MTD 128-282R000 Lawn Mower User Manual


Add to my manuals
56 Pages

advertisement

MTD 128-282R000 Lawn Mower User Manual | Manualzz

920-198-01

4

How to operate your Friedrich room air conditioner

(QuietMaster Programmable)

To start unit

1 If your air conditioner is installed and plugged into a proper rec e p t a c l e , ti i s r e a d y t o g o .

T o u c h Power button once. The unit will automatically be in Cool mode with the temperature set at 75°F

(24°C) and the fan speed at F1, the sleep setting. There is a 3minute delay before the compressor will turn on. (See "Automatic

Component Protection" on this page).

2 Should the Check Filter light turn on when you

¿rst turn on the unit, touch Check Filter to turn off the light. Check Filter light will come o n a f t e r 2 5 0 h o u r s o f u s e .

( S e e p a g e 7 f o r ¿ tl e r c l e a n i n g i n s t r u c it o n s ).

Touch Check Filter to reset.

To set mode of operation

3 When you ¿rst turn on the unit, it will be in the Cool mode (light on), with constant fan.

4 Touch MoneySaver

®

(light on) to activate the MoneySaver ® feature.

This cycles the fan with the compressor so that the fan does not r u n a ll t h e it m e .

(MoneySaver ®

T h i s s a v e s e n e r g y a n d i m p r o v e s d e h u m i d i

¿ c a it o n .

will also run the fan to sample the return air temperature if the off cycle is too long). Or you may prefer constant fan for more air movement. To return to constant fan, touch Cool.

5 Touch Fan Only (light on) if you want only the fan to run. You may want to use this feature in conjunction with the Fresh Air / Exhaust lever to bring outside air into a room, or to exhaust stale air. (See page 7, "Fresh

Air and Exhaust Control" for more information.)

To adjust temperature

[60°F (16°C) to 90°F (32°C)]

6

7

8

COOLER – Touch and hold until the display shows the desired room temperature.

WARMER – Touch and hold until the display shows the desired room temperature.

FAHRENHEIT / CELSIUS – Touch ºF / ºC to show the temperature in Celsius, touch again to show Fahrenheit.

To adjust fan speed

9 Touch 1-4 Speed to see current setting. Touch again to change s p e e d .

F 1 i s t h e l o w e s t s e t it n g ( S L E E P S E T T I N G ) , F 2 i s l o w s

(LOW), F3 is medium speed (MED), F4 is high speed (HIGH).

p e e d

To activate smart fan

10

Touch Smart Fan (light on). Smart Fan will adjust the fan speed a u t o m a t i c a l l y t o m a i n t a i n t h e d e s ri e d c o m f o r t l e v e .l

F o r e x a m p l e , fi t h e o u t s i d e d o o r s i n y o u r h o m e a r e o p e n f o r a n e x t e n d e d p e r i o d of time, or more people enter a room, Smart Fan may adjust to a higher fan speed to compensate for the increased heat load. This keeps you from having to adjust the fan speed on your own. Smart

Fan cannot be activated in the Fan Only mode.

To deactivate smart fan

11

Touch 1-4 Speed, and select your desired fan speed.

To set hour clock

12 Press Set Hour once to see the current clock setting. Continue pressing the button until the hour closest to the actual time appears in the display.

MAKE SURE YOU SET A.M. AND P.M. PROPERLY. A light will appear in the upper left corner of the display when the hour is P.M.

NOTE: Minutes will NOT show on display.

Figure 3

DISPLAY

1

3

6

9 11

13

PM

Mode

Temp

Fan

Timer

Cool

1-4

Speed

A/C

Stop

Set

Hour

Check

Filter

Press to reset

Power

Money

Saver

®

Smart

Fan

A/C

Start

Fan

Only

O

F /

O

C

Timer

On/Off

2

12

4

5

To set the timer

NOTE:

S e t H o u r c l o c k b e f o r e a t t e m p t i n g t o s e t it m e r f u n c it o n s .

You can set the A/C Start and A/C Stop apart and a maximum of 23 hours apart.

it m e r a m i n i m u m o f o n e h o u r

13

TIMER STOP - Press the A/C Stop button and continue pressing until the hour you want the unit to shut off appears in the display

(A.M. or P.M.). The stop time for cooling will then be set.

14

START TIME - Press A/C Start to view the current start time for cooling. Continue pressing until the hour you want the unit to start appears in the display (A.M. or P.M.). The start time for cooling will then be set.

15

Press the Timer On/ Off button once to activate (light on) the timer function. Touch Timer On/ Off again (light off) to cancel the timer f u n c it o n fi y o u s o d e s ri e .

O n c e t h e o n a n d o f f it m e s h a v e b e e n s lected, they will remain in memory, and cycle daily until changed.

e -

NOTE:

I f m u s t b e u n r e s e t ti i s o r t u n p l h e u g g e d o r p o w e r i s i n t e r r u p t e d , t h e Set Hour button

Timer On/ Off functions will not work.

Automatic component protection

Y o u r u n ti i s e q u i p p e d w ti h A u t o m a it c C o m p o n e n t P r o t e c it o n .

To protect the compressor of the unit, there is a three minute time delay if you turn the unit off or if power is interrupted. The fan will not be affected.

8

7

10

14

15