RUGGEDCOM RSG2300


Add to my manuals
46 Pages

advertisement

RUGGEDCOM RSG2300 | Manualzz

RUGGEDCOM RSG2300

Installation Guide

Chapter 4

Technical Specifications

Section 4.4.2

Copper Gigabit Ethernet (1 Gbps) Port Specifications

NOTE

• Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances.

• All optical power numbers are listed as dBm averages.

• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).

Fixed Gigabit Transceivers

Connector Duplex

j

Cable Type

k

RJ45 FDX/HDX > CAT-5 j

Auto-Negotiating

k

Shielded or unshielded.

l

Auto-crossover and auto-polarity.

m

Typical distance. Dependent on the number of connectors and splices.

n

RMS 1 minute.

SFP Gigabit Transceivers

Connector Duplex

o

RJ45 o

Auto-Negotiating

p

Shielded or unshielded.

q

Auto-crossover and auto-polarity.

r

RMS 1 minute.

FDX/HDX

Cable Type

p

> CAT-5

Wiring Standard

l

TIA/EIA T568A/B

Maximum

Distance

m

100 m (328 ft)

Wiring Standard

q

TIA/EIA T568A/B

Maximum Distance

100 m (328 ft)

Isolation

n

1.5 kV

Isolation

r

1.5 kV

Section 4.5

Fiber Optic Ethernet Port Specifications

The following sections list specifications of the optical transceivers used in the dual-port modules available for the

RSG2300:

Section 4.5.1, “10FL Ethernet Optical Specifications”

Section 4.5.2, “Fast Ethernet (10/100 Mbps) Optical Specifications”

Section 4.5.3, “Gigabit Ethernet (1 Gbps) Optical Specifications”

Copper Gigabit Ethernet (1 Gbps) Port Specifications 29