4.3.2 Putting out of service
When not using the generating set for a longer period it is recommended to execute an engine preservation procedure.
1 Clean the engine.
2 Loosen the fuel suction pipe and fuel return and put them in a can with preservation diesel fuel. Start the engine and run the engine warm.
3 Drain the hot engine oil and refill with preservation oil.
4 Stop the engine and take loose the inlet of the raw water pump. Drain the water from the water lock.
Crank the engine having the raw water inlet sucking
MAINTENANCE anti freeze from a can until the pump, heat exchanger and manifold are filled.
5 The coolant can stay in the engine
6 Disconnect the battery and store it in a place free of frost and dry and charge it regularly.
7 Close inlet- and outlet openings with tape.
8 Protect the generating set against the influences of bad weather conditions.
This method of preservation will be sufficient for 6 months.
Repeat steps 2, 3, and 4, every 6 months. Change oil before using the engine again.
EN / M-SQ8 & 10 / January 2010
25
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 INTRODUCTION
- 4 General
- 4 Service and maintenance
- 4 Guarantee
- 5 Liability
- 6 Identification
- 6 General
- 6 Identification plate
- 7 INFORMATION
- 7 Safety
- 7 General
- 7 Electrical safety
- 7 Earth insulation failures
- 7 Installation
- 8 Operation
- 8 Fire and explosion
- 8 Chemicals
- 9 Transport, lifting and storage
- 9 Features
- 9 Remote control
- 9 Documentation
- 9 Accessories included in the standard delivery
- 10 Components
- 10 Main components to identify
- 12 Generator control panel
- 12 Remote control panel
- 12 Technical Information
- 12 AC alternator
- 12 Engine
- 12 Digital Diesel Control system
- 12 Battery charger
- 13 Alarms and shut down
- 13 Control
- 13 Remote control
- 13 Hour counter
- 13 Load indicator
- 13 Fuel specification
- 13 Oil information
- 13 Cooling liquid
- 14 Technical data
- 15 Wiring codes and colours
- 16 Lay out control wiring
- 17 Electrical diagram 230 V AC / 50 Hz
- 19 OPERATION
- 19 General
- 19 Operating Instructions
- 19 Summarised operating instructions (daily use)
- 19 Extended operating instructions
- 22 MAINTENANCE
- 22 Alternator
- 22 Engine
- 22 Preliminary instructions
- 22 Bleeding fuel lines
- 22 Valve clearance
- 22 Replacing fuel filter
- 22 Replacing oil filter
- 23 Readjustment V-beltplacing oil filter
- 23 Regular maintenance
- 24 Maintenance schedule
- 25 Putting out of service
- 26 TROUBLE SHOOTING
- 26 Alternator/ electrical faults
- 26 General
- 26 Trouble shooting table
- 27 Engine faults
- 27 General
- 28 Trouble shooting table
- 30 Warnings
- 30 Service address
- 31 Special procedures alternator
- 31 only)
- 31 Testing rotary rectifier diodes
- 31 Winding resistant values
- 31 Meggering
- 31 Special procedures engine
- 32 Adjusting valve clearance and retightening the cylinder head bolts
- 32 Measuring exhaust backpressure
- 33 Disassembling instructions
- 34 SPARE PARTS LIST
- 36 MAINTENANCE LOG