Dimplex NBDF2608 Service manual


Add to my manuals
18 Pages

advertisement

Dimplex NBDF2608 Service manual | Manualzz

For service questions, please call Dimplex at 1-888-346-7539.

For sales inquiries, please call Sylvane at 1-800-934-9194 or visit sylvane.com.

Service Manual

26” Self Trimming Fireplace

Model Number:

DF2608

DF2622

NBDF2608

UL Part Number

6904400359

IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to service this

fireplace. For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage.

REV PCN DATE

00 11527 Jul 20, 09

Dimplex North America Limited

1367 Industrial Road Cambridge ON Canada N1R 7G8

1-888-346-7539 www.dimplex.com

In keeping with our policy of continuous product development, we reserve the right to make changes without notice.

© 2011 Dimplex North America Limited

01

02

03

11658 Oct 13, 09

11879 Feb 12, 10

Jan 3.12

7400200000R03

Table of Contents

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Exploded Parts Diagram - DF2608/NBDF2608 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Wiring Diagram - DF2608 / NBDF2608 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Exploded Parts Diagram - DF2622 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Wiring Diagram - DF2622 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Front Glass Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Partially Reflective Glass Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3-Position Switch Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Heater Switch Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Light Dimmer Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Flame Speed Control Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Flicker Motor/Flicker Rod Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Thermostat Control Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Remote Control Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Log Driver Controller Replacement (DF2608 only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Lower Light Harness Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Heater Assembly Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Power Cord Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Always use a qualified technician or service agency to repair this fireplace.

!

NOTE: Procedures and techniques that are considered important enough to emphasize.

CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the

equipment.

WARNINg: Procedures and techniques which, if not carefully followed, will expose the user to the

risk of fire, serious injury, or death.

2

Operation

This section will explain the function of each convenient control (Figure 2).

To access the controls, flip open the control panel cover towards the bottom of the fireplace (Figure 1).

Figure 1

when first used. This odor is a normal condition caused by initial heating of internal heater parts and will not occur again.

Resetting The Temperature Cutoff Switch

This unit is equipped with a thermostat which controls the temperature of the room. It does this by turning the heater on and off. The heater is protected with a safety device to prevent overheating. Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the 3-Position Switch to Off (“ o ”)and waiting five (5) minutes before switching the unit back on.

CAUTION: If you need to continuously reset the heater, unplug the unit and call Technical Support at

1-888-346-7539. Please have your model and serial number ready when calling.

Figure 2

A B C E D

Remote Control

The fireplace is supplied with an integrated on/off remote control.

! NOTE: Ensure that the 3-Position

Switch on the fireplace is set to the remote control setting (“II” position).

To operate, push the ON button to turn the fireplace on, push the OFF button to turn the fireplace off.

Figure 3

OFF

Button

A. 3-Position Switch

The switch has two (2) On positions marked with “ I ” and

II . The “ I ” position is for manual operation. In this position the built-in remote control is bypassed. The “ II ” position is for operating the unit with the provided remote control. When in “ II ” position the unit is operated with the ON and OFF buttons of the remote control. When the switch is in the center “ o position the unit is off.

B. Flame Speed Control

Turn the Flame Speed Control knob to adjust the flame speed to the desired level.

C. Light Dimmer Control

Turn the Light Dimmer Control knob to increase or decrease the brightness of the interior of the fireplace.

D. Heater Switch

The Heater Switch supplies power to the heating unit when the 3-Position Switch (A) is on ( “ I ” or “ II ” positions) .

E. Thermostat Control

To adjust the temperature to your individual requirements, turn the thermostat control clockwise all the way to turn on the heater. When the room reaches the desired temperature, turn the thermostat knob counter clockwise until you hear a click. Leave in this position to maintain the room temperature at its setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on. To turn the heater off, rotate the knob fully counter clockwise.

! NOTE: The heater may emit a slight, harmless odor

Battery Replacement (Figure 3)

To replace the battery:

• Slide battery cover open on the hand held transmitter.

• Correctly install one (1) 12 Volt

(A23) battery in the battery holder.

• Close the battery cover.

ON

Button

Battery

Cover

Remote Initialization/Reprogram

Follow these steps for remote control initialization and if required, reinitialization:

1. Disconnect power to fireplace.

2. Set the 3-Position Switch to the Remote position (Figure

2A).

3. Wait a minimum of five (5) seconds and then reacquire power to fireplace.

4. Within 10 seconds of reacquiring power, press the ON button located on the remote control.

! NOTE: You will have only 10 seconds to perform this last step. Failure to do so will result in these steps needing to be followed again.

3

Maintenance

WARNINg: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons.

Figure 5

Light Block

Light Block screws (4)

Light Bulb Replacement

Allow at least five (5) minutes for the light bulbs to cool before touching them to avoid accidental burning of the skin.

The light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log ember bed exterior reduces. There are three (3) bulbs under the Log Set Assembly, which generate the flames and embers, and two (2) bulbs above that illuminate the log exterior.

Lower Light Bulb Requirements: Quantity of three (3) clear chandelier or candelabra bulbs with an E-12 (small) socket base, 60 Watt rating. Example: GE 60BC or Philips 60CTC.

Do not exceed 60 Watts per bulb.

Helpful Hints: It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce the number of times you need to open the unit to replace light bulbs. Care must be taken when removing the Log set assembly as it contains LED’s and wires (DF2608 only).

1.

2.

3.

4.

5.

6.

Slide fireplace out of mantel.

Lay unit on it’s back for safe removal of front glass.

Remove three (3) Phillips screws from the right side of trim.

Remove trim.

Slide glass to right side of fireplace to remove (Figure 3).

Pull the front edge of the plastic ember bed or plastic grate up and forward until the rear tab releases from the ledge located at the bottom of the partially reflective glass (Figure 4).

! IMPORTANT: Only handle the log set assembly by the ember bed or plastic grate.

! NOTE: Log set assembly fits tightly into firebox, some force may be necessary to remove.

7.

8.

9.

10.

Set log set assembly in front of fireplace.

Remove flicker rod by pulling rod to the right, towards the flicker motor. Bend the flicker rod enough to clear the bracket on the left, lift out and pull flicker rod off of flicker motor shaft (Figure 5).

Remove four (4) Phillips screws (two (2) per side) which attach light filter bracket for easier access to light bulbs

(Figure 5).

Unscrew bulbs counter clockwise to remove.

Figure 3

Log Set

Assembly

Front

Glass

Trim

Flicker Rod

Light Filter

Bracket screws (2)

Lower Light

Bulbs (3)

Figure 4

Back

Ledge

Rear

Tab

Log

Ember Bed

Side Section

11.

12.

13.

Insert new bulbs and screw in clockwise.

Replace light filter bracket and flicker rod.

Install the log set assembly by placing the front, bottom edge of the ember bed in the track behind the control panel. Once in place, push down on the back edge of the ember bed until the rear tab snaps into place under the mirror (Figure 4).

! NOTE: Ensure the log set Assembly is installed tightly under the bottom edge of the mirror to prevent light leakage.

14. Lay unit on it’s back and slide Front Glass back into position and attach trim.

Upper Light Bulb Requirements: Quantity of two (2) clear chandelier or candelabra bulbs with an E-12 (small) socket base, 15 Watt rating.

Do not exceed 25 Watts per bulb.

To access the upper light bulb area:

1.

2.

3.

4.

5.

6.

Slide fireplace out of mantel.

Lay unit on it’s back for safe removal of front glass.

Remove three (3) Phillips screws from right side of trim.

Remove trim.

Slide glass to the right side of the fireplace to remove

(Figure 3).

Upper bulbs are located in the upper left and upper right corners of fireplace, behind the light block bracket

(Figure 5).

7.

8.

9.

10.

11.

Remove the four (4) Phillips screws that attach the light block to the firebox (Figure 5).

Unscrew bulbs counter clockwise.

Insert new bulbs and screw in clockwise.

Re-attach light block bracket.

Lay unit on it’s back, slide front glass back into position and attach Trim.

Front

Edge

glass Cleaning

The glass is cleaned in the factory during the assembly operation. During shipment, installation, handling, etc., the clear door may collect dust particles, these can be removed by dusting lightly with a clean dry cloth.

To remove fingerprints or other marks, the clear door can be cleaned with a damp cloth.

Fireplace Surface Cleaning

Use a cloth dampened with warm water only to clean painted surfaces of the electric fireplace. Do not use abrasive cleaners.

4

Exploded Parts Diagram - DF2608/NBDF2608

4

10

12

16

13

7

18

1

14

1

15

9

19

8

11

5

6

1.

2.

3.

4.

Replacement Parts List

Part Number

Replacement Part:

6904400359

Log Set . . . . . . . . . . . . . . . . . . . . . . . . 0439560100RP

Log Driver Controller . . . . . . . . . . . . . . 3000390100RP

Flicker Motor . . . . . . . . . . . . . . . . . . . 3000240200KIT

Heater Assembly (with cutout) . . . . . . 2000330100RP

5.

6.

7.

8.

9.

Thermostat . . . . . . . . . . . . . . . . . . . . . 2300150100RP*

Heater Switch . . . . . . . . . . . . . . . . . . . 2800210500RP

3-Position Switch . . . . . . . . . . . . . . . . 2800210100RP

Flame Speed Control

Light Dimmer Control

. . . . . . . . . . . . . 3000240500RP

. . . . . . . . . . . . . 3000250100RP

10. Power Cord . . . . . . . . . . . . . . . . . . . . 4100040200RP

11.

12.

Single Light Holder . . . . . . . . . . . . . . . 2500150300RP

Double Light Harness . . . . . . . . . . . . 2500400300RP

13. Partially Reflective Glass . . . . . . . . . . 5901210200RP

Partially Reflective Glass (NBDF2608) 5901450100RP

14.

15.

Front Glass . . . . . . . . . . . . . . . . . . . . 5901220100RP

Control Knob (3 on unit) . . . . . . . . . . . 8800000200RP

16.

17.

18.

19.

Remote Control . . . . . . . . . . . . . . . . . 3000370500RP

Remote Control Receiver

Terminal Block . . . . . . . . . . . . . . . . . . 4000070100RP

Flicker Rod

. . . . . . . . . . 3000380200RP

. . . . . . . . . . . . . . . . . . . . . 5901250100RP

5

3

2

17

Wiring Diagram - DF2608 / NBDF2608

Remote Control

Receiver

Heater

Switch

3-Position

Switch

Log Set

Driver

Thermostat

Heater

Assembly

Power

Cord

Light Dimmer

Control

Flame Speed

Control

6

Exploded Parts Diagram - DF2622

9

3

11

22

6

17

13

1

20

14

12

21

8

18

7

15

10

Replacement Parts List

4.

5.

6.

7.

Part Number 6904400659

Replacement Part:

1. Log Set . . . . . . . . . . . . . . . . . . . . . . . 0439560200RP

2.

3.

Flicker Motor . . . . . . . . . . . . . . . . . . 3000240200KIT

Heater Assembly (with cutout) . . . . . 2000330100RP

Thermostat . . . . . . . . . . . . . . . . . . . . 2300150100RP*

Heater Switch . . . . . . . . . . . . . . . . . . 2800210100RP

3-Position Switch . . . . . . . . . . . . . . . 2800210500RP

Flame Speed Control . . . . . . . . . . . . 3000240500RP

8.

9.

10.

11.

Light Dimmer Control . . . . . . . . . . . . 3000250100RP

Power Cord . . . . . . . . . . . . . . . . . . . 4100040200RP

Single Light Holder . . . . . . . . . . . . . . 2500150300RP

Double Light Harness . . . . . . . . . . . 2500400300RP

12. Partially Reflective Glass . . . . . . . . . 5901450100RP

19

5

4

13.

14.

Front Glass . . . . . . . . . . . . . . . . . . . 5901220100RP

Control Knob (3 on unit) . . . . . . . . . . 8800000200RP

15.

16.

17.

Remote Control

Remote Control Receiver . . . . . . . . . 3000380200RP

Terminal Block

. . . . . . . . . . . . . . . . 3000370500RP

. . . . . . . . . . . . . . . . . 4000070100RP

18. Flicker Rod . . . . . . . . . . . . . . . . . . . . 5901250100RP

Stainless Steel Replacement Parts for DF2622SS

19. Stainless Steel Control Cover . . . . . . 1018760180RP

20. Stainless Steel Top Trim . . . . . . . . . . 1018830180RP

21.

22.

Stainless Steel Right Side Trim

Stainless Steel Left Side Trim

. . . . . 1018840180RP

. . . . . . 1018830280RP

7

2

16

Wiring Diagram - DF2622

3-Position

Switch

Remote Control

Receiver

Light Dimmer

Control

Power Cord

Heater

Switch

Heater

Assembly

Thermostat

8

Front glass Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

3.

4.

5.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1.

2.

Slide firebox out of mantel.

Lay unit on it’s back for safe removal of Front Glass.

6.

Remove three (3) Phillips screws from right side of Trim.

Remove Trim.

Slide glass to the right side of the firebox to remove

(Figure 6).

Reassemble using replacement Front Glass in reverse order as described above.

CAUTION: Even though the glass is safety glass it may break if bumped, struck or dropped. Care must be taken when handling the glass.

Figure 6

Reflective Glass.

! IMPORTANT: Only handle the Log Set Assembly by the Ember Bed or plastic grate.

! NOTE: Log Set Assembly fits tightly into firebox, some force may be necessary to remove.

7.

8.

Loosen but do not remove the two (2) Philips screws that clamp the Partially Reflective Glass in place, and swivel down so that the clamp clears the edge of the

Partially Reflective Glass (Figure 7).

Push the Partially Reflective Glass out from behind to clear the frame and remove.

9. Insert replacement Partially Reflective Glass top end first and lay the bottom end gently in the bottom track of the frame.

10. Tighten clamps back into place and reassemble firebox in reverse order as described above.

Figure 7

Partially Reflective

Glass

Clamp

Trim

Log Set

Assembly

Front Glass

Partially Reflective Glass Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1.

2.

Slide firebox out of mantel.

Lay unit on it’s back for safe removal of Front Glass.

3.

4.

5.

Remove three (3) Phillips screws from the right side of

Trim.

Remove Trim.

Slide glass to right side of fireplace to remove (Figure

6).

CAUTION: Even though the glass is safety glass it may break if bumped, struck of dropped. Care must be taken when handling the glass.

6. Pull the front edge of the plastic Ember Bed or plastic grate up and forward until the rear tab releases from the ledge located at the bottom of the Partially

3-Position Switch Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1. Remove the firebox from the mantel.

2.

3.

4.

Lay unit on its back.

Remove the 12 Philips screws that fasten the bottom cover to the rest of the firebox. There are: two (2) screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (see Figure 8). The bottom panel is now free to be removed.

Locate the 3-Position Switch mounted on the control panel on the left side (Figure 9) and disconnect the three (3) wiring clips noting their original locations.

CAUTION: Internal wire colors may not be the same within the unit being serviced as those shown. To avoid damage to the unit, damage to property or personal injury, ensure wires are reconnected to match their original locations.

5. Depress the two (2) retainer clips on the top and

9

6. bottom of the switch and push the switch out the front panel.

Properly orient the new switch and reconnect all of the wiring clips and connections as before.

7. Push the switch through the front control panel until the Retainer Clips snap the switch into place, then reassemble the firebox in reverse order as above.

! NOTE: When placing bottom panel back onto unit, position the metal lip from under the control panel between the rubber spacers (attached to the bottom panel) and the sheet metal of the bottom panel.

Heater Switch Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1.

2.

3.

Remove the firebox from the mantel.

Lay unit on its back.

Remove the 12 Philips screws that fasten the bottom cover to the rest of the firebox. There are: two (2)

Figure 8

Screws To Remove

Figure 9

3-Position Switch

Retainer Clips

(One top, one bottom)

4. screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (Figure 8). The bottom panel is now free to be removed.

Locate the Heater Switch mounted on the control panel on the right side (Figure 10, page 11) and disconnect the two (2) wiring clips noting their original locations.

CAUTION: Internal wire colors may not be the same within the unit being serviced as those shown. To avoid damage to the unit, damage to property or personal injury, ensure wires are reconnected to match their original locations.

5. Depress the two (2) retainer clips on the top and bottom of the switch and push the switch out the front of the firebox.

6. Properly orient the new switch and reconnect all of the wiring clips and connections as before.

7. Push the switch through the front control panel until the Retainer Clips snap the switch into place, then reassemble the firebox in reverse order as above.

! NOTE: When placing bottom panel back onto unit, position the metal lip from under the control panel between the rubber spacers (attached to the bottom panel) and the sheet metal of the bottom panel.

Light Dimmer Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1.

2.

Remove the firebox from the mantel.

Lay unit on its back.

3. Remove the 12 Philips screws that fasten the bottom

Figure 10

Heater Switch

Retainer Clips

(One top, one bottom)

Wire 1: Dark orange piggy-back wire from bottom terminal of switch to: top, left terminal of Dimmer Control and; to one of 3 wire connectors.

Wire 2: Black, smooth edged wire from power cord to middle terminal of switch.

Wire 3: Grey wire from top terminal of switch to opposite side of firebox.

Wire 3 Wire 2 Wire 1

Wire 1

Wire 2

Wire 1: Dark orange wire from bottom terminal of switch to top, right terminal of

Log Driver (DF2608).

Wire 2: Yellow wire from top terminal of switch to other side of firebox.

10

4.

5. cover to the rest of the firebox. There are: two (2) screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (Figure 8). The bottom panel is now free to be removed.

Locate the Light Dimmer Control Board and

Potentiometer mounted on the left side (Figure 11).

Pull off the Light Dimmer Control knob and unscrew the retaining nut (Figure 11). The Potentiometer can now be removed from the panel by pushing the potentiometer through the front panel and removed from inside the firebox.

6. The Light Dimmer Control board is fastened to the underside of the Ember Bed support by four (4) mounting studs, one in each corner (Figure 11).

Squeeze each mounting stud’s clasp to release the circuit board from the firebox.

! NOTE: If mounting studs are damaged, replacement mounting studs will need to be inserted from underneath

Log Set Assembly. Follow steps 1 - 6 of Partially Reflective

Glass Replacement procedure on page 9 to do this. It is recommended to attempt to release the control board without cutting mounting studs.

7.

8.

Properly orient the replacement Light Dimmer Control board and push it onto the four (4) mounting studs

(running the connecting Potentiometer wires under the board) until the clasps of the mounting studs snap the control board into place.

Properly orient the Potentiometer attached to the replacement control board, push it through the front control panel and anchor it in place using the retaining

Figure 11

Retaining

Nut

Potentiometer

Light Dimmer

Control Board

Mounting Studs (4)

Wire 1 Wire 2

Wire 1: White wire from bottom, left terminal of board to cable sheath leading to upper firebox area.

Wire 2: Dark orange piggy-back wire from top, left terminal of board to: top, right terminal of Flame Speed Control board and; bottom terminal of 3-Position Switch.

9. nut removed in step 5.

Disconnect one of the two (2) wire leads from the original control board (which are still connected to parts within the firebox) and immediately connect it to the new control board’s terminal, matching its position.

Continue with the remaining wire using the same procedure.

CAUTION: Internal wiring and colors may not be the same within the unit being serviced as those shown. To avoid damage to the unit, damage to property or personal injury, ensure wires are reconnected to match their original locations.

10. Follow steps 1 through 3 in reverse order to reassemble the firebox.

! NOTE: When placing bottom panel back onto unit, position the metal lip from under the control panel between the rubber spacers (attached to the bottom panel) and the sheet metal of the bottom panel.

Flame Speed Control Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1.

2.

3.

4.

Remove the firebox from the mantel.

Lay unit on its back.

Remove the 12 Philips screws that fasten the bottom cover to the rest of the firebox. There are: two (2) screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (Figure 8). The bottom panel is now free to be removed.

Locate the Flame Speed Control and Potentiometer mounted on the left hand side (Figure 12).

5.

6. The Flame Speed Control board is fastened to the underside of the Ember Bed support by four (4) mounting studs, one in each corner (Figure 12).

Squeeze each mounting stud’s clasp to release the circuit board from the firebox.

! NOTE: If mounting studs are damaged, replacement mounting studs will need to be inserted from underneath

Log Set Assembly. Follow steps 1 - 6 of Partially

Reflective Glass Replacement procedure to do this. It is recommended to attempt to release the control board without cutting mounting studs.

7.

Pull off the Flame Speed Control knob and unscrew the retaining nut (Figure 12). The Potentiometer can now be removed from the panel by pushing the

Potentiometer through the front panel and remove from inside the firebox.

Properly orient the replacement Flame Speed Control board and push it onto the four (4) mounting studs

(running the connecting Potentiometer wires under the

11

Figure 12

Potentiometer

Flame Speed

Control Board

Retaining

Nut

Wire 1

Mounting Studs (4)

Wire 3

Wire 2

Cable connector for Flicker Motor

Wire 1: Dark orange piggy-back wire from top, right terminal of Flame Speed Control board to: top, right terminal of Light Dimmer board and; other side of firebox.

Wire 2: Blue wire from bottom, right terminal of Flame

Speed Control board to one of 3 wire connectors.

Wire 3: Black wire from bottom, right terminal of Flame

Speed Control board to power cord.

board where possible) until the clasps of the mounting studs snap the control board into place.

8.

9.

Properly orient the Potentiometer attached to the replacement control board, push it through the front control panel and anchor it in place using the retaining nut removed in step 5.

Disconnect one of the wire leads from the original control board (which are still connected to parts within the firebox) and immediately connect it to the new control board’s terminal, matching its position.

Continue with the remaining wires (there are four (4) wires which are piggy-backed together in pairs, and the cable connector which leads to the Flicker Motor) using the same procedure.

CAUTION: Internal wiring and colors may not be the same within the unit being serviced as those shown. To avoid damage to the unit, damage to property or personal injury, ensure wires are reconnected to match their original locations.

10. Follow steps 1 through 3 in reverse order to reassemble the firebox.

! NOTE: When placing bottom panel back onto unit, position the metal lip from under the control panel between the rubber spacers (attached to the bottom panel) and the sheet metal of the bottom panel.

Flicker Motor/Flicker Rod Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1.

2.

Remove the firebox from the mantel.

Lay unit on its back.

3.

4.

Remove the 12 Philips screws that fasten the bottom cover to the rest of the firebox. There are: two (2) screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (Figure 8). The bottom panel is now free to be removed.

Locate Flicker Rod and Flicker Motor in the base assembly (Figure 13).

5. Gently pull the Flicker Rod to the right as far as possible into the rubber bushing (Figure 13).

! NOTE: When removing the Flicker Rod, damage may occur if bent excessively. If the Flicker Rod is damaged, replace to insure proper operation.

6.

7.

8.

Cautiously bend the Flicker Rod enough so that the remaining end of the Flicker Rod clears the plastic bushing on the left (Figure 14).

Remove the Flicker Rod by pulling it free from the rubber bushing on the motor shaft (Figure 14).

Before removing the Flicker Motor, cut the Flicker Motor

Figure 13

Figure 14

5 Color

Cable

Flicker

Rod

Flicker

Motor

Mounting

Screw

Rubber

Bushing

Flicker

Motor

Mounting

Screw

12

9. wires (five (5) in total) as close to the Flicker Motor as possible.

Remove the rubber bushing from the motor shaft by applying needle nose pliers to the motor shaft and twist the rubber bushing off of the motor shaft.

10. Remove the two (2) motor mounting screws and remove Flicker Motor from the mounting bracket

(Figure 14).

11.

12.

Discard old Flicker Motor.

Pick up new Flicker Motor and cut wire leads to 3 ½ inch long with wire cutters.

13. Using one of the supplied wire connectors from the

Replacement Part Kit, place one (1) yellow wire from the new Flicker Motor and the yellow wire cut in step 8 into each terminal.

14. Secure the wire connector by crimping the 3M symbol with pliers.

15. Pull on end of wires to ensure a strong connection.

16. Repeat the process for the four (4) remaining wires.

Ensure that all wires are paired by color in each

connector.

! NOTE: In the event that multiple Flicker Motors were already replaced within unit, or if required wiring has been cut too short, it may be necessary to replace Flicker Motor and the attached cable as a whole.

To do so: i) Follow steps 1 through 7 and step 9. ii) Unplug the cable connector from the Flame Speed

Control board on the left side of the firebox (Figure 12, page 12).

iii) Cut all cable ties that bind the Flicker Motor Cable and other wires together (wires and cable run behind the lower bulbs).

iv) Follow steps 10 and 11 to remove defective Flicker

Motor.

v) Follow steps 17 through 19 to install new Flicker

Motor.

vi) Run Flicker Motor Cable along channel behind lower bulbs and bind together with other wires using cable ties.

vii) Plug cable connector into Flame Speed Control board (Figure 12).

viii) Reassemble firebox and replace in mantel.

17. Properly orient and secure the replacement Flicker

Motor to the bracket with screws removed in step 10.

18. Replace rubber bushing on motor shaft.

19. Replace Flicker Rod.

20. Reassemble firebox and replace in mantel.

! NOTE: When placing bottom panel back onto unit, position the metal lip from under the control panel between the rubber spacers (attached to the bottom panel) and the sheet metal of the bottom panel.

Thermostat Control Replacement

CAUTION: If unit was operating prior to servicing allow

13 at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1. Remove the firebox from the mantel.

2.

3.

4.

Lay unit on its back.

Remove the 12 Philips screws that fasten the bottom cover to the rest of the firebox. There are: two (2) screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (Figure 8). The bottom panel is now free to be removed.

Locate the Thermostat Control mounted on the control panel on the right hand side (Figure 15) and disconnect the two (2) wiring clips noting their original locations.

CAUTION: Internal wiring and colors may not be the same within the unit being serviced as those shown. To avoid damage to the unit, damage to property or personal injury, ensure wires are reconnected to match their original locations.

5.

6.

Pull off the thermostat control knob to expose the two

(2) Philips mounting screws (Figure 15).

Remove the mounting screws and remove the thermostat controller from inside the control panel.

7. Properly orient the new Thermostat Control and reconnect the wiring connections.

8. Reassemble in the reverse order as above.

! NOTE: When placing bottom panel back onto unit, position the metal lip from under the control panel between the rubber spacers (attached to the bottom panel) and the sheet metal of the bottom panel.

Figure 15

Thermostat

Wire 1

Wire 2

Screw

Wire 1: Blue wire from right terminal of thermostat to top, right terminal of Remote Control Receiver.

Wire 2: Blue wire from left terminal of thermostat to opposite side of firebox and up to Heater Assembly.

Remote Control Replacement

Remote Control require no replacement procedure however, a reinitialization procedure may need to be followed. Refer to Page 1 for the Remote Initialization/

Reprogram procedure.

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1. Remove the firebox from the mantel.

2.

3.

4.

5.

Lay unit on its back.

Remove the 12 Philips screws that fasten the bottom cover to the rest of the firebox. There are: two (2) screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (Figure 8). The bottom panel is now free to be removed.

Locate the Remote Control Receiver mounted on the right hand side (Figure 16).

The Remote Control Receiver is fastened to the underside of the Ember Bed support by four (4) mounting studs, one in each corner (Figure 15).

Figure 16

Mounting

Studs (4)

Remote

Control

Receiver

Blue piggy-back:

From top, right terminal of Remote

Control Receiver to 1) right terminal of thermostat and 1) to left terminal of Log Driver board.

Orange piggy-back:

From top, left terminal of Remote

Control Receiver to 1) right terminal of Log Driver board and 1) to opposite side of firebox and to top terminal of

Flame Speed Control board.

grey:

From left side terminal of Remote Control

Receiver to opposite side of firebox, leading to Heater

Assembly.

Squeeze each mounting stud’s clasp to release the circuit board from the firebox.

! NOTE: If mounting studs are damaged, replacement mounting studs will need to be inserted from underneath the Log Set Assembly. Follow steps 1 - 6 of Partially

Reflective Glass Replacement procedure on page 9 to do this. It is recommended to attempt to release the control board without cutting mounting studs.

6. Properly orient the replacement Remote Control

Receiver board and push it onto the four (4) mounting studs until the clasps of the mounting studs snap the control board into place.

7. Disconnect one of the wire leads from the original control board (which are still connected to parts within the firebox) and immediately connect it to the new control board’s terminal, matching its position.

Continue with the remaining wires (there are four (4) wires which are piggy-backed together in pairs, and a single grey wire) using the same procedure.

CAUTION: Internal wiring and colors may not be the same within the unit being serviced as those shown. To avoid damage to the unit, damage to property or personal injury, ensure wires are reconnected to match their original locations.

8. Follow steps 1 through 3 in reverse order to reassemble the firebox.

! NOTE: When placing bottom panel back onto unit, position the metal lip from under the control panel between the rubber spacers (attached to the bottom panel) and the sheet metal of the bottom panel.

Log Driver Controller Replacement

(DF2608 only)

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1.

2.

Remove the firebox from the mantel.

Lay unit on its back.

3. Remove the 12 Philips screws that fasten the bottom cover to the rest of the firebox. There are: two (2) screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (Figure 8). The bottom panel is now free to be removed.

4. The Log Driver Control Board is fastened to the underside of the Ember Bed support by four (4) mounting studs, one in each corner (Figure 17).

Squeeze each mounting stud’s clasp to release the circuit board from the firebox.

! NOTE: If mounting studs are damaged, replacement mounting studs will need to be inserted from underneath the Log Set Assembly. Follow steps 1 - 6 of Partially

14

Reflective Glass Replacement procedure on page 9 to do this. It is recommended to attempt to release the control board without cutting mounting studs.

5. Properly orient the replacement Log Driver board and push it onto the four (4) mounting studs until the clasps of the mounting studs snap the control board into place.

6. Disconnect one of the wire leads from the original control board (which are still connected to parts within the firebox) and immediately connect it to the new control board’s terminal, matching its position.

Continue with the remaining wires (there are four (4) wires which are piggy-backed together in pairs, and a single grey wire) using the same procedure.

CAUTION: Internal wiring and colors may not be the same within the unit being serviced as those shown. To avoid damage to the unit, damage to property or personal injury, ensure wires are reconnected to match their original locations.

7. Follow steps 1 through 3 in reverse order to reassemble the firebox.

! NOTE: When placing bottom panel back onto unit, position the metal lip from under the control panel between the rubber spacers (attached to the bottom panel) and the sheet metal of the bottom panel.

Lower Light Harness Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

Figure 17

Log Driver

Control

Board

Mounting

Studs (4)

Multicolored LED

Wire Harness

Blue piggy-back:

From left terminal of Log Driver board to 1) right terminal of Remote Receiver board and 1) to other side of firebox and connecting to wire nut.

Orange piggy-back:

From right terminal of Log Driver board to 1) bottom terminal of Heat Switch and 1) left terminal of Remote Receiver board.

1.

2.

3.

4.

5.

6.

7.

Remove the firebox from the mantel.

Lay unit on its back.

Remove the 12 Philips screws that fasten the bottom cover to the rest of the firebox. There are: two (2) screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (Figure 8). The bottom panel is now free to be removed.

Locate the three (3) light sockets, in the middle of the firebox.

Remove the lightbulbs and place in a safe location.

Trace the light socket wires by cutting the tie wraps and removing the wire covering. Disconnect the wire connectors that are attached to the sockets that are being replaced, noting the associated connection for each wire.

Remove the retaining ring from the light sockets and replace sockets with new sockets.

8. Replace associated wire connectors.

9. Follow steps 1 through 6 in reverse order to reassemble the firebox.

! NOTE: When placing bottom panel back onto unit, position the metal lip from under the control panel between the rubber spacers (attached to the bottom panel) and the sheet metal of the bottom panel.

Heater Assembly Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1.

2.

3.

4.

5.

6.

7.

Remove the firebox from the mantel.

Remove the 10 Philips screws that fasten the top cover to the rest of the firebox. There are: (four) 4 screws at the back of the firebox, along the top; two (2) screws on each side and at the top of the firebox; and two (2) screws on the top of the firebox (Figure 18).

Flip the top panel over and place upside down on the top of the unit. You may experience some resistance as the Heater Assembly is mounted to the top panel and may be a snug fit inside the firebox. Orient yourself with the placement of the Heater Assembly and wiring as shown in Figure 19.

Turn the top panel over and, while supporting the

Heater Assembly and panel in one hand, remove the five (5) Phillips heater mounting screws, noting the center screw is of a larger diameter (Figure 20).

Separate the Heater Assembly from the top panel.

Properly orient the new Heater Assembly and attach it to the top panel using the screws removed in step 5.

Disconnect one of the wire leads from the original

Heater Assembly (which are still connected to parts

15

Figure 18

Screws to Remove

Figure 19

Terminal Block

Wire 1

Wire 2

Heater

Assembly

Heating

Element

Figure 21

3-Position

Switch

Power Cord

Flame Speed

Control

Wire Clamp

Wires leading to bottom assembly Wire 3

Wire 4

Wire 5

Wire 1:

Blue wire connecting top and bottom terminal of

Heater Element on left side.

Wire 2:

Blue wire from top, left terminal of Heater

Element through to lower part of firebox.

Wire 3:

Blue wire connecting inside terminal of Motor to

Terminal Block, matched with blue wire from Terminal

Block to lower part of firebox.

Wire 4:

Black wire from outside terminal of Motor to bottom terminal of Heater Element on right side.

Wire 5:

Yellow wire from top terminal of Heater Element on right side to Terminal Block, matched to yellow wire leading to lower part of firebox.

Figure 20

within the firebox) and immediately connect it to the new Heater Assembly’s terminal, matching its position.

Continue with the remaining wires using the same procedure.

CAUTION: Internal wiring and colors may not be the same within the unit being serviced as those shown. To avoid damage to the unit, damage to property or personal injury, ensure wires are reconnected to match their original locations.

8. Fit Heater Assembly into top of firebox and re-assemble firebox using screws removed in step 2.

Power Cord Replacement

CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin.

WARNINg: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons.

1. Remove the firebox from the mantel.

2.

3.

4.

5.

Lay unit on its back.

Remove the 12 Philips screws that fasten the bottom cover to the rest of the firebox. There are: two (2) screws on each side; two (2) screws on the back panel

(you may have to tip the bottom of the firebox up if it is laying on its back), four (4) screws in the front directly under the control panel; and two (2) screws on the bottom of the firebox (Figure 8). The bottom panel is now free to be removed.

Locate and disconnect the two (2) power cord wire connections. The smooth edged wire leading from the narrow blade of the power plug connects to the middle of the three (3) terminals on the 3-Position Switch; the side of the power cord leading from the wide blade of the plug, and has ridges along its edge leads to the bottom, right terminal of the Flame Speed Control board (Figure 21).

Using pliers, squeeze the sides of the plastic wire clamp on the Power Cord from inside the chassis and push it through the sheet metal.

6.

7.

8.

9.

Release clamp from the Power Cord and remove

Power Cord from the firebox.

Run replacement Power Cord through the firebox as above and connect wire ends as described in step 4.

Leave two (2) inches of slack in cord and secure in place with clamp.

Follow steps 1 through 3 in reverse order to reassemble the firebox.

16

Troubleshooting guide

general

Circuit breaker trips or fuse blows when unit is turned on

Unit turns on or off by itself

Lights dim in room while the unit is on

PROBLEM

Power cord gets warm

Fireplace seems dark side sources.

rating

CAUSE

Short in unit wiring.

Improper circuit current rating

Remote Control has a similar frequency to other remotes in the area.

Radio frequency disturbance from out-

Defective Remote Control Receiver

Unit is drawing close to circuit current

Normal Operation

Defective Power Cord

Improper operation

Defective Light Dimmer

SOLUTION

Trace wiring in unit.

Additional appliances may exceed the current rating of the circuit breaker or fuse. Plug unit into another outlet or install unit on a dedicated 15 amp circuit.

Replace Remote Control. Initialize to Remote Control

Receiver.

Replace Remote Control. Initialize Remote Control and Receiver.

Replace Remote Control Receiver. Initialize Remote

Control and Receiver.

Move the unit to another outlet or install unit on a dedicated 15 amp circuit

The power cord may get slightly warm to the touch when the heater is on

Replace Power Cord if cord gets hot to the touch.

Refer to Operation Section

Replace Light Dimmer Components

Appearance

Fireplace does not turn on Manually

Fireplace does not turn on using the Remote Control

Improper operation

No incoming power from the electrical wall socket

Refer to Operation Section

Check fuse/breaker panel

Defective 3-Position Switch

Improper operation

Replace 3-Position Switch

Refer to Operation Section

Remote Control not initialized to fireplace Initialize the Remote Control

Remote Control not working Install new battery into the Remote Control. Initialize

Remote Control.

Replace Remote Control Receiver or Remote Control, where necessary. Initialize Remote Control and

Remote Control Receiver.

Flame Frozen

Flame not bright or flame not visible

Log set dim, not glowing

(DF2608 Only)

Loose wiring

Defective Flicker Motor

Defective Flame Speed Control

Burnt out light bulbs

Loose wiring

Defective Light Harness

Loose wiring

Defective Log Driver Controller

Flame Shutter

Defective Log Set

Defective Flicker Motor

Light leaking around the log set Log set not positioned properly

Check wiring connections

Replace Flicker Motor

Replace Flame Speed Control Components

Replace light bulbs

Check wiring connections

Replace Light Harness

Check wiring connections

Replace Log Driver Controller

Replace Log Set

Replace Flicker Motor

Check log set for proper fit

17

For service questions, please call Dimplex at 1-888-346-7539.

For sales inquiries, please call Sylvane at 1-800-934-9194 or visit sylvane.com.

PROBLEM

Heater

Heater is not turning off

CAUSE SOLUTION

Heater is not turning on

Heater is turning off after a couple of minutes of operation

Heater emits an odor

Heater fan turns on but heater lacks heat

Heating element is glowing red

Improper operation

Defective Heater Switch

Defective Thermostat

Improper operation

Loose wiring

Defective Heater Switch

Defective Thermostat

Refer to Operation Section

Replace Heater Switch

Replace Thermostat

Refer to Operation Section

Trace wiring in unit

Replace Heater Switch

Replace Thermostat

Defective Heater Assembly Replace Heater Assembly

Build up of dirt/dust in Heater Assembly Ensure that exterior intake louvers and firebox cavity are free of dirt/dust.

Defective Heater Assembly Replace Heater Assembly

Normal Operation Normal operation is when the heater emits an odor for a brief period after the heater is initially turned on.

The heater is burning off any dust accumulated during manufacturing or operation.

Replace Heater Assembly Defective Heater Assembly

Improper operation

Loose wiring

Refer to Operation Section

Trace wiring in unit

Defective Thermostat

Defective Heater Assembly

Normal Operation

Defective heater assembly

Replace Thermostat

Replace Heater Assembly

Small glowing sections of the element are considered normal.

If larger glowing sections are causing the heater to trip the thermal cutout, unplug unit, discontinue use and replace Heater Assembly.

Noise

Excessive noise with the heater on

Dirty Heater Assembly

Grinding or excessive noise with the heater off

Defective Heater Assembly

Flicker rod hitting or rubbing against internal components

Defective Flicker motor

Buzzing noise from control panel Defective Flame Speed Controller

Ensure that exterior intake louvers and firebox cavity are free of dirt/dust.

Replace Heater Assembly

Ensure rod is straight and mounted properly in the bracket, spinning freely away from other components.

Replace if necessary.

Replace Flicker motor

Replace Flame Speed Controller