N. SAFETY RELIEF VALVE BLOWS AT TOO LOW PRES
PROBABLE CAUSE
Valve not properly sated
Valve defective
0.
MAGNETIC STARTER SWITCH FAILS TO
OPERATE
PROBABLE CAUSE
Magnetic starter switch defective
Thermal relay heater defective
POSSIBLE REMEDY
Drain air and valve will reseat
Replace valve
POSSIBLE REMEDY
Replace or repair starter switch (Sect. IX, Para. B)
Install a new thermal relay eat(Sect. IX, Para. C)
SECTION VIII
MAINTENANCE
ELECTRIC MOTOR AND COMPRESSOR
A. GENERAL
The electric motor can Be removed from the air receiver tank as a unit after removal of the V-belt guard, belts, conduit, and mounting brackets. The air compressor assembly can be removed as a unit after the
V-belt guard, belts and aftercooler tube are removed.
B. ELECTRIC MOTOR
1.
Removal. Remove the electric motor a instructed on
figure 11.
2.
Installation. Install the electric motor as instructed on
figure 11.
C. COMPRESSOR ASSEMBLY
1.
Removal. Remove the compressor assembly as
instructed on figure 11.
2.
Installation. Install the compressor assembly as
instructed on figure 11.
Figure 11. Electric motor and compressor assembly, removal and installation.
12