GB
Operation
NOTE
► The appliance vibrates during operation.
Therefore, always put it down during operation. There are four feet on the bottom of the appliance for this purpose.
♦ Remove the required accessories from the accessory compartment .
Switching on and off
Switching the appliance on:
♦ Move the ON/OFF switch into the position
"I" to switch the appliance on. The integrated control lamp lights up.
Switching the appliance off :
♦ Move the ON/OFF switch into the position
"O" to switch the appliance off . The integrated control lamp goes out.
CAUTION!
► Caution! This appliance is not designed for continuous operation. To prevent the motor from overheating, the appliance may only be used as follows: within a period of 10 minutes the appliance may only be operated at the rated power input for 15% of the period, in other words, 1.5 minutes. During the rest of the time period (cooling phase 8.5 minutes), the appliance cools down again.
Compressed air hose with quick coupler
Connecting:
♦ Push the compressed air connector into the quick coupler of the compressed air hose , the sleeve automatically springs forwards.
Cutting:
♦ Pull back the sleeve on the quick coupler of the compressed air hose and remove the compressed air connector .
CAUTION!
► Caution! When disconnecting the quick coupler of the compressed air hose , hold the coupler fi rmly to prevent injuries caused by the hose fl ying off .
Infl ation
with adapter
Schrader valve, car tire valve
Area of use:
This application allows for a simple and accurate infl ation of car tires. The manometer is used to check the tire pressure. Thanks to the integrated release valve it is possible to reduce the tire pressure if it is too high.
ATTENTION!
► Please note, the manometer is not calibrated! After infl ation, always check the tire pressure immediately, for example, at a petrol station.
♦ Ensure that the ON/OFF switch is set to "O".
♦ Press the lever quick coupler downwards to attach it.
♦ Place the lever quick coupler onto the valve and then release the lever.
♦ Insert the mains plug of the compressor into a mains power socket.
♦ Switch the ON/OFF switch to "I". The integrated control lamp lights up.
♦ Read the air pressure from the manometer .
♦ Switch the ON/OFF switch to "O" as soon as the correct or permissible air pressure has been reached. The integrated control lamp goes out.
♦ Press down the lever quick coupler and pull it off the valve.
♦ Remove the mains plug from the mains power socket.
30
PKZ 180 B2
using the valve adapter
Sclaverand valve, race valve
Dunlop valve, bicycle valve
Area of use:
The valve adapter facilitates easy infl ation of bicycle tires.
♦ Use the valve adapter to pump to the valves shown above.
♦ Connect the valve adapter into the lever quick coupler and then release it.
♦ Start by pressing the valve adapter onto the valve.
♦ Infl ate as described above.
using the ball needle / universal adapters
Area of use:
The ball needle can be used to infl ate various balls. The universal adapters can be used to infl ate air mattresses or similar.
♦ Press the lever quick coupler downwards to attach it.
♦ Insert the ball needle or one of the universal adapters into the lever quick coupler and then release it.
♦ Infl ate as described above.
NOTE
► To avoid damage to the valve, you should moisten the ball needle before insertion.
with the extension nozzle
Area of use:
The extension nozzle is used for the cleaning/ blowing out of concealed spaces or hard-to-reach areas, as well as for the cleaning of contaminated equipment. The infi nitely variable trigger allows an exact dosage of the compressed air.
If you want to use the extension nozzle , you must fi rst unscrew the hose with the lever quick coupler from the gun with the manometer .
♦ Now screw on the extension nozzle into the gun with the manometer .
using the adapter nozzle
Area of use:
The adapter nozzle is suitable for all valves with an internal diameter of 8 mm. You can use the adapter nozzle for items such as infl atable mattresses, pools and also boats.
♦ Press the lever quick coupler downwards to attach it.
♦ Insert the nozzle adapter into the lever quick coupler and then release it.
♦ Screw the nozzle adapter into the adapter nozzle .
♦ Infl ate as described above.
using the adapter nozzle
Area of use:
You can use the adapter nozzle for all commercially available bathing boots, kayaks or other large items, such as pools, that are equipped with a screw valve.
♦ Press the lever quick coupler downwards to attach it.
♦ Insert the nozzle adapter into the lever quick coupler and then release it.
♦ Screw the nozzle adapter into the adapter nozzle .
♦ Infl ate as described above.
GB
PKZ 180 B2
31