advertisement
3 Door Entry System Operation
The Brave SlimDP door entry system’s functions are set by establishing
parameters (see the chapter on parameter programming page 23).
3.1 Signalling overview
Brave SlimDP acoustic signals that occur during its operation. Samples of sounds can be listened to in the setting programme ‘BraveSet’.
State Tones Tone frequency
Pick up line type 1
Disconnection of line type 1
Pick up line type 2
Disconnection of line type 2
Confirmation of command from the phone
Ticking during a call
Notice about the end of a call
Relay switch signal
Entry into programming from the phone
Programming from the phone
Parameter confirmation
–▄■▄■▀–
–▀■▄■▄–
–▄■▀–
–▀■▄–
––█––
─┴─┴─
–■–■–■–
─▒▒▒▒▒▒─
–▄■▀–
––▓–▓–––––
––█––
–▄■▀–
980-1333-1650
1650-1333-980
800-1067-1200-1333
1333-1200-1067-800
800
1333
Modulated
980-1067-1180
Modulated
800
Entry into programming from the PC 980-1067-1180
Line connection (Reset)
Error (generally something is not right)
–■–▄–■–
–■–■–■–■–■–
■–
–▄■▄■▄■▄■–
1850-1067-1850
800
Empty memory (no number is programmed) 1300-2100
It is useful to know what tones the Brave SlimDP plays during installation as it will assist in the analysis of its state and operation. The sounds can be turned off in several levels (parameters 61,62,63 and 65).
To play and listen to the sound signals go to: www.alphatech.cz/zvukovasignalizace-3.html
BRAVE SlimDP – User and service manual 19
3.2 Caller at the door
The door entry system’s buttons are labelled in the same way as normal doorbell buttons. Visitor finds the appropriate name (for example Mr Smith) and presses the button. The Brave will pick up a line, "plays" the pick up line tone (if it is not prohibited para.62) and dials the phone number saved under that button (parameter 1 or 2 depending on system regime). From the Brave’s speaker a ringing tone will be heard and Mr Smith’s phone will ring. As soon as Mr Smith picks up he can talk to his visitor. If an electric lock is also connected to the Brave, Mr Smith can press a DTMF code on his phone and let visitor in. If he puts down the phone the Brave will disconnect. If the call lasts longer than the pre-set limit (parameter 52), 10sec before disconnection the
Brave will send a line disconnection tome, but Mr Smith can dial * or #
(parameter 42), to prolonged the call for the length of time set in parameter 52.
The dialled number depends on the regime mode, which is set in the system (parameter 47):
- Regime Day/Night = if the system is in ‘Day’ mode, it dials the number set in parameter 1 , if the system is in ‘Night’ mode, it dials a number set in
parameter 2. The switching over of regimes manually is set in parameters
45,46.
- Regime 2 groups of numbers = the first press of the button always dials a number set in parameter 1. Following the repeated pressing of the same button, when it detects a busy tone (10sec after choice), or after a pre-set number of rings (parameter 56) the system dials a number from the second group (parameter 2). After another press of the same button the system will again dial the number from the first group (or after detecting a busy tone on the dialling of a number from the group 2 the repetition ends).
If a visitor presses the button after the system has picked up, the system will disconnect for a length of time as set in parameter 54 before it picks up the line and dials a new number. The number choice takes place either by tone
(DTMF) or impulse according to the setting in parameter 41. There is one more option, disconnection of line after repeat pressing of the same button
(parameter 4*).
It is possible to control a relay switch (code lock) with the first 4 buttons.
If visitor at the door presses buttons in the correct combination according to a pre-programmed code (parameter 32-34) and the length of time between presses isn’t greater than the pre-set time (parameter 53) the system picks up, switches the appropriate relay (if it is set in mode m=1) for the length of time given in parameter 37 or 39,30 and then disconnects.
Relays can switch on one or two impulses depending on control code
with the length of time between impulses set in parameter 30. See Tab. 1.
20 BRAVE SlimDP – User and service manual
advertisement
Related manuals
advertisement
Table of contents
- 6 BASIC FEATURES
- 9 INSTALLATION
- 9 Name card panel
- 9 Uncover control elements
- 10 Wiring and wall mounting
- 12 Switches
- 13 Voice level
- 15 Covering control elements
- 15 Replacing name card panel
- 17 (COSW)
- 18 Time Relay
- 18 Power supply 12V AC
- 18 Power supply 12V DC
- 18 USB Programming cable
- 19 DOOR ENTRY SYSTEM OPERATION
- 21 Outbound call
- 22 Incoming call
- 22 Door Entry System with keyboard – module SlimKey
- 23 PARAMETER PROGRAMMING
- 23 Entry into the programming
- 23 Parameter programming
- 25 DESCRIPTION OF PROGRAMMABLE PARAMETERS