Specifications
In this section
HP NC380T PCI Express Dual Port Multifunction
Gigabit Server Adapter specifications
Specification Value
Network Controller Chipsets
Bus Type
Bus Width
Bus Speed
Data Transfer Method
Power Requirement
Standards Supported
Dimensions
Connector and Distances
Broadcom 5706C
PCI Express
Four lanes
2.5 GHz
Bus Master DMA
Operating Voltage: +12V +/-8%
Power Consumption: 12.6 Watts
Maximum: 1.05A @ 12V (DC)
IEEE 802.3ab, 802.3ad, 802.3u, 802.3x, 802.3, 802.1p, 802.1q
18.9 cm x 11.1 cm (without bracket) (7.44 x 4.37 inches (L x W))
Two RJ-45 Connectors, Cable and lengths as follows:
10BASE-T: Category 3, 4, or 5 UTP 100 Meters (328 feet)
100BASE-TX: Category 5 UTP 100 Meters (328 feet)
1000BASE-TX: Category 5 UTP 100 Meters (328 feet)
Interrupts Supported
Temperature Range
Automatically configured
Operating: 0°C to 55°C (32°F to 131°F)
Storage: -40°C to 85°C (-40°F to 185°F)
Relative Humidity (non-condensing) Operating: 10% to 90%
Storage: 5% to 95%
Safety Compliance CSA Mark (US and Canada)
CE Mark
EN 60590
UTP cable specifications
To connect to the network, the NC380T uses the following cable for 1000Base-T transmission:
Specifications 11
• CAT5 UTP or better twisted-pair
• 22-26 AWG, 100 Ω @ 1 MHz
• EIA/TIA 568a or EIA/TIA 568b
NOTE: For Gigabit over copper installations, CAT5 UTP or better 1000Base-T cable must comply with the IEEE 802.3ab 1000Base-T standard. For new installations, CAT5e (enhanced
CAT5) or better cable is recommended. Maximum distances for Gigabit over copper cable are
100 meters (328 feet).
RJ-45 pinouts and crossover function
The Ethernet standard also specifies that each segment implement a crossover function to connect the transmitter of one device to the receiver of a device at the other end, and vice-versa. The crossover function may be implemented internally at the hub or switch or externally through the twisted-pair media.
10/100 pinouts using internal, straight-through crossover
If the crossover function is implemented internally, the port is labeled MDI-X (Medium Dependent Interface-
Crossover). When an MDI-X port is connected to an MDI port, the twisted pair media should be wired straight-through using the physical pinouts indicated.
Pin
7
8
4
5
Blue/White
Blue
Brown
Brown/White
7
8
4
5
Specifications 12
10/100 pinouts using external crossover through twisted-pair media
When the crossover function is not provided within the hub or switch, you must implement the crossover through the twisted-pair media using the physical pinouts indicated.
Pin
7
8
4
5
Blue/White
Blue
Brown
Brown/White
Specifications 13
Gigabit over copper pinouts using internal crossover for RJ-45
Unlike connections in which the crossover function is implemented internally at the hub or switch, the
NC380T provides its own automatic crossover function. This means you can wire twisted-pair media straight-through for adapter-to-hub, adapter-to-switch, or adapter-to-adapter connections using the pinouts indicated.
NOTE: To operate at Gigabit speeds, all four pairs of wires must be terminated within the RJ-
45 connector.
Pin
BI_DA+ Orange BI_DA+ 1 1
2
3
4
5
6
7
8
BI_DB+ Green BI_DB+ 3
BI_DC- Blue BI_DC- 5
BI_DD+ Brown BI_DD+ 7
Specifications 14
Gigabit over copper pinouts using external crossover through twisted pair media
When a crossover function is not provided by the adapter, hub or switch, you must implement it through the twisted-pair media using the physical pinouts indicated.
Pin
Specifications 15
Specifications 16
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter User Guide
- 2 Notice
- 3 Contents
- 4 Technician notes
- 5 Where to go for additional help
- 5 HP contact information
- 6 Introduction
- 6 Overview
- 7 LED indicators
- 8 UTP CAT5 cable
- 9 Installing an adapter
- 9 Installation overview
- 9 Preventing electrostatic discharge
- 10 Installing an adapter in a server
- 10 Connecting the network cable
- 11 Specifications
- 11 HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter specifications
- 11 UTP cable specifications
- 12 RJ-45 pinouts and crossover function
- 12 10/100 pinouts using internal, straight-through crossover
- 13 10/100 pinouts using external crossover through twisted-pair media
- 14 Gigabit over copper pinouts using internal crossover for RJ-45
- 15 Gigabit over copper pinouts using external crossover through twisted pair media
- 17 Regulatory compliance notices
- 17 Regulatory compliance identification numbers
- 17 Federal Communications Commission notice
- 17 Class A equipment
- 18 Class B equipment
- 18 Declaration of conformity for products marked with the FCC logo, United States only
- 19 Modifications
- 19 Cables
- 19 Canadian notice (Avis Canadien)
- 19 European Union regulatory notice
- 20 Japanese notice
- 21 Korean class A notice
- 21 Korean class B notice
- 21 BSMI notice
- 21 Disposal of waste equipment by users in private households in the European Union
- 22 Electrostatic discharge
- 22 Overview
- 22 Grounding methods to prevent electrostatic discharge
- 23 Acronyms and abbreviations
- 25 Index