I N S T A L L A T I O N
E L E C T R I C A L C O N N E C T I O N
The appliance must be installed by a qualified service technician. The oven must be properly grounded in accordance with the National Electrical
Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is easily accessible in case of an emergency. Arcing will occur when connecting or disconnecting the unit unless all controls are in the “ off ” position.
Proper receptacle or outlet configuration or permanent wiring for this unit must be installed by a licensed electrician in accordance with applicable local electrical codes.
Supply cords used with this equipment shall be oil-resistant, sheathed flexible cable not lighter than ordinary polychloroprene or other equivalent synthetic elastomer-sheathed cord (Code designation
60245 IEC).
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord and plug, an all-pole country approved disconnection device which has a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring for disconnection. When using a cord without a plug, the green/yellow conductor shall be connected to the terminal which is marked with the ground symbol.
If a plug is used, the socket outlet must be easily accessible. If the power cord needs replacement, use a similar one obtained from the distributor.
For 230V units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization-bonding stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked with the following symbol.
ELECTRICAL - 767-SK vOLTaGE PHaSE cycLE
/
Hz aMPS
kW
120 1 60 16.0 1.9
208-240 ( agcy at 208 at 240
) 1
1
1
60
60
60
15.9
15.5
12.3
3.3
3.2
2.9
230 1 50/60 12.2 2.8 cOrD
&
PLuG
NeMa
5-20 p
20 a
- 125 v plug no cord or plug
Hard wired models:
Hard wired models must be equipped with a country certified external allpole disconnection switch with sufficient contact separation.
cee 7/7
220-230v plug
If a power cord is used for the connection of the product an oil resistant cord like H05RN or H07RN or equivalent must be used.
ELECTRICAL - 1767-SK vOLTaGE PHaSE cycLE
/
Hz aMPS
kW cOrD
&
PLuG
208-240 ( agcy ) 1 at 208 at 240
230
1
1
1
60
60
60
30.8 6.4
31.0 6.5
24.6 5.9
no cord or plug
50/60 24.3 5.6 no cord or plug
NOTE : CE approved appliances must be connected to an electrical circuit that is protected by an external GFCI outlet.
ELECTRICAL - 1000-SK-I vOLTaGE PHaSE cycLE
/
Hz aMPS
kW cOrD
&
PLuG
208-240 ( agcy at 208 at 240
230
) 1
1
1
1
60
60
60
31.4
30.7
24.3
6.5
6.4
5.8
no cord or plug
50/60 24.1 5.5 no cord or plug
ELECTRICAL - 1000-SK/II vOLTaGE PHaSE cycLE
/
Hz aMPS
kW
208-240 ( agcy at 208 at 240
) 1
1
1
60
60
15.7 3.3
15.3 3.2
60 12.1 2.9
230 1 50/60 12.2 2.8
Wire diagrams are located inside the bonnet of the unit .
D A N G E R cOrD
&
PLuG
NeMa 5-20 p
20 a - 125 v plug cee 7/7
220-230v plug
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
D A N G E R
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
APPLICABLE ELECTRICAL CODES.
simple control smokers
• installation
/ operation
/ service manual
- pg
. 10
advertisement
Related manuals
advertisement
Table of contents
- 3 Delivery
- 3 Unpacking
- 4 Safety Procedures and Precautions
- 5 Installation Requirements
- 5 Clearance Requirements
- 6 Dimension Drawings, Weights, Capacity
- 8 Options and Accessories
- 9 Stacking
- 10 Leveling
- 10 Restraint Requirements - Mobile Equipment
- 11 Drip Tray Installation
- 12 Electrical Specifications
- 13 User Safety Information
- 13 Start-Up Operation
- 13 Cooking Oven Characteristics
- 14 Simple Control Operation
- 15 General Holding Guidelines
- 16 Cleaning and Preventative Maintenance
- 17 Protecting Stainless Steel Surfaces
- 17 Cleaning Agents
- 17 Cleaning Materials
- 17 Equipment Care
- 17 Clean Daily
- 17 Clean the Door Vents
- 17 Check Overall Condition of Oven
- 18 Sanitation/Food Safety
- 18 Internal Food Product Temperatures
- 19 Trouble Shooting Checklist
- 24 Electronic Components Service View
- 25 Electronic Components Parts List
- 26 Cable Heating Kits
- 27 767-SK, 1PH, 120V
- 28 767-SK, 1000-Sk/ii, 1PH, 208-240V, 230V
- 30 1767-SK, 1000-SK-I, 1PH, 208-240V, 230V