Maintenance

4.9

Storing the Generator

When

GPi 3200 / 4300

Follow the procedures described below if you intend to take your generator out of service and store it for at least six months.

Tasks

The following tasks must be performed in order to prepare the generator for storage:

1. Drain fuel from the fuel tank.

2. Drain fuel from the carburetor.

3. Change the engine oil.

4. Check for loose or missing fasteners; tighten or replace as needed.

5. Clean the machine.

6. Store the machine.

Prerequisites

„

Engine is stopped and cool to the touch

„

Machine is on a level surface

„

„

Fresh engine oil (see engine operator’s manual)

Clean, dry shop cloths

„

Plastic cloth and containers of sufficient volume to collect drained fuel and oil

Note:

Collect, store and dispose of drained fuel and oil in accordance with current environmental protection regulations.

WARNING

Fire/burn hazards. Gasoline is flammable and can ignite or explode.

f

Keep all open flames, sparks, and cigarettes away from the machine while draining the fuel tank and carburetor.

f

Do not drain fuel while the engine is running or hot.

Draining the fuel tank

Follow the procedure below to drain the fuel tank.

M

M4

wc_gr006814

1. Place a plastic cloth and a collection container beneath the machine.

2. Locate the fuel line

(M4)

. Pinch the fuel line with locking pliers or a hose pincher and disconnect it from the fuel strainer

(M)

.

3. Open the fuel line and drain fuel into the collection container.

48 wc_tx001240gb.fm

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Advanced inverter technology provides clean, stable power for sensitive electronic devices.
  • Compact design and lightweight construction for easy transport and storage.
  • Rugged construction for durability and longevity.
  • Parallel operation capability for increased power output.
  • Fuel-efficient operation for extended runtime.
  • Easy-to-use control panel with LED indicators for monitoring performance.
  • Automatic voltage regulation for consistent power output.
  • Low noise operation for reduced disturbance.

Related manuals

Frequently Answers and Questions

What is the rated power output of the GPi4300?
The GPi4300 has a rated power output of 3300 watts.
What type of fuel does the GPi4300 use?
The GPi4300 uses unleaded gasoline.
How long can the GPi4300 run on a full tank of fuel?
The GPi4300 can run for up to 8 hours on a full tank of fuel at 25% load.

advertisement

Table of contents