Identification Stamolys CA71SI

2 Identification

2.1

Device designation

2.1.1

Nameplate

Compare the (extended) order code on the nameplate (on the analyzer) to the product structure and your order.

You can read the following information from the nameplate:

• Order code

• Extended order code (=order code from the product structure)

• Serial number

• Measuring range

• Outputs and communication

• Power supply

• Ingress protection

• Environment conditions

2.1.2

Product structure

CA71SI-

A

B

Y

Measuring range

1.0 to 200 μg/l SiO

2

50 to 5000 μg/l SiO

2

Special version acc. to customer’s specification

Sample transfer

1

2

From one measuring point (one channel version)

From two measuring points (two channel version)

Power supply

0

1

2

3

230 V AC / 50 Hz

115 V AC / 60 Hz

115 V AC / 50 Hz

230 V AC / 60 Hz

Collecting vessel (for up to 3 analyzers)

A

B

C

D

Not selected (without collecting vessel)

Collecting vessel without level measurement

Collecting vessel with level measurement (one-channel version only)

Two collecting vessels without level measurement (two-channel version)

Housing

1

2

3

Open design

GFR housing

Stainless steel (1.4301 / AISI 304) + purge

Output

A 0/4 to 20 mA, RS 232

Reagents

1

2

3

To order separately

One set, inactive

Three sets, inactive

complete order code

Endress+Hauser

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • - Measures silicate concentration in ultrapure water
  • - Photometric measurement principle
  • - Measuring range: 0.01 - 1000 µg/l SiO2
  • - Compact and wall-mountable design
  • - Easy-to-use interface with clear display
  • - Automatic calibration and cleaning functions
  • - Low maintenance and operating costs

Related manuals

Frequently Answers and Questions

What is the measuring range of the analyzer?
The measuring range is 0.01 - 1000 µg/l SiO2.
How often does the analyzer need to be calibrated?
The analyzer has automatic calibration functions, but the frequency of calibration may vary depending on the application.
What is the power supply requirement of the analyzer?
The power supply requirement is specified in the technical data section of the manual.
Can the analyzer be used in hazardous areas?
The manual does not provide information on the suitability of the analyzer for hazardous areas.