7. Fasten the lower support legs to the cabinet floor with screws
(not provided).
4. Connect the 2 white wires together using UL listed wire connectors.
F C
D
E
A
A. Screw (not provided)
8. Tighten the lower support legs screws.
Make Electrical Connections
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Feed the power supply cable through the conduit connector and into the terminal box.
WARNING
B
A
A. Green or green and yellow ground wire
B. White wires
C. UL listed wire connectors
D. Black wires
E. UL listed or CSA approved conduit connector
F. Downdraft vent wiring
5. Connect the 2 black wires together using UL listed wire connectors.
6. Replace the terminal box cover and secure with screw.
7. Reconnect power.
Check Operation
1. Push and hold the button on the top of the downdraft vent for a few seconds. The retractable section of the downdraft vent will rise, and the blower will start. Position the top trim over the retractable section and snap trim into place.
Trim kits for matching your cooktop color are available from your dealer.
For information on ordering, see the “Assistance or Service” section.
B
A
C
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
3. Connect the green (or green/yellow) ground wire to the green or yellow/green ground wire using UL listed wire connectors.
Tighten the screw on the conduit connector.
E
D
A. Top trim
B. ON/OFF button
C. Blower control slider
D. End cap
E. Filters
2. Slide the control slider on the side of vent to check the operation and speed of the blower.
3. If the blower does not operate:
■ Check that filter or filters are pressed in as far as they will go.
■ Check that the circuit breaker has not tripped or a household fuse blown.
4. Connect vent system to blower. Vent system must end with a wall or roof cap. Use clamps or duct tape to seal all joints.
5. Install cooktop according to manufacturer’s instructions.
Check that rear of cooktop overlaps edge of retractable downdraft vent by ³⁄₈" (9.5 mm). See “Countertop Cutout
Dimensions” in the “Location Requirements” section.
NOTE: To get the most efficient use from your new retractable downdraft vent, read the “Vent System Use” section.
13
advertisement
Related manuals
advertisement
Table of contents
- 2 VENT SYSTEM SAFETY
- 4 INSTALLATION REQUIREMENTS
- 4 Tools and Parts
- 4 Location Requirements
- 7 Electrical Requirements
- 7 Venting Requirements
- 8 INSTALLATION INSTRUCTIONS
- 8 Venting Methods
- 9 Install Vent System
- 11 Rear Mounting - Blower Motor
- 12 Complete Installation
- 13 Make Electrical Connections
- 13 Check Operation
- 14 VENT SYSTEM USE
- 14 Operating Downdraft Vent
- 14 VENT SYSTEM CARE
- 14 Surface of Downdraft Vent
- 14 Filters
- 15 WIRING DIAGRAM
- 16 ASSISTANCE OR SERVICE
- 16 In the U.S.A
- 16 In Canada
- 16 Accessories
- 17 WARRANTY
- 19 SÉCURITÉ DU SYSTÈME DE VENTILATION
- 21 EXIGENCES D'INSTALLATION
- 21 Outils et pièces
- 21 Exigences d’emplacement
- 24 Spécifications électriques
- 24 Exigences concernant l'évacuation
- 25 INSTRUCTIONS D'INSTALLATION
- 25 Méthodes d’évacuation
- 26 Installation du conduit d’évacuation
- 28 Montage du ventilateur à l'arrière
- 29 Achever l’installation
- 30 Raccordements électriques
- 31 Contrôle du fonctionnement
- 31 UTILISATION DU SYSTÈME D’EXTRACTION
- 31 Utilisation du système d’extraction par le bas
- 32 ENTRETIEN DU SYSTÈME D’ÉVACUATION
- 32 Surface du système d’extraction par le bas
- 32 Filtres
- 33 SCHÉMA DE CÂBLAGE
- 34 ASSISTANCE OU SERVICE
- 34 Au Canada
- 34 Accessoires
- 35 GARANTIE