Operating the Pull & Hold Dispenser. Bunn LCA-2 IC


Add to my manuals
26 Pages

advertisement

Operating the Pull & Hold Dispenser. Bunn LCA-2 IC | Manualzz

OPERATING THE PULL & HOLD DISPENSER

Set the Function Selector Switch to Normal and the Mode Selector Switch to Run.

1. Pull and Hold Dispense Mode (Cup at a time) a. Place cup on the cup tray beneath the desired dispensing tip. For a large container, flip the cup tray up and place the container on top of the drip tray.

b. Pull and Hold the corresponding dispense handle until the cup or other container is full.

c. Remove cup or container.

2. Portion Dispense Mode (Preset volume dispensing) Refer to Programming Functions on how to set this volume.

a. Place the appropriate size container beneath the desired dispensing tip. For large containers, flip the cup tray up and place the container on top of the drip tray.

b. Momentarily press the Portion Switch. The Portion LED will illuminate for 5 seconds after the Portion

Switch is pressed.

c. Momentarily pull the corresponding dispense handle, then release. If the user waits longer than 5 seconds to pull the handle, the dispenser will default back to the Pull & Hold Mode. Portion Dispense Mode can be disabled at any time during the portion dispense by either momentarily pulling the Dispense Handle again or pressing the Stop button.

d. Wait for container to fill and the dispenser to quit dispensing, then remove container.

Filling Cambros or other large containers:

The dispenser is designed primarily for cups or other small containers that will fit under the dispense tips.

However, it may be used to fill larger containers (up to 2 Gal) by use of an extension hose on the dispense tip.

Care must be taken to insure that the mixed product flows freely from the dispense tip into the container.

1. Use a 5/8” I.D. or larger, NSF (National Sanitation Foundation) approved hose.

2. Use as short a hose as possible with no loops, bends or kinks in it.

3. Insure that the outlet of the hose is below the dispense tip and that the mixed product flows freely into the container

A properly sized and positioned hose will not run full or back up into the dispense tip. Failure to follow these directions can alter the mix ratio and/or cause flooding of the vent tube.

Refer to Programming the Dispenser to set the LF and RT Disp Volumes to the desired amount.

17 38059 050605