire will not turn on.
• Check that the color of the supply side wires match the color of the wires they are connected to.
• Check that all wire connectors are properly connected.
• Verify that your input voltage is within specs.
• If you are using any additional controls (i.e. dimming wires, motion sensors), please also verify that those are
Line Black
White
Black working properly and that the unit is setup to interface with the controllers.
0-10V(+)
0-10V(-)
Purple (+)
Gray (-)
To 0-10V
Dimmer
Section
4
: Maintenance
Line
Neutral
Ground
0-10V(+)
Black
To AC Main
White
• Product should not be disassembled during installation process and/or while installed.
• Lens should be cleaned periodically for maximum lumen output.
• Inspect and clear any build-up on cooling fins periodically for maximum performance.
To AC Main
To 0-10V
Dimmer
Questions:
Web: products.gecurrent.com
Phone: 1-866-855-8629
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to GE current.
Ces instructions ne prétendent pas couvrir tous les détails ou variantes de l’équipement ni couvrir toutes les conditions possibles à satisfaire en rapport avec l’installation, l’opération ou l’entretien. Si des informations supplémentaires sont souhaitées sur des aspects qui ne sont pas suffisamment couverts pour satisfaire les besoins du client, ou si des problèmes particuliers se présentent, veuillez addresser ces questions à GE current.
Estas instrucciones no pretenden cubrir todos los detalles o variaciones en el equipo ni para prever cualquier contingencia que debe cumplir en relación con la instalación, la operación o el mantenimiento. De ser deseada más información o se surgieran problemas particulares que no están cubiertos suficientemente para los propósitos del comprador, favor de remitirse a GE current.
3”
12”
www.gecurrent.com
© 2020 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information provided is subject to change without notice.
All values are design or typical values when measured under laboratory conditions.
ALB 082 (Rev. 0 7 / 13 /2020 )
1/2” bolts
Tighten screw
Line
Neutral
Ground
0-10V(+)
0-10V(-)
Black
White
Green
Purple (+)
Gray (-)
To AC Main
To 0-10V
Dimmer
Safety chain