- No category
advertisement
RUGGEDCOM RSG2300
Installation Guide
Chapter 4
Technical Specifications
Section 4.4.2
Copper Gigabit Ethernet (1 Gbps) Port Specifications
NOTE
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances.
• All optical power numbers are listed as dBm averages.
• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
Fixed Gigabit Transceivers
Connector Duplex
j
Cable Type
k
RJ45 FDX/HDX > CAT-5 j
Auto-Negotiating
k
Shielded or unshielded.
l
Auto-crossover and auto-polarity.
m
Typical distance. Dependent on the number of connectors and splices.
n
RMS 1 minute.
SFP Gigabit Transceivers
Connector Duplex
o
RJ45 o
Auto-Negotiating
p
Shielded or unshielded.
q
Auto-crossover and auto-polarity.
r
RMS 1 minute.
FDX/HDX
Cable Type
p
> CAT-5
Wiring Standard
l
TIA/EIA T568A/B
Maximum
Distance
m
100 m (328 ft)
Wiring Standard
q
TIA/EIA T568A/B
Maximum Distance
100 m (328 ft)
Isolation
n
1.5 kV
Isolation
r
1.5 kV
Section 4.5
Fiber Optic Ethernet Port Specifications
The following sections list specifications of the optical transceivers used in the dual-port modules available for the
RSG2300:
•
Section 4.5.1, “10FL Ethernet Optical Specifications”
•
Section 4.5.2, “Fast Ethernet (10/100 Mbps) Optical Specifications”
•
Section 4.5.3, “Gigabit Ethernet (1 Gbps) Optical Specifications”
Copper Gigabit Ethernet (1 Gbps) Port Specifications 29
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 7 1.1 Feature Highlights
- 8 1.2 Ports, Controls and Indicator LEDs
- 11 2.1 Mounting the Device
- 12 2.1.1 Mounting the Device to a Rack
- 13 2.1.2 Mounting the Device on a DIN Rail
- 13 2.1.3 Mounting the Device to a Panel
- 14 2.2 Connecting Power
- 15 2.2.1 Connecting AC Power
- 16 2.2.2 Connecting DC Power
- 18 2.2.3 Wiring Examples
- 20 2.3 Connecting the Failsafe Alarm Relay
- 21 2.4 Grounding the Device
- 21 2.5 Connecting to the Device
- 22 2.6 Cabling Recommendations
- 23 2.6.1 Protection On Twisted-Pair Data Ports
- 23 2.6.2 Gigabit Ethernet 1000Base-TX Cabling Recommendations
- 26 3.1 Copper Ethernet Ports
- 27 3.2 Fiber Optic Ethernet Ports
- 27 3.3 SFP Optic Ethernet Ports
- 28 3.3.1 Installing an SFP Optical Port
- 29 3.3.2 Removing an SFP Optical Port
- 30 3.4 GBIC Optic Ethernet Ports
- 30 3.4.1 Installing a GBIC Optical Port
- 31 3.4.2 Removing a GBIC Optical Port
- 33 4.1 Power Supply Specifications
- 33 4.2 Failsafe Relay Specifications
- 34 4.3 Supported Networking Standards
- 34 4.4 Copper Ethernet Port Specifications
- 34 4.4.1 Copper Fast (10/100 Mbps) Ethernet Port Specifications
- 35 4.4.2 Copper Gigabit Ethernet (1 Gbps) Port Specifications
- 35 4.5 Fiber Optic Ethernet Port Specifications
- 36 4.5.1 10FL Ethernet Optical Specifications
- 36 4.5.2 Fast Ethernet (10/100 Mbps) Optical Specifications
- 37 4.5.3 Gigabit Ethernet (1 Gbps) Optical Specifications
- 38 4.6 Operating Environment
- 38 4.7 Mechanical Specifications
- 43 6.1 Agency Approvals
- 43 6.2 FCC Compliance
- 43 6.3 Industry Canada Compliance
- 44 6.4 EMI and Environmental Type Tests