FWMurphy Generator Controller Retrofitting Instructions
PDF
Documento
Pubblicità
Pubblicità
Autostart AS731 Generator Controller Installation Instructions mi6243 st revision A, 1 November 2002 catalog section 75 Section C: AS730 to AS731/AS732 retrofitting TM GENERAL INFORMATION WARNING Front facia AS730 AS731/732 BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT Disconnect all electrical power to the machine Make sure the machine cannot operate during installation Follow all safety warnings of the machine manufacturer Read and follow all installation instructions General The Autostart AS731 and AS732 are full function, programmable controllers for the automatic or manual control of a standby generator. Both units have similar features to the older AS730. This document gives compatibility details for use when fitting an AS731/732 in place of an AS730. Full information about the specification, installation and operation of the units may be found in the following documents:- 1. 2 line x 16-character backlit liquid crystal display 2. Operator control keys 3. Auto/manual mode LED indication Rear facia AS730 AS731/732 Doc. ref. Title ms6127 ms6343 mi6128 mi6129 mi6130 mi6131 ms5261 mi5264 mi5265 mi5266 AS731 bulletin and specification AS732 bulletin and specification AS731/732 installation section A: mounting/wiring AS731/732 installation section B: programming AS731/732 operation AS731/732 comms and AS7CN PC software AS730 bulletin and specification AS730 installation section A: mounting/wiring AS730 installation section B: programming AS730 communications and AS7CK PC software 4. 5. 6. 7. Mounting clamps Screw terminal blocks RS232 communication port (RJ11 connector) (AS732 only) RS485 comms ports (2 x RJ45 connectors) Panel mounting The AS730 and AS731/AS732 use the same casing and mounting procedure. Please consult document mi6128 for full details. TM FWMurphy Murphy PO Box 470248 Tulsa, Oklahoma 74147, USA tel: (918) 317 4100 fax: (918) 317 4266 email: [email protected] web: www.fwmurphy.com CONTROL SYSTEMS AND SERVICES DIVISION PO Box 1819, Rosenberg, Texas 77471, USA tel: (281) 342 0297 fax: (281) 341 6006 email: [email protected] FRANK W. MURPHY LTD. Church Rd, Laverstock, Salisbury, SP1 1QZ, UK tel: +44 1722 410055 fax: +44 1722 410088 email: [email protected] web: www.fwmurphy.co.uk MURPHY DE MEXICO S.A. DE C.V. Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje San Luis Potosí, S.L.P. México 78384 tel: + 52 444 8206264 fax: + 52 444 8206336 email: [email protected] web: www.murphymex.com.mx MURPHY SWITCH OF CALIFORNIA 41343 12th Street West, Palmdale, CA 93551-1442, USA tel: (661) 272 4700 fax: (661) 947 7570 email: [email protected] web: www.murphyswitch.com MACQUARRIE CORPORATION 1620 Hume Highway, Campbellfield, Victoria 3061, Australia tel: +61 3 9358 5555 fax: +61 3 9358 5558 email: [email protected] In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. ELECTRICAL CONNECTION DANGER ! HIGH VOLTS WARNING: DANGER OF INJURY OR DEATH. During normal operation, the AS730/731/732 is connected to high voltage circuits. Before connection, disconnection or handling of these units, ensure that all AC and DC power supplies are isolated. Connection to or disconnection from live wiring can also cause damage to Autostart internal components. Electrical Compatibility Most of the AS730 connections have electrically compatible counterparts on the AS731/AS732. Note, however, that the physical connectors and terminal numbering are NOT compatible. The AS730 has 3 vertically oriented terminals blocks, whereas the AS731/732 has 2 horizontal (non-compatible) blocks. Individual wiring connections must be unscrewed from the AS730 blocks, and re-connected into the appropriate AS731/732 terminal(s). AS730 AS731/ Function/Compatibility pin no. AS732 pin no. 8 (cont) - + The guide below gives terminal number cross references, and details of compatibility, for use when migrating from AS730 to AS731/AS732. Typical wiring diagrams for both units are shown on page 4. AS731 1 3 Negative DC power supply Positive DC power supply Fully compatible. 2 2 Charge fail input Fully compatible. Program the AS731/732 as for the AS730. 4 4 Positive DC / Emergency stop Fully compatible. 5 - 19 20 Magnetic pickup input Magnetic pickup input return On the AS730, one terminal of the (optional) magnetic is connected to pin 5; the other pickup terminal is connected to battery negative. On the AS731/732, a separate terminal (pin 20) is provided for the pickup return. 6 7 9 10 9 10 11 - Output 1 (AS730) / output 2 (AS731/732) Output 2 (AS730) / output 3 (AS731/732) Output 3 (AS730) / output 4 (AS731/732) Output 4 (AS730 only) AS730 programmable outputs 1 to 3 (pins 6, 7 and 9) are fully compatible with AS731/732 outputs 2 to 4 (pins 9, 10 and 11). AS730 output 4 is a relay based, negative DC output rated to 5 Amps max, with no direct equivalent on the AS731. 8 - A800 enable (AS730 only) Pin 8 of the AS730 allows for direct connection to (and seam free operation of) the ‘enable’ terminal of a Murphy A800 annunciator. The AS731/732 does not have a directly compatible terminal. If an A800 ‘enable’ connection is required, the same result can be achieved using a spare output: RL1 A800 enable 11 AS730 AS731/ Function/Compatibility pin no. As732 pin no. 1 3 connect the slave relay as shown below (AS731/732 output 4 shown), and program the output to ‘engine running’. The relay provides the A800 with the required positive DC input as soon as the AS731/732 detects an engine running state. 11 18 12 13 14 15 - 16 17 - 12 13 14 Input 1: (low) oil pressure Input 2: (high) engine temperature Input 1 and 2 return (AS731/732 only) These inputs allow connection to engine mounted fault switches or resistive senders. On the AS730, the ‘return’ side of the switch or sender is connected to battery negative DC. On the AS731/732, a separate connection (pin 14) is used for the return wiring, providing better immunity to signal noise. Program the AS731/732 as for the AS730. 18 19 20 15 16 17 Input 3 Input 4 Input 5 These programmable inputs are fully compatible. Programming of the AS731/732 is similar to the AS730, but each AS731/732 input can be individually set activate on open/closed/positive/negative signal. 21 - Index pin (AS730 only) 22 23 5 6 Fuel output Starter (crank) output Fully compatible. FWMurphy – AS731/732 installation section C: AS730 to AS731/AS732 retrofitting Remote start / mains fail Fully compatible. Program the AS731/732 as for the AS730 (open from / closed to positive DC to activate). No connection (AS730) No connection (AS730) No connection (AS730) No connection (AS730) st mi6243 revision A 1 November 2002 p2/4 ELECTRICAL CONNECTION (cont.) AS730 AS731/ Function/Compatibility pin no. AS732 pin no. Output 5 (AS730 only) 24 AS730 pin 24 is a positive DC relay output, rated to 5 Amps. There is no equivalent connection on the AS731/732. 25 26 7 8 Output 6 (AS730) / output 1 (AS731/732) Output 6 (AS730) / output 1 (AS731/732) AS730 output 6 (pins 25 and 26) is a pair of volt free, normally open contacts, rated to 5 Amp max. AS731/732 pins 7 and 8 are fully compatible with the above, but are designated output 1. Program AS731/732 output 1 as for AS730 output 6. The factory default programming for both is ‘gen contactor’. 27 28 29 30 - - AS730 AS731 Function/Compatibility pin no. AS732 pin no. 74 75 76 77 78 79 25 26 27 28 29 30 CT L1 CT L1 return CT L2 CT L3 return CT L3 CT L3 return These connections are electrically compatible. Program the AS731/732 as for the AS730. Communications RS232 communication Manual stop input (AS730 only) Manual start input (AS730 only) On the AS730, these pins allow optional connection of panel mounted manual mode start and stop push buttons. Both AS730 and AS731/732 have RS232 serial ports on the rear facia, allowing local or remote (modem) communication with a PC running Murphy software. AS730 communication is via a 9 way D-type connector, which also requires an external RS232 interface unit (models AS7CC or AS7CD). The AS731/732 uses an RJ11 (telephone type) connector and does not require a separate interface. The AS731/732 has no equivalent, dedicated connection, since manual mode starting and stop can be carried out from the front facia. The communication leads used with the AS730 cannot be used or easily modified for operation with an AS731/732. Replacement leads and adaptors are available from your Murphy representative. If remote panel controls are required, AS731/732 inputs 3 to 5 (if spare) can be programmed to ‘manual start’ and ‘manual stop’. To ensure compatibility with the AS730 wiring, the ‘manual start’ input must be set to activate on ‘closed to negative’, and the ‘manual stop’ input must be set to activate on ‘open from negative’. RS485 communication Generator AC (AS730 only) Generator AC (AS730 only) AS732 units feature RS485 MODBUS communications, accessed via 2 x RJ45 connectors on the rear facia. The AS730 and AS731 do not have an RS485 facility. For full details about AS731/732 communications, PC software and accessories, please refer to document mi6131. WARNING: HIGH VOLTAGE - DANGER OF INJURY OR DEATH. On the AS730, these (frequency sensing) connections are required in addition to the multi-phase connections on pins 70 – 73. On the AS731/732, frequency sensing is done through pins 21 – 24 (see below). 70 71 72 73 21 22 23 24 Generator AC phase L1 Generator AC phase L2 Generator AC phase L3 Generator AC neutral WARNING: HIGH VOLTAGE - DANGER OF INJURY OR DEATH. These connections are electrically compatible. Program the AS731/732 as for the AS730. FWMurphy – AS731/732 installation section C: AS730 to AS731/AS732 retrofitting st mi6243 revision A 1 November 2002 p3/4 ELECTRICAL CONNECTION (cont.) AS730 typical wiring diagram (automatic mains fail generator) mains contactor generator contactor LOAD L1 L2 L3 N L1 L2 L3 N L1 G L2 E L3 N N E R A T O R MCCB MCR1 MCR 1 2 3 4 5 6 Autostart 730 +ve DC Emergency RPO1 Stop fuse RPO2 RPO3 RPO4 + WL A – 5A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 70 71 72 73 74 75 76 77 78 79 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 GCR GCR1 1A 1A 1A inputs RFL magnetic pickup RST RAL IP5 IP4 IP3 HET LOP L1 L2 L3 N UVR500 manual manual start stop M A I N S fuel starter alarm –ve DC AS731 typical wiring diagram (automatic mains fail generator) mains contactor M L1 A L2 I L3 N N S generator contactor LOAD L1 L2 L3 N L1 G L2 E L3 N N E R A T O R MCCB L1L2 L3 N MCR1 UVR500 MCR GCR GCR1 123456 +ve DC RPO2 RPO3 + Emerg. Stop RPO4 A Autostart 731 21 5A fuse WL – magnetic pickup IP5 IP3 RST IP4 starter RFL HET fuel LOP inputs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 23 24 1A 1A 1A 25 26 27 28 29 30 –ve DC FWMurphy – AS731/732 installation section C: AS730 to AS731/AS732 retrofitting st mi6243 revision A 1 November 2002 p4/4 ">
/
Scarica
Solo un promemoria. Puoi visualizzare il documento qui. Ma soprattutto, la nostra IA l''ha già letto. Può spiegare cose complesse in termini semplici, rispondere alle tue domande in qualsiasi lingua e aiutarti a navigare rapidamente anche nei documenti più lunghi o complicati.
Pubblicità