Real Fyre 01V Remote Owner's Manual

Add to my manuals
8 Pages

advertisement

Real Fyre 01V Remote Owner's Manual | Manualzz

OWNER’S

MANUAL

01

V Remote Electronic Ignition and Control System

A. BEFORE OPERATING verify that no gas is in the area around the appliance, including near the fl oor.

WHAT TO DO IF YOU SMELL GAS:

• Open a window.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in the building.

• Immediately call the gas supplier from a neighbor’s phone. Follow gas supplier’s instructions.

• If you cannot reach the gas supplier, call the fi re department.

B. Use only your hand to push in or turn the gas control knobs. Never use tools. If a knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fi re or explosion.

C. Do not use this control or any gas appliance if any part has been under water or in contact with water. Immediately call a qualifi ed service technician to replace the control system and any gas control system which has been under water or in contact with water.

D. These instructions are to be referenced as a user guide in addition to the burner system owner's manual.

WARNING

Fire or explosion hazard. Attempted disassembly or repair of controls can cause property damage, severe injury or death. Do not disassemble the gas valve; it contains no serviceable components.

IMPORTANT: Read these instructions carefully.

Failure to follow them could result in a fi re or explosion causing property damage, personal injury, or loss of life. The product must be installed and operated according to all local regulations.

ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746

REV 2 - 1003150827 1 L-F2-108

APPLICATION

The 01V remote system is a battery-powered electronic remote ignition and control system for gas appliances with pilot burners and ODS systems.

GENERAL NOTES

Radio Frequency Remote

433.92 MHz for Europe; 315 MHz for U.S. (FCC 10: RTD-G6R) and for Canada (IC: 4943A-G6R).

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifi cations not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Batteries - Remote Handset:

1 x 9V block (quality alkaline recommended)

Batteries - Receiver:

4 x 1.5V "AA" (quality alkaline recommended)

AUTOMATIC OPERATION

IMPORTANT: Wiring of valve and receiver must be completed before starting ignition. Failure to do so could damage the electronics.

Note:

This remote handset and receiver is not interchangeable with previous versions.

Please also refer to the burner system owner's manual.

SETTING THE ELECTRONIC CODE

(First time use only)

Radio Frequency Remote

(see Fig. 3-1)

A code is selected automatically for all remote systems from among 65,000 random codes available. The receiver has to learn the code of the handset:

• Press and hold the receiver's reset button (Fig. 2-1) until you hear two (2) acoustic signals. After the second, longer acoustic signal, release the reset button.

• Within the subsequent 20 seconds press the (small fl ame) button on the remote handset until you hear an additional long signal confi rming the code is set.

Note:

This is a one time setting only, and is not required when changing the batteries in the remote or receiver.

Fig. 2-1 Receiver reset button

REV 2 - 1003150827 2 L-F2-108

AUTOMATIC OPERATION (Cont.)

TO TURN ON APPLIANCE

Warning: When pilot ignition is confi rmed, motor turns automatically to maximum fl ame height.

• Turn MANUAL knob to the ON, full counterclockwise

position (see Fig. 5-2).

• Place ON/OFF switch in (ON position). See Fig.

3-2.

• Simultaneously press and hold the OFF and

(large fl ame) buttons until a short acoustic signal confi rms the start sequence has begun; release buttons (see Fig. 3-1).

• Continuing signals confirm the ignition is in process.

• Once pilot ignition is confi rmed, there will be main gas fl ow.

• After the ignition the remote will go automatically into temperature control mode.

Fig. 3-1 Remote handset detail

Cutout for pilot gas adjustment

TO TURN OFF APPLIANCE

Press OFF button on remote handset.

Note:

Press (small fl ame) to turn main gas to pilot gas.

MANUAL knob in position for automatic ignition

ADJUSTMENT - FLAME HEIGHT

(see Fig. 3-1)

Fig. 3-2 Combination control, view manual knob

• In standby mode: Press (large fl ame) to increase fl ame height.

• Press (small fl ame) to decrease fl ame height or to set appliance at pilot fl ame.

• For fi ne adjustment tap the large/small fl ames.

SETTING THE TIME

(see Fig. 3-1)

• The display will fl ash after either: a. Installing the battery or b. Simultaneously pressing the (large fl ame)

and (small fl ame).

SETTING

°

C/24 HOUR OR

°

F/12 HOUR CLOCK

(see Fig. 3-1)

• Press OFF and (small flame) until display changes from Fahrenheit/12 hour clock to

Celsius/24 hour clock and vice versa.

(small fl ame) to set the minute.

• Press OFF to return to manual mode or simply wait and it will automatically return to the manual mode.

REV 2 - 1003150827 3 L-F2-108

AUTOMATIC OPERATION (cont.)

CHANGING THE MODE OF OPERATION SETTING THE TEMPERATURE

Briefl y pressing the SET button changes the mode of operation in the following order:

MAN TEMP TEMP TIMER and back to MAN

• Select either the TEMP MODE or the

TEMP

MODE by briefl y pressing the SET button.

• Hold the SET button until the TEMP display fl ashes.

Note:

MANUAL mode can also be reached by pressing either the (large fl ame) or the (small fl ame).

• Set the desired temperature with (large fl ame) or (small fl ame).

• Press OFF or simply wait to complete programming.

MAN Mode - Manual Flame Height Adjustment

SETTING THE TIMER

• Press (large fl ame) to turn on the main burner.

• Press (large fl ame) to increase the fl ame height.

• Select Timer mode by briefl y pressing the SET button.

• Press (small fl ame) to decrease the fl ame height or to go to pilot standby position.

• Press and hold the SET button until the P1 (sun symbol is displayed) and the time fl ashes. S e t

Note:

While pressing either button a symbol the hour by pressing the (large fl ame) and set indicating transmission appears on the display. The receiver confi rms transmission with an acoustic signal.

the minutes by pressing the (small fl ame).

• Briefl y press SET button for the next burner cycle time.

TEMP - Daytime Temperature Mode

P2 (sun symbol) and P2 (moon symbol).

• Once all four (4) times are set, press OFF or simply

(appliance must be in standby mode; pilot ignited):

The room temperature is measured and compared to the set temperature. The fl ame height is then automatically adjusted to achieve the Daytime set temperature.

wait to complete programming.

TEMP

- Nighttime Setback Temperature Mode

(appliance must be in standby mode; pilot ignited):

The room temperature is measured and compared to the Nighttime Setback temperature. The fl ame height is then automatically adjusted to achieve the

Nighttime Setback temperature.

TIMER - Timer Mode

(appliance must be in standby mode; pilot ignited):

The Timer setting allows you to set two (2) burner

TEMP times and two (2) burner TEMP times every 24 hours.

For

TEMP

to operate as a thermostat, TEMP must be set at 40°F 4°C) or higher.

If the

TEMP

setting is decreased to -- , the motor will turn the valve to the standby position in the moon times and await the next burner TEMP cycle.

Note:

The display shows the set temperature every

30 seconds.

REV 2 - 1003150827 4 L-F2-108

(Only possible, when MANUAL knob is used)

Follow the burner system owner's manual for gaining access to the gas control and the pilot burner. Access to the pilot burner is only required for ignition with a match.

When turning main valve knob, do not force. Knob has a slip clutch that clicks until the end stops are reached.

This allows for manual fl ame height adjustment as well as adjustment to pilot standby position (see Fig.

5-1).

1. STOP! Read the safety information included before

proceeding.

2. Turn main valve knob to the OFF, full clockwise

position.

3. Turn MANUAL knob to the MAN, full clockwise

position.

4. Place ON/OFF switch in (OFF position).

5. Wait fi ve (5) minutes to clear out any gas. Verify that no gas is in the area around the appliance, including near the fl oor. If you detect gas STOP!

Follow "A" in the safety information on page 1. If no gas is present, proceed to step 6.

6. Place ON/OFF switch in (ON position).

7. With the MANUAL knob in MAN position a manual pilot valve operator and piezo igniter (optional) are accessible.

8. Change the ignition cable from the receiver (see

Fig.5-2a) to the valve (see Fig. 5-2b).

9. Fully push down manual pilot valve operator (using a small bladed screwdriver or similar) and hold in, to start pilot gas fl ow (see Fig. 5-1).

Piezo igniter

ON/OFF switch

(optional) in

ON position

8 wire receiver jack microswitch

Fig. 5-1 Combination control, cover

A.

B.

Fig. 5-2a/b Piezo igniter wiring

Connection piezo igniter tab 2.8 x 0.8 mm

MANUAL knob in MAN position

Manual pilot valve operator

Main valve knob in OFF position

Ignition with match:

Immediately light the pilot with a match, while continuing to hold in the manual pilot valve operator for about one (1) minute after the pilot is lit. Release manual pilot valve operator. If pilot does not stay lit, wait fi ve (5) minutes and repeat.

Ignition with piezo igniter:

12. lf the appliance will not operate, follow the instructions "TURN OFF GAS TO APPLIANCE" and call the service technician or gas supplier.

PRIOR TO ANY FUTURE AUTOMATIC

OPERATION; THE IGNITION CABLE MUST

BE CONNECTED BACK TO THE RECEIVER

(WHEN COOL).

Use the push piezo igniter to ignite. If pilot does not stay lit, wait fi ve (5) minutes and repeat.

Note: If the pilot does not stay lit after several

tries, follow the instructions "TURN OFF

GAS TO APPLIANCE" and call the service technician or gas supplier.

TURN OFF GAS TO APPLIANCE

• Press OFF button on remote.

• Follow burner system owner's manual for gaining accessibility to the gas control.

10.Turn MANUAL knob to the ON, full counterclockwise

position.

• Place ON/OFF switch in (off position).

11. Turn main valve knob to the full ON, full counterclockwise position.

• Turn main valve knob to the OFF full clockwise

position.

REV 2 - 1003150827 5 L-F2-108

MISCELLANEOUS

Low Battery Indication

Receiver: three short beeps will sound when motor turns

Remote with display:

"BATT" will appear on display

Note:

If the battery of the handset is low or if the transmitter is out of the communication range, the motor turns down the valve to pilot gas after 6 hours.

Note:

With very low battery the O1V system shuts off the fi re completely. This will not happen if the power supply is interrupted.

Battery Replacement

Battery replacement is recommended at the beginning of each heating season. Pull ribbon to remove batteries.

Do not use metal tools to remove batteries. Using a metal tool could cause a short that may damage the receiver.

Location of Receiver

When the RF-receiver is placed in the appliance, the surrounding metal can reduce reception considerably.

The position of the antenna on the receiver also infl uences reception. It is recommended to straighten the antenna. The antenna must not come in contact or cross the ignition wire, this may render the receiver inoperable.

REV 2 - 1003150827 6 L-F2-108

MANUAL Knob

Piezo Igniter (optional)

Connection for manual ignition

Main Valve

Knob

Combination Control

REV 2 - 1003150827

Thermocouple

Interrupter Block

Ignition Cable

ON/OFF Switch (optional)

OFF

ON

8 Wire Cable

Thermo Current Cable #2 or ON/OFF Switch with

Soldered Cable

Thermo Current Cable #1

RF Antenna

SPARK SW TC

SPARK

ON/OFF

Switch

SW TC

Thermocurrent

Interrupter Block

Pilot

GV 60

Receiver

4 AA Batteries

Battery Compartment

Button "RESET"

MA

GR

MO

SW

7

Fig. 7-1 Wiring Diagram

L-F2-108

NOTES PAGE

Please use this page to record any information about your remote system that you may want to have at hand.

REV 2 - 1003150827 8 L-F2-108

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What is the purpose of the Real Fyre 01V Remote?
The Real Fyre 01V Remote is a battery-powered electronic remote ignition and control system for gas appliances.
What is the procedure for setting the electronic code for the remote?
Press and hold the receiver's reset button until you hear two acoustic signals. Within 20 seconds, press the small flame button on the remote handset until you hear a long signal confirming the code is set.
How do I turn on the appliance using the remote?
Turn the MANUAL knob to the ON, full counterclockwise position, place the ON/OFF switch in the ON position, simultaneously press and hold the OFF and large flame buttons until a short acoustic signal confirms the start sequence has begun.
How do I adjust the flame height?
In standby mode, press the large flame button to increase flame height and the small flame button to decrease flame height.
How do I change the mode of operation from manual to automatic?
Briefly press the SET button until the TEMP display flashes, then set the desired temperature with the large and small flame buttons.
How do I set the timer mode?
Select Timer mode by briefly pressing the SET button, then press and hold the SET button until P1 is displayed and the time flashes. Set the hour with the large flame button and the minutes with the small flame button, then repeat for burner cycle times P2, P3, and P4.
Download PDF

advertisement