Corrections. Omega Engineering Dynapro ET 3200 Series, OMWT-SOFT-OPC, M-4066, OMWT Series
Add to my manuals
63 Pages
advertisement
Predefined Corrections
The device type "Thermistor" will default to a correction ID of 128. To override this default you can add a CorrID parameter to the device section of the OMWT-SOFT-
OPC.INI file, or you can set a new default for all thermistors in the Server section of the OMWT-SOFT-OPC.INI file. To change the default CorrectionID for all thermistors add the parameter "DefaultThermistorCorrID=" to the Server section, and set it to whatever CorrectionID you wish.
Predefined Corrections use the following equations. The first equation normalizes the passed value, and the second produces the conversion to degrees Celsius.
Parameters:
NTC_DIVIDERES = 10000
NTC_NORMALRES = 10000
Fitting constants:
A = 3.3539264E-3
B = 2.5609446E-4
C = 1.9621987E-6
D = 4.6045930E-8
R normal
= NTC_DIVIDERES / (32767 / value ) - 1 / NTC_NORMALRES
Value in degrees Celsuis = 1 / ( A + B*R
D*R normal
3 ) normal
+ C*R normal
2 +
OMWT-SOFT-OPC Server Corrections x 57
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13
months from date of purchase. OMEGA’s Warranty adds an additional one (1) month grace period to the normal one (1)
year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action o f the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evide nce of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of
OMEGA’s control. Components which wear are not warranted, includ ing but not limited to�contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES
OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND
ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear ins tallation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING
ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM
OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS ). The assigned AR number should then be marked on the outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
1. Purchase Order number under which the product was
PURCHASED, and
3. Repair instructions and/or specific problem s relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA information available BEFORE contacting OMEGA: repair,
2. Model and serial number of the product, and
3. Repair instructions and/or specific problems relative to the product.
our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2004 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine -readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
58 x Corrections OMWT-SOFT-OPC Server
Where Do I Find Everything I Need for
Process Measurement and Control?
OMEGA…Of Course!
Shop online at www.omega.com
TEMPERATURE
Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
Wire: Thermocouple, RTD & Thermistor
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
Transducers & Strain Gages
Load Cells & Pressure Gages
Displacement Transducers
Instrumentation & Accessories
FLOW/LEVEL
Rotameters, Gas Mass Flowmeters & Flow Computers
Air Velocity Indicators
Turbine/Paddlewheel Systems
Totalizers & Batch Controllers pH/CONDUCTIVITY pH Electrodes, Testers & Accessories
Benchtop/Laboratory Meters
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION
Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Datalogging Systems
Recorders, Printers & Plotters
HEATERS
Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
Flexible Heaters
Laboratory Heaters
ENVIRONMENTAL
MONITORING AND CONTROL
Metering & Control Instrumentation
Refractometers
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment pH, Conductivity & Dissolved Oxygen Instruments
OMWT-SOFT-OPC Server
M-4066/0604
Corrections x 59
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 OWMT-SOFT-OPC
- 7 Overview
- 7 Quick Start
- 9 Description
- 9 OMWT-SOFT-OPC Server and Wireless
- 10 Edit Device
- 11 Receivers
- 11 Device List
- 12 Polling
- 12 Identification
- 12 Filtering
- 13 What is OPC?
- 13 Data Logging
- 13 Diagnostics
- 14 OMWT-SOFT-OPC Main Window
- 14 Main Window
- 14 Setup
- 14 Change Port
- 15 Add/Delete IP Connection
- 16 View IP Connection Status
- 17 Outputs
- 17 New and Edit
- 18 Train
- 19 Search and Add Devices
- 19 ReConfigure Net
- 20 Devices
- 20 Errors
- 20 Quit
- 20 Help
- 21 OMWT-SOFT-OPC Server .INI File Format
- 21 OMWT-SOFT-OPC.ini
- 22 SERVER
- 23 Logging
- 23 IP Addresses
- 23 DIGITAL I/O
- 24 TEMPERATURE Setup
- 25 HUMIDITY
- 26 DIGCOUNTER and Directional Counter
- 27 CNTTEMP
- 28 FASTCNTTEMP
- 29 ALARMTEMP
- 30 Analog Input
- 31 Access/Control Reader
- 32 Repeater
- 32 Dual Discrete Output
- 33 Wireless Analog Output
- 34 OMWT-SOFT-OPC INI Backup
- 35 OMWT-SOFT-OPC Server Tags
- 35 Using OPC Tags
- 35 Device Names
- 37 Device Tag Names
- 37 Temperature
- 38 Digital I/O: DIGITALn
- 39 Temperature/Humidity: HUMIDITYn
- 40 DIGCOUNTER and Directional Counter: DIGCOUNTERn and DIRECTCNTn
- 41 CNTTEMP: CNTTEMPn
- 42 FASTCNTTEMP: FASTCNTTEMPn
- 43 ALARMTEMP: ALARMTEMPn
- 44 AnalogInput: AIn
- 45 Access/Control Reader: IDRn
- 47 Repeater: REPEATERn
- 48 Dual Discrete Output: OUTPUTDISCn
- 49 Wireless Analog Output: OutputAnalogn
- 50 Server Item Names
- 53 OMWT-SOFT-OPC Server Data Logging
- 53 Features
- 54 File Management
- 55 File Format - Data Log
- 56 File Format - Error Log
- 57 OMWT-RECIP Receivers
- 57 Overview of OMWT-RECIP Receivers
- 57 Setting up to use OMWT-RECIP Receivers
- 58 OMWT-RECIP Receiver Notes
- 59 Error Messages
- 59 Communication Errors
- 59 Error In Finding/Initializing Port.
- 59 Cannot Open Communication Port; Already In Use.
- 59 Cannot Find Receiver!
- 59 Cannot find and load lowlevel driver!
- 60 Runtime Errors
- 60 Communication Error: CRC16 or Time Out
- 60 Cannot Find Receiver.
- 60 OMWT-SOFT-OPC Server Internal Error.
- 61 Corrections
- 61 Why Use Corrections
- 61 Correction IDs
- 61 Pre-defined Thermistor
- 62 How to use Corrections
- 62 Correction.INI file
- 62 Thermistor NTC Parameters
- 63 Predefined Corrections