26
SERVICE MANUAL AVALON La Petite-X Single-Cup Brewer
6.4.2 Adjusting the Tank Overflow Float
It is important to verify that the float is positioned appropriately in the overflow cup since it can move around in transportation. If this float is not in place the switch will not be activated and the unit will automatically shut down sensing an overflow situation.
It is important to verify that the overflow cup is in place with the highest side in the front and secured with the tape. If you need to remove this cup, please make sure that you replace it with the highest section facing the front and the overflow tube in the cup. This will ensure that the float will “float” and will activate the overflow switch if there is a problem.
6.5 3 Beans canister installation
3 Beans canister
Transmissions
Motors
6.5.1 Install the 3 Beans Canister
Unpack the 3 beans canister.
Remove the tape from transmission.
Install the canister on the shelf by aligning the 3 transmissions of the canister with the
3 motors already fixed on the shelf.
The Petite-X Revision B 03/2010