Add to my manuals8 Pages
Real Fyre 01V is a battery-powered electronic remote ignition and control system for gas appliances with pilot burners and ODS systems. It features a radio frequency remote with a range of up to 30 feet, allowing you to control your gas appliance from anywhere in the room. The system includes a receiver that mounts near the appliance and connects to the gas valve and pilot burner. With the Real Fyre 01V, you can easily turn your appliance on and off, adjust the flame height, set the temperature, and program a timer for automatic operation.
advertisement
OWNER’S
MANUAL
01
V Remote Electronic Ignition and Control System
A. BEFORE OPERATING verify that no gas is in the area around the appliance, including near the fl oor.
WHAT TO DO IF YOU SMELL GAS:
• Open a window.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in the building.
• Immediately call the gas supplier from a neighbor’s phone. Follow gas supplier’s instructions.
• If you cannot reach the gas supplier, call the fi re department.
B. Use only your hand to push in or turn the gas control knobs. Never use tools. If a knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fi re or explosion.
C. Do not use this control or any gas appliance if any part has been under water or in contact with water. Immediately call a qualifi ed service technician to replace the control system and any gas control system which has been under water or in contact with water.
D. These instructions are to be referenced as a user guide in addition to the burner system owner's manual.
WARNING
Fire or explosion hazard. Attempted disassembly or repair of controls can cause property damage, severe injury or death. Do not disassemble the gas valve; it contains no serviceable components.
IMPORTANT: Read these instructions carefully.
Failure to follow them could result in a fi re or explosion causing property damage, personal injury, or loss of life. The product must be installed and operated according to all local regulations.
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
REV 2 - 1003150827 1 L-F2-108
APPLICATION
The 01V remote system is a battery-powered electronic remote ignition and control system for gas appliances with pilot burners and ODS systems.
GENERAL NOTES
Radio Frequency Remote
433.92 MHz for Europe; 315 MHz for U.S. (FCC 10: RTD-G6R) and for Canada (IC: 4943A-G6R).
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Changes or modifi cations not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Batteries - Remote Handset:
1 x 9V block (quality alkaline recommended)
Batteries - Receiver:
4 x 1.5V "AA" (quality alkaline recommended)
AUTOMATIC OPERATION
IMPORTANT: Wiring of valve and receiver must be completed before starting ignition. Failure to do so could damage the electronics.
Note:
This remote handset and receiver is not interchangeable with previous versions.
Please also refer to the burner system owner's manual.
SETTING THE ELECTRONIC CODE
(First time use only)
Radio Frequency Remote
(see Fig. 3-1)
A code is selected automatically for all remote systems from among 65,000 random codes available. The receiver has to learn the code of the handset:
• Press and hold the receiver's reset button (Fig. 2-1) until you hear two (2) acoustic signals. After the second, longer acoustic signal, release the reset button.
• Within the subsequent 20 seconds press the (small fl ame) button on the remote handset until you hear an additional long signal confi rming the code is set.
Note:
This is a one time setting only, and is not required when changing the batteries in the remote or receiver.
Fig. 2-1 Receiver reset button
REV 2 - 1003150827 2 L-F2-108
AUTOMATIC OPERATION (Cont.)
TO TURN ON APPLIANCE
Warning: When pilot ignition is confi rmed, motor turns automatically to maximum fl ame height.
• Turn MANUAL knob to the ON, full counterclockwise
position (see Fig. 5-2).
• Place ON/OFF switch in (ON position). See Fig.
3-2.
• Simultaneously press and hold the OFF and
(large fl ame) buttons until a short acoustic signal confi rms the start sequence has begun; release buttons (see Fig. 3-1).
• Continuing signals confirm the ignition is in process.
• Once pilot ignition is confi rmed, there will be main gas fl ow.
• After the ignition the remote will go automatically into temperature control mode.
Fig. 3-1 Remote handset detail
Cutout for pilot gas adjustment
TO TURN OFF APPLIANCE
Press OFF button on remote handset.
Note:
Press (small fl ame) to turn main gas to pilot gas.
MANUAL knob in position for automatic ignition
ADJUSTMENT - FLAME HEIGHT
(see Fig. 3-1)
Fig. 3-2 Combination control, view manual knob
• In standby mode: Press (large fl ame) to increase fl ame height.
• Press (small fl ame) to decrease fl ame height or to set appliance at pilot fl ame.
• For fi ne adjustment tap the large/small fl ames.
SETTING THE TIME
(see Fig. 3-1)
• The display will fl ash after either: a. Installing the battery or b. Simultaneously pressing the (large fl ame)
and (small fl ame).
SETTING
°
C/24 HOUR OR
°
F/12 HOUR CLOCK
(see Fig. 3-1)
• Press OFF and (small flame) until display changes from Fahrenheit/12 hour clock to
Celsius/24 hour clock and vice versa.
(small fl ame) to set the minute.
• Press OFF to return to manual mode or simply wait and it will automatically return to the manual mode.
REV 2 - 1003150827 3 L-F2-108
AUTOMATIC OPERATION (cont.)
CHANGING THE MODE OF OPERATION SETTING THE TEMPERATURE
Briefl y pressing the SET button changes the mode of operation in the following order:
MAN TEMP TEMP TIMER and back to MAN
• Select either the TEMP MODE or the
TEMP
MODE by briefl y pressing the SET button.
• Hold the SET button until the TEMP display fl ashes.
Note:
MANUAL mode can also be reached by pressing either the (large fl ame) or the (small fl ame).
• Set the desired temperature with (large fl ame) or (small fl ame).
• Press OFF or simply wait to complete programming.
MAN Mode - Manual Flame Height Adjustment
SETTING THE TIMER
• Press (large fl ame) to turn on the main burner.
• Press (large fl ame) to increase the fl ame height.
• Select Timer mode by briefl y pressing the SET button.
• Press (small fl ame) to decrease the fl ame height or to go to pilot standby position.
• Press and hold the SET button until the P1 (sun symbol is displayed) and the time fl ashes. S e t
Note:
While pressing either button a symbol the hour by pressing the (large fl ame) and set indicating transmission appears on the display. The receiver confi rms transmission with an acoustic signal.
the minutes by pressing the (small fl ame).
• Briefl y press SET button for the next burner cycle time.
TEMP - Daytime Temperature Mode
P2 (sun symbol) and P2 (moon symbol).
• Once all four (4) times are set, press OFF or simply
(appliance must be in standby mode; pilot ignited):
The room temperature is measured and compared to the set temperature. The fl ame height is then automatically adjusted to achieve the Daytime set temperature.
wait to complete programming.
TEMP
- Nighttime Setback Temperature Mode
(appliance must be in standby mode; pilot ignited):
The room temperature is measured and compared to the Nighttime Setback temperature. The fl ame height is then automatically adjusted to achieve the
Nighttime Setback temperature.
TIMER - Timer Mode
(appliance must be in standby mode; pilot ignited):
The Timer setting allows you to set two (2) burner
TEMP times and two (2) burner TEMP times every 24 hours.
For
TEMP
to operate as a thermostat, TEMP must be set at 40°F 4°C) or higher.
If the
TEMP
setting is decreased to -- , the motor will turn the valve to the standby position in the moon times and await the next burner TEMP cycle.
Note:
The display shows the set temperature every
30 seconds.
REV 2 - 1003150827 4 L-F2-108
(Only possible, when MANUAL knob is used)
Follow the burner system owner's manual for gaining access to the gas control and the pilot burner. Access to the pilot burner is only required for ignition with a match.
When turning main valve knob, do not force. Knob has a slip clutch that clicks until the end stops are reached.
This allows for manual fl ame height adjustment as well as adjustment to pilot standby position (see Fig.
5-1).
1. STOP! Read the safety information included before
proceeding.
2. Turn main valve knob to the OFF, full clockwise
position.
3. Turn MANUAL knob to the MAN, full clockwise
position.
4. Place ON/OFF switch in (OFF position).
5. Wait fi ve (5) minutes to clear out any gas. Verify that no gas is in the area around the appliance, including near the fl oor. If you detect gas STOP!
Follow "A" in the safety information on page 1. If no gas is present, proceed to step 6.
6. Place ON/OFF switch in (ON position).
7. With the MANUAL knob in MAN position a manual pilot valve operator and piezo igniter (optional) are accessible.
8. Change the ignition cable from the receiver (see
Fig.5-2a) to the valve (see Fig. 5-2b).
9. Fully push down manual pilot valve operator (using a small bladed screwdriver or similar) and hold in, to start pilot gas fl ow (see Fig. 5-1).
Piezo igniter
ON/OFF switch
(optional) in
ON position
8 wire receiver jack microswitch
Fig. 5-1 Combination control, cover
A.
B.
Fig. 5-2a/b Piezo igniter wiring
Connection piezo igniter tab 2.8 x 0.8 mm
MANUAL knob in MAN position
Manual pilot valve operator
Main valve knob in OFF position
Ignition with match:
Immediately light the pilot with a match, while continuing to hold in the manual pilot valve operator for about one (1) minute after the pilot is lit. Release manual pilot valve operator. If pilot does not stay lit, wait fi ve (5) minutes and repeat.
Ignition with piezo igniter:
12. lf the appliance will not operate, follow the instructions "TURN OFF GAS TO APPLIANCE" and call the service technician or gas supplier.
PRIOR TO ANY FUTURE AUTOMATIC
OPERATION; THE IGNITION CABLE MUST
BE CONNECTED BACK TO THE RECEIVER
(WHEN COOL).
Use the push piezo igniter to ignite. If pilot does not stay lit, wait fi ve (5) minutes and repeat.
Note: If the pilot does not stay lit after several
tries, follow the instructions "TURN OFF
GAS TO APPLIANCE" and call the service technician or gas supplier.
TURN OFF GAS TO APPLIANCE
• Press OFF button on remote.
• Follow burner system owner's manual for gaining accessibility to the gas control.
10.Turn MANUAL knob to the ON, full counterclockwise
position.
• Place ON/OFF switch in (off position).
11. Turn main valve knob to the full ON, full counterclockwise position.
• Turn main valve knob to the OFF full clockwise
position.
REV 2 - 1003150827 5 L-F2-108
MISCELLANEOUS
Low Battery Indication
Receiver: three short beeps will sound when motor turns
Remote with display:
"BATT" will appear on display
Note:
If the battery of the handset is low or if the transmitter is out of the communication range, the motor turns down the valve to pilot gas after 6 hours.
Note:
With very low battery the O1V system shuts off the fi re completely. This will not happen if the power supply is interrupted.
Battery Replacement
Battery replacement is recommended at the beginning of each heating season. Pull ribbon to remove batteries.
Do not use metal tools to remove batteries. Using a metal tool could cause a short that may damage the receiver.
Location of Receiver
When the RF-receiver is placed in the appliance, the surrounding metal can reduce reception considerably.
The position of the antenna on the receiver also infl uences reception. It is recommended to straighten the antenna. The antenna must not come in contact or cross the ignition wire, this may render the receiver inoperable.
REV 2 - 1003150827 6 L-F2-108
MANUAL Knob
Piezo Igniter (optional)
Connection for manual ignition
Main Valve
Knob
Combination Control
REV 2 - 1003150827
Thermocouple
Interrupter Block
Ignition Cable
ON/OFF Switch (optional)
OFF
ON
8 Wire Cable
Thermo Current Cable #2 or ON/OFF Switch with
Soldered Cable
Thermo Current Cable #1
RF Antenna
SPARK SW TC
SPARK
ON/OFF
Switch
SW TC
Thermocurrent
Interrupter Block
Pilot
GV 60
Receiver
4 AA Batteries
Battery Compartment
Button "RESET"
MA
GR
MO
SW
7
Fig. 7-1 Wiring Diagram
L-F2-108
NOTES PAGE
Please use this page to record any information about your remote system that you may want to have at hand.
REV 2 - 1003150827 8 L-F2-108
advertisement